Department of Anesthesia and Perioperative Care advancing health worldwide TM Combined ICD/Pacing Devices What options are available? What’s new in the.

Slides:



Advertisements
Similar presentations
Appendix E Pacemakers Gail Walraven, Basic Arrhythmias, Seventh Edition ©2011 by Pearson Education, Inc., Upper Saddle River, NJ.
Advertisements

Dual Chamber Temporary Pacing Operations & Troubleshooting
Patient Contact Careers Naomi Cox Product Specialist and Territory Manager- St Jude Medical Australia.
Pacemakers & Pacing in the ED Albury Wodonga Education Program 2014.
ELECTROPHYSIOLOGY LAB
Automated External Defibrillation
Pacemaker Malfunctions Even less amusing!. Pacemaker Codes (NASPE/BPEG) Position I IIIII Category Chamber(s) Chamber(s) Response to paced sensed sensing.
EKG Monitoring.
RYTHMIQ™ Operation RYTHMIQ operates in AAI(R) pacing mode with VVI backup during times of normal conduction, switching to DDD(R) mode when a conduction.
William H. Maisel, MD, MPH Director, Medical Device Safety Institute Beth Israel Deaconess Medical Center Statement to the FDA Risk Communication Advisory.
Jennifer Cohen, MD, Heather Costa, PhD, Robert Russo, MD, PhD, Division of Cardiovascular Diseases, Scripps Clinic, La Jolla, CA The MagnaSafe Registry:
Pacemakers and Implantable Cardioverter-Defibrillators
Preanesthetic Evaluation of Pacemakers 101 David A. Cross, M.D. Department of Anesthesiology Scott and White Memorial Hospital and Clinic Associate Professor,
Pacemakers and Implantable Defibrillators
Implantable Cardioverter Defibrillator Rebecca Boduch Biomedical Engineering University of Rhode Island.
Computers in the Medical Profession.  This is the intersection of information science, computer science, and health care  It began in the 1950’s with.
Computers in the Medical Society. Medical Informatics This is the intersection of information science, computer science, and health care It began in the.
EACLS An outstanding program for ACLS initial and refresher training TM.
Juan Camilo Diaz Cardiac Pacemakers.
Chapter 6 AED.
Arrhythmias Medical Student Teaching Tuesday 24 th January 2012 Dr Karen Jones, SpR Emergency Medicine.
Anesthetic Management of Cardiac Rhythm Management Devices N746: Summer 2014 Jennifer Ranieri.
Pacemakers and Implanted Defibrillators Mike Harlan.
RYTHMIQ™ INGENIO™ offers RYTHMIQ, which is designed to minimize unnecessary RV pacing without clinically significant pauses.
Pacemaker Emergencies Arun Abbi MD Jan 21, Overview Initial approach Pocket Complications Acute complications with placement Nonarrythmic complications.
EKG Analysis Ventricular Arrhythmias. Ventricular arrhythmias conduct more slowly so the QRS is wide (greater than.12 seconds) They are usually caused.
Single Chamber Temporary Pacing Operations & Troubleshooting.
Following the Path of Least Resistance: The Road Most Traveled
Elsevier items and derived items © 2006 by Elsevier Inc. Chapter 37 Interventions for Clients with Dysrhythmias.
IABP, VAD, ICD & Pacemaker Therapies Diane E. White RN CCRN PhD.
The Latest Device Therapy in W. Herts Dr Philip Moore.
