Study of plastic scintillators for fast neutron measurements

Slides:



Advertisements
Similar presentations
Topic 8. Gamma Camera (II)
Advertisements

NUCP 2371 Radiation Measurements II
Advanced Neutron Spectrometer (ANS) Geant4 Simulations
Dante Nakazawa with Prof. Juan Collar
Neutron detectors and spectrometers 1) Complicated reactions → strong dependency of efficiency on energy 2) Small efficiency → necessity of large volumes.
Gamma-Ray Spectra _ + The photomultiplier records the (UV) light emitted during electronic recombination in the scintillator. Therefore, the spectrum collected.
PET Design: Simulation Studies using GEANT4 and GATE - Status Report - Martin Göttlich DESY.
DESCANT and  -delayed neutron measurements at TRIUMF Paul Garrett University of Guelph.
Chapter 8 Planar Scintigaraphy
Detection of Gamma-Rays and Energetic Particles
Search for spontaneous muon emission from lead nuclei with OPERA bricks M. Giorgini, V. Popa Bologna Group OPERA Collaboration Meeting, LNGS, 19-22/05/2003.
BME 560 Medical Imaging: X-ray, CT, and Nuclear Methods
Pion yield studies for proton drive beams of 2-8 GeV kinetic energy for stopped muon and low-energy muon decay experiments Sergei Striganov Fermilab Workshop.
Introduction to Hadronic Final State Reconstruction in Collider Experiments Introduction to Hadronic Final State Reconstruction in Collider Experiments.
Simulations with MEGAlib Jau-Shian Liang Department of Physics, NTHU / SSL, UCB 2007/05/15.
AGATA Demonstrator Test With a 252 Cf Source: Neutron-Gamma Discrimination Menekşe ŞENYİĞİT.
Planar scintigraphy produces two-dimensional images of three dimensional objects. It is handicapped by the superposition of active and nonactive layers.
Gamma Spectroscopy HPT TVAN Technical Training
30 Ge & Si Crystals Arranged in verticals stacks of 6 called “towers” Shielding composed of lead, poly, and a muon veto not described. 7.6 cm diameter.
Radiation therapy is based on the exposure of malign tumor cells to significant but well localized doses of radiation to destroy the tumor cells. The.
Stopping Power The linear stopping power S for charged particles in a given absorber is simply defined as the differential energy loss for that particle.
1 The Study of D and B Meson Semi- leptonic Decay Contributions to the Non-photonic Electrons Xiaoyan Lin CCNU, China/UCLA for the STAR Collaboration 22.
HIM 2009 spring Development of the Scintillation-fiber Detector for the Neutron-Beam Profile Measurement C. Kim,* B. Hong, R. J. Hu, M. Jo, K. S. Lee,
1 Scintillators  One of the most widely used particle detection techniques Ionization -> Excitation -> Photons -> Electronic conversion -> Amplification.
Radiation Detection and Measurement, JU, First Semester, (Saed Dababneh). 1 Spectrum if all energy is captured in detector. Allows identification.
Abstract A time resolved radial profile neutron diagnostic is being designed for the National Spherical Torus Experiment (NSTX). The design goal is to.
Study of plastic scintillator quenching factors Lea Reichhart, IOP Glasgow, April /17.
A scintillation detector for neutrons below 1 MeV with gamma-ray rejection Scintillators are 3 mm BC408, 10 layers total Adjacent layers are optically.
CRESST Cryogenic Rare Event Search with Superconducting Thermometers Max-Planck-Institut für Physik University of Oxford Technische Universität München.
Interactions of Neutrons
Gamma Ray Imaging Lab Tour
SNS neutron background measurements using a portable 3 He LPSD detector.
1 Dosimetry part 1: X-ray interactions with matter G.Haddadi, PhD, MSc Associated prof. of Medical Physics Fassa University of Medical Sciences.
