Polarized Photon Beam Instrumentation for GlueX Part 1: active collimation Part 2: polarimetry Richard Jones, University of Connecticut GlueX collaboration.

Slides:



Advertisements
Similar presentations
Measuring the Neutron and 3 He Spin Structure at Low Q 2 Vincent Sulkosky College of William and Mary, Williamsburg VA Experimental Overview The.
Advertisements

Measuring the Neutron and 3 He Spin Structure at Low Q 2 Vincent Sulkosky for the JLab Hall A Collaboration College of William and Mary, Williamsburg VA.
Fast and Precise Beam Energy Measurement at the International Linear Collider Michele Viti.
Jin Huang PhD Candidate, MIT For MENU 2010 May 31, Williamsburg.
Collimation and tagging instrumentation for the GlueX photon beamline Richard Jones Igor Senderovich, Anne-Marie Carroll University of Connecticut APS/DNP.
Pair Spectrometer Design Optimization Pair Spectrometer Design Optimization A. Somov, Jefferson Lab GlueX Collaboration Meeting September
Hall D Photon Beam Simulation and Rates Part 1: photon beam line Part 2: tagger Richard Jones, University of Connecticut Hall D Beam Line and Tagger Review.
Upcoming Review of the Hall D Photon Beam and Tagger Richard Jones, University of Connecticut, for the GlueX collaboration GlueX Collaboration Meeting.
Status of the Tagger Hall Background Simulation Simulation A. Somov, Jefferson Lab Hall-D Collaboration Meeting, University of Regina September
Microscope Performance at elevated dark rates Richard Jones University of Connecticut collaboration GlueX collaboration meeting, Newport News, Feb. 2-4,
James M c Intyre University of Connecticut GlueX Collaboration Meeting JLab, Feb. 2-4, 2011.
Active Collimator Test in Hall B Richard Jones, University of Connecticut, for the GlueX collaboration GlueX Collaboration Meeting September ,
Beam Position Stabilization Using an Active Collimator in Hall D at Jefferson Lab Richard Jones, University of Connecticut, for the GlueX collaboration.
Simulation of electron beam halo in the Hall D tagger Richard Jones University of Connecticut GlueX collaboration meeting, Newport News, March 29-31, 2007.
EPAC June 2003 The EPAC June 2003 Questions 1. Clarify the Motivation for the Proposal. 2. How to ensure the e+ polarimeter works right away? 3. What is.
Electron Beam Simulation for GlueX Richard Jones, University of Connecticut GlueX collaboration meeting April 27-29, 2006 presented by.
Tagger Electronics Part 1: tagger focal plane microscope Part 2: tagger fixed array Part 3: trigger and digitization Richard Jones, University of Connecticut.
The Hall D Photon Beam Richard Jones, University of Connecticut Hall D Photon Beamline-Tagger ReviewJan , 2005, Newport News presented by GlueX Tagged.
Tagger hodoscope and photon beam monitoring D.Sober, F.Klein (CUA) Tagger Review, Jan.23-24, 2006.
GlueX Luminosity Limits Richard Jones, University of Connecticut GlueX Collaboration Meeting, Newport News, May 8-10, Design luminosity 2.Physics.
GlueX Simulations Status Report on CD3 geometry Richard Jones GlueX Collaboration Meeting, Newport News, January 10-12, 2008.
The GlueX Photon Beam Richard Jones, University of Connecticut GlueX Photon Beamline-Tagger ReviewJan , 2005, Newport News presented by GlueX Tagged.
Progress on Photon Beam and Simulation Part 1: active collimator Part 2: physics simulations Richard Jones, University of Connecticut GlueX collaboration.
The GlueX Photon Beam Richard Jones, University of Connecticut GlueX Photon Beamline-Tagger ReviewJan , 2005, Newport News presented by GlueX Tagged.
The Tagger Microscope Richard Jones, University of Connecticut Hall D Tagger - Photon Beamline ReviewJan , 2005, Newport News presented by GlueX.
The Hall D Photon Beam Overview Richard Jones, University of Connecticut Hall D Tagger and Beamline ReviewNov , 2008, Newport News presented by GlueX.
Photon Source and Tagger Richard Jones, University of Connecticut GlueX Detector ReviewOctober 20-22, 2004, Newport News presented by GlueX Tagged Beam.
Polarized Photons for GlueX Richard Jones, University of Connecticut GlueX Photon Beamline-Tagger ReviewNov , 2005, Newport News presented by GlueX.
Recent results from CERN NA59 Richard Jones, University of Connecticut GlueX collaboration meetingMay , Bloomington Does the enhancement seen.
M. Woods (SLAC) Beam Diagnostics for test facilities of i)  ii) polarized e+ source January 9 –11, 2002.
The Hall D Photon Beam Overview Richard Jones, University of Connecticut Hall D Tagged Photon Beam ReviewNov , 2008, Newport News presented by GlueX.
PAIR SPECTROMETER DEVELOPMENT IN HALL D PAWEL AMBROZEWICZ NC A&T OUTLINE : PS Goals PS Goals PrimEx Experience PrimEx Experience Design Details Design.
