INW Sensor Technology …Continued. What we will cover Installation Practices Installation Practices Security Security Changing Batteries Changing Batteries.

Slides:



Advertisements
Similar presentations
Instructional Presentation
Advertisements

AS1 Setup IRIS Kansas City Workshop September 19-21, 2007 John Lahr (with Kay Wyatt) and portions from Seismology Instruction with AmaSeis By Tammy K.
Filter Changing Procedures For TEOM Series 1400ab and Model 8500 FDMS (B & C Types)
Spiro Vision 3+ This slide show will advance automatically. To manually advance, click on the screen, or press enter.
Each laptop is numbered Each slot in the laptop cabinet is numbered. Be sure to pick up the laptop that has been assigned to you! Getting the Laptops.
Wireless Telemetry Made Easy Bringing Environmental Data to Your Desktop Presented by Gregg Gustafson January 2010.
Build Your Own Future RC2 Serviceability. Build Your Own Future Safety and Ground Rules Before servicing, always remove A/C power from the unit and disconnect.
Helmet Light User Instructions Rotate Tail cap counter clock wise to open battery compartment IR / IFF lever (only functional light In this mode) Two functional.
 In today’s new age technology, everything evolves at the speed of light. Now technology comes out almost on a daily basis and there for makes it hard.
INSTALLATION INSTRUCTIONS IMPORTANT: Read all instructions before performing any work. To avoid the risk of electric shock, turn off power before installing.
Components: Sansa Clip Mp3, earbuds, USB cable, Quick Start Guide.
easyEmission - 1st Steps & Overview
LogTag Training January 2015
Installation. Indoor Unit Installation Typical Installation.
Affordable Ownership: Filter cleaning example EMINTS -- Professional Development for Educators By Educators 
Unit Test Calibration Training
Copyright 2008 Kenneth M. Chipps Ph.D. How to Terminate a Corning Unicam Connector Last Update
1 Zebra 170 XiIII Plus Removing and Installing Printhead Calibrating Head Resistance Print Quality Adjustments.
Introducing INW Sensor Technology. Sensor History at INW Analog Pressure Sensors 1985 Analog pH & ISE Sensors 1995 Smart Pressure Sensors 2002 Smart pH.
Cleaning of the Optical Block, Critical Orifice, and Focusing Nozzle of the Brechtel Model 1710 Mixing CPC.
How to Take Apart a Compaq By: Erick Webster, Kyle Marshall, John Davidson, Spencer Grimes, Josh Sullivan, Nick Belfiore.
How to Perform Preventive Maintenance of the Personal Computer Properly Shut Down of the Computer Properly Shut Down of the Computer Unplug all Connection.
Reduced Vertical Separation Minimum (RVSM)
Familiarization and Operation
Clean Air Box Usage & Care CABs RAMs CO Monitors.
2008 Cadillac CTS With Original Antenna
MP530 Maintenance. General Description  The MP530 maritime computer is used in a wide range of Operator Stations (OSs) produced by Kongsberg Maritime.
Service Seminar Memory Craft Table of Contents MC10001 Top Cover Removal…………………………………………………………………..…………1 Belt Cover Removal……………………………………………………………..……………2-4.
How to Build A Computer By John A. Saiz. Materials Required Tools Screw driver Screw driver Tweezers Tweezers Flashlight FlashlightHardware PC Case PC.
Trimble SPS730 and SPS930 Universal Total Stations
Lesson 3 How to Construct Your Own Personal Computer.
Installation. Indoor Unit Installation Typical Installation.
TouchIT Board Training.