Neutron scattering systems for calibration of dark matter search and low-energy neutrino detectors A.Bondar, A.Buzulutskov, A.Burdakov, E.Grishnjaev, A.Dolgov,
Digital analysis of scintillator pulses generated by high-energy neutrons. Jan Novák, Mitja Majerle, Pavel Bém, Z. Matěj 1, František Cvachovec 2, 1 Faculty.
Geant4 Simulation of Neutrons interaction with GEM-foil and gas Gabriele Croci, Matteo Alfonsi, Serge Duarte Pinto, Leszek Ropelewski, Marco Villa (CERN)
Alpha and Beta Interactions
Spectra of the Thunderstorm Correlated Electron and Gamma-Ray Measured at Aragats Bagrat Mailyan and Ashot Chilingarian.
Simulation of the energy response of  rays in CsI crystal arrays Thomas ZERGUERRAS EXL-R3B Collaboration Meeting, Orsay (France), 02/02/ /03/2006.
NESTOR SIMULATION TOOLS AND METHODS Antonis Leisos Hellenic Open University Vlvnt Workhop.
Passive detectors (nuclear track detectors) – part 2: Applications for neutrons This research project has been supported by the Marie Curie Initial Training.
Radiochemistry Dr Nick Evans
1 Performance of a Magnetised Scintillating Detector for a Neutrino Factory Scoping Study Meeting Rutherford Appleton Lab Tuesday 25 th April 2006 M. Ellis.
Experimental Nuclear Physics Some Recent Activities 1.Development of a detector for low-energy neutrons a. Hardware -- A Novel Design Idea b. Measure the.
Backscatter neutron spectrometer. Rad Inter Neutrons W. Udo Schröder, Nuclear Interactions of Neutrons Characteristic secondary nuclear radiation/products:
Determining Radiation Intensity
A search for strange tribaryonic states in the reaction Heejoong Yim Seoul National University For KEK-PS E549 collaboration.
Study of high energy cosmic rays by different components of back scattered radiation generated in the lunar regolith N. N. Kalmykov 1, A. A. Konstantinov.
Validation of EM Part of Geant4
00 Cooler CSB Direct or Extra Photons in d+d  0 Andrew Bacher for the CSB Cooler Collaboration ECT Trento, June 2005.
1 Study of Data from the GLAST Balloon Prototype Based on a Geant4 Simulator Tsunefumi Mizuno February 22, Geant4 Work Shop The GLAST Satellite.
Second Workshop on large TPC for low energy rare event detection, Paris, December 21 st, 2004.
ArgonneResult_ ppt1 Comparison of data and simulation of Argonne Beam Test July 10, 2004 Tsunefumi Mizuno
Energy Reconstruction in the CALICE Fe-AHCal in Analog and Digital Mode Fe-AHCal testbeam CERN 2007 Coralie Neubüser CALICE Collaboration meeting Argonne,
Introduction to Hadronic Final State Reconstruction in Collider Experiments Introduction to Hadronic Final State Reconstruction in Collider Experiments.
Forschungszentrum Karlsruhe Erice, 7th July th International School for Cosmic Rays Astrophysics Motivation Energy Reconstruction Air Fluorescence.
Optimization of Scintillators for Stacked-layer Detectors of FNGR 1,2 Jea Hyung Cho, 1,2 Kwang Hyun Kim *, and 3 Young Hyun Jung 1 Biomedical Engineering,
WIMPs Direct Search with Dual Light-emitting Crystals Xilei Sun IHEP International Symposium on Neutrino Physics and Beyond
1Malcolm Ellis - G4 Physics Validation Meeting - 17th July 2006 MuScat Validation of G4  Muon Scattering (MuScat) Experiment u Motivation: Ionisation.
Fast neutron flux measurement in CJPL
Sensitivity of Hybrid Resistive Plate Chambers to Low-Energy Neutrons
Development of a Compton Camera for online range monitoring
Dr. Mikhail Runtso, Mr. Pavel Naumov,
AQUA-ADVANCED QUALITY ASSURANCE FOR CNAO
Single trigger, no target
Neutron Detection with MoNA LISA
Gamma-Gamma Correlations in Na-22
Litao Zhao Liaoning University&IHEP
Deng Ziyan Jan 10-12, 2006 BESIII Collaboration Meeting
A Neutron Counter for the CLAS12 Central Detector
Presentation transcript:

Study of plastic scintillators for fast neutron measurements Mihee Jo*, B. Hong, R. J. Hu, C. Kim, K. S. Lee Nuclear Physics Laboratory Korea University

Contents Introduction & motivation Experimental setup Pulse analysis GEANT4 simulation Potential application to the neutron camera Conclusions

Introduction & motivation Fast neutrons are applied for the treatment of the human cancers, material science and biology. Neutrons have a higher biological effectiveness than both photons and protons. Neutrons are especially effective against advanced tumors like head, neck and prostate cancer. 왼쪽 아래 : 1975 년에 Fermilab에서 Linac을 만든 Don young 이라는 과학자의 모습. 오른쪽 : Fermilab의 neutron therapy facility에서 치료를 위해 뇌 영상을 관찰하는 모습. Northern lllinois 대학의 medical director.

Introduction & motivation Neutron radiography is used to find out slight defect in materials. Comparison of X-Ray and Neutron Radiography X-ray는 널리 사용되어왔지만, 크기 감쇄정도가 밀도가 높은 물질일수록 커지고, x-ray가 통과 가능한 얇은 물질에 대해서만 사용될 수 있었다. 중성자는 꽤 두꺼운 금속 물질들도 쉽게 통과할 수 있다. 그래서 사진으로 찍으면 그냥 통과한 부분은 어둡고, 다른 가벼운 원자로 만들어진 물질들이 통과한 부분은 밝게 찍힌다.

Introduction & motivation Fast neutron – proton elastic scattering can be applied to reconstruction of the neutron tracks emitted from sources. Elastic scattering produces an energetic proton, which can be measured by proton-rich organic scintillators. It will be important to diagnose the characteristics of the plastic scintillators for the measurement of fast neutrons.

Experimental setup A 5μCi 252Cf was used for the energy measurements. Branching ratio for fission = 0.0309 Branching ratio for α-decays = 0.969 The fission decay was triggered by either neutron or γ-ray emitted from the fission fragments. Fission이 일어난 후 두 개의 fragment에서 평균 3.78개의 고속중성자와 2개의 감마선이 방출됨. 직선 화살표 : 스핀, 점선 화살표 : 중성자 방출

Experimental setup Case Ⅰ Case Ⅱ 2 scintillators were used for full absorption. Neutron events were triggered by trigger scintillator & primary scintillator. Case Ⅱ 4 layered scintillator with 1-cm-thick plate were used for high efficiency and resolution. Because of small detectable range, no collimator in front of the 4 layered scintillators. 60 cm

Experimental setup Neutron energy measured by the TOF T=Arrival time of neutron L=Distance between the source and the neutron detector Ts=Conversion factor of TDC (0.2651 ns/ch) T0=Time offset A가 calibration factor 인데, 실험을 통해서 얻은 값인지, 문헌에서 찾은 값인지? Ts : Scale factor of TDC T0 : trigger, primary 검출기 사이에 선원을 놓고 바짝 붙여서 측정한 절대적인 시간차이 Uncertainties for the neutron energy measurement Uncertainty of the flight distance caused by the finite thickness of the detectors. Uncertainty of the flight-time caused by finite time resolution of the test system.

Experimental setup Selection of the neutron energy : 2 < En< 7.5 MeV En > 7.5 MeV : the contamination of the gamma rays emitted from α and fission decays. En < 2 MeV : excluded to minimize the perversion in the neutron-energy spectra due to the threshold on the pulse height (30 mV). ADC channel Neutron energy (MeV) TDC channel Counts Neutron Energy (MeV) γ removed 삭제된 감마선은 primary 검출기에 감마선이 검출된 경우에 대한 것. (중성자보다 빨리 검출기에 도착한다)

Pulse analysis Pulse spectra of the fast neutrons (Case Ⅰ) Energy distribution of primary detector Energy is deposited partially. Energy distribution of secondary detector The rest energy is fully absorbed. Total energy distribution At higher neutron energies, energy resolution is worse, and distribution is broader.

