Wayne State University Indrin J. Chetty and Carri K. Glide-Hurst

Slides:



Advertisements
Similar presentations
Image Reconstruction.
Advertisements

Harvard Medical School Massachusetts General Hospital.
14th GEANT4 User and Collaboration Workshop - Catania, Oct. 15/ B.Caccia, G.Frustagli, M.Mattia, S.Valentini Istituto Superiore di Sanita' e INFN,
The Tomotherapy Experience at Advocate Good Samaritan Hospital
5 th September 2005 Paul Collins Computed Tomography Dosimetry Assessment of Effective Dose in Computed Tomography using an Anthropomorphic Phantom Paul.
Maria Skłodowska-Curie Memorial Cancer Centre and Institute of Oncology, Warsaw, Poland 8th ECMP, Athens, Dosimetry audits in radiotherapy.
IMAGE QUALITY NOISE LINEARITY CROSS-FIELD UNIFORMITY IMAGE ARTIFACTS.
The Use of Computed Tomography Images in Monte Carlo Treatment Planning Magdalena Bazalova PhD defense.
TREATMENT PLANNING PHOTONS & ELECTRONS Karen P. Doppke 3/20/2007.
1 Improved critical structure sparing with biologically based IMRT optimization X.Sharon Qi, Vladimir A. Semenenko and X. Allen Li Department of Radiation.
What is radiation therapy (RT)? Cancer treatment Tumor versus normal tissues External photon beam RT.
An algorithm for metal streaking artifact reduction in cone beam CT M. Bazalova 1,2, G. Landry 1, L. Beaulieu 3, F. Verhaegen 1,4 1-McGill University,
tomos = slice, graphein = to write
Tissue inhomogeneities in Monte Carlo treatment planning for proton therapy L. Beaulieu 1, M. Bazalova 2,3, C. Furstoss 4, F. Verhaegen 2,5 (1) Centre.
Introduction The effect of air-cavities within the human body, for example in the head and neck regions, present possible sources of error when calculating.
Introduction Modern radiation therapies such as intensity-modulated radiation therapy (IMRT) and volume modulated arc therapy (VMAT) demand from dose calculation.
Results The measured-to-predicted dose ratio criteria used by the RPC to credential institutions is , however for this work, a criteria of
11. – , Athens 8th European Conference on Medical Physics DOSIMETRY AUDITS IN RADIOTHERAPY IN THE CZECH REPUBLIC Irena Koniarová Daniela Ekendahl.
TWO FIELD BREAST PLAN VS. OPTIMIZED CONFORMAL BREAST PLAN: COMPARISON OF PLAN PARAMETERS Authors: Borko Basarić, Ozren Čudić, Milan Teodorović, Borislava.
Shannon M MacDonald 1, Salahuddin Ahmad 2, Stefanos Kachris 3, Betty J Vogds 2, Melissa DeRouen 3, Alicia E Gitttleman 3, Keith DeWyngaert 3, Maria T Vlachaki.
Evaluation of New Pre-Treatment In-Air Patient Specific QA Software for TomoTherapy Treatments Lydia L. Handsfield¹, Quan Chen¹, Kai Ding¹, Wendel Renner²,
Measurement of Dose to Critical Structures Surrounding the Prostate from Intensity-Modulated Radiation Therapy (IMRT) and Three Dimensional Conformal Radiation.
H Ariyaratne1,2, H Chesham2, J Pettingell2, K Sikora2, R Alonzi1,2
Patient Plan Results: Table 3 shows the ratio of the Pinnacle TPS calculation to the DPM recalculation for the mean dose from selected regions of interest.
Test of the proposed method Introduction CCD Controller CCD Illuminator gel Filter 585nm Assembling the phantom before its irradiation. The phantom, ready.
In vivo dosimetry Eirik Malinen Eva Stabell Bergstrand Dag Rune Olsen.
Region of Interest Analysis as a Tool for Exploring Adaptive IMRT Strategy for Cervix Cancer Patients Young-Bin Cho 1,2, Valerie Kelly 1, Karen Lim 1,2,
MRI SIMULATION FOR CONFORMAL RADIATION THERAPY OF PROSTATE CANCER Pasquier D 1-3, Palos G 3, Castelain B 1, Lartigau E 1,2, Rousseau J 2,3 1 Department.
Medical Image Analysis Image Reconstruction Figures come from the textbook: Medical Image Analysis, by Atam P. Dhawan, IEEE Press, 2003.
Application of a 2-D ionization chamber array for dose verification of dynamic IMRT with a micro-MLC Fujio ARAKI, PhD 1, S. TAJIRI 2, H. TOMINAGA 2, K.
The Radiological Physics Center’s Anthropomorphic Quality Assurance Phantom Program Carrie F. Amador, Nadia Hernandez, Andrea Molineu, Paola Alvarez, and.
1 A Comprehensive Study on the Heterogeneity Dose Calculation Accuracy in IMRT using an Anthropomorphic Thorax Phantom S Davidson 1, R Popple 2, G Ibbott.
TPS & Simulations within PARTNER D. Bertrand, D. Prieels Valencia, SPAIN 19 JUNE 2009.
IRCC & Mauriziano Hospital & INFN & S Croce e Carle Hospital
Part No...., Module No....Lesson No
Quality Assurance.
P. Rodrigues, A. Trindade, L.Peralta, J. Varela GEANT4 Medical Applications at LIP GEANT4 Workshop, September – 4 October LIP – Lisbon.
Optimization of Volumetric Modulated Arc Therapy (VMAT) Planning Strategy Using Ring-shaped ROI for Localized Prostate cancer Kentaro Ishii, Masako Hosono,
Flair development for the MC TPS Wioletta Kozłowska CERN / Medical University of Vienna.
Purpose N-isopropylacrylamide (NIPAM) polymer gel dosimeters were employed to verify the dose distribution of clinical intensity modulated radiation therapy.
第三讲: Basic treatment planning - Dengsong Zhu, MS, DABR Medical Physicist Radiation Safety Officer.
The Effects of Small Field Dosimetry on the Biological Models Used In Evaluating IMRT Dose Distributions Gene Cardarelli,PhD, MPH.
Cone Beam CT at the Ghent University Hospital: first clinical results and evaluation of the selected workflow. G. Pittomvils 1,,M. Coghe 1, A. Impens 1,
MCS overview in radiation therapy
Sunday Case of the Day How does the presence of the object impact patient dose? A. Increases by 20% - 50% B. Increases by 3% - 5% C. No Change D. Decreases.
A comparison between soft tissue and bone registration techniques for prostate radiotherapy Richard Small, Paul Bartley, Audrey Ogilvie, Nick West and.
Grand Valley State University
Characterization of proton-activated implantable markers for proton range verification using PET J. Cho1, G. Ibbott1, M. Kerr1, R. A. Amos2, F. Stingo1,
J Cho, G Ibbott, M Kerr, R Amos, and O Mawlawi
2013 Annual Scientific Meeting of the SSRMP
New Hybrid Monochromatic CT Images Achieve High Suppression of Metallic Artifacts While Preserving Soft Tissue and Iodine Contrast Michal Kulon, Peter.
Hsiao-Ju Fu Yuk-Wah Tsang Chih-Chia Chang
Evaluation of mA Switching Method with Penalized Weighted Least-Square Noise Reduction for Low-dose CT Yunjeong Lee, Hyekyun Chung, and Seungryong Cho.
The use of 4DCT images to optimize the Internal Target Volume in Radiotherapy  Nikos Giakoumakis, Brian Winey, Joseph Killoran, Tania Lingos, Laurence.
Introduction Materials & Methods Results Conclusion
Evaluation Of RTOG Guidelines For Monte Carlo Based Lung SBRT Planning
Evaluation of the AAA Treatment Planning Algorithm for SBRT Lung Treatment: Comparison with Monte Carlo and Homogeneous Pencil Beam Dose Calculations 
A Brachytherapy Treatment Planning Software Based on Monte Carlo Simulations and Artificial Neural Network Algorithm Amir Moghadam.
Implementation of Object Spot Avoidance in Proton Pencil Beam Treatment on Whole Breast with Implant Metal Injector Peng Wang, PhD, DABR, Karla Leach,
Insert tables Insert figure
Volumetric Modulated Arc Therapy (VMAT) versus Intensity Modulated Radiation Therapy (IMRT) for Anal Carcinoma Heather Ortega, BSRT(T), CMD, Kerry Hibbitts,
Conformal Photon-Beam Radiotherapy of Prostate Carcinoma
Insert tables Insert graphs Insert figure
Applications of Dual-Energy Computed Tomography for the Evaluation of Head and Neck Squamous Cell Carcinoma  Reza Forghani, MD, PhD, Hillary R. Kelly,
A Multi-Institutional Dosimetric Evaluation of Proton Versus Photon Stereotactic Body Radiation Therapy for Hepatocellular Carcinoma F. Khan, B. Nguyen,
Goals Significance Results Uncorrected MAR Corrected
Physics and Imaging in Radiation Oncology
P. Rodrigues, A. Trindade, L.Peralta, J. Varela
Thursday Case of the Day
GHG meeting at ESTRO36 May, 2017
Presentation transcript:

Wayne State University Indrin J. Chetty and Carri K. Glide-Hurst Impact of Metal Artifact Reduction (MAR) in Treatment Planning: Comparison of Dose Calculation Algorithms Daiquan Chen Wayne State University Indrin J. Chetty and Carri K. Glide-Hurst Henry Ford Hospital

Disclosures Henry Ford Health Systems holds research and beta testing agreements with Philips Medical Systems. Previous work by our group suggests that substantial delineation differences can be revealed by MAR. These can lead to significant dosimetric effects. However, it is not known if it is “safe” to use these images for delineation AND dose calculation. Furthermore, it is not known what dose calculation algorithms will be sensitive to MAR corrected CT datasets. This study will determine this.

Motivation: Metal Artifact Metal in patient: Dental filling, surgical clips, hip prosthesis, rods, etc. Leads to: Beam hardening, scatter, noise, absence of information (photon starvation)

Metal Artifact Reduction = Delineation Differences ORIGINAL ARTIFACT CORRECTED RECTUM BLADDER SEMINAL VESICLES PROSTATE Previous work by our group suggests that substantial delineation differences can be revealed by MAR. These can lead to significant dosimetric effects. However, it is not known if it is “safe” to use these images for delineation AND dose calculation. Furthermore, it is not known what dose calculation algorithms will be sensitive to MAR corrected CT datasets. This study will determine this.

AAA and Pencil Beam Convolution (PBC) in Eclipse PURPOSE To systematically evaluate the dosimetric impact of metal artifact reduction (MAR) algorithm both in phantom and patient using four clinically commissioned treatment planning algorithms: AAA and Pencil Beam Convolution (PBC) in Eclipse Monte Carlo (MC, Dmed, Dwater) and PBC in Brainlab With and without heterogeneity correction (HC)

Materials CIRS Model 002LFC IMRT Thorax Phantom with lung, soft tissue, bone and metal insertions Philips Big Bore Scanner Extended Brilliance Workspace (EBW) 3.5 with research interface (Philips Healthcare, Cleveland, OH) MAR applied to reconstructed images using compiled Matlab program (v7.8) integrated into EBW platform Eclipse External Beam Treatment Planning System (v8.6) Brainlab iplannet Treatment Planning System (RT Dose 4.1.2, RT Image 4.1.2 and PatXfer RT) ImageJ 1.43u with DICOM importer/exporter Auxiliary dose value-preserve program for ImageJ

METAL INTERPOLATED IMAGE MAR Algorithm INPUT SINOGRAM ORIGINAL INPUT IMAGE FORWARD PROJECT MASKED SINOGRAM ERROR SINOGRAM THRESHOLD METAL SINOGRAM METAL-ONLY IMAGE INPUT ─ CLASSIFIED ERROR MASKED BY METAL METAL INTERPOLATED IMAGE CLASSIFIED SINOGRAM FILTERED BACKPROJECTION CORRECTION IMAGE TISSUE CLASSIFICATION ADD TO INTERPOLATED INPUT IMAGE