HPS Test Run Setup Takashi Maruyama SLAC Heavy Photon Search Collaboration Meeting Thomas Jefferson National Accelerator Facility, May 26-27,
The PEPPo e - & e + polarization measurements E. Fanchini On behalf of the PEPPo collaboration POSIPOL 2012 Zeuthen 4-6 September E. Fanchini -Posipol.
August 2005Snowmass Workshop IP Instrumentation Wolfgang Lohmann, DESY Measurement of: Luminosity (precise and fast) Energy Polarisation.
Status of the Beamline Simulation A.Somov Jefferson Lab Collaboration Meeting, May 11, 2010.
LRT2004 Sudbury, December 2004Igor G. Irastorza, CEA Saclay NOSTOS: a spherical TPC to detect low energy neutrinos Igor G. Irastorza CEA/Saclay NOSTOS.
Rosen07 Two-Photon Exchange Status Update James Johnson Northwestern University & Argonne National Lab For the Rosen07 Collaboration.
SHMS Optics Studies Tanja Horn JLab JLab Hall C meeting 18 January 2008.
Status of Beam loss Monitoring on CTF3 Results of Tests on LINAC and PETS as R&D for TBL Anne Dabrowski Northwestern University Thibaut Lefevre CERN CTF3.
NanoPHYS’12 – December 17-19, 2012 K. Nakano, S. Miyasaka, K. Nagai and S. Obata (Department of Physics, Tokyo Institute of Technology) Drift Chambers.
Measurement of F 2 and R=σ L /σ T in Nuclei at Low Q 2 Phase I Ya Li Hampton University January 18, 2008.
Malte Hildebrandt, PSIMEG - Review Meeting / 1   e  Drift Chambers Charge Division Test Chamber Testsetup for Cosmics Chamber Construction.
M. Dugger, February Triplet polarimeter study Michael Dugger* Arizona State University *Work at ASU is supported by the U.S. National Science Foundation.
Integrated Radiation Measurement and Radiation Protection of BES Ⅲ Zhang Qingjiang, Wu protection group, accelerator center, IHEP,
Overview of the GlueX Tagger and Photon Beamline..
1 G9a -FROST. 2 Experiments FROST New generation of CLAS photoproduction experiments with FROzen Spin Polarized Target (FROST) E02-112: γp→KY (K + Λ,
BES-III Workshop Oct.2001,Beijing The BESIII Luminosity Monitor High Energy Physics Group Dept. of Modern Physics,USTC P.O.Box 4 Hefei,
Apollo Go, NCU Taiwan BES III Luminosity Monitor Apollo Go National Central University, Taiwan September 16, 2002.
CEBAF The Continuous Electron Beam Accelerating Facility (CEBAF) at JLab in Newport News, Virginia, is used to study the properties of quark matter. CEBAF.
Photon Flux Control Liping Gan UNCW. Outline PrimEx-  experiment requirement Tagged photon Procedure to obtain the number of tagged photons Relative.
Calorimetry for Deeply Virtual Compton Scattering in Hall A Alexandre Camsonne Hall A Jefferson Laboratory Workshop on General Purpose High Resolution.
February, INP PAN FCAL Workshop in Cracow W. Lohmann, DESY The BCD (Baseline Configuration Document) The next calendar dates Where we are with FCAL.
Beam Halo Monitor : Q-bars+SiPMMike Albrow, 26 Aug 2010 A Beam Halo Monitor for the LHC based on Quartz Cherenkov Counters Mike Albrow (Fermilab) Features:
Photon Source and Tagger Richard Jones, University of Connecticut GlueX Detector ReviewOctober 20-22, 2004, Newport News presented by GlueX Tagged Beam.
Magnetized hadronic calorimeter and muon veto for the K +   +  experiment L. DiLella, May 25, 2004 Purpose:  Provide pion – muon separation (muon veto)
An electron/positron energy monitor based on synchrotron radiation. I.Meshkov, T. Mamedov, E. Syresin, An electron/positron energy monitor based on synchrotron.
 0 life time analysis updates, preliminary results from Primex experiment 08/13/2007 I.Larin, Hall-B meeting.
Taikan SUEHARA et al., LCWS2007 & DESY, 2007/06/01 R&D Status of ATF2 IP Beam Size Monitor (Shintake Monitor) Taikan SUEHARA, H.Yoda, M.Oroku,
Photon Source and Tagger Richard Jones, University of Connecticut GlueX Detector ReviewOctober 20-22, 2004, Newport News presented by GlueX Tagged Beam.
ArgonneResult_ ppt1 Comparison of data and simulation of Argonne Beam Test July 10, 2004 Tsunefumi Mizuno
Overview of recent photon beam runs at CLAS CLAS12 European Workshop, Feb , Genoa, Italy Ken Livingston, University of Glasgow Tagged photons.
R. Arnold SLAC 24 June 2002 Real Photon Collaboration Conceptual Design Review Beam Monitoring Instruments.
Timelike Compton Scattering at JLab
Collimation and tagging instrumentation
CLAS, Hall-B Tagged linear and circularly polarised photons
Polarimetry Ken Livingston Sept 2012
The Hall D Photon Beam Overview
Proposal for an Experiment: Photoproduction of Neutral Kaons on Deuterium Spokespersons: D. M. Manley (Kent State University) W. J. Briscoe (The George.
CLIC luminosity monitoring/re-tuning using beamstrahlung ?
Presentation transcript:

Polarized Photon Beam Instrumentation for GlueX Part 1: active collimation Part 2: polarimetry Richard Jones, University of Connecticut GlueX collaboration meeting Dec , 2003, Newport News

Richard Jones, GlueX meeting, Newport News, Dec , GlueX activity at Connecticut: Part 1 simulation and software  Geant simulation  experiment geometry description  software tools crystal radiator  diamond quality control  crystal mount photon tagger instrumentation  tagging microscope photon beam instrumentation  beam line shielding  beam position control  photon beam polarimetry

Richard Jones, GlueX meeting, Newport News, Dec , Active collimator project overview active stabilization required for collimation  distance from radiator to collimator 75 m  radius of collimator aperture 1.7 mm  size of real image on collimator face 4 mm r.m.s.  size of virtual image on collimator face 0.5 mm r.m.s.  optimum alignment of beam center on collimator aperture ±0.2 mm in x and y steering the electron beam  BPMs on electron beam measure x and y to ±0.1 mm  BPM pairs 2 m apart gives ±4 mm at collimator  BPM technology might be pushed to reach alignment goal, under the assumption that the collimator is stationary in this ref. sys.

Richard Jones, GlueX meeting, Newport News, Dec , Active collimator project overview best solution: monitor alignment of both beams  monitor on electron beam position is needed anyway to control the spot on the radiator  BPM precision in x is affected by the large beam size along this axis at the radiator  independent monitor of photon spot on the face of the collimator guarantees good alignment  photon monitor also provides a check of the focal properties of the electron beam that are not measured with BPMs. 0.5 mm 1.9 mm 1  contour of electron beam at radiator

Richard Jones, GlueX meeting, Newport News, Dec , This work is the senior project of Connecticut undergraduate Chris Gauthier

Richard Jones, GlueX meeting, Newport News, Dec , Beam line simulation Detailed photon beam line description is present in HDGeant  beam photons tracked from exit of radiator  assumes beam line vacuum down to a few cm from entry to primary collimator, followed by air  beam enters vacuum again following secondary collimator and continues down to a few cm from the liquid hydrogen target  includes all shielding and sweep magnets in collimator cave  monitors background levels at several positions in cave and hall  simulation has built-in coherent bremsstrahlung generator to simulate beam line with a realistic intensity spectrum The same simulation also includes the complete GlueX target and spectrometer, detector systems, dump etc.

Richard Jones, GlueX meeting, Newport News, Dec , Beam line simulation Hall D collimator cave tagger building vacuum pipe Fcal Cerenkov spectrometer cut view of simulation geometry through horizontal plane at beam height

Richard Jones, GlueX meeting, Newport News, Dec , Beam line simulation overhead view of collimator cave cut through horizontal plane at beam height collimators sweep magnets iron blocks concrete lead 12 m air vac

Richard Jones, GlueX meeting, Newport News, Dec , Beam line simulation 3d view of primary collimator with segmented photon rate monitor in front

Richard Jones, GlueX meeting, Newport News, Dec , Design criteria for photon monitor radiation hard (up to 5 W of gamma flux) require infrequent access (several months) dynamic range factor 1000 good linearity over full dynamic range gains and offsets stable for run period of days sampling frequency at least 60 Hz at operating beam current, 600 Hz desireable fast analog readout for use in feedback loop

Richard Jones, GlueX meeting, Newport News, Dec , Design choice Segmented scintillator  used for the Hall B collimator (lower currents)  not very rad-hard Ion chamber  requires gas system and HV  good choice for covering large area Tungsten pin-cushion detector  used on SLAC coherent bremsstrahlung beam line in 1970’s  SLAC team developed the technology through several iterations, refined construction method  reference Miller and Walz, NIM 117 (1974)  SLAC experiment E-160 (ca. 2002, Bosted et.al.) still uses them, required building new ones  performance is known

Richard Jones, GlueX meeting, Newport News, Dec , Simulation geometry 12 cm5 cm

Richard Jones, GlueX meeting, Newport News, Dec , Detector response the photons are incident on the back side of the pin- cushions (opposite the pins) showers start in the base plates (~2 radiation lengths) showers develop along the pins, leaking charges into the gaps charge flow is asymmetric (more e - than e + ) due to high- energy delta rays called “knock-ons” asymmetry leads to net current flow on the plates proportional to the photon flux that hits it SLAC experience shows that roughly 1-2 knock-ons are produced per incident electron 1  A * rad.len. * ln(E 0 /E 1 )  1 – 2 nA detector current

Richard Jones, GlueX meeting, Newport News, Dec , Detector response from simulation inner ring of pin-cushion plates outer ring of pin-cushion plates beam centered at 0, radiator I e = 1  A

Richard Jones, GlueX meeting, Newport News, Dec , Beam position sensitivity using inner ring only for fine-centering ±200  m of motion of beam centroil on photon detector corresponds to ±5% change in the left/right current balance in the inner ring

Richard Jones, GlueX meeting, Newport News, Dec , Beam position sensitivity Sensitivity is greatest near the center. Outside the central 1 cm 2 region the currents are non-monotonic functions of the coordinates. CG demonstrated a fitting procedure that could invert the eight currents to find the beam center to an accuracy of ±350  m anywhere within 3 cm of the collimator aperture. Using BPMs and survey data, the electron beam can be steered to hit a strike zone 6 cm in diameter from a distance of 75 m.

Richard Jones, GlueX meeting, Newport News, Dec , Electronics and readout tungsten plate is cathode for current loop anode is whatever stops the knock-ons  walls of collimator housing  primary collimator  for good response, these must be in contact tungsten plate support must be very good insulator – boron nitride (SLAC design) uses differential current preamplifier with pA sensitivity experience at Jlab (A. Freyberger) suggests that noise levels as low as a few pA can be achieved in the halls  requires keeping the input capacitance low (preamp must be placed near the detector)  differential readout, no ground loops

Richard Jones, GlueX meeting, Newport News, Dec , Present status and future plans A prototype detector is under construction.  aluminum housing already fabricated at Connecticut  mechanical drawings of tungsten pin-cushions exist  two options for fabrication 1.cut pins from tungsten wire and manually mount them into machined tungsten wedges (first method tried at SLAC) 2.start off with a thick tungsten wedge and remove the excess material using Electrostatic Discharge Machining leaving only base plate and pins (superior result, SLAC) The goal is to build and instrument a prototype with two opposing pin-cushions and test it in the Hall B photon beam line. Budget estimate for prototype is about 15K$, and about 20K$ additional to complete the full detector and electronics.

Richard Jones, GlueX meeting, Newport News, Dec , GlueX activity at Connecticut: Part 2 simulation and software  Geant simulation  experiment geometry description  software tools crystal radiator  diamond quality control  crystal mount photon tagger instrumentation  tagging microscope photon beam instrumentation  beam line shielding  beam position control  photon beam polarimetry

Richard Jones, GlueX meeting, Newport News, Dec , Photon beam polarimetry Polarimetry is the least worked out aspect of the GlueX beam line Conceptual Design.  CDR section copied Hall B plan (1998)  no follow-up in terms of measurements  no criteria for precision Argument for linear polarization for GlueX is qualitative  provides initial state with definite parity  separates natural/unnatural exchange production Making a quantitative argument would involve trying to guess what the critical channels will be and what backgrounds will be important to eliminate. Alternative to a physical argument for precise polarimetry would be common sense: build a state-of-the-art device and be prepared to push the precision if the analysis requires it.

