Fundamentals and Applications of Flow Cytometry Scott Tighe Flow Cytometry Core Lab at the Vermont Cancer Center HSRF 305 656-2557.

Slides:



Advertisements
Similar presentations
Research Techniques Made Simple: Flow Cytometry Richard R
Advertisements

Absorption of photon elevates chromophore to excited state.
Fluorescence and Confocal Microscopy
1 2 3 * Flow = cells in motion * Cyto = cell * Metry = measure * Measuring properties of cells while in a fluid stream * Flow Sorting * Sorting (separating)
What is Flow Cytometry? Introduction to Flow Cytometry
Intro to Flow Cytometry James Marvin Director, Flow Cytometry Core Facility University of Utah Health Sciences Center Office Lab
Welcome IQAC at DHVI CD4 Immunophenotyping for HIV Monitoring Flow Cytometry.
Center of Excellence in Cancer Research Principles of flow cytometry
CHAPTER 37 MLAB 1415 HEMATOLOGY JOANNA ELLIS, MLS(ASCP) Optical Light Scatter and Flow Cytometry.
R. Hui Photonics for bio-imaging and bio- sensing Rongqing Hui Dept. Electrical Engineering & Computer Science, The University of Kansas, Lawrence Kansas.
Introduction To Flow Cytometry:
COMPENSATION By: Ronald Mathieu. Compensation Why do we need compensation? –1) Because of long emission spectrum of dyes like FITC and PE.
FLOW CYTOMETRY Dr. MOHAMMED H SAIEMA LDAHR KAAU FACULTY OF APPLIED MEDICAL SCIENCES MEDICAL TECHNOLOGY DEPT. 2 ND YEAR MT INSTROMINTATION EXT
FLOW CYTOMETRY Dr. MOHAMMED H SAIEMA LDAHR KAAU FACULTY OF APPLIED MEDICAL SCIENCES MEDICAL TECHNOLOGY DEPT. 2 ND YEAR MT INSTROMINTATION EXT
1 Visualization Tool for Flow Cytometry Data Standards Project Evgeny Maksakov CS533C Department of Computer Science, UBC in collaboration.
Overview What is flow cytometry? Development of flow cytometry Components of Flow Typical applications Flow data.
Flow Cytometry Basics James Marvin Director, Flow Cytometry Core Facility University of Utah Health Sciences Center Office Lab
FACSCalibur Training General Information The FACSCalibur is a useful analysis tool. The instrument has 2 lasers- 488 (primary) and 633 (secondary) that.
FLOW CYTOMETRY FACILITY
Basics of Flow Cytometry Holden Maecker. Outline Definitions, what can be measured by flow cytometry Fluidics: Sheath and sample streams, flow cells,
PPT 206 Instrumentation, Measurement and Control SEM 2 (2012/2013) Dr. Hayder Kh. Q. Ali 1.
FLOW CYTOMETRY AND CELL SORTING
Applications of flow cytometry in basic immunology Generation and characterization of DC Assays for T cell activation –Cell proliferation – Cell division.
FLOW CYTOMETRY Flow cytometry is a laser-based, biophysical technology employed in  cell counting,  cell sorting,  biomarker detection protein engineering.
Illumination and Filters Foundations of Microscopy Series Amanda Combs Advanced Instrumentation and Physics.
Flourescence Activated Cell Sorting
Practical molecular biology PD Dr. Alexei Gratchev Prof. Dr. Julia Kzhyshkowska Prof. Dr. Wolfgang Kaminski.
Cell viability studies Sepideh Khoshnevis. The Goal To distinguish live cells from dead and apoptotic cells in order to calculate the the percentage of.
Flow Cytometry at Boston University Medical Campus Introduction to some methods that we offer Yan Deng (X4-5225), Gerald Denis (X4-1371),
Introduction To Flow Cytometry By Noha Kamel. Flow cytometry is a method of measuring multiple physical and chemical characteristics of particles by optical.
Dr Gihan Gawish Hydrodynamic focusing is a technique used to provide more accurate results from flow cytometers or Coulter counters for determining the.
Basic Principles in Flow Cytometry
 Flow cytometry is a technique for counting, examining, and sorting microscopic particles suspended in a stream of fluid.
Basic Principles, Instrumentation, and Practices
Flow Cytometry Principles & practice of “Fluorescence Spectroscopy in Biological Diagnosis & Research” Dr.Hekmatimoghaddam Assistant professor of pathology.
Wavelength and Light Properties 575 nm  c  E = h  High Energy Low Energy.
FLOW CYTOMETRY  Definition: Measuring properties of cell as they flow in a fluid suspension across an illuminated light path.
Flow Cytometry Basic Training. What Is Flow Cytometry? Flow ~ cells in motion Cyto ~ cell Metry ~ measure Measuring properties of cells while in a fluid.
1 Flow Cytometry in the Clinical Laboratory Patricia Aoun, M.D., M. P. H. Jean Bailey, MT-ASCP Kellie Neth, MT-ASCP The Nebraska Medical Center.
2015 היחידה להפרדת תאים ד"ר דבי איצקוביץ'
Flow Cytometry Becton Dickinson Asia Limited Company.
FACS & Cell Sorting Cell Isolation
PBS 7413 FLOW CYTOMETRY LABORATORY. COURSE OBJECTIVES 1.UNDERSTAND CLINICAL AND RESEARCH APPLICATIONS OF FLOW CYTOMETRY TECHNOLOGY 2.PERFORM STAINING.
Quality Controls: Get your instruments under control!
Antigen-Antibody Interactions: Selected Tests (Contd.)
Flow Cytometry. Applications FRET- protein interaction Membrane protein expression Intracellular protein expression Cell viability Ca 2+
Multi-parameter Flow Cytometry: available dyes and combined usage Martin R. Goodier Department of Immunology Imperial College London.
Fluorescence and Fluorochromes Peter O’Toole Tel:
Dotplots CD3 CD4 Allow for visualizing relationship between two different parameters that is not apparent by histogram analysis.
Fluorescence and Fluorochromes Peter O’Toole Tel:
FACSCalibur Training General Information
Fluorescence 101 Steve Lee MiraiBio Inc. STR 2003.
بسم الله الرحمن الرحیم.
Flow Cytometry Halima Moncrieffe, University College London, UK IL-17
Flowcytometry.
Flow Cytometry FACS (Fluorescence-Activated Cell Sorter)
Flow Cytometry Basic Training
TRENDS IN LABORATORY TESTING
FLOWCYTOMETRY.
Laboratory Techniques in Immunology
Flow Cytometry and Sorting Part 1
Spectral Flow Cytometry
Some Basic Physics & Optics
Flow Cytometry and Sorting Part 3
Optical measurement.
Photon Physics ‘08/’09 Thijs Besseling
The Art of Flow Cytometry
Flow Cell Injector Tip Fluorescence signals Focused laser beam Sheath
Flow Cell Injector Tip Fluorescence signals Focused laser beam Sheath
Presentation transcript:

