Il Calorimetro Elettromagnetico di CMS Riccardo Paramatti CERN & INFN – Roma1 IFAE 2005 Catania 31/03/2005.

Slides:



Advertisements
Similar presentations
INFN Milano, Universita` degli Studi Milano Bicocca Siena IPRD May Testbeam results of the CMS electromagnetic calorimeter Alessio Ghezzi.
Advertisements

STFC RAL Graduate lectures 2007/8 R M Brown - RAL 1 An introduction to calorimeters for particle physics Bob Brown STFC/PPD.
Roma, 22/11/01CMS Software & Computing Workshop - E. Longo 1 Calibrazioni del calorimetro: esperienze (L3) e prospettive Egidio Longo.
ATLAS Tile Calorimeter Performance Henric Wilkens (CERN), on behalf of the ATLAS collaboration.
ECAL Testbeam Meeting, Rome 28 March 2007 Toyoko Orimoto Adolf Bornheim, Chris Rogan, Yong Yang California Institute of Technology Lastest Results from.
ECAL TIMING. 20/04/092 Ratios’ Method Basics Position of pulse maximum parameterized using the ratio of two consecutive samples, i.e., R = A(t)/A(t+1)
Application of Neural Networks for Energy Reconstruction J. Damgov and L. Litov University of Sofia.
Cosmic Rays Data Analysis with CMS-ECAL Mattia Fumagalli (Università di Milano Bicocca) CIAO!
B W Kennedy, CCLRC Rutherford Appleton Laboratory VPTs for the CMS experiment B W Kennedy CCLRC Rutherford Appleton Laboratory St Petersburg, 26 April.
N. Anfimov (JINR) on behalf of the ECAL0 team.  Introduction  Installation and commissioning  Calibration  Data taking  Preliminary result  Plans.
The Transverse detector is made of an array of 256 scintillating fibers coupled to Avalanche PhotoDiodes (APD). The small size of the fibers (5X5mm) results.
PPARC forum on developments in scintillator technology R M Brown - RAL 1 Scintillating Crystals for Particle Physics Outline  Performance considerations.
Intercalibration of the CMS Electromagnetic Calorimeter Using Neutral Pion Decays 1 M. Gataullin (California Institute of Technology) on behalf of the.
CMS ECAL 2006 Test Beams Effort Caltech HEP Seminar Christopher Rogan California Institute of Technology May 1, 2007.
The Design of Barrel Electromagnetic Calorimeter (BEMC) October Lu Jun-guang.
HPS – ECal Detector - TECHNICAL PARAMETERS The experimental apparatus includes two main detectors: a silicon vertex tracker (SVT) for precise momentum.
1 Alessandra Casale Università degli Studi di Genova INFN Sezione Genova FT-Cal Prototype Simulations.
PSD8 September 2008, Glasgow.P R Hobson, Brunel University 1 Avalanche Photodiodes and Vacuum Phototriodes for the Electromagnetic Calorimeter of the CMS.
ELECTROMAGNETIC CALORIMETER at CMS EVANGELOS XAXIRIS June 2005 Experimental Physics Techniques.
Rutherford Appleton Laboratory CMS ECAL Split 08/09/04 R M Brown - RAL 1 The Status of the CMS Electromagnetic Calorimeter R M Brown On behalf of the CMS.
Valery Dormenev Institute for Nuclear Problems, Minsk
Panic 05, 27 th Oct 2005Q. Ingram, PSI1 The Lead Tungstate Electromagnetic Calorimeter of CMS Q. Ingram on behalf of the CMS Electromagnetic Calorimeter.
Photodetection EDIT Internal photoelectric effect in Si Band gap (T=300K) = 1.12 eV (~1100 nm) More than 1 photoelectron can be created by light in silicon.
Napoli Doct. School 9 JULY 07 1 DRELL-YAN /Z/Z q q e,e, e+, +e+, +
The CMS Electromagnetic Calorimeter Roger Rusack The University of Minnesota On behalf of the CMS ECAL collaboration.
CMS ECAL Elba May 2006 R M Brown - RAL 1 The Status of the CMS Electromagnetic Calorimeter R M Brown On behalf of the CMS ECAL Group.
CMS ECAL performance and upgrade Anton Karneyeu (INR, Moscow) CMS Collaboration INSTR14, Novosibirsk, Russia, 27 February 2014.
Calibration of the CMS Electromagnetic Calorimeter with first LHC data
CMS ECAL Laser Monitoring System Christopher S. Rogan, California Institute of Technology, on behalf of the CMS ECAL Group High-resolution, high-granularity.
Toyoko Orimoto, Caltech 1 CMS Electromagnetic Calorimeter US CMS JTERM III 12 January 2009 Toyoko Orimoto California Institute of Technology.
The CMS Electromagnetic Calorimeter at the LHC
Coseners House Forum on LHC Startup 13th April 2007 David Futyan Imperial College 1 David Futyan Imperial College Calibration of the CMS ECAL Using Vector.
08-June-2006 / Mayda M. VelascoCALOR Chicago1 Initial Calibration for the CMS Hadronic Calorimeter Barrel Mayda M. Velasco Northwestern University.
BES-III Workshop Oct.2001,Beijing The BESIII Luminosity Monitor High Energy Physics Group Dept. of Modern Physics,USTC P.O.Box 4 Hefei,
B W Kennedy, CCLRC Rutherford Appleton Laboratory Vacuum Phototriodes for the CMS Electromagnetic Calorimeter Endcaps K.W.Bell, R.M.Brown, D.J.A.Cockerill,
The Case for the Dual Readout Calorimetry for SiD Adam Para, December 4, 2007.
PHOTON RECONSTRUCTION IN CMS APPLICATION TO H   PHOTON RECONSTRUCTION IN CMS APPLICATION TO H   Elizabeth Locci SPP/DAPNIA, Saclay, France Prague.
1 P.Rebecchi (CERN) “Monitoring of radiation damage of PbWO 4 crystals under strong Cs 137  irradiation in GIF-ECAL” “Advanced Technology and Particle.
FSC Status and Plans Pavel Semenov IHEP, Protvino on behalf of the IHEP PANDA group PANDA Russia workshop, ITEP 27 April 2010.
R.S. Orr 2009 TRIUMF Summer Institute
1 1 - To test the performance 2 - To optimise the detector 3 – To use the relevant variable Software and jet energy measurement On the importance to understand.
Georgios Daskalakis On behalf of the CMS Collaboration ECAL group CALOR 2006 – Chicago,USA June 5-9, 2006 CMS ECAL Calibration Strategy.
The CMS electromagnetic calorimeter
Search for Extra Dimensions in diphotons at CMS Duong Nguyen Brown University USLOU Meeting Fermilab, Oct , 2010.
Concept of NA62 IRC based on PWO scintillation crystals A.Fedorov, M. Korjik, A. Lobko Institute for Nuclear Problems, Minsk, Belarus A. Kourilin JINR,
Studies of Electroweak Interactions and Searches for New Physics Using Photonic Events with Missing Energy at the Large Electron-Positron Collider Marat.
Test Beam Results on the ATLAS Electromagnetic Calorimeters Lucia Di Ciaccio – LAPP Annecy (on behalf of the ATLAS LAr Group) OUTLINE Description of the.
Calibration of the CMS Electromagnetic Calorimeter with LHC collision data Maria Margherita Obertino on behalf of the CMS Collaboration Introduction The.
Régis Lefèvre (LPC Clermont-Ferrand - France)ATLAS Physics Workshop - Lund - September 2001 In situ jet energy calibration General considerations The different.
LHC Symposium 2003 Fermilab 01/05/2003 Ph. Schwemling, LPNHE-Paris for the ATLAS collaboration Electromagnetic Calorimetry and Electron/Photon performance.
Upgrade of the MEG liquid xenon calorimeter with VUV-light sensitive large area SiPMs Kei Ieki for the MEG-II collaboration 1 II.
CMS ELECTROMAGNETIC CALORIMETER Jean-Pierre Ernenwein OVERVIEW 6th international conference on advanced technology and particle physics Villa Olmo, Como,
Calibration of the CMS Electromagnetic Calorimeter with LHC collision data Maria Margherita Obertino on behalf of the CMS Collaboration Introduction The.
Study of the MPPC for the GLD Calorimeter Readout Satoru Uozumi (Shinshu University) for the GLD Calorimeter Group Kobe Introduction Performance.
3/06/06 CALOR 06Alexandre Zabi - Imperial College1 CMS ECAL Performance: Test Beam Results Alexandre Zabi on behalf of the CMS ECAL Group CMS ECAL.
G. Dissertori ETH Zürich May 1, 2003 LHCS03, CMS ECAL 1 CMS: Electromagnetic calorimetry and e/gamma performance G. Dissertori ETH Zürich LHC Symposium,
2004 LHC DAYS IN SPLIT- October 8 th 2004 L. Dobrzynski - LLR CMS - ECAL Test beam results Ludwik Dobrzynski On behalf of ECAL CMS LLR- Ecole polytechnique.
Electromangetic calorimeter of CMS: status and performances
Ilhan TAPAN* and Fatma KOCAK
The Electromagnetic Calorimetry of the PANDA Detector at FAIR
Calibration of the Electromagnetic Calorimeter of the CMS detector
Overview Detector details Crystals Photo-detectors
The Status of the CMS Electromagnetic Calorimeter
CMS ECAL Calibration and Test Beam Results
Update on TB 2007 Xtal Irradiation Studies at H4
A study on stochastic term of calorimetric energy resolution
Conceptual design and R&D Progress of STCF ECAL
Slope measurements from test-beam irradiations
ELECTROMAGNETIC CALORIMETER
CMS ECAL Cosmic Calibration
Presentation transcript:

Il Calorimetro Elettromagnetico di CMS Riccardo Paramatti CERN & INFN – Roma1 IFAE 2005 Catania 31/03/2005

Riccardo ParamattiCatania - 31/03/20052 Outline Caratteristiche del calorimetro Stato della costruzione Precalibrazione del calorimetro Strategie di calibrazione in situ Ricostruzione degli elettroni Partecipazione INFN (Roma, Milano e Torino): costruzione e test moduli del calorimetro, produzione e test schede elettronica, sistema di raffreddamento, sistema High Voltage per APD, struttura meccanica, ECAL database, precalibrazione, analisi e simulazione Test Beam, produzione Montecarlo, calibrazione in situ, analisi canali SM Higgs e BSM.

Riccardo ParamattiCatania - 31/03/20053 ECAL Homogenous calorimeter Lead Tungstate Crystals PbW0 4 Solenoidal Magnetic Field: 4 Tesla Crystal Producers: Bogoroditsk (Russia), Shanghai Institute of Ceramics (Cina) Construction Regional Centers: CERN (lab 27) and INFN/ENEA - Rome ECAL Introduction

Riccardo ParamattiCatania - 31/03/ BaF2CsI(Tl)CsICeF3BGO PWO  g/cm 3 X cm RM cm  / ns p / / nm n ( p) LY100%15%85%7%5%10%0.2%Nal NaI(Tl)BaF 2 CsI(Tl)CsICeF 3 BGO PWO Typical light yield of NaI   /MeV Crystal choice

Riccardo ParamattiCatania - 31/03/20055 Fast scintillation Small X o and R m Radiation hardness Relatively easy to grow Low Light Yield High index of refraction Strong LY dependance on T Characteristics 

Riccardo ParamattiCatania - 31/03/20056 The discovery potential of an intermediate mass Higgs boson via the two photon decay channel is strongly dependent on the energy resolution. a : stochastic term from Poisson-like fluctuations –sampling contribution (natural advantage of homogenous calorimeters) b : constant term –dangerous limitation to high energy resolution –important contribution from intercalibration constants c : noise term from electronic and pile-up –relevant at low energy Energy Resolution (1)

Riccardo ParamattiCatania - 31/03/20057 photostatistics contibution: - light yield - geometrical efficiency of the photodetector - photocatode quantum efficiency electron current multiplication in APDs lateral containment of the shower Stochastic Term Energy Resolution (2)

Riccardo ParamattiCatania - 31/03/20058 leakage (front, rear, dead material) CMS full shower simulation < 0.2 % temperature stabilization < 0.1 ˚C (dLY/dT = 18˚C ; dM/dT ~ -2.3 %/˚C) APD bias stabilization (  20 mV / 400 V) (dM/dV = 3%/V) light collection uniformity (next slide) intercalibration by light injection monitor and physics signals Total constant term C ≈ 0.5 % Energy Resolution (3) Constant Term contributions:

all polished  Ra=0.34   Ra=0.24  A non uniformity of the light collection in the shower max region may significantly contribute to the constant term in the energy resolution. Uniformity can be controlled by depolishing one lateral face with a given roughness Light Collection Uniformity Uniformity treatment

Riccardo ParamattiCatania - 31/03/ Construction (1) BARREL ingot Crystal R&D phase ( ) 6000 crystal preproduction ( ) Crystal production: Barrel Endcap PbO + W0 3 Metodo di crescita: Czochralski

Riccardo ParamattiCatania - 31/03/ CERN (lab 27) and INFN/ENEA (Casaccia) Regional Centers: Automatic measurements of: crystal dimensions, trasmission, light yield and uniformity Submodule assembly (10 crystals) Module assembly (40-50 submodules) Module type 2 - Rome Module type 4 - Cern Construction (2)

Catania - 31/03/2005 Modules from Rome RC 1 SuperModule = 4 Modules = 1700 xtals APDs + 68 TriggerTowers + 34 HV channels + … Construction (3) Up to now, more than half of the barrel modules have been assembled. Foreseen rate: one SuperModule per month (= real rate) The electronic chain is assembled and tested at Cern (Prevessin)

Riccardo ParamattiCatania - 31/03/ Crystal measurements performed in the Regional Centers allow to precalibrate the electromagnetic calorimeter to a precision level of about 4%. A useful correlation between Light Yield and Longitudinal Transmission has been observed. It helps to improve the precalibration at the startup. Precalibration (1)

Riccardo ParamattiCatania - 31/03/ Precalibration (2) Calibration with Cern-SPS electron beams in the last three years Few other SuperModules could be probably tested and calibrated in the 2006 test Cern. This year a cosmic run will start. The aim is to reach a precalibration level of 3% with a rate of two SuperModules per month. Goals: electronics: noise cooling: T stability High Voltage: V stability Laser: stability and performance in the irradiation phase Energy resolution Precalibration precision < 0.5%

15 The relation between XL response to electrons (S/S 0 ) and response to laser (R/R 0 ) varies in the same way during recovery and irradiation phases. Laser Monitoring Electromagnetic radiation produces a damage: crystal trasparency is reduced scintillation mechanism is not affected

Riccardo ParamattiCatania - 31/03/ At the beginning of detector operation -> fast intercalibration method based on the  symmetry in minimum bias events. Energetic electrons from Z  e + e - decay -> intercalibration of different regions and absolute energy scale setting. Once the Tracker fully functional -> intercalibration of individual crystals with E/p measurement (W  e events). TRACKER MATERIAL: the amount of material (~ 1 X 0 ) between interaction point and ECAL is the main difficulty in performing calibration. In-situ calibration with physics events : this is the main tool to reduce the constant term to the design goal of 0.5%. Insitu Calibration (1)

Riccardo ParamattiCatania - 31/03/ Complex tracking system + frames + cooling + cables and services Around one radiation lenght between the interaction point and the electromagnetic calorimeter ! Bremsstrahlung and photon conversion (big non-gaussian tails in physical distributions) Tracker Material E25/E_True: Mean and Gaussian Peak η = 0 barrel η = 1.5

Riccardo ParamattiCatania - 31/03/ e  The electron cluster is spread by Bremsstrahlung (mainly in  ) Too little recostructed cluster: not full containment of brem. photons Too big recostructed cluster: noise, pile-up SuperCluster = clustering with dynamic algos. Electron Reconstruction more brem./conversions = bigger SC dimension SC Energy and Position are used in High Level Trigger

Riccardo ParamattiCatania - 31/03/ single electrons, p t > 28 GeV only single clusters super-clusters To be compared with intrinsic calorimeter resolution < 0.9% Electronic noise No Pile-Up Electronic noise No Pile-Up Electron Reconstruction (2) This dynamic algorithm reduces non gaussian tails more than a fixed dimension algorithm (e.g. nxn crystals cluster). SuperCluster is optimized for HLT threshold energies. Considering low energy electron (≈ 10 GeV), tracker momentum helps to improve energy measurements. Work in progress.

Riccardo ParamattiCatania - 31/03/ Aim: reduce the number of intercalibration constants at the startup: from (crystals) to 170 (rings) in the barrel. Assumption: the total transverse energy deposited from a large number of events should be the same for all crystals at fixed   symmetry Studies with fully simulated Montecarlo give a precision of 1.3% - 3.5%, in case of limited knowledge of  inhomogeneity. Insitu Calibration (2)

Riccardo ParamattiCatania - 31/03/ Z  e + e - The rings can rapidly be intercalibrated using Z  e + e - without tracker momentum measurements, using reconstruction of the invariant mass A large fraction of events allows to intercalibrate the endcaps with respect to the barrel The Z  e + e - rate is ~ 1 Hz (almost flat in  ) The electron shower involves many crystals -> algorithm to unscramble individually the calibration constants. The W  e rate is ~ 10 Hz. In a couple of months at 2*10 33 cm -2 s -1, exploiting the full tracker information will allow to reach 0.5% resolution. W  e New calibration studies on low energy photons (π →  and η →  ). Mainly during the startup phase. Insitu Calibration (3)

Riccardo ParamattiCatania - 31/03/ Conclusioni Stiamo lavorando per…

Riccardo ParamattiCatania - 31/03/200523

Avalanche Photo Diodes 6m6m 2 APDs per crystal: 50 mm 2 active area Internal gain: HV ≈ 380 V Good match to PWO scintillation spectrum (Q.E. ≈ 430 nm) Strong sensitivity of gain to Voltage and Temperature variations: good stability needed Due to low light yield, need photodetector with intrinsic gain. Radiation hard and insensitive to magnetic field (4T)

Riccardo ParamattiCatania - 31/03/ High Level Trigger

Energy-weighted mean position of crystals in the cluster with 2 corrections: –Longitudinal center of gravity of the shower because the crystals do not exactly point to the nominal interaction vertex. –Weighted mean using the logarithm in the cluster (not in the SuperCluster !) Angular Resolution