Sharp HealthCare Safety Training 2015 Module 3, Lesson 2 Always Events: Line and Tube Reconciliation and Guardrails Use Our vision is to create a culture.

Slides:



Advertisements
Similar presentations
Your Class Jeopardy Your Name Topic Life Earth Space Grab Bag II Physical.
Advertisements

Sometimes you just have to let someone else do it!
Intravenous Drug Administration
An Imperative for Performance Improvement
PERIPHERAL INTRAVENOUS LINE MAINTENANCE for the Indiana EMT-B
Medication Administration
Patient Safety What is it? Why is it important? What are we doing? What is my part to play?
Sharp HealthCare Safety Training 2015 Module 3, Lesson 3: Always Event: Safe, Reliable Patient Identification Our vision is to create a culture where patients.
McKesson Upgrade - ER 11/12 What is ER 11/12? October, 2013
Principle Concepts of Iv therapy.
June 28, 2004 Mark Duffett Leslie Gauthier The Medley ® Pathway to Patient Safety.
Breakout Session: Preventing Enteral Misconnections Michelle Kozeniecki, MS, RD, CNSC Clinical Dietitian, Froedtert Hospital WiSPEN 2014 Fall Symposium.
Standard 5: Patient Identification and Procedure Matching Nicola Dunbar, Accrediting Agencies Surveyor Workshop, 10 July 2012.
Amsino Your Medical Device Partner
1 High 5s Project for Patient Safety: What is the Role for IHF? In support of the work of WHO Patient Safety Programme Karen H. Timmons.
Recommended by the Sentinel Event Alert Advisory Group NATIONAL PATIENT SAFETY GOALS FY 2009.
NORTH AMERICAN SAFETY CHECKLIST – SB 158. Rhonda Anderson, RHIA President Anderson Health Information Systems, Inc. Presented By:
Safe Enteral Connection – ISO Standard Changes
JCAHO UPDATE June The Bureau of Primary Health Care is continuing to encourage Community Health Centers to be JCAHO accredited. JCAHO’s new focus.
1955 when Codman who is also known as father of Patient safety looked at the outcome of patient care 1984 Anaesthesia patient safety foundation established.
Department of Quality and Regulatory Affairs Barbara Ann Karmanos Cancer Center 2009 The Karmanos Cancer Center Quality, Patient Safety, and Performance.
Module Two Medication Administration. Medication Administration In the School Setting.
The Disposable Infusion Pump Instruction Basal + PCA Bolus Model.
Definition:  medication that have a higher likelihood of causing injury if they are misused. Errors with these medications are not necessarily more frequent-
National Patient Safety Goals 2011
Preventing Surgical Complications Prevent Harm from High Alert Medication- Anticoagulants in Primary Care Insert Date here Presenter:
Occurrence Reports. An occurrence report is a document used to record an event when it occurs Occurrences are reported each time an occurrence occurs.
Registry Skills Review Compiled and presented by IHCC EHS 1999 paramedic students: Matt Nielson Mary Sticha Kerstin Buettner Krista Hornish Kevin Harty.
Managing Hospital Safety: Common Safety Concerns (Hospital-focused presentation) Part 3 of 4.
N26: IVPB Spring 2012 Terminology
| |
Medication Use Process Part One, Lecture # 5 PHCL 498 Amar Hijazi, Majed Alameel, Mona AlMehaid.
Copyright © 2012 Wolters Kluwer Health | Lippincott Williams & Wilkins Chapter 10Safety Concerns in Healthcare.
| |
AJ5808/5808A INFUSION PUMP QUICK OPERATION GUIDE.
Principles of Medication Administration and Medication Safety Chapter 7 Mosby items and derived items © 2010, 2007, 2004 by Mosby, Inc., an affiliate of.
Quarterly Medication Error Data April Quarterly Error Report - Review Medication Error data based upon Safety Reports No report = No data Greater.
FMEA: 20/20 Foresight Deirdre, RN; Kim, RN Juliana; Marija Deirdre, RN; Kim, RN Juliana; Marija.
Common Venipuncture Sites Dose Calculators Insertion of Peripheral IV Catheter Insertion of a Central Line Catheter Methods of IV Medication Administrations.
Occurrence Reports. An occurrence report is a document used to record an event when it occurs Occurrences are reported each time an occurrence occurs.
Preventing Errors in Medicine
| |
Intravenous Administration Nurses administer meds IV in the following ways: – As mixtures within large volumes of IV fluids (Banana bag) – By injection.
National Patient Safety Goals 2008 T he University of Toledo Medical Center Toledo, Ohio.
| |
Informatics Technologies for Patient Safety Presented by Moira Jean Healey.
ENFit™ Your Clear Connection to Enteral Safety CORPAK MEDSYSTEMS With over 35 years leadership, specialising in design and innovation to deliver unique.
Calculation of Basic IV Drip Rates
Copyright © 2010 Delmar, Cengage Learning. ALL RIGHTS RESERVED. Chapter 15 Introduction to IV Therapy.
ADVERSE DRUG EVENT (ADE) Driver Diagram OHA HEN 2.0.
Storage, Labeling, Controlled Medications Guidance Training CFR § (b)(2)(3)(d)(e) F431.
Chapter 31 Medication Administration. Injections: Intravenous  Three methods:  As mixtures within large volumes of IV fluids  By injection of a bolus.
Smart Pump Wireless Technology: An IQ Boost for the Pump
Laura Kirk, MD Benjamin Reynolds, MD Jason Papazian, MD
Established Status Epilepticus Treatment Trial (ESETT)
Development Policies and Procedures Manual
Infusion Pump ROP Compliance
2.13 Copyright UKCS #
Improve the Safety of Using Medications
Clinical Alarm Systems - NPSG Goal # 6 -
BD CATO™ Medication Workflow Solutions
IV Tubing and Tubing Labeling: Trace the Lines!!
ايمني بيمار PATIENT SAFETY حق بيمار و مسئوليت ما
Alaris® Auto-ID & Hand-Held Scanners
8 Medication Errors and Prevention.
Documenting on Override Pulls
Introduction to IV Therapy
Presentation transcript:

Sharp HealthCare Safety Training 2015 Module 3, Lesson 2 Always Events: Line and Tube Reconciliation and Guardrails Use Our vision is to create a culture where patients and those who care for them are free from harm. National Patient Safety Foundation (NPSF)

Learning Objectives Identify the importance of following standard processes to provide safe, highly reliable care. Discuss the elements required in the standard process for line reconciliation. Describe the importance of the new ENFit enteral system connectors to preventing dangerous misconnections. State when Alaris Guardrails should be used. Commit to performing these safe practices for every patient, every time.

Sharp’s Key Safety Programs, Skills and Tools Just Culture Workforce Competence / Orientation / Annual Competency Programs TeamSTEPPS Patient and Care Partner Engagement Programs Learning and Reporting Systems to Identify Risks: RL Solutions Medication Safety Programs and Tools Always Events Program and Tools Lean Six Sigma (Robust Process Improvement) Change Acceleration Process (CAP) Tools Safe Use of Technology Tools Environmental Safety Programs

Always Events…Every Patient, Every Time Sharp HealthCare has identified 7 critical patient safety practices that we expect to happen for every patient, every time. Our goal is to be a high reliability organization that habitually performs these 7 practices, which we refer to as Always Events. This module addresses Line Reconciliation and Guardrails Use. Patient Identification Treatment/Procedure Verification Six rights of medication administration Alaris® Guardrails® Line Reconciliation Universal Protocol Hand Hygiene

Infusion Errors IV Infusion errors have occurred at every Sharp entity. These errors, harmful or not, are considered serious events because of their potential to cause patient harm. Through review of our adverse events and near misses several common themes emerged: Errors occurred with hanging the correct solution/medication Errors occurred during pump programming Error occurred in connection of the line

Infusion Errors Examples include: A laboring patient was bolused with pitocin instead of LR A 20mEq KCl IVPB was infused wide-open because it was connected to a port below the pump rather than above it A wrong dose of chemotherapy was administered because an incorrect weight was entered on the patient Neosynephrine was changed from single-strength to double-strength, but the Alaris pump was not reprogrammed accordingly, delivering twice the intended dose

Dangerous Misconnection Errors Examples include: An epidural set was inadvertently connected to IV tubing, resulting in patient death A non-invasive automatic B/P cuff tubing was erroneously connected to a saline-locked IV port by a family member after the patient ambulated to the bathroom. The patient received a fatal air embolism and died. An night shift RN inadvertently connected a small bore feeding tube to a central line port. The RN did not want to turn on the light to awaken the patient, and the line and tube were in next to one another. The patient died as a result of this error. These errors are enabled because the connectors for many lines and tubes are compatible, enabling potentially deadly misconnections. Incompatible connectors would have prevented these errors.

The Solution: Standard Work Standard work is a written description of the safest, highest quality, and most efficient way to perform a process or task* and benefits include: Clearly defines specific steps Captures best, safest practice Reduces variation Increases consistency Applies to all settings Easy to recognize deviation from the norm Allows for cross-monitoring A Standard process for performing Line Reconciliation has been established, which includes the following 3 steps. *Adapted from The Lean Handbook

Line Reconciliation: It’s for More Than IVs What Needs to be Reconciled? All solutions being administered to the patient through a line or tube. This includes, but is not limited to: IV drips, IVPB, IV Fluids, IV Contrast PCA Epidural Bladder/Rectal Medication Instillation Tube Feedings Peripheral Nerve Blocks It is important to reconcile ALL lines and tubes to prevent a potentially harmful tubing misconnection. A dangerous misconnection is enabled because many medical lines and tubes have a luer connection, enabling tubes and lines to be accidentally connected.

ENFit: Enteral System Design Changes are Coming! International standards for unique connectors are being developed to prevent the potential for deadly misconnections. The first standards are for Enteral Systems, which we will begin to implement in early 2015. Look for information as to when products with these new connectors will be coming to your site. Until then, we must rely on human vigilance to prevent these errors.

Line and Tubing Tracing Trace ALL tubes and lines from the patient to the point of origin: before connecting or reconnecting any device or infusion at any transition, such as to a new setting or service as part of the hand-off process The process for reconciling IV lines is more specifically defined in the next several slides.

Line Reconciliation Process: When to Perform Line Reconciliation is performed when: Starting an infusion Replacing an empty infusion (bag, syringe, etc.) Changing concentration (e.g. single to double strength) Receiving a patient from another care area Patient is not responding to treatment as expected There is uncertainty about any element of the process Jointly during any RN-RN handoff (not for breaks) Note: Side by side & independent verification are still required on select high-risk medications.

Line Reconciliation Standard Work Step 1 Using your hand, physically trace the line from the solution through the pump, ensuring correct cartridge placement, on down to the patient. B. Verify fluids, medications & blood and enteral products against the order (e.g. IV drip, IVPB, IV fluid, PCA, Epidural, enteral) Name of infusion/ medication Concentration Dose / rate

Examples of Risk When Medications / Fluids are Not Verified Correctly Example #1: A wrong medication was hung because the RN did not verify the bag that the pharmacy tech delivered to the RN before it was hung. The infusion that was delivered was not the expected infusion, but rather a medication for a patient who was previously in the room but had transferred out of the unit. Example #2: D5.45NS was hung instead of D5.9NS because the IV bag had been mis-stocked in the wrong box.

Line Reconciliation Standard Work Step 2 Verify correct pump settings Correct profile on Alaris® pumps Med/ fluid Guardrail selection (Guardrails are required for all fluids run on an Alaris pump) Concentration Patient weight for weight-based medications Dose/ rate

Examples of Risk When the Pump Programming is Not Verified Example #1: Milrinone was programmed at twice the ordered rate because the RN assumed that the concentration was single-strength rather than double-strength. Example #2: A double dose of magnesium was administered due to an error in pump programming that was not detected.

Line Reconciliation Process Step 3 Verify that the connection is secured to the correct port. Perform this process for each infusion, even those run on pumps other than Alaris.

Examples of Risk When the Connection is Not Confirmed A cardizem infusion was properly programmed and started but not delivered because the RN did not connect the infusion to the patient. A pre-op antibiotic was not delivered to the patient because the clamp was not opened. An infusion can be connected to the wrong line, resulting in a dangerous misconnection, such as connecting an epidural to an IV line.

Use of Alaris Guardrails Alaris® pumps support patient safety through: Standardized drug libraries Standardized profiles for different care levels “Soft” and “Hard” stop alerts Using Guardrails for every patient, every time for solutions that are run on Alaris pumps, even for fluids without additives (e.g. NS, LR), reduces errors in pump programming.

Use Guardrails for Every Infusion, Every Time Why is it necessary to use Guardrails with IV fluids? How does it improve safety? Using Guardrails for every infusion run on an Alaris pump allows the practice to be hardwired. It takes the guess work out of deciding if an infusion requires Guardrails or if it doesn’t. It allows units that use medication infusions infrequently to become comfortable with using Guardrails.

Example of Risk Created When Guardrails are Not Used A patient received a larger dose than ordered of heparin because of an error in the rate of the infusion. The error was not caught because the infusion was not programmed using Alaris® Guardrails.

Summary Line / Tube Reconciliation is a process that requires: Placing your hand on each infusion and physically tracing the line from the solution, through the pump and into the patient. (it is a tactile and visual process) Reconciling the accuracy of the solution and pump settings against a primary source (e.g. MAR, order). Verify fluids, meds & blood and enteral products against order Verify correct pump settings Verify the connection is secured to the correct route Line Reconciliation and Guardrails are Always Events, …every patient, every time!