1 LITTELFUSE STARTCO Littelfuse Startco Arc Flash Relay PGR-8800.

Slides:



Advertisements
Similar presentations
Murray State University
Advertisements

Electrical Safety.
1S25 Arc Fault Monitor. 1S25 Arc Fault Monitor 1S25 Arc Fault Monitor Electrical arc short circuits in metal clad switchgear may occur for many different.
 ELECTRICAL SAFETY Gerald P. Robinson Jr., P.E. – Hatch Mott MacDonald.
Electrical Safety 29 CFR I. Background for the Trainer:
Protection and Relay Schemes. Agenda  Introduction of Protective Relays  Electrical System Protection with Protective Relays  Conclusion.
I’ll Be Done in a Flash! An Arc-blast Incident Presented by:
CHREID 2008 ELECTRICAL SAFETY Introduction and Overview of Safety Clayton H. Reid September, 2010.
CHEM 521 Safety Presentation. Hazard Symbols You Must Know.
FHM TRAINING TOOLS This training presentation is part of FHM’s commitment to creating and keeping safe workplaces. Be sure to check out all the training.
Graphic Symbol Location 1. DIN Terminal X52 The machine is powered by electricity using copper cable with 5 wires (3 phase wires + neutral wire +
OSHA Office of Training and Education
Young Worker Safety Resource Center, adapted from OSHA Office of Training and Education Electrical Safety.
San Bernard Electric Cooperative, Inc. Arc Flash Assessment.
Electrical Safety and Grounding Essentials Copyright © Texas Education Agency, All rights reserved.
ARC FLASH ANALYSIS.
Mr.A.R.ANBARASA AGM - Electrical GHCL Limited (Unit : Sree Meenakshi Mills )
Arc Flash Energy & Protection Presented by EWB Engineering (Electrical Engineers)
OSHA Office of Training and Education
Reducing Arc Flash Hazard in 3Ø Pad Mounted Transformers and Other Safety Considerations Presented at Western Energy Institute October 12, 2010 Christian.
What is Arc Flash? Arc flash is a short circuit through air that flashes over from one exposed live conductor to another conductor or to ground. Arc flash.
 Recognize the scope and structure of the OSHA standards.  Identify the common electrical hazards in long term care settings.  Discuss electrical safety.
Qualified Persons Working On Or Near Energized Equipment
Electrical Safety: Are you Prepared?
Circuit Protection Electrical circuits require protection to prevent fire or electrocution in the event of a fault. There are two main types of circuit.
Union College EHS Training 1 Electrical. 2 Introduction An average of one worker is electrocuted on the job every day There are four main types of electrical.
Electrical Safety This material was produced under a grant (SH22249SH1) from the Occupational Safety and Health Administration, U.S. Department of Labor.
BUILDING TRADE SAFETY ELECTRICAL SAFETY.
ELECTRICAL SAFETY OSHA 29 CFR 1910 SUBPART S
Incident Energy Study Christian Brothers University MAESC CONFERENCE Jermichael Beaver, Bruce Luong, David Temple, and John Ventura.
Electrical Safety INSTRUCTOR’S NOTES:
Electrical Safety Training
Electrical This presentation is designed to assist trainers conducting OSHA 10-hour General Industry outreach training for workers. Since workers are.
Electrical Safety INSTRUCTOR’S NOTES:
Electrical Safety INSTRUCTOR’S NOTES:
Mrs. Brinston. a. Electrical malfunction is the second leading cause of fires in hospitals. b. Fortunately, electricity is also the most manageable of.
Basic Electrical Safety
Copyright  Progressive Business Publications Electrical Safety.
© Recognizing Electrical Risk Factors Module 2.
Safety Rules, Practices and Devices Electric Shock – Nerve and muscle (including breathing and heart beat) functions work off of electric pluses (electron.
ELECTRICAL SAFETY OUTLINE  The basic effect of electricity on human body  Ventricular Fibrillation  Electric shock  Electric Shock – Treatment  Important.
Electrical Safety and Electrical Safe Work Practices EHS Course #525 Reference EHS Electrical Safety Procedure
Electrical Hazards Temporary Wiring and Lighting Systems.
First Draft Language (B) Service Equipment. In addition to the requirements in (A), service equipment shall contain the following information: (1)
Interface Design of Accident Analysis Programe example.
ELECTRICAL SAFETY FOR INSTRUMENTS SECTION. Electrical measurement safety Understanding hidden hazards and new safety standards.
Electrical Safety in the Workplace FN000385/CR. FN000385/CR, Electrical Safety in the Workplace 2 Overview NFPA 70E Objectives Electrical Hazards Mitigation.
A SEMINAR ON 400 KV GSS(RRVPNL) BIKANER.
Electrical Safety, Subpart K
Electrical Safety in the Workplace FN000385/CR. FN000385/CR, Electrical Safety in the Workplace 2 Overview NFPA 70E Objectives Electrical Hazards Mitigation.
All About Workplace Electrical Safety
ELECTRICAL SAFETY. OSHA Office of Training & Education Electrical Safety.
What is an arc flash5 min. Video arc flash5 min. What causes an arc flash10 min. Video PPE15 min. PPE demo10 min Flash hazard15 min. ***Flash hazard analysis.
CHEM 421 Safety Presentation. Hazard Symbols You Must Know.
1 FOM 4.2 Remediating Arc Flash Hazards in New and Existing Data Centers Joseph Furmanski Director, Data Center Facilities and Technologies.
Electrical Safety.
Electrical Safety and Safe Work Practices
Electrical Safety.
GROUND-FAULT GROUND-CHECK MONITOR
Electrical Safety Review Compliance Assistance Region IV
ANNUAL REFRESHER – electrical hazards SURFACE 2015
Murray State University
FIGURE 31-1 Internal construction of an oil-cooled ignition coil
Protection against over voltages
Electrical Safety Awareness Training
Arc Flash Fundamentals & Compliance
Click to start.
Electrical Hazards By Kory Hildebrand.
Presentation transcript:

1 LITTELFUSE STARTCO Littelfuse Startco Arc Flash Relay PGR-8800

2 LITTELFUSE STARTCO Arc Faults: Costly and Dangerous Dangers  Fires  Burns  Injury  Death Costs  Collateral damage  Equipment replacement  Downtime  Labour

3 LITTELFUSE STARTCO Arc Flash / Blast Statistics  Over 1000 people die each year from electrical accidents*  Up to 10 Arc-Flash incidents occur each day in the US  Over 2000 workers are sent to burn centers each year with severe Arc-Flash burns.  OSHA states that 80% of electrically related accidents and fatalities among Qualified Workers are caused by Arc- Flash/Arc-Blast Incidents. * Source: National Safety Council

4 LITTELFUSE STARTCO Case Study – Nov 12, 2009  Chiller Easton Ice Rink, Columbus, Ohio  An electrician was working on a 480V power panel when the panel sparked and caught fire –The electrician was thrown to the floor and eventually transported to the OSU Burn Center with severe burns on face and hands. –Witnesses reported the panel was still sparking when the fire crews arrived. * Source: Dayton Daily News

5 LITTELFUSE STARTCO  Electric Shock - trauma caused by the passage of electric current through the body.  Arc-Flash – an unexpected sudden release of intense heat and light energy produced by electricity traveling through air, usually caused by accidental contact between live conductors.  Arc-Blast - a pressure wave created by heating, melting, vaporization, and expansion of conducting material and surrounding air during an Arc-Flash. Types of Electrical Hazards

6 LITTELFUSE STARTCO Types of Electrical Hazards Arc-Blast Gases Sound Arc-Flash Light Fire Shock Pressure Wave

7 LITTELFUSE STARTCO  Severe burns  Vision damage or blindness  Hearing loss  Broken bones or internal organ damage  Whiplash  Brain injuries  Lacerations  Fatality Photos courtesy of OSHA Effects of Electrical Hazards on Workers

8 LITTELFUSE STARTCO Costly Damage…  Equipment replacement and need for capital  Equipment repair costs  Downtime  Production Loss (scrap) …and business interruption. Image from IEEE Electrical Safety Workshop, Floyd, Doan, Barrios, Wellman Image from IEEE Electrical Safety Workshop, H. Landis Floyd, II Effects of Electrical Hazards on Business

9 LITTELFUSE STARTCO  System Voltage  Arc Characteristics –Arc gap / Distance from arc  Fault Current –Available fault current –Arc current typically 38% of available fault current  Time –Clearing time Image from OSHA Office of Training & Education What Determines Arc-Flash Severity?

10 LITTELFUSE STARTCO Initiators of these faults  IEEE Std (Gold Book) Recommended Practice for the Design of Reliable Industrial and Commercial Power Systems

11 LITTELFUSE STARTCO Development of an Arc Fault  Voltage difference between two conductors (250V) separated by air gap, high resistance  Voltage reaches breakdown point, rapid release of energy across gap  Shortest distance from bus bar corner to bolt corner Usually phase-to-phase or phase-to-ground Energy limited only by system resistance, air gap impedance

12 LITTELFUSE STARTCO Lifespan of an Arc Fault

13 LITTELFUSE STARTCO Lifespan of an Arc Fault 50 kA bolted fault between 480 Vac and ground

14 LITTELFUSE STARTCO Effects of an Arc Fault Plenty of Hazards to Choose From

15 LITTELFUSE STARTCO Examples of Arc Faults

16 LITTELFUSE STARTCO Arc Flash Relay  PGR-8800 Series –1ms reaction time  Detects light –Point sensors (A) –Fiber optic sensor (B)  Detect over-currents –Phase CTs (3) –Any CT with 5A sec.  Link upto (4) AF Relays –Larger systems

17 LITTELFUSE STARTCO PGR-8800 Functions & Features  Six light sensors  Built-in front sensor  Adjustable light sensitivity  1000 event logging  Dual inputs for switches or PLC  Fail-safe operation  Local USB interface –No drivers or s/w req’d

18 LITTELFUSE STARTCO PGR-8800 Wiring Diagram

19 LITTELFUSE STARTCO PGA-LS10 - Point Sensors The sensor can be also be mounted to ”see through” the back of the cabinet. 120% 80% Coverage Half-Circle 100% Range is 2 to 2.5 meters 360° Point Sensor

20 LITTELFUSE STARTCO PGA-LS20 - Fiber-Optic Sensors One fiber-optic sensor can replace several point sensors  26 ft flexible fiber  360° detection angle  LED for visual feedback  Built-in circuit check  Electrically extendable  Plug-in connector

21 LITTELFUSE STARTCO Multi-Unit Installation Example

22 LITTELFUSE STARTCO PGR-8800 Applications Transformer primary 3 x 690 V Transformer secondary 3 x 22 kV Air-cooled transformers are sensitive to contaminants, affecting the resistance of the air gap between electrical connections (phases, bolted connections etc.)

23 LITTELFUSE STARTCO PGR-8800 Applications

24 LITTELFUSE STARTCO Additional Information   Datasheet  Product Manual  Brochure Arc Flash Relay Brochure PF136 Datasheet Littelfuse Startco: