Test for the CLAS12 RICH detector L. Barion, M. Contalbrigo, L. Pappalardo (INFN Ferrara) V. Lucherini, M. Mirazita, P. Rossi (INFN Frascati) M. Turisini.

Slides:



Advertisements
Similar presentations
1Beam Line Review. 17th November Detector parameters Fermilab Beam line monitors built to replaced SWICS Scintillating fibre tracker – readout.
Advertisements

Performance of MPPC using laser system Photon sensor KEK Niigata university, ILC calorimeter group Sayaka IBA, Hiroaki ONO, Paul.
Study of Photon Sensors using the Laser System 05/7/12 Niigata University, Japan Sayaka Iba, Editha P. Jacosalem, Hiroaki Ono, Noriko.
1 Scintillating Fibre Cosmic Ray Test Results Malcolm Ellis Imperial College London Monday 29 th March 2004.
Tagger Electronics Part 1: tagger focal plane microscope Part 2: tagger fixed array Part 3: trigger and digitization Richard Jones, University of Connecticut.
1 KEK Beam Test Analysis Hideyuki Sakamoto 15 th MICE Collaboration Meeting 10 st June,2006.
Y. Karadzhov MICE Video Conference Thu April 9 Slide 1 Absolute Time Calibration Method General description of the TOF DAQ setup For the TOF Data Acquisition.
FMS review, Sep FPD/FMS: calibrations and offline reconstruction Measurements of inclusive  0 production Reconstruction algorithm - clustering.
Measurement of the absolute efficiency,
The PEPPo e - & e + polarization measurements E. Fanchini On behalf of the PEPPo collaboration POSIPOL 2012 Zeuthen 4-6 September E. Fanchini -Posipol.
Leroy Nicolas, HESS Calibration results, 28 th ICRC Tsukuba Japan, August Calibration results of the first two H·E·S·S· telescopes Nicolas Leroy.
Abstract A time resolved radial profile neutron diagnostic is being designed for the National Spherical Torus Experiment (NSTX). The design goal is to.
A Reconstruction Algorithm for a RICH detector for CLAS12 Ahmed El Alaoui RICH Workchop, Jefferson Lab, newport News, VA November th 2011.
New Developments in Large Area THGEMs & APV Exercise INFN – Sezione di Trieste Carlos Alexandre Fernandes dos Santos 11/December/2014.
14/02/2007 Paolo Walter Cattaneo 1 1.Trigger analysis 2.Muon rate 3.Q distribution 4.Baseline 5.Pulse shape 6.Z measurement 7.Att measurement OUTLINE.
Experimental set-up Abstract Modeling of processes in the MCP PMT Timing and Cross-Talk Properties of BURLE Multi-Channel MCP PMTs S.Korpar a,b, R.Dolenec.
Updates on GEMs characterization with APV electronics K. Gnanvo, N. Liyanage, K. Saenboonruang.
VC Feb 2010Slide 1 EMR Construction Status o General Design o Electronics o Cosmics test Jean-Sebastien Graulich, Geneva.
The Scintillator ECAL Beam Test at FNAL K. Kotera, Shinshu-u, 1st October 2009 CALICE Scintillator ECAL group; Kobe University, Kyungpook University, the.
Experimental set-up for on the bench tests Abstract Modeling of processes in the MCP PMT Timing and Cross-Talk Properties of BURLE/Photonis Multi-Channel.
work for PID in Novosibirsk E.A.Kravchenko Budker INP, Novosibirsk.
Simonetta Gentile, LCWS10, March 2010, Beijing,China. G-APD Photon detection efficiency Simonetta Gentile 1 F.Meddi 1 E.Kuznetsova 2 [1]Università.
PrimEx collaboration meeting Energy calibration of the Hall B bremsstrahlung tagging system using magnetic pair spectrometer S. Stepanyan (JLAB)
July 4, 2008 SuperBelle Meeting, KEKPeter Križan, Ljubljana Peter Križan University of Ljubljana and J. Stefan Institute Burle MCP PMTs as photon detector.
The RICH prototype V. Lucherini, M. Mirazita, S. Pereira, D. Orecchini, A. Orlandi, A. Viticchie’ - INFN Frascati L. Barion, M. Contalbrigo, R. Malaguti,
DEAR SDD --> SIDDHARTA
Status of photon sensor study at Niigata University -- SiPM and MPPC -- Photon sensor mini workshop 05/9/16 University Niigata University.
Test beam preliminary results D. Di Filippo, P. Massarotti, T. Spadaro.
E.Guschin (INR,Moscow) 3 May 2006Calorimeter commissioning meeting Status of PRS/SPD detector Cosmic test results Installation/tuning of monitoring system.
The RICH Detectors of the LHCb Experiment Carmelo D’Ambrosio (CERN) on behalf of the LHCb RICH Collaboration LHCb RICH1 and RICH2 The photon detector:
