DEPARTMENT OF DEVELOPMENT SERVICES BUILDING DIVISION Ronald L. Lynn, Director/Building Official Gregory J. Franklin, Assistant Director Neil Burning, Manager.

Slides:



Advertisements
Similar presentations
NFPA-101, LIFE SAFETY CODE, 2003 EDITION Chapter 15 Existing Schools
Advertisements

Determining the Occupant Load
Fire-Resistive Construction (2nd part)
NFPA 72 and NFPA 101 Supervised Automatic Sprinkler System Overview
Means of Egress Talia Ordonez Alex Prodanov Margarita Binkin Team.
Building CODES Arch 3011 Design Studio 1 Prof. Sargent Architecture Southern Polytechnic State University.
PERMITS & INSPECTIONS DEPARTMENT 2003 INTERNATIONAL RESIDENTIAL CODE IRC.
of NFPA 101 Life Safety Code Administration Definitions General
ACCESSIBILITY: A CODE COMPLIANCE AND EXISTING CONDITIONS ASSESSMENT AND SURVEY OF THE LIMERICK TOWN HALL MAIN STREET LIMERICK, ME ttl-Architects LLC 28.
Accessibility.  A building code is a set of rules that specify the minimum acceptable level of safety for buildings. The main purpose of building codes.
IRC 2009 Habitable Attics.
High-Rise Hotels New Codes General Fire Safety Information Ted Erb Fire Prevention Officer Bellevue Fire Department April
Michigan Department of Licensing and Regulatory Affairs Bureau of Construction Codes.
Night Club Retrofit N. J. A. C. 5:70 – 4. 7 Night Club Retrofit Objectives Define what is a night club What are the requirements under the Code Why.
IBC 2006 Chapter 5 Building Height and Areas After determining occupancies, the code analysis determines what height and areas are allowable for the occupancy.
ONLINE SELF-STUDY Emergency Coordinator Annual Update.
Smoke Control Fire-Rated Stairwells Fireproofing of Structural Components Egress Lighting Fire-Resistive Construction Elements Fire and Smoke Dampers Emergency.
2012 International Fire Code Adopted as the minimum fire safety standard by the State of Wyoming City of Sheridan must adopt the minimum standard to retain.
FIRE DESIGN OF BUILDINGS VULNERABLE GROUPS. COMPONENTS OF FIRE building materials unattended stoves Loose electrical connections overloaded electrical.
Northwest Region CSI S508 Code Part 2 Seminar 1A Stephen Winstead, AIA.
EGRESS AND FIRE PROTECTION
OBC 2009 CHAPTER FIVE GENERAL BUILDING HEIGHTS AND AREAS.
Health Facilities Planning Seminar Plan Review Division Irvin J. Poke, AIA, Chief Todd Y. Cordill, NCARB, Assistant Chief Providing for Michigan’s Safety.
Building Codes in Construction Documents Salt Lake City, Utah September 26, 2012 Presenter: Gregory Markling, FCSI, SCIP, CCS, CCCA, LEED AP BD+C, NCARB.
PERFORMANCE & CODE ANALYSIS TIMBer Inc. ·Brooke Fedder · Marie Rottschaeffer· Izzie Molinuevo· Tena Pettit·
© 2012 Ted “Smitty” Smith  This slide show contains multiple timed questions. All questions can be answered using the International Fire Code and the.
Governmental Constraints on Construction Chapter 2.
Occupancy Classification Under NFPA 13 Examine the proposed facility and make recommendation on the Occupancy Classification Used to classify fuel loads.
Florida Existing Building Code Basic objectives and Approach Basic objectives: Encourage Use and Re-Use while requiring reasonable safety requirements.
Building Codes and Interior Design
Governmental Constraints on Construction Chapter 2.
© 2008 Delmar, Cengage Learning Property Security, Emergency Response, and Fire Protection Systems Chapter 13.
Means of Egress Chapter 4.
Building Codes. Codes  Building Code –Regional  BOCA, SBCCI, CABO, UBC, CITY OF DALLAS, –National  IBC  Fire Code –NFC, UFC, NFPA, Life Safety 101.
Building Codes Intended to protect the public by establishing minimum standards of building safety.
Code Analysis. Identify the relevant codes  Local building code  Local accessibility code (or ADA)  Local fire code (or the NFPA)  Mechanical, electrical.
Fire Safety By Alicia Civile and Alexandra Fernandez.
MINNESOTA CHAPTER AUTOMATIC FIRE ALARM ASSOCIATION Requirements of the 2003 Minnesota State Fire Code relating to Group R Occupancies September 14, 2006.
Code Analysis: Don’t try this at home. Identify the relevant codes  Local building code  Local accessibility code (or ADA)  Local fire code (or the.
ID 440: Project 1: Hospitality Design
The Essentials of Egress
INTD 51 human environments building code. building codes deal with almost every area of building planning, design & construction they are very complex.
Design Development Code analysis Partition types.
ID 234 Building Codes Fall 2012 Means of Egress Chapter 4.
Construction Types Chapter 3.
Means of Egress Part 3 Chapter 4.
Maine State Fire Marshals Office1 Laws and Codes Relating to Existing Apartment occupancies in the State of Maine Mark Stevens CFI-II, CFPS, CFPE Inspections.
Codes.
ID 234 Building Codes Fall 2011 Means of Egress Chapter 3, part II.
Chapter 4 ID 234 Building Codes Fall 2011 Means of Egress.
Toilet design Many different regulations 1. guess what toilet features might be regulated? building code? accessibility code? universal design?
Work Area Method Level 3 Alterations – Chapter 9 prescribes requirements. 50% of Building Area Rule.
INTRODUCTION TO CONSTRUCTION TYPES Code Consultant:Steven R. Winkel, FAIA, PE The Preview Group, Inc. Contractor: Scott Smith.
“My Room” Project The Massachusetts Code Book and the rules that apply.
Building Construction
Exercise #2 (part 2) Based on what you read in Chapter 4, determine if the corridors and exit doors meet the requirements for egress width, according to.
Code of Practice for Fire Safety in New and Existing Community Dwelling Houses Eamon O’ Boyle.
2009 IBC Egress Issues in Commercial Buildings, May 25, 2011
Chapter 2 Building Occupancy
Table of Contents for Subpart E Coverage and Definitions
Wilson Hall Fire Protection Features
ARCHITECTURAL SAFETY FEATURES –Exit Separations –Continuation of Exit Stairs from lower to upper floors –Discharge from Exits FIRE PROTECTION FEATURES.
RULES OF ENGAGEMENT.
Design of Evacuation System for High-Rise Building Danqing Yu
29 CFR NFPA Life Safety Code
Occupancy Classifications and Loads
February 2019.
Building standards Mr. Da Silva.
Fire Alarm Practice Drill # 11 Denver Fire Department Journeyman Installer License Test © Ted Smith 2017.
Denver Fire Depart. License Fire Alarm Practice Test # 12
Presentation transcript:

DEPARTMENT OF DEVELOPMENT SERVICES BUILDING DIVISION Ronald L. Lynn, Director/Building Official Gregory J. Franklin, Assistant Director Neil Burning, Manager of Plans Examination

PROPOSED ASSEMBLY USES IN EXISTING OPEN PARKING GARAGES The Clark County Building Division has identified a number of concerns regarding the proposed use of an existing open parking garage for any assembly uses.

PARKING STRUCTURE

ASSEMBLY EVENTS Fremont Street Concert Mandalay Bay Concert

STRUCTURAL The Building Code requires a parking garage to meet a minimum structural design standard of 40 psf for live loads, whereas the minimum live load design standard for buildings used for assembly purposes is 100 psf, or 250% greater. If a stage or platform is provided in the assembly use, the minimum live load required for the stage or platform is 125 psf or 313% greater than what is required for parking garages.

STRUCTURAL CONTINUED All buildings must also meet specific occupancy category requirements for structural design. These categories are assigned by the intended use of the building. A parking garage is assigned as a Category II building, while a building used for public assembly is classified as a Category III building. A Category III classification requires the building to meet more stringent design standards for resisting seismic, snow and wind loads. Therefore, the minimum structural design for buildings used for an assembly use must resist a 25% greater seismic load, a 10% greater snow load, and a 15% greater wind load than what is required for the structural design of a parking garage. These significant differences in minimum structural design requirements represents a potential life-safety risk to the building occupants, if an existing parking garage was allowed to be used for assembly purposes.

MEANS OF EGRESS There are also substantial differences in the means of egress requirements for buildings used for assembly versus a building used as an open garage, including the following:

MEANS OF EGRESS CONTINUED  Travel Distance In a typical parking garage (non-sprinkled) the occupants are permitted to travel a distance of 300 feet in order to reach an exit. However, a building used for public assembly is limited to a maximum travel distance of 200 feet; 250 feet if the building has fire sprinklers throughout. However, a building used for public assembly is limited to a maximum travel distance of 200 feet; 250 feet if the building has fire sprinklers throughout. This travel distance restriction is due to the fact that it takes much more time for the occupants in assembly buildings to exit due to the much greater number and density of the occupants.

MEANS OF EGRESS CONTINUED  Size and Number of Exits The occupant load for a parking garage is required to be based on an occupant load factor of 200 gross square feet per person. In contrast, the required occupant load factor for a building used for public assembly is 15 net square feet per person. In contrast, the required occupant load factor for a building used for public assembly is 15 net square feet per person. This means the number of occupants in buildings used for public assembly is approximately thirteen (13) times greater than a typical open parking garage having the same floor area. Also, due to the much larger number of occupants, many more exits are required to allow the occupants to safely evacuate the assembly building.

MEANS OF EGRESS CONTINUED  Capacity (Width) of Exit Stairs Since buildings used for assembly have thirteen (13) times the number of occupants than a parking garage, the dimensional size or widths of the exit stairs must also be much greater than those used in parking garages.

MEANS OF EGRESS CONTINUED  Exit Stair Enclosures All stairs serving a building used for public assembly are required to be enclosed within two (2)-hour fire-resistant-rated shaft enclosures. In contrast, stairways that serve an open parking garage are allowed to be unprotected and completely open.

MEANS OF EGRESS CONTINUED  Ceiling Height A building used as a parking garage is allowed a clear ceiling height of only 7 feet in the vehicle and pedestrian traffic areas. A building used for public assembly must maintain a minimum ceiling height of 7 feet 6 inches.

FIRE PROTECTION SYSTEMS Automatic fire sprinkler systems are not required to be installed in open parking garages, regardless of the height or area of the garage. However, the Building Code requires an automatic fire sprinkler system to be installed throughout a building used for assembly, if the building exceeds 5,000 square feet in area or if the number of occupants exceeds 300 people. Sprinklers are always required if the assembly use is located on an elevated floor level or within a basement not having direct access to the exterior of the building.

FIRE PROTECTION SYSTEMS CONTINUED Fire alarms and other fire alarm/occupant notification systems are not required for open parking garages. However, a fire alarm system is required for any building used for public assembly, if the number of occupants exceeds 300. If the number of occupants exceeds 1,000, then the building would also be required to have an emergency voice/alarm communication system installed throughout.

PLUMBING FIXTURE COUNTS A minimum number of plumbing fixtures such as water closets, lavatories, drinking fountains, and service sinks, is not required for open parking garages. However, the Building Code requires a large number of plumbing fixtures in buildings used for assembly due to the extremely large number of building occupants.

ACCESSIBILITY Handicap accessibility requirements of the Building Code must also be met for any building used for public assembly. These requirements include an accessible means of egress, accessible routes throughout the building, accessible entrances, accessible bathroom facilities, accessible drinking fountains and unisex toilets and bathing rooms.

ACCESSIBILITY CONTINUED There are significant differences between the accessible means of egress requirements for an assembly use and those required for an open parking garage. Areas of refuge are not required at exit stairways or elevators serving open parking garages. Buildings used for assembly must have an accessible means of egress. This requires that the exit stairways contain an area of refuge (an enlarged floor-level landing). Similarly, to be considered part of an accessible means of egress, an elevator must be accessed from either an area of refuge or from a horizontal exit.

ELEVATORS Enclosed elevator lobbies are not required for elevators serving open parking garages. However, if an assembly use is added to an existing open parking garage, then the elevator is required to be enclosed in a fire-resistance rated shaft enclosure and if the elevator shaft connects more than three stories, then an enclosed elevator lobby would be required at each floor.

SPECIAL REQUIREMENTS There are special electrical, mechanical and plumbing design requirements for any building used for public assembly. The most significant requirements are for the required smoke control systems and for emergency and standby power. These emergency power systems are necessary to ensure the smoke control systems work if the building should lose power and also to have sufficient lighting to allow the occupants to exit the building.

The Building Code does contain “special provisions” for new buildings designed for mixed uses; such as buildings having separate areas within the same building to be used for both an open parking garage and for assembly. These “special provisions” are subject to specific conditions. There are two different design approaches as to how the mixed- occupancies are to be separated: MIXED-USE PROVISIONS FOR A NEW BUILDING

MIXED-USE PROVISIONS FOR A NEW BUILDING CONTINUED  Non-separated Occupancies Under this design approach, fire-resistance rated separations are not required between the different uses (occupancies). Each occupancy in the building is individually classified and code requirements are applicable to each portion of the building based on the occupancy classification of that space; however, the most restrictive applicable provisions Section 403 (high-rise requirements) and Chapter 9 (fire protection systems) must be used for the entire building. Further, the allowable height and area of the building must be based on the most restrictive allowances of the occupancy groups under consideration.

MIXED-USE PROVISIONS FOR A NEW BUILDING CONTINUED  IBC Section – Separated Occupancies Under this design approach, each occupancy in the building is individually classified, and the individual occupancies must be separated from the adjacent occupancies by fire-resistance rated walls/floors in accordance with the Building Code. Each fire area then must comply with the applicable code requirements based on the occupancy classification of that portion of the building.

SUMMARY The Clark County Building Division has significant concerns regarding the potential risks to the life safety and welfare of the building occupants, if a parking garage building is not brought into full compliance with all current code requirements for buildings used for public assembly.