Experiences of using the Philips CardioMD Camera University Hospital Birmingham Foundation NHS Trust.

Slides:



Advertisements
Similar presentations
CLEARSPACE Digital Document Archiving system INTRODUCTION Digital Document Archiving is the process of capturing paper documents through scanning and.
Advertisements

A Novel Solution to Large Volume Data Storage Nicholas Tulley City Hospital, Birmingham Department of Physics & Nuclear Medicine.
Lab made 8.0 Clinical Labs Software For Clinical Labs to Generate accurate test reports, Maintain record of patients, Easy to handle, Fast Implementation,
Impact of various imaging modalities on PACS archiving and storage Eugene Mah, M.Sc. Jay Crawford, MHA Medical University of South Carolina.
Gamma Camera Quality Control
MedArt ® 456 The most advanced scanning system for facial skin resurfacing available.
PACS In Nuclear Medicine Practical Experience from the Cromwell Perspective.
Summit E & Summit XL Dispensers for small OPL to large laundry washer extractors and tunnels.
IPP & AFA vs. Axiovision Strong points of Cell Observer system: Zeiss name, Zeiss’s success in high-end application, especially in LSM, gives them very.
D.I.Y Dicom Server! J. O’Brien Department of Physics and Nuclear Medicine, City Hospital, Birmingham Sandwell and West Birmingham Hospitals NHS Trust.
James R. Halama PhD, Medical Physicist David A. Urani MBA, CNMT, Manager Rebecca A. Sajdak BA, CNMT, Sr. Technologist Robert H. Wagner MD A Program for.
QC And NEMA In The Nuclear Arena
Picture Archiving And Communication System (PACS)
+ Photoshop – Monitor and Printer Calibration! Drycreekphoto.com.
COMPUTED TOMOGRAPHY - I RAD 365 CT - Scan
Introduction to Software Installation:  Installation of Real Estate Management System is very easy and User friendly.  Software gets Installed in very.
Airborne LIDAR mapping tools, technology, trends, outlook ASPRS Annual Conference – PDAD Airborne LIDAR Mapping Technology Panel April 30, 2008 Please.
Who Is MEDX? Leading provider of nuclear medicine equipment, service and parts since 1973 Delivered over 3,000 systems worldwide Facility is FDA-compliant.
CSE 321b Computer Organization (2) تنظيم الحاسب (2) 3 rd year, Computer Engineering Winter 2015 Lecture #4 Dr. Hazem Ibrahim Shehata Dept. of Computer.
FDG-PET/CT Technical Committee
Rhonda Draper, RN Director of Clinical Care Services Mona Reimers, FACMPE, CPC Director of Revenue Services BETTER DATA, BETTER DECISIONS.
A HIGH RESOLUTION 3D TIRE AND FOOTPRINT IMPRESSION ACQUISITION DEVICE FOR FORENSICS APPLICATIONS RUWAN EGODA GAMAGE, ABHISHEK JOSHI, JIANG YU ZHENG, MIHRAN.
GEH M IT! Web Page Editor Introduction. Basic types of web editors Web page editors can be divided into two basic groups: WYSWIG HTML Editors WYSWIG HTML.
Cobian Backup 7 Tutorial Welcome to Cobian Backup 7. This tutorial will show you how to install the program, configure it and create your first scheduled.
1 Maintain System Integrity Maintain Equipment and Consumables ICAS2017B_ICAU2007B Using Computer Operating system ICAU2231B Caring for Technology Backup.
Brought to you by powerpointpros.com Play. 1.Advance to Round 1. 2.A question will be shown on the screen. You will have 30 seconds to answer it by choosing.
Chapter © 2006 The McGraw-Hill Companies, Inc. All rights reserved.McGraw-Hill/ Irwin Chapter 7 IT INFRASTRUCTURES Business-Driven Technologies 7.
Imaging Core Laboratory Fall Meeting, 2011 Imaging Challenges for ACRIN sites Compliance and set-up Anthony M. Levering Assistant Director, Core lab.
INTRODUCTION UTUBUNTU Why use Ubuntu for desktops? Ubuntu is a Fast, Secure and Easy-to-use operating system used by millions of people around.
PACS, FILMLESS RADIOLOGY AND TELERADIOLOGY -A FUTURE PERSPECTIVE KMA annual scientific conference at Noble hotel Eldoret April 22 nd -2th 2015 OUR EXPERIENCE.
NumaStore Nuclear Cardiology P.E.T. Nuclear Medicine Image Management Solution Mini-PACS for Nuclear Medicine Archiving and Data Management.
Create Lists in Millennium Jenny Schmidt SWITCH Library Consortium.
ICNet – application to practice DAVID TUCKER – DEPUTY DIRECTOR INFECTION PREVENTION AND CONTROL, GUY’S & ST THOMAS’ NHS FOUNDATION TRUST.
Practical Image Management for Pharma Experiences and Directions. Use of Open Source Stefan Baumann, Head of Imaging Infrastructure, Novartis.
Who Is MEDX? Leading provider of nuclear medicine equipment, service and parts since 1973 Delivered over 3,000 systems worldwide Facility is FDA-compliant.
Business process changes due to SIS. The principal component of SIS is removal of paper from the billing and settlement process, but it’s much more –
Nuclear Medicine Physics
AS ICT.  Have an understanding of how organizations use ICT.  Be able to describe a number of uses, giving the hardware and software requirements 
Motion Correction Riku Klén
EagleSoft Version 15 Installation Patterson Imaging Version _Attachment_A_Rev.1_ Revision 1Revision Date: 1/18/12.
Skylight for a Small Nuclear Medicine Department Mr Anil Vara Queen Mary’s Hospital London.
1 Nuclear Medicine SPECT and PET. 2 a good book! SR Cherry, JA Sorenson, ME Phelps Physics in Nuclear Medicine Saunders, 2012.
Keeping Updated Ensuring hospital IT systems support ePortfolio.
T3g software services Outline of the T3g Components R. Yoshida (ANL)
DICOM in Dart (DCMiD) Computer Integrated Surgery II, Spring 2014, Project 13 Damish Shah and Danielle Tinio, under the auspices of Dr. James Philbin Introduction.
PET Imaging Positron Emission Tomography
Nuclear Medicine Physics
Single Slice Spiral - Helical CT
Hybrid Head motion correction in PET/MR Brian Imaging
On-Site PBX Vs Hosted PBX.
Storage tank scanning with Trimble TX5 Scanner and Storage Tank Application Filip Jinnestrand, 2013.
Advances in Imaging Instrumentation for Nuclear Cardiology
Magnetic Resonance Imaging (MRI) Systems Market to grow at 7% CAGR from 2017 to 2024
CLRS 321: Nuclear Medicine Physics and Instrumentation I
OPERATING SYSTEMS.
Electronic Staff Rehire
Joe O’Brien & Bill Thomson, City Hospital, Birmingham
Intrinsic Uniformity QC Setup
The evaluation of clinical usefulness on application of Half-time acquisition factor in Gated Cardiac Blood Pool scan Dong-Hun Lee.
The Radiology Information System (RIS)
Presentation transcript:

Experiences of using the Philips CardioMD Camera University Hospital Birmingham Foundation NHS Trust

Why choose a dedicated Cardiac camera?  Three cameras were routinely used before the CardioMD was installed: Dual Head (ADAC Vertex) used for MPI Single Head Large FOV (Toshiba) Single Head Small FOV (Siemens)  Plan was to replace the small FOV camera with a dedicated Cardiac Camera because:  MPI requests were growing  A dedicated cardiac camera has a smaller footprint than a modern SPECT-CT system  Money was available from the PCT for a dedicated Cardiac Camera (£190k)!

Why Choose the CardioMD?  Three dedicated Cardiac cameras were considered: Philips CardioMD (AC available) Siemens C-cam (AC available in future) Pulse IS2 (AC available in future)  Specifications similar between systems.  The Philips CardioMD was chosen primarily due to the availability of AC. The department had performed AC on MPI scans since  The CardioMD was also the cheapest!

Changes to Service in Department  Change in workflow for each camera  Dual Head (ADAC Vertex) Free for work other than MPI  Single Head Large FOV (Toshiba) Used for studies performed on the old small FOV camera replaced with CardioMD  CardioMD (Philips) Used for MPI and MUGA studies  The CardioMD has doubled the MPI scanning capacity and a full 5 day service can now be provided. (~550  ~1100patients/Yr)

Setting up a Study  Easy and quick to set- up an acquisition on the system.  However, since the introduction of the DICOM work list, there have been a few problems. Repetition of patient files. Handling of attenuation correction data

Positioning the Patient  Patients have difficulty both in getting on and off the bed.  Staff complain about bed not moving up or down.  Positioning has to be precise as the bed translates by a small amount.  Easy to set-up once patient is in position  However, range limits on very small or very large patients.

Image Reconstruction/Processing  Fast reconstruction/ processing software.  Motion correction software is quick and effective.  Software could be more intuitive. Some technologists report that they have to read manual/protocol on some occasions!

Routine QC ( 57 Co Daily Flood)

Routine QC ( 99m Tc Intrinsic Flood)  30M counts acquired using ~30MBq 99m Tc (~15min/head)  Integral uniformity results calculated and plotted

Weekly Intrinsic Uniformity Results

Routine QC (COR)  Easy to set-up.  X range values considered to be satisfactory.  Y range values considered to be good.

Summary  Pros Camera easy to use and reliable (since installation of UPS) System is relatively easy to maintain (e.g. PM tube retune) Quick and easy to use acquisition and reconstruction software Good motion correction software  Cons Most significant problem with the system is regarding ergonomics of the bed. Several problems with acquiring data following introduction of the DICOM work list. Set-up would be easier if an ‘OK’ button was present on the handset. Manual collimator exchange can be awkward