Fundamentals and Applications of Flow Cytometry Scott Tighe Flow Cytometry Core Lab at the Vermont Cancer Center HSRF

Overview Basics components of a cytometer Fundamentals of photonics-optics and fluorescence Software and modeling Types of analysis Sorting for cells and RNA Sample requirements- [controls, compensation, titer Ab, blocking] Sign-up for time on VCC instruments

What is Flow Cytometry? An instrument for making cell-based fluorescent measurements. Method for quantitating cellular or structural components of a cell using fluorescent antibodies or probes. Allows Analysis of tens of thousands of cells in minutes. A method to sort and collect specific cell types. The BD FACS ARIA with sorter Beckman Coulter Epics XL

Hardware Components of Flow Cytometer Fluidics - Cells are carried to laser in a saline-based sheath fluid. Pneumatics- Pressure drives the fluid flow Optics - laser, band-pass filters, and PMT detectors. Computer- Performs the analysis Older MoFlo cytometer by Cytomation

Fluidics Sheath Tank Waste Tank Line Pressure Vacuum Sample Pressure Sheath Pressure (Constant) THE FLOW CELL Laser focusing and hydrodynamic focusing LASER

Injector Tip Fluorescence signals Focused laser beam Sheath fluid The Flow cell: showing hydrodynamic focusing Higher the sample flow the wider the sample stream and lower the resolution

Excitation Sources

Lets consider two items The electromagnetic spectrum Fluorochrome excitation-emission curve

Lasers provide Coherent Light (Single mode-single wavelength) High Power Narrow band width Can be tunable or fixed wavelength Gas tube or Pumped solid state-which allows coverage for all fluorochromes! GASPSS Krypton-647nmNd-Yag (AlGaAs diode or Krypton lamp pumped) Argon -488nm Freq. Tripling !!! 1064,532,355nm HeNe [633nm]Great for Flow cytometry UV-364nm [from Ar]Ti:sapphire (Ar pumped) nm Excimers [ nm] Lasers This is just a few….

Output frequencies of common tunable gas tube lasers

Light Emitting Diodes [LED] -Benefits –Cheaper –Smaller –Easily Available –Many wavelengths -Cons -Not as bright -Broad excitation spectra -Not available for UV

Fluorescence and Photons

Fluorescence the molecular absorption of a photon triggers the emission of another photon with a longer wavelength. Release of Photon Stoke shift Ext. coef + Quantum yield is Quantum efficiency

The fluorochrome: Phycoerytherin Excitation 488 nm Emission Maximum 575 nm >20 chromophores per molecule High quantum yield (bright) 488 nm Argon 575 nm Large multi-subunit, globular (~240 kDa)

Optics and Detection

Laser (Argon 488nm) Red Signal FS Sensor Fluorescence detector (PMT1, PMT4 etc.) Detecting and sorting of different colors from cellular emission involves band pass filter and beam splitters Green Signal

Optics in a Flow Cytometer Beam Splitters

FS Sensor [size] Laser Forward Angle [FS] Light Scatter Provides data on size- The bigger the cell, the larger the FS

Side Scatter [SS] Detector Provides data on internal structures The more structures, the more ss Granulocytes have high ss Provides data on surface characteristics Dead cell have a rougher cell surface and a higher ss RBC have little to no ss FS Sensor SS Sensor [granularity] Laser

Beam Splitters Dichroic Filter/Mirror at 45 degrees Reflected light Transmitted Light Laser Light+ Sample Light nm BS nm and above reflected nm 500LP

Band Pass Filters Transmitted Light White Light Source 630/30nm BandPass Filter A 630/30 BPF will only allow nm through

Long Pass Filters Light Source 520 nm Long Pass Filter >520 nm Light Light Source 575 nm Short Pass Filter <575 nm Light Short Pass Filters Short Pass Filters Note: Great for microscopes

Detectors

Photomultiplier tubes (PMT) “Old” but good technology Most common detector used in flow High sensitivity but poor quantum efficiencies in red (>650nm) Able to adjust gain to over 100,000 Common Inexpensive Photodiode (PD) New[er] technology, still not common High quantum efficiencies for visible No internal gain adjustment Requires Cooling Require a high voltage bias

Flow cytometers may have 4 to 6 detector channels [or more] Flow cell PMT=Photomultiplier Tubes-do not see colors, only photons. PMT Dichroic filters Bandpass filter Laser PMT

Spectral Compensation Must be performed when using fluorochromes with overlapping emissions

Sorting Cells

The Cytomation Mo Flo cell sorter Analyzes and sorts cells at 70,000 cells per second Cost $ 350,000 

488 nm laser + - Charged Plates Single cells sorted into test tubes FS Sensor Fluorescence detector Sorting

Data Output

Histograms Data Output is represented by a histogram -Single parameter trace [one color] -Dual paramater dot plot [two color] Fluorescent intensity- 

Gating Allows the ability to select specific cell populations in one histogram and analyze for additional parameters [colors] in additional histograms

Comparison of single and dual parameter histograms

Specific Types of Analysis Done Using Flow Cytometry

Some Typical Applications of Flow Cytometry ? Immunophenotyping DNA cell cycle/tumor ploidy Membrane potential Ion flux Cell viability Karyotyping Cell tracking and proliferation Sorting Redox state Chromatin structure Cell proliferation assay Cell enumeration and sizing Apoptosis Phagocytosis Intracellular pH Intracellular calcium Oxidative burst Intracellular antigen measurement Cytokine detection Reticulocyte analysis Platelet analysis

Immunophenotyping

Immunophenotyping Classifying immune cells using cell surface antigens CD3 CD4 CD # = cluster designation number CD3-T-cell CD4-T helper

The structure of IgG-An Antibody Fab regions Fc receptor

Two Types of Antibody Labeling Direct labeling : Uses one antibody that has a fluorochrome conjugated directly on it. One step staining. Easier. Cell Indirect labeling : Uses two antibodies.The first is “against” a specific antigen on the cell. The second antibody is fluorochrome-labeled and is “against” the first. More complicated. Cell

Example of Data Using two mABs with dyes of different color outputs

Non-Specific Antigen Blocking Blocking is important to avoid false positives Non-specific binding of antibodies is really Fc binding Typically a serum source (BSA, FCS) is used but is often not adequate. Recommend goat IgG at ug/ml

mAB Titering-A must!!!! Uses a specific Number of cells against antibody dilutions. Perform on new lots of antibodies

Cell Cycle

Cell Cycle Analysis Indicates the rate and stage of cell replication or division. Propidium Iodide most common dye. The dye intercalates into the DNA strand. G2G2G2G2 M G0G0G0G0 G1G1G1G1 s CountCount NG1/G0 4NG2M S Phase (Synthesis)

Modeling Cell Cycle data When peaks are close together and overlapping, it is important to use specific software to model the data and get accurate results ModFit 3D 3.0 WinList 5.0 FloJo WinMDI is a free software written by J.Trotter and is available on the web.

Cell Cycle of GFP Cells

Cell Viability

Cell Viability Simplest method using cell permeabilization -Propidium Iodide -7AAD -Sytox Membrane potentials are a good indicator such mitochondria membrane potential [JC1]. Redox dyes-DHF, DHR- Turn colorless by reduction in cells. Enzyme activity probes-Esterase activity using cFDA, cell tracker dyes, calcein,… converted to fluorescent probe by enzymes.

How the assay works: PI cannot normally cross the cell membrane If the PI penetrates the cell membrane, it is assumed to be damaged Cells that are brightly fluorescent with the PI are damaged or dead PI PI PI PI PI PI PI PI PI PI PI PI PI PI Cell Viability using Dye Exclusion-Propidium Iodide Pi fluoresence >>> Dead Live

Apoptosis

Apoptosis-Annexin staining Uses Annexin-FITC against Phosphatidylserine to determine membrane translocation Uses PI to determine membrane permeability Must be used cautiously on adherent cells do to trypsin Not for fixed cells PI Annexin ApoptoticNecrotic

APO-BRDU-TUNEL DNA fragmentation Available 3’OH Uses Tdt to add BrDU Stain with anti-BrDU

Proliferation Assays

Proliferation can be measured by cell cycle, Brdu incorporation, and membrane dyes such as CFSE and PKH26. CFSE, PKH 26, Brdu incorporation to S-phase DNA

Sorting cells for RNA Decon the flow cytometer with bleach Run a test on dummy cells first check your viability Ensure all reagents are RNase-free Sort into an extraction buffer when applicable or sort into sterile media Extract RNA on the same day if in an extraction buffer *****Please come get a handout at our lab regarding these protocols

Sample requirements Negative no stain controls are required for most runs Single color controls are required for spectral compensation when performing two or more color analysis Samples should be in 12x75 plastic tubes containing 800ul of cell suspension at a concentration of 100,000-1 million cells Cells that are clumpy must be filter thru 70um mesh If using dual antibody staining, a secondary only will be necessary as well as your no stain control All analysis types should be accompanied with a positive control sample in order to validate the staining, protocol, and compensation

Logging into the VCC Flow cytometer Billing and sign up is done using the BioDesktop DNA facility>>>Shared Inst. Sign-up>>>Flow cytometer Reserve the time you plan to use it >>>OK Enter your contact info Enter your chartstrings into the chartstring manager You may edit after your run An will also be sent to you in case you need to edit your time for billing purposes Please sign up in the log-in book as well The new rate for the VCC flow is $9.51 [cancer] and [non-cancer] per ½ blocks

Thank you for your time