Pulsed Multiple Reaction Monitoring Mode: The Novel Sensitive Approach for Biomolecule Quantitation Mikhail Belov, Satendra Prasad, David Prior, William.

Slides:



Advertisements
Similar presentations
Cruces-Blanco, C., Gamiz-Gracia, L., Garcia-Campana A.M., Applications of Capillary Electrophoresis in Forensic Analytical Chemistry Trends in Analytical.
Advertisements

David Campbell 1,, Eric Deutsch 1, Henry Lam 1, Hamid Mirzaei 1, Paola Picotti 2, Jeff Ranish 1, Ning Zhang 1, and Ruedi Aebersold 1,2,3 1.Institute for.
Protein Quantitation II: Multiple Reaction Monitoring
Performance of a Hybrid RF/DC Quadrupole-Linear Ion Trap Mass Spectrometer James W. Hager MDS SCIEX ASMS, 2002.
The Proteomics Core at Wayne State University
Micromass Quattro Ultima triple quadrupole mass spectrometric detector HPLC system (LC) Electrospray ionisation source (-ve & +ve ion) Photodiode array.
LC-ESI-MS/MS analysis of nine basic pharmaceuticals in influent, effluent and surface water Jet C. Van De Steene and Willy E. Lambert Laboratory of Toxicology,
Inductively Coupled Plasma Mass Spectrometry or ICP-MS
* CORRESPONDING AUTHOR Bioanalysis of Exenatide: Intact Versus Signature Peptide Approach to Reach Optimal Sensitivity in Large Molecule Quantification.
Proteored Multicentric Experiment 8 (PME8) Quantitative Targeted Analysis in Proteomics. An Assesment Study (QTAPAS) ProteoRed WG1-WG2 Meeting Pamplona,
Chiral Separation By Ion Mobility Spectrometry Herbert H. Hill Jr 1., Prabha Dwivedi 1, and Ching Wu 2 1 Department of Chemistry & Center for Multiphase.
Lecture 8. GC/MS.
Quantification of low-abundance proteins in complexes and in total cell lysates by mass spectrometry Bastienne Jaccard and Manfredo Quadroni Université.
A Miniature Ion Mobility Spectrometer for Explosives Detection Andrew Goodin, William F. Siems, Christina L. Crawford, Prabha Dwivedi, and Herbert H. Hill,
Proteomics The proteome is larger than the genome due to alternative splicing and protein modification. As we have said before we need to know All protein-protein.
LC-MS Lecture 7.
Mass Spectroscopy Quantitative Chemical Analysis Harris, 6th Edition
LC/MS WORKSHOP IOWA STATE UNIVERSITY Kamel Harrata  Instrument Description  Data Acquisition  Data Processing.
Proteomics Informatics Workshop Part I: Protein Identification
Instant Notes Analytical Chemistry
FIGURE 5. Plot of peptide charge state ratios. Quality Control Concept Figure 6 shows a concept for the implementation of quality control as system suitability.
Proteomics Informatics Workshop Part III: Protein Quantitation
Gas Chromatography And Mass Spectrometry
Proteomics Informatics – Overview of Mass spectrometry (Week 2)
Tryptic digestion Proteomics Workflow for Gel-based and LC-coupled Mass Spectrometry Protein or peptide pre-fractionation is a prerequisite for the reduction.
Comparison of chicken light and dark meat using LC MALDI-TOF mass spectrometry as a model system for biomarker discovery WP 651 Jie Du; Stephen J. Hattan.
Zlata D. Clarka, M. Laura Parnasb and Elizabeth L. Frankb
Wilkes University - CHM D Gas Chromatography (or 3D with MS Detector) A powerful separations tool for complex volatile mixtures of heat-stable samples.
Chapter 9 Mass Spectrometry (MS) -Microbial Functional Genomics 조광평 CBBL.
Molecular mass spectrometry Chapter 20 The study of “molecular ions” M + e -  M e -
Quantitative Insulin Analysis Using Liquid Chromatography–Tandem Mass Spectrometry in a High- Throughput Clinical Laboratory Z. Chen, M.P. Caulfield, M.J.
1 Chemical Analysis by Mass Spectrometry. 2 All chemical substances are combinations of atoms. Atoms of different elements have different masses (H =
Integrated Targeted Quantitative Method for Insulin and its Therapeutic Analogs Eric Niederkofler 1, Dobrin Nedelkov 1, Urban Kiernan 1, David Phillips.
Analysis of Biomolecules through Nanomaterials Based Mass Spectrometry
Novel Algorithms for the Quantification Confidence in Quantitative Proteomics with Stable Isotope Labeling* Novel Algorithms for the Quantification Confidence.
For all CHEM5161 students: The first day of class for CHEM5161 (Analytical Spectroscopy) will be on TUE Sept 4 (following Labor Day). There will be no.
Mass spectrometry (Test) Mass spectrometry (MS) is an analytical technique that measures masses of particles and for determining the elemental composition.
* CORRESPONDING AUTHOR Glucagon Bioanalysis by LC-MS: “Unprecedented Level of Sensitivity (10pg/mL) for a Novel Formulation” Jean-Nicholas Mess 1, Louis-Philippe.
LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY
© Copyright 2009 by the American Association for Clinical Chemistry Plasma Renin Activity by Liquid Chromatography– Tandem Mass Spectrometry (LC-MS/MS):
Proteomics Informatics (BMSC-GA 4437) Instructor David Fenyö Contact information
Mass Spectrometry Quantitative Mass Spectrometry
Salamanca, March 16th 2010 Participants: Laboratori de Proteomica-HUVH Servicio de Proteómica-CNB-CSIC Participants: Laboratori de Proteomica-HUVH Servicio.
2014 생화학 실험 (1) 6주차 실험조교 : 류 지 연 Yonsei Proteome Research Center 산학협동관 421호
LC separation and MS of histone tryptic peptides allow for their post-translational modification quantitation -For most K residues our histone assay, we.
Chapter 29 Mass Spectrometry. 29 A Principles of mass spectrometry In the mass spectrometer, analyte molecules are converted to ions by applying energy.
Introduction to Liquid Phase Mass Spectrometry
RANIA MOHAMED EL-SHARKAWY Lecturer of clinical chemistry Medical Research Institute, Alexandria University MEDICAL RESEARCH INSTITUTE– ALEXANDRIA UNIVERSITY.
Evolution GC-MS/MS: Pesticide analysis in canola oil Evolution GC-MS/MS: Pesticide analysis in canola oil Vivian Watts 1, Ingo Christ 1, Mark Misunis 2.
Yonsei Proteome Research Center Peptide Mass Finger-Printing Part II. MALDI-TOF 2013 생화학 실험 (1) 6 주차 자료 임종선 조교 내선 6625.
Target Analyses in Parallel Reaction Monitoring Mode (PRM)
이 장 우. 1. Introduction  HPLC-MS/MS methodology achieved its preferred status -Highly selective and effectively eliminated interference -Without.
H M Arif Ullah, Hye Jin Chung*
Mass Spectrometry makes it possible to measure protein/peptide masses (actually mass/charge ratio) with great accuracy Major uses Protein and peptide identification.
Dr Berwyck Poad Compiled: 3 February 2017 Updated: 28 March 2017
Tandem MS.
Supplemental figures. Observed extracted ion chromatograms (XICs) of each of the ten peptides from five standard proteins using dual ion funnel and standard.
Multiple Reaction Monitoring (MRM) Selected Reaction Monitoring (SRM)
For Forensic Toxicology use Only
Tandem MS.
A sensitive and repeatable method for characterization of sulfonamides and trimethoprim in honey using QuEChERS extracts with Liquid-Chromatography-Tandem.
Mass Spectrometry Obaid M. Shaikh.
KTYDSYLGDDYVR Linearity
Protein/Peptide Quantification
Proteomic Approaches to Cancer Biomarkers
Volume 20, Issue 12, Pages (December 2013)
Mass Spectrometry THE MAIN USE OF MS IN ORG CHEM IS:
Shotgun Proteomics in Neuroscience
M.Prasad Naidu MSc Medical Biochemistry, Ph.D,.
Mass spectrometry (MS) is an analytical technique that can be used to determine the mass, elemental composition or chemical structure of molecules. Mass.
Presentation transcript:

Pulsed Multiple Reaction Monitoring Mode: The Novel Sensitive Approach for Biomolecule Quantitation Mikhail Belov, Satendra Prasad, David Prior, William Danielson, Karl Weitz, Vladislav Petyuk, Yehia Ibrahim and Richard Smith Pacific Northwest National Laboratory, Richland, WA Introduction Overview Methods Results Acknowledgements Portions of this work were supported by the National Center for Research Resources, grant RR and National Cancer Institute, grant R33 CA Samples were analyzed using capabilities developed under the support of the NIH National Center for Research Resources (RR18522) and the U.S. Department of Energy Biological and Environmental Research (DOE/BER). Significant portions of the work were performed in the Environmental Molecular Science Laboratory, a DOE/BER national scientific user facility at Pacific Northwest National Laboratory (PNNL) in Richland, Washington. PNNL is operated for the DOE by Battelle under contract DE-AC05- 76RLO References 1.Belov, M.E.; Gorshkov, M. V.; Udseth, H. R.; Anderson, G. A.; Tolmachev, A. V.; Prior, D. C.; Harkewicz, R.; Smith, R. D. J. Am. Soc. Mass Spectrom. 2000, 11, Wouters, E. R.; Splendore, M.; Mullen, C.; Schwartz, J. C.; Senko, M. W.; Dunyach, J. J. 57 th Conference of American Society for Mass Spectrometry; Ibrahim, Y.; Belov, M. E.; Tolmachev, A. V.; Prior, D. C.; Smith, R. D. Anal. Chem., 2007, 79, Clowers, B.H.; Ibrahim, Y.M.; Prior, D.C., Danielson, W.F., Belov, M.E.; Smith R.D. Anal. Chem., 2008, 80, Conclusions CONTACT: Mikhail Belov, Ph.D. Biological Sciences Division, K8-98 Pacific Northwest National Laboratory P.O. Box 999, Richland, WA This work reports on the improved limit of detection of a liquid chromatography (LC)-triple quadrupole instrument operating in the multiple reaction monitoring mode (MRM) by incorporation of an ion funnel trap (IFT) between an ion source and a quadrupole analyzer. Incorporation of an ion funnel trap ( IFT) into a triple quadrupole analyzer operating in the multiple reaction monitoring mode (MRM) resulted in 3 to 10 fold improvement in the limit of detection (LOD) as compared to the ion funnel interface and 20 to 50 fold LOD improvement in comparison to that of the commercial instrument. Rigorous studies of signal intensities of peptides added to a highly complex biological matrix at concentrations ranging from 0.5 nM to 1000 nM showed the linear response of the LC-IFT-MRM instrument with respect to the concentrations of low abundance peptides. Multiple Reaction Monitoring (MRM) offers a highly sensitive analytical platform to quantify trace constituents in complex biological matrices by selectively delivering analyte ions from an ESI source to an MS detector. Further sensitivity improvements with LC-MRM approach are achievable by enabling higher efficiency transport of analyte components from an ion source to the MS analyzer, eliminating dead times in analyses of fragment ions and reducing background ion signals. Electrodynamic ion funnel (IF) 1 or S-lense 2 have been shown to drastically improve MS sensitivity. A recently introduced ion funnel trap (IFT) has been demonstrated to further enhance the limit of detection for both the time-of-flight 3 and ion mobility time-of-flight mass spectrometers 4. The premise for sensitivity improvement with the IFT coupled to a triple quadrupole instrument is due to: i) ion accumulation in the RF-energized trap, which facilitates improved droplet desolvation manifested in the reduced background ion noise at the detector, ii) enhancement in signal amplitude for a given transition because of an order-of- magnitude increase in the ion charge density per unit time compared to the continuous mode of operation, and iii) the unity duty cycle in signal detection, as the use of the trap eliminates dead times between transitions, which are inevitable with continuous ion streams. This work reports on implementation of LC-IFT- MRM analysis of trace constituents from a complex biological matrix using a commercial triple quadrupole instrument (TSQ, Thermo Fisher Scientific). Chemicals and Materials: Lyophilized Kemptide, Angiotensin I, Syntide 2, Bradykinin, Leucine and Enkephalin, Dynorphin A Porcine 1-13, Neurotensin, and Fibrinopeptide A were purchased from Sigma-Aldrich (St. Louis, MO). These were serially diluted to prepare concentrations ranging from 0.25 nM to 500 nM in 0.25 mg/mL of tryptic digest of Shewanella oneidensis MR-1 proteins. Figure 1. Experimental setup and graphical interface of instrument control software for an ion funnel trap Figure 2. Pulsing sequence of experiment with the ion funnel trap. Ions are accumulated in the trap during dead time and dwell time followed by a 0.5 ms release event. Ion release event is synchronized with the start of Q3 scan. Parent Ions IonTrans.Frag.Trans.Frag.Trans.Frag.CE Kemptide (2+)409.27b 3 -NH a 5 -NH b 5 -NH 3 25 Angiotensin I (3+)534.27b4b a5a b5b5 21 Syntide (3+)283.18b3b y4y y Bradykinin (2+)522.27y NH y6y y7y7 30 Dynorphin A Porcine (3+) y NH y NH y NH328 Leucine Enkephalin (+)278.11b3b a4a b4b4 22 Neurotensin (3+)578.85y y y Fibrinopeptide A (2+)445.25y5y y7y y Electronics to control IF and IFT Source interface TSQ 4 column HPLC Timing pulse to synchronize trap release and Q3 scan Voltages to control trap Transition 1 Transition 2 Dead time Dead time Dead time accumulation eject Entrance grid Exit grid Transition 3 Q3 Trigger Exit grid Entrance grid ION FUNNEL TRAP Q1Q3 Collision cell Q2 Detector ION FUNNEL 10 torr1 torr 1.5x10 -3 torr multi inlet Kemptide fmoles loaded onto LC column Peak Area Angiotensin I fmoles loaded onto LC column Peak Area Leucine Enkephalin fmoles loaded onto LC column Peak Area fmoles loaded onto LC column Fibrinopeptide A Neurotensin fmoles loaded onto LC column Peak Area fmoles loaded onto LC column Bradykinin Peak Area Figure 3. LC-MS/MS experiment with a 0.25 mg/mL Shewanalla oneidensis digest spiked with nine peptides (see table 1). Inset shows three transitions of neurotensin acquired in continuous (blue trace) and trapping (red trace) modes SNR kemptide Leucine Enkephalin moles Figure 4. Signal-to-Noise (SNR) of kemptide and leucine enkephalin as a function of the peptide amount added to a 0.25 mg/mL Shewanella oneidensis digest in LC-MRM experiments. Bottom panels show selected ion chromatograms representing three transitions of the two peptides and the matrix signal in the corresponding m/z ranges. Table 1. List of peptides and the corresponding fragments monitored in LC- MRM experiments with a 0.25 mg/mL Shewanella oneidensis digest Figure 5. Comparison of the selected ion chromatograms corresponding to the three transitions of Angiotensin I added with other 8 peptides to a 0.25 mg/mL digest of Shewanella oneidensis in LC-MRM experiments. Trapping time in the IFT was 40 ms. Figure 6. Peak area as a function of the peptide amount for several peptides added to a 0.25 mg/mL Shewanella oneidensis digest in LC-IFT-MRM experiments.