Pulse analysis Neutron energy dependence of total light output (Case Ⅰ) Birk’s formula dL/dx : (light output) / (unit length) A : absolute scintillation efficiency kB, B : parameter relating the density of ionization centers to dE/dx Approximately linear, but small amount of non-linearity exist. Birk 식의 상수값들이 어떻게 계산된 값인지 알아보기. (다른 책에서 본 것과 단위가 다른 것 같음..) Astroparticle physics 논문의 proton scattering에 의한 값하고는 어떻게 비교할 수 있는건지? 그래프는 정확한 birk 식이 아님. En의 의미는 입사된 중성자의 에너지. Primary에 입사된 중성자의 에너지에 따른 신호의 세기를 보려고 한 것.

Pulse analysis Energy resolution of the D1 (Case Ⅰ) At higher neutron energies, poorer resolutions occur. The number of fully absorbed neutron decreases. Light collection efficiency decreases as multiple scattering increases. Any other reasons? Probably, other scattering processes affect the light yield.

GEANT4 simulation Sensitivities was predicted as a function of the neutron energy At higher neutron energies, n-12C scattering occurs more frequently. Total light yield can be reduced because the kB value for n-12C scattering is lager than n-p scattering. → Poorer resolutions! Case Ⅰ Case Ⅱ case 2는 부피가 작아서 full absorption 할 확률이 더 낮다. Efficiency : GEANT4에서 particle gun에서 나온 중성자가 각 경우마다 primary detector 등에 deposit 되는 효율

GEANT4 simulation Deposit energies of the fast neutrons and the comparisons to the pulse spectra Simulation’s peak becomes narrower in data Origin of discrepancies between the data and the simulations Difference in the light yields between p and 12C. The difference becomes larger at the lower neutron energies, because of the threshold effect. Case Ⅱ

Potential application to the neutron camera Neutron camera system with PSPMT The neutron camera is a useful detector to search for any hidden fast-neutron sources. The energy of recoil nucleus by neutron - nucleus elastic scattering Proton takes a half of neutron’s energy (A=1) → , The angle of the neutron track is We are developing the practical neutron camera as an application of the neutron detector. 양성자와 중성자의 질량이 근사적으로 같으므로 고전적인 산란 모형을 이용하면 중성자와의 탄성 산란에 의한 되튀김핵(recoil nucleus)의 에너지는 다음과 같이 주어진다. 유기검출기를 구성하는 주성분은 H와 C이다. 탄소의 경우 무겁기 때문에 탄성산란에 의한 되튀김 에너지가 작고 검출기 내에서의 탄성산란 신호가 매우 작다. 그러나 수소원자의 핵인 양성자의 경우 A = 1이므로 평균적으로 중성자 에너지의 절반을 가져가게 된다.

Conclusions We have measurement of the light yields and the pulse (energy) resolutions as a function of the neutron energy by the TOF method. The data have been compared with the GEANT4 simulations : The pulse resolution increased with the neutron energy. The spatial range for the absorption via the multiple scatterings increases as the neutron energy. The relative strength of n-12C to n-p in the elastic scattering accounts for the worse resolutions at higher energies. We are developing the neutron camera as a potential application.

Back up

Potential application to the neutron camera The resolution for the scattering angle to determine the neutron direction For example, 2m from neutron source material FWHM of scintillation fiber pixel is 0.35 → is 60 mrad → the diameter of a cone is 24㎝ If area of neutron scatter is 200 ㎠, with 0.2 ㎐ detection, neutron source material weighs about 100 kg.

References Page 3 : www.symmetrymagazine.org/cms/?pid=1000102 Original paper : JKPS 2009 54:586-591