CALICE Tungsten HCAL Prototype status Erika Garutti Wolfgang Klempt Erik van der Kraaij CERN LCD International Workshop on Linear Colliders 2010, October.
1 Calorimeters LED control LHCb CALO meeting Anatoli Konoplyannikov /ITEP/ Status of the calorimeters LV power supply and ECS control Status of.
Slide 1Turisini M. Frontend Electronics M.Turisini, E. Cisbani, P. Musico CLAS12 RICH Technical Review, 2013 June Requirements 2.Description of.
5-9 June 2006Erika Garutti - CALOR CALICE scintillator HCAL commissioning experience and test beam program Erika Garutti On behalf of the CALICE.
RICH detector for CLAS12 CLAS12 Technical Workshop P. Rossi Laboratori Nazionali di Frascati - INFN.
RICH simulation for CLAS12 Contalbrigo Marco INFN Ferrara Luciano Pappalardo INFN Ferrara Hall B Central Detector Forward Detector M. Contalbrigo1 JLAB12.
RICH simulation for CLAS12 Contalbrigo Marco INFN Ferrara Luciano Pappalardo INFN Ferrara Hall B Central Detector Forward Detector M. Contalbrigo1JLAB12.
1 First Results of the SLD Cerenkov Polarimeter at the DESY test beam Oleg Eyser Daniela K äfer, Christian Helebrant, Jenny List, Ulrich Velte*
Villa Olmo, Como October 2001F.Giordano1 SiTRD R & D The Silicon-TRD: Beam Test Results M.Brigida a, C.Favuzzi a, P.Fusco a, F.Gargano a, N.Giglietto.
PROPOSAL FOR A MUON VETO SYSTEM BEHIND THE HADRONIC CALORIMETER (MUV-3) Problems and requirements:  Expected total rate for 9.25 < R < 120 cm: 12.1 MHz:
CALICE, CERN June 29, 2004J. Zálešák, APDs for tileHCAL1 APDs for tileHCAL MiniCal studies with APDs in e-test beam J. Zálešák, Prague with different preamplifiers.
DHCAL Jan Blaha R&D is in framework of the CALICE collaboration CLIC08 Workshop CERN, 14 – 17 October 2008.
A. SarratILC TPC meeting, DESY, 15/02/06 Simulation Of a TPC For T2K Near Detector Using Geant 4 Antony Sarrat CEA Saclay, Dapnia.
Testbeam analysis Lesya Shchutska. 2 beam telescope ECAL trigger  Prototype: short bars (3×7.35×114 mm 3 ), W absorber, 21 layer, 18 X 0  Readout: Signal.
HCAL1 Status 2004 Oleg Gavrishchuk, JINR, Dubna 1. HCAL1 performance in 2004 General design High Voltage system LED monitoring 2. Stability in 2003 Led.
Photon Transport Monte Carlo September 27, 2004 Matthew Jones/Riei IshizikiPurdue University Overview Physical processes PMT and electronics response Some.
RICH studies for CLAS12 L. Pappalardo1 Contalbrigo Marco Luciano Pappalardo INFN Ferrara CLAS12 RICH Meeting – JLab 21/6/2011.
Status of NEWCHOD E.Guschin (INR), S.Kholodenko (IHEP), Yu.Kudenko (INR), I.Mannelli (Pisa), O.Mineev (INR), V.Obraztsov (IHEP), V.Semenov(IHEP), V.Sugonyaev.
Prototypes photon veto detectors for NA62 experiment CERN M. Raggi - INFN/Frascati for the NA62 Photon Veto Working Group LNF, RM1, NA, PI, SOFIA First.
M.Taguchi and T.Nobuhara(Kyoto) HPK MPPC(Multi Pixel Photon Counter) status T2K280m meeting.
3/06/06 CALOR 06Alexandre Zabi - Imperial College1 CMS ECAL Performance: Test Beam Results Alexandre Zabi on behalf of the CMS ECAL Group CMS ECAL.
Tracker Neutron Detector: INFN plans CLAS12 Central Detector Meeting - Saclay 2-3 December 2009 Patrizia Rossi for the INFN groups: Genova, Laboratori.
Simulation and reconstruction of CLAS12 Electromagnetic Calorimeter in GSIM12 S. Stepanyan (JLAB), N. Dashyan (YerPhI) CLAS12 Detector workshop, February.
1 SuperB-PID, LNF 4/4/2011 MAPMTsSilvia DALLA TORRE COMPASS experience with HAMAMATSU MAPMTs S. Dalla Torre.
Analysis of LumiCal data from the 2010 testbeam
PreShower Characterisations
Fabio, Francesco, Francesco and Nicola INFN and University Bari
The MiniBooNE Little Muon Counter Detector
CLAS12 – RICH RICH - TECHNICAL PARAMETERS PARAMETER DESIGN VALUE
Panagiotis Kokkas Univ. of Ioannina
Detection of muons at 150 GeV/c with a CMS Preshower Prototype
Conceptual design of TOF and beam test results
Instrumentation for Colliding Beam Physics 2017
RICH simulation for CLAS12
Upgrade magnets and power supplies
p0 life time analysis: general method, updates and preliminary result
Multianode Photo Multipliers for Ring Imaging Cherenkov Detectors
Department of Physics and Astronomy,
Upgrade magnets and power supplies
Performance test of a RICH with time-of-flight information
Presentation transcript:

Test for the CLAS12 RICH detector L. Barion, M. Contalbrigo, L. Pappalardo (INFN Ferrara) V. Lucherini, M. Mirazita, P. Rossi (INFN Frascati) M. Turisini (INFN Sanita’) Aldo Orlandi, Angelo Viticchie’ (INFN Frascati) for the preparation of the test set-ups CLAS Collaboration meeting, October 12-15, 2011 Marco Mirazita

Goals of the tests 1.Test MAPMT as single photon detectors  H8500C (normal glass) and H8500C-03 (UV glass) vs R Validate Monte Carlo simulations with a small scale RICH prototype - Laboratory set-up using laser blue light - Hadron (pion) beam test of RICH prototype

MAPMT characterization as single photon detectors 1) Single photon response - distance between peak and pedestal - peak width - threshold cut 2) Few photon response - distance between peaks - width of the peaks 3) Behaviour with HV - lowest HV for a given 1pe efficiency (80%? 90%?) 4) Uniformity of the PMT response - comparison between border and central pixels 5) Cross talk between pixels 6) Comparison between PMTs LASER BEAM LASER BEAM

Laser tests

Test laser setup LASER PC trigger IN trigger OUT fiber collimator filters MAPTM anode OUT 0 63 QDC gate black box Laser intensity can be adjusted via the remote control and using neutral density filters The fiber head can be remotely moved in (x,y) to scan the PMT surface Conventional electronics for data acquisition (CAEN V792) DAQ rate fixed at 100 Hz

short flat cables laser controller motor controller electronics

fiber head + collimator + filters MAPMT – H8500C

anode connections dynode output ground connections

Noise measurement HV=-1125V on but PMT covered by its cap QDC 0 QDC 15 PMT H8500C

