Professor: Scott M. LaBrake Course: Physics 300 – Spring 2013 Office: NWSE N308, N008b Phone: 388-6053 & 6562 Office Hours: MWF.

Slides:



Advertisements
Similar presentations
Radioactivity.
Advertisements

X-ray Photoelectron Spectroscopy
Ground vs. Excited State
Cphys351 c4:1 Chapter 4: Atomic Structure The Nuclear Atom The Atom as the smallest division of an element quantization of electric charge oil drop experiments.
Ion beam Analysis Joele Mira from UWC and iThemba LABS Tinyiko Maluleke from US Supervisor: Dr. Alexander Kobzev Dr. Alexander Kobzev.
Determining the Valence State of Lead in Compounds Using PIXE Andrew Voter Nuclear group July 23, 2007.
Ion Beam Analysis techniques:
Saeedeh Ghaffari Nanofabrication Fall 2011 April 15 1.
Early Quantum Theory and Models of the Atom
ATOMIC STRUCTURE. Objectives: SWBAT Identify three subatomic particles and compare their properties. Distinguish the atomic number of an element from.
Calculations of Characteristic X Ray Energies and Wavelengths and the PIXE Spectrum Physics 100 – PIXE – F06.
 When a gas in a tube is subjected to a voltage, the gas ionizes, and emits light.  We can analyze that light by looking at it through a spectroscope.
Medical Imaging Dr. Hugh Blanton ENTC 4390.
Rutherford Backscattering Spectrometry
X-radiation. X-rays are part of the electromagnetic spectrum. X-radiation (composed of X-rays) is a form of electromagnetic radiation. X- rays have a.
PIXE: Data Analysis What the data can (and cannot) tell us. Larry Lamm PIXE Seminar Winter 2008.
Physics at the end of XIX Century Major Discoveries of XX Century
Chapter 31 Atomic Physics Early Models of the Atom The electron was discovered in 1897, and was observed to be much smaller than the atom. It was.
Physics 100 – Module 5 Materials Science and Materials Analysis using a Particle Accelerator Instructor: Scott M. LaBrake, Ph.D. Office: N331, N008B Office.
Neutral Particles. Neutrons Neutrons are like neutral protons. –Mass is 1% larger –Interacts strongly Neutral charge complicates detection Neutron lifetime.
Trace Elemental Composition and Concentration of Upstate New York Rainwater Samples Using the Union College Pelletron Particle Accelerator and Proton Induced.
ATOMIC STRUCTURE. Atomic Structure All matter is composed of atoms. Understanding the structure of atoms is critical to understanding the properties of.
Dual Nature of Light. Light Quanta. Photoelectric Effect.
A Pyro-Electric Crystal Particle Accelerator Chelsea L. Harris, Texas Southern University Dr. Rand Watson, Texas A&M University Cyclotron Institute Pyroelectric.
Rutherford Backscattering Spectrometry
W.N. Catford/P.H. Regan 1AMQ 83 Characteristic X-rays and Selection Rules. Characteristic X-rays: are emitted by atoms when electrons make transitions.
4.1The Atomic Models of Thomson and Rutherford 4.2Rutherford Scattering 4.3The Classic Atomic Model 4.4The Bohr Model of the Hydrogen Atom 4.5Successes.
Atomic Structure. X-ray Spectrum Continuous spectrum Characteristic spectrum.
Radiation. When you see or hear this word what do you think about? What do you think it means? Share your thoughts with me by writing on the post it what.
6. Atomic and Nuclear Physics Chapter 6.6 Nuclear Physics.
Bell work: Think about what we did on Friday. Explain what an “energy level” is. Is it related to electron shells? What happens when an electron “drops.
Stopping Power The linear stopping power S for charged particles in a given absorber is simply defined as the differential energy loss for that particle.
Physics 1C Lecture 29A.
When heated to high temps, gases give off light. If this light is passed through a slit, then through a prism or diffraction grating, the following patterns.
Construction of a Scattering Chamber for Ion-Beam Analysis of Environmental Materials in Undergraduate Physics Research Scott LaBrake, Michael Vineyard,
 How does the wavelength of a light beam and the size of a slit it is going through control the amount of diffraction? DO WORK STOP.
Scanning Electron Microscope (SEM) – Shoots a high energy beam of electrons (waves of electrons) at a target. Electron gun Focusing coil Objective lens.
Ion Beam Analysis Dolly Langa Physics Department, University of Pretoria, South Africa Blane Lomberg Physics Department, University of the Western Cape,
Space Instrumentation. Definition How do we measure these particles? h p+p+ e-e- Device Signal Source.
Arrangement of Electrons. Spectroscopy and the Bohr atom (1913) Spectroscopy, the study of the light emitted or absorbed by substances, has made a significant.
The atom and its nucleus By the end of this chapter you should be able to: appreciate that atomic spectra provide evidence for an atom that can only take.
 According to Bohr’s model of the atom, atoms are very similar to solar systems.
1 Alpha Decay  Because the binding energy of the alpha particle is so large (28.3 MeV), it is often energetically favorable for a heavy nucleus to emit.
2. RUTHERFORD BACKSCATTERING SPECTROMETRY Basic Principles.
Monday, March 23, 2015PHYS , Spring 2014 Dr. Jaehoon Yu 1 PHYS 3313 – Section 001 Lecture #13 Monday, March 23, 2015 Dr. Jaehoon Yu Bohr Radius.
Atomic and Nuclear Physics
Nuclear Physics. The famous Geiger-Marsden Alpha scattering experiment (under Rutherford’s guidance) In 1909, Geiger and Marsden were studying how alpha.
Cosmic rays at sea level. There is in nearby interstellar space a flux of particles—mostly protons and atomic nuclei— travelling at almost the speed of.
Chapter 28:Atomic Physics
Rutherford’s Model: Conclusion Massive nucleus of diameter m and combined proton mass equal to half of the nuclear mass Planetary model: Electrons.
Chemistry 068, Chapter 9.
Copyright © 2010 Pearson Education, Inc. Lecture Outline Chapter 2 Light and Matter.
X-ray microanalysis in the electron microscope
Basics of Ion Beam Analysis
Topic: Electrons in Atoms Ground/Excited States Do Now: List the charge, number of protons, and number of electrons for: 1.Ca +2 2.Fe +3 3.F -1 4.P -3.
UNIT 3 ELECTRON CONFIGURATION AND MODERN ATOMIC THEORY.
Rutherford Backscattering Spectrometry (RBS)
Atomic Structure Notes. 2 Atomic Structure Subatomic particles include ________, _________ and _________. protons neutrons electrons ________ and _________.
Atomic Structure. Model A: The plum pudding model J.J. Thompson Negative charges like raisins in plumb pudding Positive charge is spread out like the.
Radioactivity By the end of this chapter you should be able to: describe the properties of alpha, beta and gamma radiations; explain why some nuclei are.
INTERACTIONS OF RADIATION WITH MATTER. twCshttp:// twCs
History of Atomic Theory Figuring Out Atoms. Dalton’s Atomic Theory 1.Matter is composed of extremely small particles called atoms. 2.Atoms are indivisible.
Resident Physics Lectures Christensen, Chapter 2C Production of X-Rays George David Associate Professor Department of Radiology Medical College of Georgia.
The Particle Model of Light and Atomic Emission and Absorption
Lesson outline Atomic size (radius) trends Ionization energy trends Ions Ions Electron affinity and electronegativity activity Electron affinity trends.
Goal 5.01 Atomic Theory. Basic Laws of Chemistry Law of conservation of massLaw of conservation of mass: mass is neither created or destroyed during chemical.
Trace Elemental Composition and Concentration of Upstate New York Rainwater Samples Using the Union College Pelletron Particle Accelerator and Proton Induced.
General Physics (PHY 2140) Lecture 33 Modern Physics Atomic Physics
Electronic Structure of the Atom
ATOMIC STRUCTURE.
Presentation transcript:

Professor: Scott M. LaBrake Course: Physics 300 – Spring 2013 Office: NWSE N308, N008b Phone: & 6562 Office Hours: MWF 9:30 am – 11:30 am Th 8:30 am – 11:30 am and by appointment. Actually you probably can just stop by anytime, I’m usually around. Web:

Proton Induced X-Ray Emission (PIXE) Spectroscopy Modern materials analysis technique that uses a moderately energetic particle beam to eject electrons from a target material. Characteristic x-rays are produced from each of the elements in the target material. PIXE is a non-destructive technique and the analyses are sensitive for elements in the range of Na to U. (To complete the periodic table we use other complementary analysis techniques such as PESA, PIGE, and RBS.) PIXE is used in fields from biology, medicine, forensics, art conservation, archeometry, materials analysis and environmental pollution. In this experiment we’ll learn the PIXE method and apply this nuclear physics technique to the analysis of atmospheric aerosols and environmental pollution.

Photograph of the Union College Pelletron Accelerator showing the major components. The NEC Tandem 1.1 MV Pelletron Particle Accelerator

PIXE chamber Target Manipulator The NEC Tandem 1.1 MV Pelletron Particle Accelerator Photograph of the accelerator endstation. The proton beam enters through the right end passes through the target in the center of the multi-way cross and exits out of the pipe on the left end. The 3-axis target manipulator is mounted on the top of the scattering chamber.

Charge-exchange collision to produce negative ions. Positively charged particles are pulled to right by negatively biasing the quartz bottle. The positive ions pass through a small opening into a Rb vapor where they pick up a negative charge. Then these negatively charged ions are accelerated toward the center of a high pressure tank which has a large positive potential. The negative ions are passed through a N gas and are stripped of their excess charge and are accelerated away from the positive terminal held at 1.1MV. Protons are accelerated once towards the center of the tank (for the extra e - ) and once away (for the lone proton) for 2.2MeV worth of KE. Alpha particles are accelerated once towards the center of the tank (for the extra e - ) and once away (for each proton) for 3.3MeV worth of KE. Both the proton and the alpha particle are non-relativistic. H-H- H+H+

This is the particle accelerator’s column. In the center is the terminal shell where the 1.1MV worth of potential is developed (with respect to the ends at ground.) The rings are used to create a potential gradient so that the potential builds up (or is removed) in a uniform (linear) fashion. The NEC Tandem 1.1 MV Pelletron Particle Accelerator

This is the high energy column showing the Pellets (which give the Pelletron its name) and the charging system. The terminal shell is usually over the top of the wheel at the right. As the proton passes through the terminal shell, Nitrogen gas is bled into the beampipe at the center of the terminal shell. Through the same charge exchange collision process the extra electrons are stripped from the proton. The NEC Tandem 1.1 MV Pelletron Particle Accelerator

PIXE – Proton Induced X-ray Emission PIXE is a non destructive materials Analysis tool. X-Ray Emission Incident particle interacts with target ejecting electrons. Electrons are ejected from shells of atoms in the sample vacancy is filled by an electron from a higher shell emitting a characteristic x-ray in the transition. Data Acquisition X-ray detector and software to record energy spectrum Need to calibrate x-ray detector with 241 Am.

Possible x-ray transitions for an arbitrary atom of nuclear charge Z. We identify the elements based on their x-ray emission spectra. Each element has its own unique set of x-ray emission lines allowing us to fingerprint them. PIXE is sensitive to elements in the range of Na to U. The light elements are determined by their K-series x- rays, while heavy elements are determined by their L- series x-rays. When an electron transitions between states, the emitted photon energy is given by: If the electron is ejected from the ground state (or the K-shell) an electron from a higher orbital will fill the vacancy that was created. The lowest energy (highest probability) is called the  -transition. The next higher energy (lower probability) transition is called the  -transition. We identify the elements based on identifying usually the K  transition (and if lucky the K  also.) We usually are not this lucky… And if the element is heavy we look for the corresponding L series transitions. PIXE – Proton Induced X-ray Emission

Each state has an associated kinetic energy (due to the electron’s motion about the nucleus), and a potential energy (due to the separation of electric charges between the nucleus and the electron in it’s orbital). For a K series transition, the transitioning electron is screened from the full nuclear charge due to the remaining electron in the ground state. Thus the transitioning electron sees the nuclear charge (Ze) and one electron (-e) or a total charge of (Z - 1)e. Applying the Bohr theory and writing the kinetic and potential energies in terms of the the quantized orbits, one can write the energy of the emitted photon when the electron transitions from an upper to a lower energy state as: From the energy of the emitted x-ray (knowing the transitions n upper and n lower ) we could calculate Z. This is really difficult. The transitions are tabulated as a function of Z. Calibration of the energy scale in the emitted spectra (using standards) allows us to use the energy of a given x-ray from the spectrum generated to look up Z. PIXE – Proton Induced X-ray Emission

On the left a photograph of a typical aerosol impaction foil. The foils are made out of Kapton and are approximately 6.3  m thick. These are put in the impactor and air is drawn through the nine stages at a rate of 1 L/min for about 48hours. The photograph on the right is a Kapton impaction foil after it has been run in the impactor. The hard part about determining concentrations in ng/cm 3 is determining the area of the impaction spot and the area of the beam that hits the Kapton foil. PIXE – Proton Induced X-ray Emission

Nine stage cascade impactor. Air is drawn up through the bottom and as the air moves up through the impactor particles of different sizes are separated out. The farther up the impactor the air goes the smaller the particle sizes that are trapped. The largest particles are trapped at the bottom of the impactor. On the far right this is the impactor assembly ready to collect samples. PIXE – Proton Induced X-ray Emission

Left is a photograph of the target ladder assembly. Three targets are able to be run at a time. Below is a photograph of the target ladder assembly in place with the x-ray detector nose on the right hand side. The beam enters from the right and proceeds to the right.

Typical atmospheric aerosol sample with the peaks labeled. Our analysis software is GUPIX and GUPIX will calculate the concentrations for you provided you’ve calibrated your spectra and GUPIX using standards.

This experiment is an application of nuclear physics to environmental physics. Here we’ll use a 2.2MeV proton beam to eject electrons from the target and from the x-ray spectrum determine the elemental composition of the target. For the lab experiment, we’re going to run 3 or 4 standards (Cu, Fe, Au, and/or Pb) and determine the experimental value of H by making a plot of H vs Z. To determine H for each standard you’ll need to use the data analysis software GUPIX which is explained fully in the lab manual. In order to use GUPIX you’ll need to tell the program the energy calibration parameters (channel number as a function of energy) of your x-ray detector. There is a table in the lab manual to do this. Then your task is to determine the elemental composition and concentration of one (perhaps two) atmospheric aerosol samples. PIXE – The Experiment

Some general information… For the lab write-up follow the lab guidelines. Less is more in terms of actual writing! Now that doesn’t mean write a page and that’s better, you need to express your thoughts and ideas and make sure that they are clear to the reader. Pretend that the reader is someone who has never seen or done the experiment before. Due Dates for the labs – The lab report is due on or before noon on Friday, May 24, Lateness 10 percent per day late, including weekends. You may submit electronic copies of the lab report and any supporting materials that you have. Make sure it is complete when you submit the report or its considered late. PIXE – The Experiment