St. Jude Medical Edmundo Lozano June 21, Stock Information Ticker: STJ Price (June 18, 2010): $ week range: $ $42.87.
Wireless Cardiac Device Monitoring Presented by: Ashley D. Solomon, RN Nursing 457: Nursing Informatics Fall 2009.
Perioperative Care of Patients with Cardiac Rhythm Management Devices
Pacemakers and MRI An outdated contraindication? Emily Myers Research in Allied Health East Tennessee State University.
Cardiac Pacemakers © D. J. McMahon 2012 rev
Wolff-Parkinson-White Syndrome Liz Johnson, RN. Definition WPW syndrome is the presence of accessory pathways along with the normal conduction pathways.
Heart Failure Coordinator Jocelyn McCullough, APPN, ACNS-BC, CHFN X76775
New Findings in the Management of AF in Pacemaker Patients Results from the MINERVA Trial a Medtronic sponsored trial February 2014.
Pacing the Heart Ayo Ositelu ECE 5030 Final Presentation Tuesday, 15 December 1:00pm.
EP show – June 2004 EP show The EP show: Risk stratification for sudden death Eric Prystowsky MD Director, Clinical Electrophysiology Laboratory St Vincent.
Copyright © 2014 Wolters Kluwer Health | Lippincott Williams & Wilkins Chapter 33 Disorders of Cardiac Conduction and Rhythm.
THE HEART’S ELECTRICAL SYSTEM Marco Perez, MD Center for Inherited Cardiovascular Disease Inherited Cardiac Arrhythmia Clinic June 20, 2013.
Supparerk Prichayudh M.D
Cardiovascular Therapeutic Management 2013
Alireza Heidari Bakavoli, MD. Cardiology department Qaem medical center Mashhad University of Medical Science Role of ICD and CRT devices in Heart failure.
AsystolE Definition: Asystole is the absence of electrical activity in the myocardium.
Heart Blocks and Pacing
Staff Anesthesiologist – Allegheny Health Network
Temporary Pacemakers.
American College of Cardiology Presented by Dr. Stuart J. Connolly
Cardiac Pacemakers new 10 Oct 12 D McMahon.
Video Capsule Endoscopy in Patients with Implantable Cardiac Devices: Safety, Interference and Beyond Rabih Tabet MD, Najib Nassani MD, MSc, Boutros Karam.
Pacemakers and Implantable Cardioverter-Defibrillators
Laurie Racenet, FNP, MSN, CCDS, CEPS, FHRS
Fig. 2. Electrocardiogram monitored in the operation room
Jeff Healey MD, MSc, FHRS Director of Arrhythmia Service
Dysrhythmias Disorders of formation or conduction (or both) of electrical impulses within heart Can cause disturbances of Rate Rhythm Both rate, rhythm.
Pacemakers and Devices – Interactive Session
EKGs and Pacemakers Cooper University Hospital
Diathermy and its safe use
Systemic Sarcoidosis and Cardiac Conduction Abnormalities
Volume 6, Issue 10, Pages (October 2009)
David D. Berg et al. JACC 2018;71:
Volume 6, Issue 12, Pages (December 2009)
Mintu P. Turakhia et al. JACEP 2016;2:
Cautery (ELECTRO MAGNETIC INTERFERENCE) & cardiac devices in endoscopy
Mary Jane Rasmussen, RN, Paul A. Friedman, MD, Stephen C
Managing cross talk between a subcutaneous implantable cardioverter-defibrillator and a dual-chamber unipolar pacemaker system  Konstantinos Kossidas,
Pacemakers, Cardioverters, and Defibrillators
Presentation transcript:

Department of Anesthesia and Perioperative Care advancing health worldwide TM Combined ICD/Pacing Devices What options are available? What’s new in the pacing world? William A. Shapiro, M.D.

Department of Anesthesia and Perioperative Care advancing health worldwide TM What’s Not New - Your Best Friend Charles L. Witherell, RN, ACNS-BC, MSN Charles L. Witherell, RN, ACNS-BC, MSN Clinical Nurse Specialist, Pacemakers Clinical Nurse Specialist, Pacemakers Cardiac Electrophysiology Service Cardiac Electrophysiology Service UCSF Arrhythmia and Device Clinic UCSF Arrhythmia and Device Clinic 350 Parnassus Ave., Room Parnassus Ave., Room 204 Pager: Pager: Voic Voic

Department of Anesthesia and Perioperative Care advancing health worldwide TM The algorithms that each company uses to create their ICDs and Pacemakers are among the company’s most closely guarded secrets. What’s Not New

Department of Anesthesia and Perioperative Care advancing health worldwide TM The Pacemaker Companies Medtronic: Medtronic: St. Jude Medical: St. Jude Medical: Boston Scientific- Boston Scientific now owns Guidant Boston Scientific- Boston Scientific now owns Guidant All 3 have humans answering the phone 24/7/365 All 3 have humans answering the phone 24/7/365 FDA- FDA- AHA- AHA-

Department of Anesthesia and Perioperative Care advancing health worldwide TM The Pacemaker Card Physician’s name Physician’s name Generator and lead serial numbers Generator and lead serial numbers Manufacturer tech support number Manufacturer tech support number The pacemaker card does not contain any information about the current programmed mode, the magnet response, the reason it was inserted, or when the pacemaker was last checked

Department of Anesthesia and Perioperative Care advancing health worldwide TM Guidant T-180 (ICD/Pacemaker) First released in This model is still available. ICD- Defibrillation for V-fib, or rapid V-tach Anti-bradycardia pacing- ventricular pacing only. It only has an inhibited (synchronous) mode. Fixed-rate (asynchronous) pacing is not a programmable option. The ventricular rate is programmable, but of course, it will always remain in the VVI mode after programming. It cannot be put into a permanent fixed-rate pacing mode. Not to be confused with the T-1000, which is the “fictional” android assassin featured as the main antagonist in Terminator 2: Judgment Day (released in 1991).

Department of Anesthesia and Perioperative Care advancing health worldwide TM Why might a pacemaker not have an asynchronous mode option? Why might a pacemaker not have an asynchronous mode option? What is the danger of an asynchronous mode option? (Hint- Same as question above) What is the danger of an asynchronous mode option? (Hint- Same as question above) Answer: The companies are afraid of a fixed rate pacemaker spike causing an R-on-T induced ventricular tachycardia or ventricular fibrillation. Answer: The companies are afraid of a fixed rate pacemaker spike causing an R-on-T induced ventricular tachycardia or ventricular fibrillation. Guidant T180 (ICD/Pacemaker) (Guidant is now Boston Scientific)

Department of Anesthesia and Perioperative Care advancing health worldwide TM Pacemaker Induced “R on T” Arrhythmia

Department of Anesthesia and Perioperative Care advancing health worldwide TM All 3 American Pacemaker/ICD companies now provide ICD/Anti- bradycardia pacemakers in which the ICD function can be inhibited, and the anti-bradycardia pacing can be programmed into either the inhibited or asynchronous (fixed-rate) mode. What’s New ?

Department of Anesthesia and Perioperative Care advancing health worldwide TM Technology marches forward- generators will have more options. The devices will get smaller and lighter. New combined ICD/Pacemakers now have an “on/off Electrocautery” mode. Once the ICD is off, the pacer can be either fixed rate or inhibited. Pacing can be VOO, AOO, or DOO, at any rate. What’s New ?

Department of Anesthesia and Perioperative Care advancing health worldwide TM Minimal Ventricular Pacing (MVP): A proprietary Medtronic feature where the pacemaker learns to reset its own mode from sensing the patient’s cardiac conduction properties. AAI->DDD Minimal Ventricular Pacing (MVP): A proprietary Medtronic feature where the pacemaker learns to reset its own mode from sensing the patient’s cardiac conduction properties. AAI->DDD In-home wireless monitoring of pacemaker activity. The information is sent to a remote “secure” company database. In-home wireless monitoring of pacemaker activity. The information is sent to a remote “secure” company database. What’s New ?

Department of Anesthesia and Perioperative Care advancing health worldwide TM What’s Not New - Your Best Friend Charles L. Witherell, RN, ACNS-BC, MSN Charles L. Witherell, RN, ACNS-BC, MSN Clinical Nurse Specialist, Pacemakers Clinical Nurse Specialist, Pacemakers Cardiac Electrophysiology Service Cardiac Electrophysiology Service UCSF Arrhythmia and Device Clinic UCSF Arrhythmia and Device Clinic 350 Parnassus Ave., Room Parnassus Ave., Room 204 Pager: Pager: Voic Voic