Analysis of ADC spectra Poisson weights for 0,1,2,... p.e. pedestal  = average number of p.e. N = max number of p.e. photoelectron peaks Several shapes tried, gaussians provide better results in terms of convergence of the fits and uniformity of the parameters

ADC spectrum HV = 1000 V pixel 25 (border) pixel 36 (centre) Fits with up to 5 p.e. peaks

PMT response normalization constantaverage number of p.e. 1. p.e gain (QDC channels) fraction of 1 p.e. loss PMT H8500C HV = 1000 V

Results for 10 MAPMTs HV = 1000 V points: mean of 64 pins error bar: RMS of the 64 pins gain from data sheets (a.u.)

ADC spectrum vs HV HV = 1000 V HV = 1040 V HV = 1075 V pixel 25 (border) pixel 36 (center) better pedestal/signal separation easier threshold setting

HV scan Up to a factor 2 increase in the gain More than 85% detection efficiency for HV>1040 V Recommended working range HV= V

Measurement in magnetic field Compensating sextupolar magnet No field at the center Up  50 gauss going toward the border Perpendicular to the electron motion in the MAPMT HV=1040 V larger field smaller field

Magnetic field test Less than 15% gain loss Small decrease in detection efficiency No major degrading in the MAPMT response HV = 1040 V B=0 B>0 B=0 B>0

Cross-talk analysis Compare the pixel response when - it is directly illuminated by the laser - adjacent pixels are illuminated Threshold: 3  above pedestal

Cross-talk contamination N = events above threshold i = up,down,left,right = 2.1% = 2.0% = 2.1% = 2.6% For a given pixel:

Hadron beam test CERN, july 7-20, 2011

T9

The T9 hadron beam Magnet polarity set for negative particles 400 ms 40 s Time structure of the beam: 3 short pulses every 40 s duty cycle ~3% Transverse dimensions: few cm at the entrance window of the hall focused after ~7.5m (close to our setup) Hadron intensity particles per pulse N(  ) ~ 60 N(K)

The Experimental Hall Beam CLAS12 RICH GSI Glasgow

The Setup Beam Backward Scintillator 2x3 cm2 Two Forward Scintillators ~1x1 cm2 coinc. aerogel PMT Trigger of the DAQ: T beam *SC back *SC forwH *SC forwV Two Reference Scintillators ~2x3 cm2 black box 60 cm

The RICH prototype

The PMT array 10 H85008 R8900 H8500-C H8500-C-03 H8500-C H8500-C-03 H8500-C H8500-C-03 H8500-C H8500-C-03 H8500-C H8500-C-03

The acquisition electronics Maroc2 front end electronics 1 control board with 2 back planes up to 8 front end cards per back plane 64 channels per card, 4096 total channels preamplifier, adjustable from 1/8 to 4 ADC, about 80fC per channel control board back planes MAROC front end cards Visual C++ program to read the electronics (windows) Event transfer to disk in single or multi event mode

Preliminary test of the DAQ 2 reference scintillators for counting normalization trigger rate measured with a scaler event rate measured with DAQ system DAQ eff. = event rate / trigger rate 1. scan of trigger rate by moving the box in or out of the beam 2. take into account ~3% beam duty cycle black: single event buffering red: multi-event buffering DAQ efficiency DAQ rate before (empty symbols) and after (full symbols) duty-cycle correction DAQ rate DAQ rate in one spill ~200Hz

Run conditions Most of the 2 weeks of data taking to deal with the electronics - timing between MAPMT signals and trigger - find stable conditions of low voltage supply - optimization of preamp gain No stable conditions were found with 12 MAPMT only 1 back plane was used 8 MAPMT H8500 (HV=1075 V) few preliminary data with R8900 (HV=970 V) preamp gain = 4 E beam (GeV) Aerogel (cm) cm N. of triggers t (cm)n k 102= k 103= k 103= k k

ADC distributions R8900 gain = 0.5 PRELIMINARY RUN

ADC distributions H8500 gain = 0.5 PRELIMINARY RUN

ADC distributions H8500 gain = 4 FINAL CONDITIONS

ADC distributions threshold to remove pedestal 2.5% of the pedestal height = 0.05 Fit of the distribution additional exponential background

