This presentation exemplifies the latest Power Point dogma. 1 A full sentence at the top tells the main point. Vertically aligned lists are avoided in.

Slides:



Advertisements
Similar presentations
They were young when GPC was.. Small Subset of GPC Spare Parts To say nothing of unions, adapters, ferrules, tubing (low pressure and high pressure),
Advertisements

Lecture 17. Light Scattering/Viscometry. What is light scattering? In the lab…
Foundation GPC Part 4 – Organic Gel Permeation Chromatography Columns and Applications.
Size Exclusion Chromatography
Foundation GPC Training Course Theory. Nomenclature Gel Permeation ChromatographyGPC Size Exclusion ChromatographySEC Gel Filtration ChromatographyGFC.
1 HPLC Lecture Mobile Phase Selection in Partition Chromatography Optimization of the mobile phase composition and polarity is vital for obtaining.
Separation of molecules and determination of there molecular weight by gel filtration chromatography. Experiment 7 BCH 333.
The use of light scattering in characterizing lignin.
Advanced GPC Part 1 – GPC and Viscometry
Foundation GPC Part 5 – Polar and Aqueous Gel Permeation Chromatography Columns and Applications.
Advanced GPC Part 2 – GPC and Light Scattering
1 Probability and randomness Photon is 3-D spread out little chunk of EM wave. Gazillions of electrons in metal: Which one will be kicked out? What if.
Physical Methods to Characterize Proteins. Molecular weight Physical properties of key interest Oligomerization state Structure Interactors.
Protein Purification and Analysis Solubility of proteins important for purification: 60-80% soluble, 20-40% membrane Size of proteins varies Some proteins.
Gel Filtration Chromatography.
1 L U N D U N I V E R S I T Y Methods to determine particle properties Chapter 7.
Unit 2, Part 3: Characterizing Nanostructure Size Dr. Brian Grady-Lecturer
There are many times in nature when a solvent will pass spontaneously through a semipermeable membrane, which is a membrane permeable to solvent, but not.
AUSTEN K. SCRUGGS CALIFORNIA STATE UNIVERSITY, FRESNO RIMI FACILITY INSTRUMENTATION.
CHAPTER 29 Supercritical Fluid Chromatography The mobile phase is a supercritical fluid (a fluid above its critical T and critical pressure) Supercritical.
Multi-detector GPC Characterization Drew Poche’ Outline Basics-On the mechanism of GPC Detection –Light Scattering –Viscometry Putting it together- multi-detector.
BETTER THAN SEC’s Paul S. Russo Louisiana State University Texas Polymer Center Freeport, TX October 31, 2001.
An Extended Range of Columns for Aqueous Size Exclusion Chromatography Greg Saunders, Graham Cleaver and Ben MacCreath, Varian, Inc., Church Stretton,
Chemistry 4010 Lab It’s all about PROTEINS… It’s all about PROTEINS…
Gel filtration chromatography y/college/voet/ /animat ed_figures/ch05/f5-6.html.
Drs. Wei Tian & Yanhui Chen Sep-Dec Main Content Chromatography Analysis Gas Chromatography (GC) High Performance Liquid Chromatography (HPLC)
ADVANCED BIO-FRIENDLY POLYMERS Igor Lacík Gel permeation chromatography – a tool for determination of molar mass of polymers.
Quantitative Chemical Analysis Seventh Edition Quantitative Chemical Analysis Seventh Edition Chapter 0 The Analytical Process Copyright © 2007 by W. H.
Protein Purification and Analysis Solubility of proteins important for purification: 60-80% soluble, 20-40% membrane Size of proteins varies Some proteins.
1 High Performance Liquid Chromatography (HPLC) Lecture 40.
Bringing Biotech Product to Market Chapter 9. Objectives Purifying product Define chromatography and distinguish between planar and Column chromatography.
GC Advantages 1. Very Large N (Very Long Columns) 2. No Packing Material (A=0) 3. Simple Mobile Phase (Compressed Gas) 4. Universal Detectors (FID) 5.
Factors affecting electrophoresis The electric field ·       Voltage. If the separation of the electrodes is d (cm) and the potential difference.
History of Chromatography n Early LC carried out in glass columns n diameters: 1-5 cm n lengths: cm n Size of solid stationary phase n diameters:
Part III: Polymer Characterization - Chapter 6: Characterization of Molecular Weight - Chapter 7: Polymer Solubility and Solution - Chapter 8: Phase Transition.
Ch 24 pages Lecture 10 – Ultracentrifugation/Sedimentation.
Page 1 What happened here? Read the following story and see if you can figure it out Imagine you are a pilot from USA getting ready for your return flight.
Chemistry 367L/392N Macromolecular Chemistry Lecture 8.
Proteins separation and analysis using Fast Protein Liquid Chromatography Ayelet David, Ph.D Dept. of Clinical Pharmacology.
Ch 24 pages Lecture 11 – Equilibrium centrifugation.
Chromatography High Performance Liquid Chromatography HPLC Chapter Dr Gihan Gawish.
HPLC.
Chapter 28 High Performance Liquid Chromatography.
Ch 21 – Principles of Chromatography and Mass Spectrometry Ch 22 – Gas and Liquid Chromatography.
1 High Performance Liquid Chromatography (HPLC) Lecture 40.
Membrane Osmometry Alfredo Clemente CH 392N Prof. Grant Willson. The University of Texas Austin.
Recent Developments in Polymer Characterization And how we may have to modify them for nanoparticles.
T.A Nouf Alshareef KAU-Faculty of Science- Biochemistry department Analytical biochemistry lab (Bioc 343) 2012 False colour scanning.
Lecture 8 Peak Parameters and Quantitative chromatography
BY G.SHRAVANI ION EXCHANGE AND GEL PERMEATI ON CHROMATOGRAPHY 1G.SHRAVANI.
Principles of chromatography
Chromatography.
SIZE EXCLUSION CHROMATOGRAPHY
PREPARED BY VAISHNANI BHAVIN M.PHARMA-I (Q.A.). Qualitative error sources in HPLC: Poor separation power. Some special substances from the samples can.
 Laboratory technique for the Separation of mixtures  Chroma -"color" and graphein - "to write”.  Colour bands - separation of individual compounds.
Chemistry 367L/392N Macromolecular Chemistry Lecture 10.
Bioseparation II Chromatography Techniques. Chromatography Most widely used purification technique used for biomolecules. Most widely used purification.
High Performance Liquid Chromatography Presented by Dr. Kamal Modi 2 nd Year Resident.
Gel Permeation Chromatography Size Exclusion Chromatography
A guide for A level students KNOCKHARDY PUBLISHING
Gel Filtration Chromatography.
Size Exclusion Chromatography (SEC)
Biophysical Tools '04 - Chromatography
Techniques of protein purification
Dnyanasadhana College, Thane.
Gel Filtration Chromatography.
BASICS OF SUPERCRITICAL FLUID CHROMATOGRAPHY
Polymer Characterization
M.S COLLEGE OF ARTS, SCIENCE, COMMERCE AND B.M.S
A guide for A level students KNOCKHARDY PUBLISHING
Presentation transcript:

This presentation exemplifies the latest Power Point dogma. 1 A full sentence at the top tells the main point. Vertically aligned lists are avoided in favor of diagonal arrangement to create visual tension. A page number helps reader ask questions. Tasteful use of animation helps. Occasionally, put in something strange or fun to keep professors and other tired listeners awake. dogma, n. A settled or established opinion, belief, or principle

“You cannot measure absolute molecular weights” Dow manager, 1983 Wrong! Correct, even in 1983: you NEED NOT always measure ABSOLUTE molecular weights…but you could have. Correct in 2005: it is almost always essential to measure absolute M s. 2

So, how would you analyze polymers and nanoparticles for polydispersity?

Here is the easiest equation in this talk. SEC = GPC = GFC Size Exclusion Chromatography Gel Permeation Chromatography Gel Filtration Chromatography 4

A riddle: After a hurricane, many trees fall over and bend into a river. Also, a cow and a dog fall into that flooded river. Which one reaches the ocean first, cow or dog? Moo! Woof! 5

In GPC, as when throwing a cat through a tree, the big things come out first.. Solvent flow carries molecules from left to right; big ones come out first while small ones get caught in the pores. It is thought that particle volume controls the order of elution. But what about shape ? 6

Simple SEC is only simple when you don’t have to do it yourself. degas pump injector DRI VeVe log 10 M c c c 7

In simple GPC, you first make a map (calibrate), then follow it. VeVe log M VoVo VeVe A DRI VeAVeA DRI A MAMA 8

Are you straight? 9

Use the right tool (column) for the job. 10

OK, but how did you get the M values for the standards? Osmometry Scattering MALDI Analytical ultracentrifugation End group analysis Goal in this class: make it seem reasonable that it IS possible to measure M values. 11

Osmometry is Real Science because it is tied closely to thermodynamics. Semipermeable membrane: stops polymers, passes solvent. h  V = n R T n = g/M c = g/V  = c R T 12

Light scattering operates on thermodynamics; think of it as an osmometer without the membrane. 100,000  x c  Teaching Light Scattering to Exemplify and Reinforce Basic Principles, D. S. Poche', P. S. Russo, B. Fong, E. Temyanko and H. Ricks, J. Chem. Ed., 1999, 76 (November),

LS adds optical effects  Size. q = 0 in phase I s maximum q > 0 out of phase, I s goes down 14