Richard Jones, GlueX meeting, Newport News, Dec , Facilites with experience in photon polarimetry  Saskatoon  Mainz  Hall B – organized Photon Polarimetry Workshop (1998)  Yerevan synchrotron (YerPhI) Connecticut / YerPhI collaboration established 2002  develop precise photon polarimetry for coherent bremsstrahlung beams  funded by CRDF grant AP YE-02 (64K$ for 2 years) Progress so far  review of 4 methods, two articles in draft form  beam time allocated at YerPhI to test 1 method in 2004 CB polarimetry project at YerPhI

Richard Jones, GlueX meeting, Newport News, Dec , Polarimetry: method 0 measure azimuthal distribution of  0 photoproduction from a spin-0 target  sometimes called “coherent  0 photoproduction”  elegant – has 100% analyzing power  analysis is trivial – just N(  ) ~ 1 + P cos(2  )  coherent scattering is not essential  only restriction: target must recoil in a spin-0 state practical example: 4 He scattering  must detect the recoil alpha in the ground state  requires gas target, high-resolution spectrometer for E  ~ GeV  cross section suppressed at high energy not competitive at GlueX energies

Richard Jones, GlueX meeting, Newport News, Dec , Polarimetry: method 1 pair production from a crystal  makes use of a similar coherent process in pair production as produced the photon in CB  requires counting of pairs, but not precision tracking  analyzing power increases with energy (!)  second crystal, goniometer needed  asymmetry is in rate difference between goniometer settings  can also be done in attenuation mode, using a thick crystal sources of systematic error  sensitive to choice of atomic form factor for pair-target crystal  shares systematic errors with calculation of CB process  in addition to theoretical uncertainty, it involves a model of the beam and crystal properties

Richard Jones, GlueX meeting, Newport News, Dec , Polarimetry: method 2 angular distribution from nuclear pair production  sometimes called “incoherent pair production”  polarization revealed in azimuthal distribution of plane of pair  requires precise tracking of low-angle pairs, which becomes increasingly demanding at high energy  analyzing power is roughly independent of photon energy  analyzing power depends on energy sharing within the pair  best analyzing power for symmetric pairs  requires a spectrometer for momentum analysis systematic errors  atomic form factor  multiple scattering in target, tracking elements or slits  simulation of geometric acceptance of detector

Richard Jones, GlueX meeting, Newport News, Dec , Polarimetry: method 3 angular distribution from pair production on atomic electrons  sometimes called “triplet production”  polarization reflected in a number of observables  azimuthal distribution of large-angle recoil electrons is a preferred observable  analyzing power is roughly constant with photon energy  no need for precision tracking of forward pair  pair spectrometer still needed to select symmetric pairs systematic errors  reduced dependence on atomic physics – “exact” calculations  analyzing power sensitive to kinematic cuts  relies on simulation to know acceptance

Richard Jones, GlueX meeting, Newport News, Dec , Polarimetry: method 4 analysis of the shape of the CB spectrum  not really polarimetry – this you do anyway  probably the only way to have a continuous monitor of the beam polarization during a run  polarimetry goal would be to refine and calibrate this method for ultimate precision  takes advantage of tagging spectrometer  requires periodic measurements of tagging efficiency using a total absorption counter and reduced beam current systematic errors  atomic form factor used to calculate CB process  model of electron beam and crystal properties  photon beam alignment on the collimator

Richard Jones, GlueX meeting, Newport News, Dec , Planned activities at YerPhI in 2004 beam time approved for CB measurements  electron beam energy 4.5 GeV  4-week run during summer 2004  goniometer, crystal, pair spectrometer already installed to test IPP method  results anticipated for next fall visits of YerPhI physicists to Jlab  travel support provided in CRDF grant  should be timed to coincide with GlueX meeting

Richard Jones, GlueX meeting, Newport News, Dec , Present status, future plans visit to Yerevan 11/03  R. Jones visited Yerevan for 8 days in November, 03  accelerator is quiet (and dark) but group is still active  both theory and experimental expertise in CB  good response to seminar on GlueX possible role for YerPhI in GlueX  Deputy Director A. Sirunian has expressed interest  group seeks invitation and open projects in GlueX  polarimetry would be an obvious place to start