Hit distributions aerogel n=1.05 aerogel n=1.03 1cm2cm 1cm 3cm integrated distributions of hits above threshold

Cerenkov ring calculation Minimization of: Free parameters are the center coordinates (X C,Y C ) and the radius R The problem can be solved analitically Procedure : 1.Calculate center and radius with all hits above threshold 2.If the distance of a hit from the ring is bigger than 2 pixels (12mm) it is removed and a new calculation is done 3.The iteration is stopped if no more hits have to be removed or if N hits <3

Some ring GOOD EVENT

Some ring BAD EVENT

Some ring blue: first iteration red: last iteration Background hit Cross-talk hit? Analysis of cross-talk hits: when 2 or more hits in adjacent pixels, keep only the one with highest QDC readout

Aerogel with n=1.05: ring reconstruction 1 cm 2 cm 3 cm red: good hits black: hits for the fitted ring (at least 3) blue: cross talk hits hits per event rescaled to full circle fraction of event with a ring Number of hits per event

Aerogel with n=1.05: radius mean sigma Expected radius for pions ~110mm  measured ~120mm  increasing with t Larger radius, better resolution for larger t  expected opposite 1 cm 2 cm 3 cm

Radius resolution estimation  n free parameter, everything else known from geometry Cerenkov angle resolution  beam  3 mm

H8500 – entrance window H8500-C (normal glass) H8500-C-03 (UV glass) With UV glass about 0.5 hits more ~+20% Smaller differences for increasing threshold Number of hits per ring t=2 cm

Fitted Radius: H8500 types Fitting rings with 4 PMT of the same type H8500C normal glass H8500C-03 UV glass =119.0±0.1 mm  =4.48±0.03 mm =118.4±0.1 mm  =4.48±0.02 mm t=2 cm

Runs with mirrors PRELIMINARY ANALYSIS 4 x R8900 MAPMT E = 1.5 GeV

Radius reconstruction no mirrors  =4.48±0.03 mm  =7.9±0.3 mm = 4.9 on half ring ~ 10 on full ring Xtalk ~ 3-4 hits No cross talk hit analysis PRELIMINARY ANALYSIS

Conclusions and outlook Laser tests of MAPMTs has been (are being) performed in Frascati measurements at 1000 V in agreement with data sheets, but too low HV for reliable single photon detection increasing HV (>~1040 V) sufficiently good single photon detection efficiency can be obtained no large effect from small magnetic field (preliminary) We had successful test at CERN we saw pion Cerenkov rings close to what we expected there things that need to be analyzed more in detail electronics is a crucial point  H8500 could be good single photon detectors

Next RICH prototype Larger gap lenght ~ 1 m About 20 MAPMT to accomodate in the prototype Radial geometry CLAS sector geometry

backup slides

Pedestal measurements: stability RMS (QDC channels) Run number QDC 0 QDC Very low noise, high stability over a week of measurements PMT H8500C

ADC fitting functions GAUSS SKEWED GAUSS peak distance

Radius resolution Larger thickness means: - larger uncertainty on the emission point  R/R = t/d  3  9 % -larger number of hits ~5.5 t=1 cm ~8.7t=3 cm  /  -30 % - more surfaces to cross ? - other effects? t=2 cm black: N  5 red: N<5 sigma(R) No effect on the radius means

Aerogel with n=1.05: ring center mean (X) mean (Y) XY coordinates of the center t=2 cm sigma (X) sigma (Y)

1 cm E=4 GeV Aerogel with n= cm E=4 GeV radius 3 cm E=10 GeV XY coordinates of the center 3 cm E=10 GeV Two rings for pions and kaons?

Aerogel with n=1.03 More BKG hits in lower PMTs Applying fiducial cuts E=4 GeVT=1 cm

H8500 – border/center PMT Number of hits per ring Number of pixels:N(center) = 40 N(border) = 24 R=1.7 Number of hits:R>2 t=2 cm