Mercury G3 Service Tool Training Overview
Teacher/Mentor Institute Hands-On Session: Building a Robot Scott McEwen Chuck Powell.
Setting up the Ricoh C305 Press F5 to start the Presentation
Exacta ™ Digital Torque Wrenches Sturtevant Richmont Global Reach. Local Support.
Gauge Operation and Software by Scott A. Ager. Computer Recommendations 750 MHz Pentium III 64 Meg SRAM 40 Gig Hard Drive 1024 x 768 graphics CD Writer.
Image Downloading Instructions General Instructions.
Mercury G3 Service Tool Training Overview When opening G3 you will start at this screen first import thing to look for is communication.
LSM780 Live Cell Turn On/Turn Off Instructions Kim Peifley 07/13/15.
Automotive Electricity and Electronics, 3/e By James D. Halderman Copyright © 2011, 2009, 2005 Pearson Education, Inc., Upper Saddle River, NJ All.
BAE SYSTEMS PROPRIETARY – Internal Use Only Unpublished Work Copyright 2014 BAE Systems. All rights reserved. BAE Systems C2C SWAT Project - WF32 Shield.
Programming the Geiger Counter Board 1. Arduino Files Go to and download the latest Arduino.
WS50(Stratacache) Software updating guide (By Using USB)
Service Manual. Cubi Overview The service manual instructs the installing and removing the mSATA, memory card, Wifi card and 2.5 inch HDD.
Software Download Guide. 2/2/2016 Steps 1. Before you start to download software,please install USB driver(Folder: USB Driver) firstly. – Install “ InstallDriver.exe.
Lifeguard ® PO2 Sensors ‘Tee’ Tutorial © 2015 Cochran Consulting, Inc. Introduction PO2 Sensor Factors PO2 Sensor Tee Installation Cochran Consulting,
Important! Be sure to connect the communication cable to your computer before opening the Aqua4Plus Lite software. (Click to continue)
HDD Viewer The HDD Viewer is a tool that lets you playback and archive the video data on the hard disk from DVR( Digital Video Recorder ). By using HDD.
PRO OX ® -100 Kit PROGRAMMABLE DIGITAL OXYGEN MONITOR US & FOREIGN PATENTS ISSUED & PENDING STATE-OF-THE-ART TECHNOLOGY FOR PRECISE OXYGEN MONITORING MADE.
Chapter 27 Restraint System Repairs. Objectives Explain the difference between an active and a passive restraint system Learn how to service seat belts.
Hardware Configuration Guide Configuring Dongles and Creating Barcodes for Devices Used with VSC.
Rapid Change Technology The following is a presentation to aid Technicians in the replacement of the Rapid Change Technology Block.
1 ALARMLINC. 2 OVERVIEW Expanding Situational AwarenessOVERVIEW.
Sentek Training Presentation © 2003 All rights reserved Sentek Pty Ltd Sentek Sensor Technologies Installation of EasyAG 50 and EasyAG 80.
Touch Screen Voting Device Training Election Systems & Software Presented by: Bill Lowe.
RockOn! RockOn! Structure Build RockOn! 2009.
Analyst ® 5 Introduction 13 June 2016 Introduction Analyst Editions Analyst Libraries Connecting the USB Module © 2016 Cochran Consulting, Inc.
PostBase Automatic Feeder Component Removal Service Training
Scorpion is a remote tester specifically designed for testing ASD systems. Scorpion is compatible with the FAAST aspirating smoke detector. It is particularly.
Using the Mark-10 MESURGauge Software to Chart Force/Time
14 Refrigerant Recovery, Recycling, and Recharging.
Module – Groundwater Level Measurement
EILERSEN The Weighing experts.
SKC IS PROUD TO INTRODUCE A NEW LOW FLOW SAMPLING PUMP
Cochran Consulting, Inc.
1/17/2019.
Presentation transcript:

INW Sensor Technology …Continued

What we will cover Installation Practices Installation Practices Security Security Changing Batteries Changing Batteries Aqua4Plus Operation Aqua4Plus Operation Calibration Overview Calibration Overview

Installation Practices

Above Ground Monument Sensor Cable Well casing Strain relief Desiccant Service port Well cap Monument Steel or fiberglass monument Steel or fiberglass monument

Steel or fiberglass flush mounted lid Steel or fiberglass flush mounted lid Installation Practices Below Ground Monument Sensor Cable Well casing Strain relief Desiccant* Service port Well cap MonumentLid *Prone to flooding!! Keep desiccant dry or use absolute sensors.

Installation Practices Do not drop into well – Lower gently to prevent damage to end of sensor.

Installation Practices Do not scrape cable over edge of well – May nick or fray cable.

Installation Practices Do not bend cable sharply – This may close off vent tube*. *Gauge (vented) pressure sensors contain a vent tube inside the cable. If this vent tube is closed off, readings will be wrong.

Installation Practices Install in vertical position – Off vertical may introduce an offset.

Installation Practices Do not lower into mud or silt – This may clog or blind sensor.

Use a strain relief kit to prevent excess pulling on the cable. Installation Practices

Install so that service connector stays dry. Installation Practices

On vented pressure sensors… Install so as to keep desiccant dry. Installation Practices

Replace desiccant when it turns pink. Installation Practices Pink = Bad Blue = Good

Security Issues

Use locking monuments

Security Issues Paint to match surroundings plainpaintedplainpainted

Security Issues Surround with a fence

Security Issues Install caution signs or alarms

Security Issues Use passworded software

Security Issues Proprietary data formats and software

Changing Batteries

Should be done in a clean, dry environment to avoid contamination or moisture damage to the circuitry.

Changing Batteries Top- cap Cable O-rings AA batteries 1.Twisting gently, unscrew the top-cap. Note: Two O-rings provide a water-tight seal and often seal tightly. Pulling hard can cause the O-rings to release suddenly and the top-cap to disengage with enough force to pull the insides out of the sensor.

Changing Batteries 2.Gently separate the top-cap from the body of the sensor. Top-cap remains attached to body via several colored wires. 3.Gently slide batteries out. 4.Insert new batteries – positive terminals towards top-cap. 5.Replace and retighten top-cap.

Aqua4Plus Software Operation

Aqua4Plus Operation Connect the sensor to your computer via Serial Port

Aqua4Plus Operation Connect the sensor to your computer via USB Port

Aqua4Plus Operation Step 1: Select a COM port Select the COM port to which your sensor is connected.

Aqua4Plus Operation Step 2: Select a sensor and take real time readings Open the sensor window by clicking on the tool button.

Aqua4Plus Operation Step 2: Select a sensor and take real time readings On the sensor map, click on the desired sensor. General information about that sensor will display to the right.

Aqua4Plus Operation Step 2: Select a sensor and take real time readings Click on the Start button to view real time readings from the sensor.

Aqua4Plus Operation Step 3: Create a recording session Open the session window by clicking on the tool button.

Aqua4Plus Operation Step 3: Create a recording session Assign a name and then describe your recording session. Click the Start button to begin the session.

Aqua4Plus Operation Step 4: Retrieve data from sensor Start the data upload by clicking on the tool button.

Aqua4Plus Operation Step 5: View the data View your data by clicking on either the table tool button or the graph tool button.

Aqua4Plus Operation Step 5: View the data Table FormatGraph Format

Aqua4Plus Operation Step 6: Export data to.csv Export data to a.csv (comma separated value) file by clicking on the tool button.

Aqua4Plus Operation Step 6: Export data to.csv Export data can easily be imported into and viewed by many different analysis programs. MS Excel MS Access Modeling programs Data analysis programs

CalibrationOverview

Calibration Overview Aqua4Plus’ built in calibration calculator allows you to easily perform two-point calibrations on each channel.

Calibration Overview Using the interactive calculator, enter known points and take measurements. Aqua4Plus determines the needed calibration values.

Calibration Overview Step-by-step instructions display on the calibration window for ease of reference.

What we covered Installation Practices Installation Practices Security Security Changing Batteries Changing Batteries Aqua4Plus Operation Aqua4Plus Operation Calibration Overview Calibration Overview Summary

Questions?

Thank You! Instrumentation Northwest nd Ave NE, Kirkland WA, USA