ULTRA VIOLET STERILISER UV24 - 22/58 US gpm Cobalt SC & SCM 600.

Slides:



Advertisements
Similar presentations
MANGANESE GREENSAND To reduce high levels of Iron & Manganese with associated staining and the smell of Hydrogen Sulphide.
Advertisements

Drinking Water Treatment Seminar Leesville Middle School
Australian water filter.
Often water is prescreened, treated with ozone, or pre-chlorinated before entering the coagulation basin (depending on the quality of the water). Coagulation.
RK-60The Ultimate Solution to Community Water Problems A Water Treatment Unit producing clean water at 60 Litres per minute safeguarded from worms, cysts,
ULTRA VIOLET STERILISER 10Gpm – 15Gpm. Sterilight- S8Q PA 30 – 76 litres per minute S12Q PA 42 – 110 litres per minute 99.9% inactivation of even Giardia.
sanuvox – 101 A short lesson in UV Any bacteria can be destroyed with UV-C light; the question is how to do it? sanuvox technologies inc.
Ultraviolet Disinfection - BIO-SECURITY Specification, Operation and Maintenance in a New Era 2010 Regional Aquatics Workshop Presented By: Adrian Megay.
Proven, Affordable, Environmentally Friendly …defining UV innovation…
IMPERIAL AQUA K CERAMIC FILTER. Filters Imperial Aqua K Ceramic Filter Comprised of two filters that can be fitted under the kitchen sink, this compact.
Common Water Treatment Problems Hard Water -Calcium and Magnesium. Soap Scum, and Scale Build-Up. Iron - Clear (Ferrous), Red (Ferric), & Bacteria Related.
MANGANESE GREENSAND To reduce high levels of Iron & Manganese with associated staining and the smell of Hydrogen Sulphide.
Operation of the FW-720 Unit 1. Side 1 2 Inlet Hand Crank.
ACTIVATED CARBON Granular Activated Carbon may be used for a variety of water treatment applications requiring the reduction of chlorine, tastes, and odours.
SV Line d.o.o.1 Pause (S) Continue (N).
Zelienople Water Department Sources and Treatment.
Ice. Pure and Simple ™ Welcome to the Ice-O-Matic ® on-line training modules.
Dialysis Water Treatment Systems
C. T Calculation Math for Water Technology MTH 082 (pg. 468) Math for Water Technology MTH 082 (pg. 468) “Required by Law”
Water Purification in the Backcountry. Biologically contaminated water contains infection- causing microorganisms such as Giardia, bacteria, or viruses.
WelcomeWelcome BURT PROCESS EQUIPMENT “Harvesting The Rain” Rainwater Reclamation.
DOULTON ‘ICP’ WATER FILTER Doulton Ceramic Filtration – A Proven System.
Potential Pathways for Coliform Contamination. Fixing Positive Coliform Results.
Maintenance of water cooler & water filter Sr. S. Chandra - Housekeeper.
BIRM For the reduction of rusty/brown/black staining and metallic taste resulting from Iron and/or Manganese in water.
Antunes Water Filtration Technologies Introduces to You:
ULTRA VIOLET STERILISER 10Gpm – 15Gpm – 24Gpm. Sterilight – UV S12Q-PA litres per minute  99.9% inactivation of even Giardia and Cryptosporidium.
Rural Surface Water Rivers, Creeks and stock water supplies vulnerable to heavy sediment levels and high turbidity.
MARKEL Reverse Osmosis Water Purifiers. Markel Unit  There are many people living in rural areas, very worried about the increasing Nitrate levels in.
Well Disinfection Math for Water Technology MTH 082 Lecture
Water Treatment System Design for Cinnamon Creek Campground Nomads Engineering: Achit-Erdene Gankhuyag Cuyler Frisby Kevin Wagner.
Groundwater Math Math for Water Technology MTH 082 Lecture 2 Well Drawdown, Well yield, Specific Capacity, Well Disinfection Course Reader Week 2 Chapter.
Water Treatment for NYC Croton Schematic. NYC Filtration Plant for Delaware and Catskill Systems  Filtration avoidance criteria  Alternatives to Filtration.
Math for Water Technology MTH 082 (pg. 468)
Water Treatment for NYC Croton Schematic. NYC Filtration Plant for Delaware and Catskill Systems ä Filtration avoidance criteria ä Alternatives to Filtration.
FILTER-AG PLUS ® Automatic backwashing unit to dramatically reduce sediment and colour in rural surface water.
Lecture 4: Free chlorine and hypochlorite Prepared by Husam Al-Najar The Islamic University of Gaza- Environmental Engineering Department Environmental.
OZONE DRINKING WATER SYSTEM. CONTENTS Properties of Ozone Production of Ozone Water Treatment Plant – 25 m 3 /hr Ozone Generation System.
Lease Automatic Custody Transfer
How to obtain fresh water Section - E6.3 Chemistry 12 – SL Isabelle R.
Processing, distribution and use of water.
NSF International Drinking Water Product Standards.
Dr. Joel J. Ducoste, North Carolina State University, 1 Importance of water “Water is life” Looking at water, you might think that it's the most simple.
Environmental Engineering Lecture 7 Dr. Hasan Hamouda.
C3 2.3 Water Treatment.
Water Analysis & Control. Water analysis & control WATSAN M15 ERU 2 Contents 1.Chemical parameters and ranges 2.Water sources: Sampling procedures 3.Laboratory.
Water Supply in the Field. Objectives Importance of safe water in the field ResponsibilitiesDefinitions Rules for water use Types of sources and considerations.
An Introduction to Our Water Filtration Systems. Where Do We Work? 4,078 Students The Dominican Republic Haiti 9 Schools 8,803 Students 10 Schools.
‘Purification Station’ Farr High School Young Engineers.
Date: Monday, May 11 th 2015 Topic: Water Purification Objective: To recognize the stages of it.
Disasters change things. Things that we take for granted every day may be hard to find.
1. According to the water supply department, drinking water in a modern city should be (I) only (I) & (II) only (I), (II) & (III) (I), (II), (III) & (IV)
Water Purification By Sam Swidler. How much water is on this planet? Water covers at least 71% of the Earth's surface. It is impossible to tell exactly.
SPOT ZERO REVERSE OSMOSIS SYSTEM Welcome to Elite Marine Services.
ENVIRONMENTAL SCIENCE 5.3 Before You Drink the Water.
Safe, Clean and Drinkable
Water Treatment Basics
REVERSE OSMOSIS PLANTS 5-35kl/day
Powdered Milk Plant Design
Lecture (9): Monitoring & sampling methods, maintenance ,
REVERSE OSMOSIS PLANTS kl/day
NSF International Drinking Water Product Standards
Treatment – Chlorine Disinfection
Treatment – Sediment Filters
Treatment – Ultraviolet (UV)
Water Treatment.
Treatment – Plant Design
Maximum Contaminant Levels
Safe Drinking Water.
Presentation transcript:

ULTRA VIOLET STERILISER UV /58 US gpm Cobalt SC & SCM 600

Sterilight – Cobalt SC & SCM litres per minute  4-log (99.99%) destruction of E.coli and other bacteria, virus and protozoan cysts (Giardia and Cryptosporidium) at rated flow.  Cobalt ICE controller with audible alarm lamp failure as well as visual display for remaining lamp life and total days of operation and in the monitored systems, % UV output.  Compact design incorporating 304 stainless steel reactor chamber, 1” ports  Easy servicing – no need to disconnect water flow to change UV lamp  Up to litres per minute and still achieve UV dosage approx 3 times higher than required to eradicate E.coli bacteria.  Monitored systems have a true 254nm UV intensity monitor to warn you of any change in water quality that may cause the water to be unsafe to drink  Optional solenoid and remote monitoring  Seven year warranty on reactor chamber  Five year pro-rata warranty on ballast  One year pro-rata replacement on UV lamp

Ultra Violet Lamps  Disinfection using ultraviolet (UV) light is recognised as the ecological choice in disinfection techniques.  UV effectively destroys microbiological contaminants without adding anything to the water and creates no residual by-products.  It is recommended that no rural surface waters be consumed without adequate microbiological treatment, regardless of test results.  Ultraviolet sterilisers incorporate natural ultraviolet light energy to eradicate microbiological contamination.  High quality units are guaranteed to be virtually 100% effective against Spores, Algae, Moulds, Viruses, a wide range of Bacteria, and even Giardia and Cryptosporidium cysts.  Some UV units rely on 1micron filtration to reduce cysts – a less effective and unreliable method.  The Ultra violet unit has a stainless steel chamber and inside, a quartz sleeve -like a glass tube (that the UV bulb fits within), with the water swirling around it throughout the length of the unit.  The water enters near one end and exits near the other, treated and safe for use.

Ultra Violet Lamps  The stainless steel unit is usually mounted in the pump shed or where the water enters the property, so all water flows through the unit, thus every tap would be treated for microbiological contaminants and be safe for use.  Lamp can be changed without interrupting the water flow  A 5-micron filter cartridge is needed to ensure the water is clear enough for the Ultra Violet rays to penetrate the water to achieve the desired kill rates.  UV treatment does not reduce any chemicals or smell/taste.  If these contaminants are of concern you may consider an additional ‘Big Blue’ housing fitted with a refillable carbon cartridge to treat all the water for the whole house, or an underbench water filter unit such as the “AQUA K” for food preparation, cooking and all drinks.