Just add LS detector…and much complexity. degas pump injector DRI MALLS 15

This waterfall plot shows many “slices” of a chroma- togram: 13 angles were recorded ~8 times per second as the sample flowed by the MALS detector. Scattering angle VeVe Scattered intensity 16

The scattering “envelope” for a single slice shows how I s decreases with angle. Intercept  Molecular weight Slope  Size 17

We add a viscometer in some cases. degas pump injector DRI LS90 o  P   viscometer 18

Intrinsic viscosity is a secondary molecular weight method so good it’s almost like the real thing. Mark-Houwink-Sakurada relationship between the intrinsic viscosity and the molecular weight. K and a are constants for a given polymer, not strongly dependent on solvent or temperature, as long as we’re talking about a “good solvent”. These words have special meaning in polymer science. 19

Grubisic, Rempp & Benoit, JPS Pt. B, 5, 753 (1967) One of of the most important papers in polymer science. Imagine the work involved! 6 pages long w/ 2 figures. Selected for JPS 50 th Anniv. Issue. Universal Calibration lets you get the molecular weight of one kind of polymer knowing only the Mark-Houwink- Sakurada values of a standard (look it up) and your unknown (uh-oh). 20

Universal Calibration says that whatever comes out at a particular volume has the same product, [  ]M. [  ] = KM a [  ] A  M A = [  ] S  M S = f (V e ) Mark-Houwink Relation Universal Calibration A = analyte; S = standard Combine to get these two equations, useful only if universal calibration works! 21

They were young when GPC was.

They were young when GPC hit middle age.

Here is a small subset of GPC spare parts. To say nothing of unions, adapters, ferrules, tubing (low pressure and high pressure), filters and their internal parts, frits, degassers, injector spare parts, solvent inlet manifold parts, columns, pre-columns, pressure transducers, sapphire plunger, and on it goes… 24

Other SEC Deficiencies 0.05 M salt at 10 am, 0.1 M salt at 2 pm? 45 o C at 8 am and 50 o C at noon? Non-size exclusion mechanisms: binding. Big, bulky and slow (typically 30 minutes/sample). Temperature/harsh solvents no fun. You learn nothing by calibrating. Columns are expensive, easily damaged. 25

Must we separate ‘em to size ‘em? Your local constabulary probably doesn’t think so. Atlanta, GA I-85N at Shallowford Rd. Sat. 1/27/01 4 pm 26

Matrix Fluorescence Photobleaching Recovery* is an LSU-invented method designed to compete with GPC for certain systems (aqueous commodity polymers).  Indicates targeted M. *G. J. Doucet, D. Dorman, R. Cueto, D. Neau, P. S. Russo, D. DeKee, J. Pople Macromolecules 2006, 39(26), 9446 –

Ultimate Goal: A Black Box for MWD Matrix FPR Easily Maintained Accurate Precise Simple Concept Expedient Easy System Switch Basic Info Obtained Miniaturizable Detect Large Masses Labeling Required GPC Accurate Simple Concept Miniaturizable No Labeling Required Broad Distributions Pumps Parts Press for MWD DLS Form Factor Index Matching Long Acquisition for Multiangle Experiments Precise Accurate DOSY Easy System Switch Precise Accurate Obtain Basic Info Labeling Required 28

In other words, the search continues. Two promising contenders are discussed next. MALDI-TOF: most effective when the molecules are small, biological and not very polydisperse. Can be coupled to GPC! FFF: like GPC only a flowing field replaces the stationary phase, stuff comes out backwards, and big stuff can be handled as well as small. 29

MALDI-TOF stands for Matrix-Assisted Laser Desorption Ionization Time-of-Flight Mass Spectrometry. 30

These data obtained at LSU: click the figure to analyze these results.  Guess what M w /M n is. 31

Patience is a virtue. You 4010 students will get to practice with a MALDI dataset, but …. that’s enough MALDI for now. 32

What about separating cows and elephants? Either will float around the trees. How do you separate them then? Moo! Eeee! 33

Field Flow Fractionation, that’s how! In FFF, large nanoparticles are made to flow between plates; a field is applied to separate them by size. 34

The most commonly used field is flow itself: one or both plates are porous, and a cross-flow is arranged. 35

What happens because of the cross-flow? Little nanoparticles come out first! At LSU, only one plate is porous. 1.Everyone calls it AF4 = Asymmetric Flow Field Flow Fractionation 2.How to you get a crossflow then? 36

Potential Advantages of FFF Handles a wider range of particles. May be easier for some aggressive solvents. 37

AF4 can even separate large PTFE latex particles. 38

Conclusion GPC is essential in any Nano Lab GPC may eventually get replaced. Matrix FPR FFF 39