Simplified Work Flow

Treatment Planning Considerations 6 MV photon beam (Novalis) Same treatment plan for all algorithms in each case Same PTV and other structures for corrected and uncorrected cases Same Dose Matrix dimension Same Region of Interest (ROI) for statistics by developing a Macro in ImageJ Dose matrix alignment between Eclipse & Brainlab addressed

Phantom CT Data Acquisition and Configurations Insertions: a. Lung; b. Soft Tissue; c. Bone; d. Metal (Cerrobend) Single Metal Rod cases: (b), (c), (d). Single 9.8 x 9.8 beam set up. Double Metal Rod cases: (e), (f), (g). Two opposed 9.8 x 9.8 beam set up. Prescribed dose: 2Gy to PTV (metal)

Patient Data Femur: Two 3D conformal beam plan. Prescribed dose 2.0 Gy/fraction, 11 fractions Humerus: Two 3D conformal beam plan. Prescribed dose 2.5 Gy/fraction, 7 fractions Head & Neck: Seven beam IMRT plan. Prescribed dose 2.0 Gy/fraction, 25 fractions Prostate: Nine beam IMRTplan. Prescribed dose 1.8 Gy/fraction, 30 fractions

Results: Recovered CT Number and Dose, Phantom Results of algorithm MC_HC, statistics from (f) was considered to be “truth” and compared with results of other algorithms. Legends indicated CT number and dose in Gy for the top and bottom, respectively.

Results: Recovered CT Number and Dose, Patient (f) Results of algorithm MC_HC, prostate case, IMRT plan, statistics from circled area of (f) were compared with results of other algorithms. Legends indicated CT number and dose in Gy for the top and bottom, respectively.

Results: Recovered CT Number and Dose, Patient Results of algorithms AAA (b, e) and MC_HC (c, f), Femur and Humerus cases, 3D conformal plan. Legends indicated CT number and dose in Gy for the left and right, respectively.

Phantom Results: Single Metal Rod %dose discrepancy = (Mean MAR dose - mean uncorrected) / RX dose Algorithms (HC on) AAA Mean ± Stdev (cGy) Range (cGy) PBC_Eclipse PBC_Brainlab MC_Dmed Tissue, Metal, Lung -0.8 ± 1.7 (-0.4%) -4.5 to 3.9 -0.5 ± 0.7 (-0.25%) -2.5 to 1.5 0.2 ± 0.2 (0.1%) -3.5 to 3.4 1.4 ± 3.8 (0.7%) -10.7 to 13.8 Tissue, Metal, Bone 1.8 ± 2.2 (0.9%) -7.7 to 6.9 -2.1 ± 1.5 (-1.05%) -5.3 to 0.3 -3.6 ± 2.6 (-1.8%) -10.4 to 1.4 -1.5 ± 4.7 (-0.75%) -14.7 to 8.4 Lung, Metal 3.1 ± 2.0 (1.05%) -2.9 to 8.3 2.9 ± 2.0 (1.45%) -2.2 to 6.6 3.0 ± 2.4 (1.5%) -3.1 to 7.6 -0.3 ± 3.6 (0.15%) -11.1 to 12.2

Phantom Results: Double Metal Rod %dose discrepancy = (Mean MAR dose - mean uncorrected) / RX dose Algorithms (HC on) AAA Mean ± Stdev (cGy) Range (cGy) PBC_Eclipse PBC_Brainlab MC_Dmed MC_Dwater Tissue, Metal, Bone (Fig. 1e) -12.3 ± 5.7 (-6.15%) -23.4 to 4.0 -1.4 ± 2.3 (-0.7%) -9.2 to 2.9 0.5 ± 3.1 (0.25%) -9.0 to 6.8 -5.1 ± 4.5 (-2.55%) -19.9 to 5.4 -10.8 ± 5.7 (-5.4%) -28.2 to 6.2 Lung, Metal, Bone (Fig. 1f) -5.7 ± 3.5 (-2.85%) -12.8 to 5.2 -0.8 ± 1.1 (-0.4%) -3.0 to 1.6 0 ± 1.5 (0%) -2.8 to 3.5 -9.1 ± 4.3 (-4.55%) -22.1 to 5.5 0.4 ± 4.8 (0.2%) -14.4 to 17.4 Bilateral Lung, Metal (Fig. 1g) 0 ± 4.4 -9.5 to 15.3 -11.7 to 11.7 -24.2 ± 4.5 (-12.1%) -31.7 to -14.7 -36.2 ± 6.2 (-18.1%) -52.7 to -22.6 1.4 ± 4.8 (0.7%) -12.2 to 13.5

Results: Patient Data %dose discrepancy = (Mean MAR dose - mean uncorrected) / RX dose Algorithms (HC on) AAA Mean ± Stdev (%) Range (cGy) PBC_Eclipse PBC_Brainlab MC_Dmed Femur (3D) -0.42±0.42 -31.2 to 12.9 0.08±0.21 -8.0 to 11.8 0.10±0.22 -5.6 to 15.6 0.70±1.35 -72.0 to 98.2 Humerus (3D) 0.34±3.41 -17.3 to 702.4 0.17±0.41 -53.7 to 36.6 7.94±23.95 -21.1 to 1803.9 6.97±24.15 -65.2 to 1804.9 Head & Neck (IMRT) 0.00±0.00 -0.2 to 0.3 0.07±0.28 -80.0 to 50.0 0.39±3.92 -96.3 to 3149.5 -0.42±4.36 -373.8 to 3141.7 Prostate (IMRT) 8.37±22.97 -79.5 to 5625.3 0.12±0.16 -39.3 to 15.8 11.01±31.21 -4698.5 to 5698.3 12.32±30.95 -4541.3 to 5725.3

Bilateral Hip Patient: DVHs (c) (d) (e) (f)

Discussion: MAR Dosimetric differences revealed between original and MAR corrected CT scans can be substantial. For double rod phantom cases in a series of configurations, the maximum dose difference observed was 52.7 cGy for 200 cGy RX (26.4% diff) for MC_Dmed. For the 3D planning patient cases, beams traversed directly through the metal rods, up to 8 +/- 24% mean dose differences were observed. For bilateral hip implant cases, significant underdosing observed between the metal implants (max difference = 106%) for MC_Dmed. This suggests caution should be exercised when using original CT scans to calculate dose, as significant underdosing can occur. In clinical practice, some clinics will combat this by overriding density in this region with a uniform value. Even if mean dose differences between MAR corrected and uncorrected cases are small, significant hot/cold spots (local regions) are observed when CT to electron density table equates MAR-affected regions to density near air.

Discussion: Algorithms PBC_Eclipse was the least sensitive dose calculation algorithm to the CT signal recovered with MAR, yielding dosimetric differences <1% for all cases studied. Brainlab algorithms (PBC and MC_Dmed) yielded largest dose discrepancies for all cases, and appeared most sensitive to MAR correction When HC is disabled (results not shown), negligible dose differences were observed. This suggests that clinical solutions that disable HC for metal implants may not directly benefit from MAR unless their clinical practices change. Compared with AAA, PBC in Brainlab was more sensitive. This may be attributed to to adaptive grid size for small heterogeneity in the PBC-Brainlab algorithm.

Conclusions Variety of material configurations (minor to very severe metal artifacts), interface effects, and the impact of different materials on the surrounding dose distribution were evaluated Systematic evaluation of 4 different dose calculation algorithms in 2 TPS These results can be used to facilitate the implementation of MAR corrected images in treatment planning

Acknowledgments Dr. Carri Glide-Hurst Dr. Indrin J. Chetty, Dr. Teamour Nurushev Dr. Jinkoo Kim, Dr. Winston Wen, Dr. Lei Ren, Dr. Haisen Li Correen Fraser, Anne Reding, Zeina Alawieh, Kate Aldridge