Installation and Water Flow  In areas prone to power surges, power outages or electrical storms, Surge protection devices or Uninterruptible Power Supplies (UPS) should be fitted.  If Mounting horizontally, flow can go either way but ports must be uppermost.  If Mounting vertically, flow must come in from the bottom port. In all cases, remember to leave room for the lamp and quartz sleeve to be extracted

Operational Maintenance and monitoring UV has no residual effect – it only works while the organisms are in the reactive chamber  Upon commissioning, all downstream lines must be chemically disinfected  Thereafter, periodic chemical disinfection as least once every 3 months should be undertaken. UV dosage is effected by poor transmittance of the light or sediment in the water  Ensure all pre-filters and conditioners are sized appropriately and regularly checked and cleaned or replaced as necessary  Periodically check quartz sleeve and clean as necessary  Replace lamp every 12 months or 9000 hours UV effectiveness is directly related to dosage (i.e. Contact time or organisms to the UV light)

Installation

Large Surface Type Filtration  Complete with powder coated mounting bracket, bolts, plus opening spanner.  Available in 10” or 20” with 1” ports  Pressure release button to ease opening of the housing during maintenance. Also to bleed air out on start-up.  Pleated Polyester Filter Reusable/Washable (for coarse dirt loadings).  20 micron, 5 micron & 1 micron.  Highly efficient pleated filter cartridges for low pressure drop, high flow capability, increased dirt removal, long filter runs – which all adds up to the lowest cost per Litre filtered

Specifications Water passed through the unit must fall within the following parameters:  Iron: <0.3mg/L  Hardness: <120mg/L  Turbidity: <1NTU  Manganese: <0.05mg/L  Tannins: <0.3mg/L  UV Transmittance: >75% (call factory for recommendations on applications where UVT <75%) * Where total hardness is less than 120mg, the UV unit should operate efficiently provided the quartz sleeve and/or sensor probe is cleaned periodically. If total hardness is over 120mg the water should be softened 1.Assumes water does not contain any physical staining components which could potentially cloud the UV transmission 2.Protozoa – Giardia, Cryptosporidium etc

Flow Rate and UV Dosage The Flow rate is approximately 5 times greater than is required to destroy E.coli E.coli eradicated at 6.6 mJ/cm² Cryptosporidium & Giardia lamblia eradicated at <10 mJ/cm²

Disinfection of Lines After the BB Housing and the UV Unit have been installed and are operating all downstream water lines must be disinfected. If preferred and to save disinfecting the whole tank, a generous quantity of bleach can be poured into the BB Housing. The Housing is then closed and water run through until chlorine is detected at each tap in the house. Close each tap and leave for as long as possible (preferably overnight) for the strong chlorine solution to disinfect all the water lines. Open the taps and flush out the chlorine solution, with the UV treated water. Calculating Your Tank Volume: Square Tank Volume in litres is equal to length x width x depth of water x (All measurements of tank dimensions should be made in metres).  For example, a cubic tank measuring 1m x 1m x 1m would have a volume of 1 x 1 x 1 x 1000 = 1000 litres. Circular Tank: Measure the diameter and the depth of water. The tank volume in litres is equal to x diameter x diameter x depth x  For example a tank 1 metre in diameter and 1 metre deep would have a volume of x 1 x 1 x 1 x 1000 = 785 litres. The disinfection Tables, can be used to calculate the amount of household bleach you would need.  For example, a tank with a volume of 1000 litres requiring 5 g/m³ for disinfection purposes needs 167ml of plain household bleach. An accurate measure, such as a graduated measuring container, should be used to measure the bleach. As a rough guide, cups are approximately 250ml and milk bottles 600ml. A 167 ml measure is approximately two thirds of a cup. After you have dosed your tank and mixed it well, the dosed water should be run through all your household lines so that the newly disinfected water comes through the taps.

Disinfection Table  To use Table 1. Calculate volume of tank in litres 2. Select dose rate required at top of the table: *1 g/m³ routine disinfection for clean water *2 g/m³ routine disinfection for reasonably clean water *5 g/m³ period disinfection for tanks and pipes *10 g/m³ superchlorination for biological contaminated tanks. Remove contamination, allow water to sit for 24 hours before drawing. Boil before drinking 3. Read the amount of sodium hypochlorite (in millimeters) to be added where the dose required corresponds to the volume of the tank 4. Add required millilitres of fresh plain household bleach and mix thoroughly.

 For any further enquiries or information please contact:  Sue Kelly  Free Phone:  E mail: