Sample Preparation and Mapping Steps –Cleaning and drying of bulk samples –Initial Preparation. Cutting, impregnation, cast- making, fusing –Mounting.

Slides:



Advertisements
Similar presentations
Use lenses to direct light in order to enlarge images
Advertisements

Sample Preparation – IR spectroscopy
Processes Used to Finish Wood Materials
MarineMend Repair Kit Procedure
Sample Preparation Electron Microprobe samples must be: 1) Solid 2) Flat 3) Well polished (1 micron polish or better) 4) Low vapor pressure 5) Conductive.
Chapter 6: MICROTOMY Learning Objectives:
Anodic Aluminum Oxide.
TEM 試片的準備技術 授課老師:王聖璋 博士 班級:車輛四乙 學號: 學生:陳維翰 報告日期:2013年12月27日.
Flexographic Tapes 3M Industrial Business 3 3M™ Cushion-Mount™ Plus Tapes with Easy Mount Adhesive.
Copyright © 2005 SIFCO Industries, Inc. Visual Keys For Successful Base Material Preparation.
Machine Tools And Devices For Special Technologies Plasma machining Slovak University of Technology Faculty of Material Science and Technology in Trnava.
© 2012 Delmar, Cengage Learning Cleaning Equipment and Methods Chapter 10.
PRESENTATION ON CLEANING VALIDATION INDEX  INTRODUCTION SIGNIFICANCE SELECTION OF SAMPLING TECHNIQUES ESTIMATION OF ACCEPTANCE CRITERIA RE-VALIDATION.
Module 8: Painting GRP. Why is GRP so difficult to paint? Issue 1: Mould release agents In order to release GRP panels easily from their mould, a coating.
Emre Ertuğrul Emin Şahin Seçkin Gökçe KMU 396 Material Science and Technology.
What are you looking for? Topography? –Is the surface dirty? –Are you looking for the clean surface or the dirt? –If the dirt, no preparation is required!
Scanning Electron Microscope Jamie Goings. Theory Conventional microscopes use light and glass lenses SEM uses electrons and magnetic lenses to create.
Sample Preparation or Sample Prep. Always Handle samples with GLOVED HANDS!
ED and WD X-ray Analysis
Using a Microscope Many things are smaller than we can see with the naked eye. To accurately study Biology we need a tool to help us see these tiny things.
+ Research Techniques I (Biology 513) Tissue processing.
Do it with electrons !. Microscopy Structure determines properties We have discussed crystal structure (x-ray diffraction) But consider now different.
Introduction to Operation of the XL- 30 Scanning Electron Microscope Tutorial # 2 Introduction to Operation and Imaging.
Collagraphy Materials. Base Plate The base plate is the foundation on which the artist will be applying other materials to create a collage. The base.
O RBIS — Micro-EDXRF System. XRF Advantages Non-destructive: No beam damage or coating of sample Minimal Sample Preparation: conductivity not required.
Electron probe microanalysis - Scanning Electron Microscopy EPMA - SEM
GLAZING 101 Ceramics 1 Waverly-Shell Rock HS. GLAZE IS… A liquid suspension of finely ground minerals which is applied on the surface of bisque fired.
Meteorite 101 Cutting, Surface Preparation, Etching, and Preserving Iron Meteorites Prepared for AOAS By Leonard Lynch.
General Semiconductor Packaging Process Flow
Collection, Preparation
SEM (SCANNING ELECTRON MICROSCOPE) Özgen Buğdaycı Elif Topçuoğlu Yavuz Duran Hacettepe University
Quantitative Analysis Quantitative analysis using the electron microprobe involves measuring the intensities of X-ray lines generated from your unknown.
I.C. Technology Processing Course Trinity College Dublin.
Everything You Wanted to Know But Were Afraid to Ask
Metallographic Sample Preparation and Examination Prepared by: Mahmoud R.M.Abusrea Teaching Assistant, MDP Dept. October,2008.
Microscopes SC.912.L.14.4 Compare and contrast structure and function of various types of microscopes.
NANO 225 Micro/NanoFabrication Electron Microscopes 1.
Preparation of cross-section TEM specimen on sapphire substrate
Conventional SEM Specimen at high vacuum – requires sample fixation and dehydration or freezing. Charging is minimized by coating sample with metal or.
SEM Scanning Electron Microscope
Principles of Manufacturing Copyright © Texas Education Agency, All rights reserved 1.
MPRI Centralised Laboratories Gerrard Peters School of Physics 1.
HPLC.
IDdesign Academy MORE EDUCATION – MORE KNOWLEDGE – MORE SALES Leather 1 Furniture leather.
Polypterus senegalus SEM Imaging Sample Preparation Protocol Sample Imaging Parameters -Scales were embedded in resin and cured at 60˚ C for 16 hours -Embedded.
COURSE: 322-HISTOLOGICAL TECHNIQUE
1 of 13 Mark Tillack, John Pulsifer, Sam Yuspeh, Matt Aralis HAPL Project Meeting October 2008 Madison, WI Progress on GIMM mirror development and.
Dye Solar Cell Assembly Glass handling Titania deposition Sintering process Sensitizer impregnation Platinum deposition Sealing electrodes Electrolyte.
Geochemistry of Pyrite and Whole Rock Samples from the Getchell Carlin –type Gold Deposit, Humboldt County, Nevada Tim A. Howell and Jean S. Cline University.
Chapter 1: The Nature of Analytical Chemistry
Scanning Transmission Electron Microscope
Do it with electrons !. Microscopy Structure determines properties We have discussed crystal structure (x-ray diffraction) But consider now different.
Tools of a Scientist and Introduction to the Microscope
Preparation Stationary Sample Holders
Exp.1: Preparation of Specimens for Metallographic Examination
Grinding Grinding is a process which utilizes the use of abrasive particles bounded together to produce superior surface finishing An abrasive: is a small,
Chemical and Electro-Chemical Energy Based Processes
Chemical and Electro-Chemical Energy Based Processes
Antirust Properties of Petroleum Products by NACE Corrosion
Preface: What’s EPMA all about? How does Geology 777 work?
Electron Probe Sample Preparation The Hebrew University of Jerusalem
Preparation of Samples
Preparation of Specimens for Metallographic Examination
Thermal Outgassing Rate for Various Beam Line Materials
Cell Biology Practical TEM&SEM
Insulators and Conductors
Do it with electrons !.
Optical Metallography. Metallography is the study of the physical structure and components of metals, by using microscopy. Introduction.
Sample Preparation and Mapping
Volume 110, Issue 4, Pages (February 2016)
Presentation transcript:

Sample Preparation and Mapping Steps –Cleaning and drying of bulk samples –Initial Preparation. Cutting, impregnation, cast- making, fusing –Mounting. Stubs, embedded samples, thin sections, grain mounts –Polishing. For quantitative analysis –Cleaning –Mapping –Coating –Handling and storage

Preparing Bulk Samples Initial Prep: –Remove organic material with oxidizing agent such as K-permanganate or H 2 O 2 –Rinse sediments or soils to remove soluble salts and fines if desired –Carbonate can be removed with HCl –Remove hydrocarbons by soaking in trichlorethane

Drying: –Wet samples must be oven- or freeze-dried before introduction into the instrument. Be aware that temperatures of over 50 o C can remove structural water from clay minerals. –Rock samples that have been cut using a saw should be thoroughly dried prior to mounting.

Initial Preparation Cutting –Large samples must be cut to thin-section size, or cut or broken to a appropriate size for an SEM stub. Typically, diamond-blade circular saw is used. Friable samples may need to first be impregnated. Impregnating –Friable or porous samples should be vacuum impregnated prior to sample prep. Loose material on the sample surface can cause contamination of the electron column, and unimpregnated porous samples can cause poor vacuum by prolonged outgassing. Cast-making –SEM visualization of pore structure can be facilitated by vacuum impregnating a sample, followed by dissolution of the sample material using hydrofluoric acid. Topographic details of small fossils can also be facilitated by producing latex cast Fusing –Bulk analyses of fused rock samples can be made using EMPA techniques. Samples and standards should be fused using the same procedure.

Mounting SEM Stubs: –SEM samples can be mounted onto Al or C stubs. C can be used for low X-ray background in the case of particulate analysis. Mounting can be done using epoxy, quick-setting glue, double-stick tape (mostly for particulates) or wax. Small grains can be mounted onto double-stick tape or partially dried carbon or silver paint.

Quantitative Analysis Preparation Embedding, Thin Section, Grain Mounts These are the most common techniques for preparation of geological samples.

Sample holders

Polishing a sample to a flat, unscratched surface is CRITICAL for good quantitative analysis. An uneven, or scratched sample surface can lead to uneven production of x-rays from the sample surface, errors in absorbtion correction, and spurious results. Polishing

The polishing steps needed for a sample depends on the types of material present. Metallic phases typically polish very easily, whereas minerals with strong cleavage can be problematic. A typical polishing procedure would be as follows: Grinding the sample to a flat surface, using 100, 260, and 600 mesh grit diamond wheels, or equivalents. Wash sample in water Polishing the sample using 30 micron diamond grit (600 mesh) for 3 minutes. Ultrasonically clean sample in deionized water Polish the sample using 6 micron diamond grit for 3 minute Ultrasonically clean sample in deionized water Polish the sample using 1 micron diamond grit for 3 minutes Ultrasonically clean sample in deionized water Polish the sample using 0.5 micron diamond grit for 1 minute Ultrasonically clean sample in deionized water Polishing

Cleaning Any contaminating material, particularly skin oil, on the sample surface will end up contaminating the column. Also, contaminating material under the conductive coating of a sample can cause the conductive coating that will be placed on the sample to bubble and crack, making the sample impossible to analyze KEEP THE SAMPLE CLEAN AND OIL FREE!!! 1. After final polish, clean the sample ultrasonically with deionized water 2. Wipe the sample surface with petroleum ether. 3. Following the petroleum ether cleaning, handle the sample as carefully as possible. Glove handling is ideal, but often inconvenient. An alternative is to handle the sample with a kimwipe, or other lint-free papr or cloth. 4. Blow the sample off with air prior to coating.

Finding analysis areas on a sample using the optical microscope or electron imaging can be difficult because of the small field of view. The maximum optical field of view for our instrument is 1750 microns (1.75 mm), and the maximum electron image field is around 2500 microns (2 mm). So, having a good sample map, particularly for quantitative analysis, is very important. Sample mapping is much less important for SEM work. Two types of map may be useful, depending on you sample. 1. Macro-map. Map of entire section. Depending on sample type, this may be hand- sketched, made with a slide copier, or with an enlarging xerox machine. 2. Micro-map. Map of areas of analytical interest. This needs to be produced with a camera-equipped microscope, and can be used to locate and document exact analytical spots. A micromap can also be produced using the microprobe. You can also mark areas of interest on your sample, but this must be done on a clean sample surface prior to applying the conductive coat. Mapping

Sample Coating Many geological samples are nonconductors of electricity. Therefore, if an uncoated sample is placed in the path of the electron beam, the sample will charge, causing deviation of the electron beam, as well as catastrophic decharging. The sample must be coated with conductive material, such as carbon, gold, or gold-palladium alloy. CARBON: For quantitative analysis and X-ray mapping, carbon is the coat of choice. Because of its low Z, it has a minimal effect on the X-ray spectrum, either in terms of producing X-ray lines or absorbing X-rays. A carbon coat is applied using a vacuum evaporator at pressures of less than torr. The ideal coating thickness is 20 nm. GOLD: Gold can be a better choice for SEM coating because of its higher secondary electron yield.