CodeDataPlate.com. New in 2007 edition and in a-2008 2.7.5.2.1 MRL Pit Signage 3.18.6 Marking of HY Jack 8.10.2.2.2 Governor 8.10.4.1 Escalator Governor.

Slides:



Advertisements
Similar presentations
Ohio Code Data Plates Past 8 Months Orders from Elevator Companies –Many are ordering Standards in quantity –A few only give State ID Slows process as.
Advertisements

Tower Crane Safety Regulations
Stakeholders Meeting June 22, 2011 Division of Building Safety Industrial Safety Elevator Program.
Means of Vertical Circulation: Elevators traction verse hydraulic types, sizes, speeds and finishes, escalators. Hydraulic Elevators Traction Elevators.
F&T Inc. OVERHEAD CRANE SAFETY.
Technology in Architecture
What to look for, What to correct, How it should look,
2015 Update to OBC September 17, 2014.
Postal Responsibility/Contractor responsibility 1.Serial number of fire extinguisher 2.Number found on fire extinguisher and panel 3.Date extinguisher.
Ted “Smitty” Smith  I have included in the following slides some key sections from each of the codes you will primarily encounter on the test. I recommend.
2.5.2 Student Book © 2004 Propane Education & Research CouncilPage Examining, Maintaining and Operating ASME Tank Setting Trailers For the safe.
National Electrical Code codified by Massachusetts 2011 edition Always consult with the Inspector of Wires (AHJ) for his or her interpretation of the Code….
FHM TRAINING TOOLS This training presentation is part of FHM’s commitment to creating and keeping safe workplaces. Be sure to check out all the training.
Conveying Systems.
Michigan Department of Licensing and Regulatory Affairs Bureau of Construction Codes.
Elevators & Fire Alarm Systems: Understanding Interface Requirements Presented by: Antonio Torres- North Central Regional Sales Manager.
Ron DeJuliis, Commissioner of Labor and Industry Rob McGeeney, Program Manager Larry Kreseski, Chief inspector Department of Labor, Licensing, and Regulation.
Copyright  Business & Legal Reports, Inc. BLR’s Safety Training Presentations Cranes and Slings 29 CFR and 184.
Crane and Hoist Training
Cranes, Derricks, Hoists, Elevators, & Conveyors for Construction
ELEVATORS Environmental Technology IV - Professor Tango & Parker - Spring 2009.
Cranes, Derricks, Hoists, Elevators, & Conveyors for Construction.
AGENDA INTRODUCTION CELLS AND COMPONENTS PV PERFORMANCE PV APPLICATIONS CODES AND STANDARDS EMERGENCY RESPONSE.
Suntraders Company Ltd. / Anthony Kent Gibbons Industrial Park, Christ Church, Barbados BB17101 (246) Fax: (246)
Machines used in Forest Activities Section H of the Logging Code.
The Federal Railroad Administration (FRA) is an agency that belongs to the United States Department of Transportation. The agency was created by the Department.
1/11/11 4/17/
2.5.3 Student Book © 2004 Propane Education & Research CouncilPage Verifying Proper ASME Tank Condition Prior to Loading For the safe and efficient.
NFPA 31 Standard for the installation of Oil- Burning Equipment
MECHANICAL EQUIPMENTS OF BUILDING (Vertical Transportation) ELEVATORS – hoisting mechanism Two Types: Electric & Hydraulic Electric E. – tall buildings/DC.
Georgia Tech Safety and Health Consultation Program
Cranes and Slings 29 CFR and 184
7/25/12www.CodeDataPlate.com1. 7/25/12www.CodeDataPlate.com2 Disclaimer The opinions and recommendations presented here are strictly my own and are not.
Section 703 Apparatus Inspection. Procedures The driver/operator should follow a systematic procedure for inspecting apparatus This ensures that all important.
3.3.4 Student Book © 2004 Propane Education & Research CouncilPage Operating a Dispenser to Fill DOT Cylinders by Volume DOT cylinders are designed.
Accident Prevention Manual for Business & Industry: Engineering & Technology 13th edition National Safety Council Compiled by Dr. S.D. Allen Iske, Associate.
Reproduction interdite © ALMA EUROPEAN CONSORTIUM Reproduction forbidden Design, Manufacture, Transport and Integration in Chile of ALMA Antennas Page.
ELEVATORS.
P U T T I N G P U B L I C S A F E T Y F I R S T What’s New in ASME A / CSA B44-07.
SERVICE TRAINING EXPERT ALPHASTAR 1132 © MAO-SE-TC 1132_SE_EX_Handout_EN_12_  Collision protection switch  Collision protection switch retrofit.
Transitions Lift & Elevator offers many options for different situations. Depending on the application, the dumbwaiter systems are tailored to best suit.
Transfer Station Safety OR WORKER AND PUBLIC RISK.
CodeDataPlate.com. INTRODUCTION HISTORY –First Introduced in 1996 Edition –Special Section in 2000 Edition (8.9) TEN YEARS OF PRACTICE –Learning Curve.
Cranes, Derricks, Hoists, Elevators, and Conveyors - Subpart N Section 6 Robert Poole St. Paul Fire & Marine Insurance Company.
2011 Changes Two Minute Drill
SAFE WORK INSTRUCTIONS
C.K. Pithawala College of Engg & Tech.
SAFE WORK INSTRUCTIONS
Brake System Problem Diagnosis & ABS Service Tips
Fire Alarm Systems for Emergency Operations of Elevators
SAFE WORK INSTRUCTIONS
Crane safety and inspections
The Basics of Overhead Crane Pre-op Inspections
Order of Engineers and Architects New Lebanese Standards Related to LIFTS NL EN 81standards Habib Srour.
Personal Protective Equipment
SAFE WORK INSTRUCTIONS
Emergency Electrical Power Supply for Buildings
Crane safety and inspections
AGENDA INTRODUCTION CELLS AND COMPONENTS PV PERFORMANCE
From AS :   Part 4— Commissioning, operation and asset management
F&T Inc. OVERHEAD CRANE SAFETY.
AGENDA INTRODUCTION CELLS AND COMPONENTS PV PERFORMANCE
Crane safety and inspections
Crane safety and inspections
Cranes and Hoists Standard 29 CFR Part
LIFT,ESCALATOR AND MOVING WALKS
Fire Protection Documentation
Presentation transcript:

CodeDataPlate.com

New in 2007 edition and in a MRL Pit Signage Marking of HY Jack Governor Escalator Governor 8.11 Requirements moved to 8.6 (‘08) Added Esc. Code Data Plate Others in Parts 5, 6 and 7 Also changes for those enforcing NBCC (Canada)

CodeDataPlate.com Violations A and later editions Part 8 A and later editions

CodeDataPlate.com Data Plates A17.1 Requirements –Counterweight Runby Data Plate –Crosshead Data Plate –Capacity Plate –Safety Marking Plate –Jack Marking Plate –Rail Lube Plate –Governor Marking Plate –Brake Marking Plates –Buffer Marking Plate

CodeDataPlate.com More Data Plates A17.1 Requirements (Continued) –Plunger Gripper Marking Plate –Hydraulic Machine & Valve Data Plates –Escalator/Moving Walk Brake Data Plates –Chain Data Plates (Dumbwaiter) –Rack & Pinion Data Plate –Code Data Plate A17.3 Requirements –Rail Lube Plate –Capacity Plate

CodeDataPlate.com Tags A17.1 Tags –Governor Rope Tag –Hoist Rope Data Tag –Acceptance Safety Test Tag –Resocketing Tag –Escalator Governor –Periodic Test Tags A17.3 Tags –Hoist Rope Data Tag –Chain Data Tag

CodeDataPlate.com Signs A17.1 Signs –Bottom Car Clearances –Refuge Space on Top of Car Enclosure –Working Areas in the Car or on the Car Top –Working Areas in the Pit –Location of Equipment - Governor Servicing –Freight Car Signage –Anti-creep Operation –Fire Service Signage

CodeDataPlate.com More Signs A17.1 Signs (Continued) –Emergency Brake Sign –No Jumper Sign adjacent to Bypass Switches –Escalator & Moving Walk Caution Signs –Additional (Esc. & M.W.) Signs A17.3 Signs –Freight Car Signs –Escalator Caution Signs –D/W “No Riders” Signs

CodeDataPlate.com Counterweight Runby Data Plate

CodeDataPlate.com ( )

CodeDataPlate.com Door Operator Plate Instructions Provided

CodeDataPlate.com and Under b-1995 and earlier Under 1996 and later A17.1 Req only not in A17.3 Hydro Traction

CodeDataPlate.com Jack, Safety Plank & Capacity Hydraulic (3.18.6) Traction ( ) Marking of Hydraulic Jack The exposed portion of each hydraulic jack after installation shall be plainly marked in a permanent manner with the following: (a) the name or trademark by which the organization that manufactured the hydraulic jack can be identified (b) the manufacturer’s designation of the type or model (c) year of manufacture Marking Plates for Safeties A metal plate shall be securely attached to each safety so as to be readily visible, and shall be marked in a legible and permanent manner with letters and figures not less than 6 mm (0.25 in.) in height indicating: (a) the type of safety, based on (b) the maximum tripping speed in m/s (ft/min) for which the safety is permitted (c) the maximum weight in kg (lb), that the safety is designed and installed to stop and sustain (d) the force in N (lbf) required to activate the safety or rope releasing carrier, if provided (e) the manufacturer’s name or trademark (07)

CodeDataPlate.com Other Hydraulic Markings

CodeDataPlate.com Safety Test Tag

CodeDataPlate.com Pull- thru + Buffer + Flex Hose Test Tag

CodeDataPlate.com For Roller Guides For Slide Guides A & A In A and later editions this information must be on Crosshead Data Plate

CodeDataPlate.com Governor Plate

CodeDataPlate.com Brakes Plates The emergency brake shall be provided with a marking plate indicating the range of total masses (car with attach- ments and its load) for which it is permitted to be used, the range of speeds at which it is set to operate, and the criteria such as rail lubrication requirements that are critical to the performance.

CodeDataPlate.com Buffer Marking Plates items and (for Oil Buffers)

CodeDataPlate.com Check for any Missing or Damaged Signs and Data Plates Machine Room –Brake Plates –Governor Plate –Code Data Plate –Ambient Air Plate –Hydro Data Plates –Warning Signs Fire Service Signs Hoistway and Pit –Crosshead Data Plate –Rail Lube Instructions –Warning Signs –Safety Plank Plate –Buffer Plate –Counterweight Runby Freight & Capacity

CodeDataPlate.com Inspection Tags Acceptance Tests –8.10 Requirements –New Installations –Alterations Periodic –8.11 Requirements – Tag –New under b-2008: Testing moves to 8.6

CodeDataPlate.com TN

CodeDataPlate.com TN

CodeDataPlate.com

Code Data Plates Required Information – Applicability of Inspection and Test Requirements Location –Mainline or on Controller (07) – Additional Plate for External Escalator Inspections Material and Construction –...shall remain permanently and readily legible.

CodeDataPlate.com SECTION 8.9 Requirement 8.9 contains requirements for all new and existing equipment within the Scope of this Code Required Information Data plate shall be provided and maintained that shall indicate the Code to be used for inspections and tests (see ). The data plate shall indicate the Code and edition in effect at the time of installation. The data plate shall also indicate the Code in effect at the time of any alteration and indicate the applicable requirements of 8.7.

CodeDataPlate.com Installation Code Edition Original Installation Date –Elevator Permit Date –Other Dates If Unknown Original Installation Code –Follows AHJ’s Effective Dates –Use ASME Effective Dates AHJ has no dates No AHJ GSA –Format is the same as in Inspector’s Guide

CodeDataPlate.com Equipment Without Alteration Older Installations –Use applicable adopted A-17.1 editions –Use locally adopted code/standards such as: Adopted A17.3- Edition California CA Title 8 - Group 2 Ohio Bulletin 110 (Red Book) Iowa 875-IAC Ch. 73 Massachusetts 524 CMR Missouri 11 CSR Pennsylvania PA 34 Ch. 7 Washington WAC Min. Std. –Use building code referenced A17.1 edition New Installations –Use applicable ASME edition as AHJ adopts

CodeDataPlate.com Edition Sensitive Items (85 years of code) A17.3 applies from d-1986 through d-2000 to Part XII Item 1.6 Car Emergency Signal there are 6 differences Space Guards A and later editions (also A17.3) Static Control a-1988 and later editions Glazing b-1989 and later editions & again in a-2005 Item 1.12/13 & 3.8 (Cab items) there are 16 differences and 16 more relating to car & hoistway doors & gates Door Restrictors b-1980, b-1983 and b-1989 differences Hydro RPR required for installations under c-1986 and later Fire Service b-1973, 1981, 1984, b-1989, 2000 and 2004

CodeDataPlate.com CDP Flow Chart

CodeDataPlate.com

Job Information Web, , phone or fax

CodeDataPlate.com Code Data Plate Order Form

CodeDataPlate.com Common Errors - Disconnect Change in Power Supply = or –Change of Voltage, Frequency or Number of Phases –Change from DC to AC –Change of combination of DC and AC Replace Wiring or Disconnect = or –Includes new machine room wiring, hoistway wiring and travelling cables –Requires conformance with Section 2.8 which includes reference to NFPA 70 (NEC)

CodeDataPlate.com Common Errors - Control Install like Controller = or Change of Motion Ctrl. = or Change in Operation = or Related requirements –Top of Car Inspection = or –Leveling = or –Anti-creep = –Stop Switch = (was in a-2002 and earlier) –Alter an EPD = or (‘07)

CodeDataPlate.com Common Errors - Jack Replace Jack with new Jack = Cut off head and weld onto new Cylinder, re-use the plunger = Related requirements –Plunger only = –Change of Working Pressure = –Relocation of Jack = –Relocation of Tank = –Plunger Gripper =

CodeDataPlate.com Custom Software

CodeDataPlate.com Custom Software

CodeDataPlate.com Custom Plates Alterations Under A Edition Alterations Under A Edition

CodeDataPlate.com Alteration Plate Door Operator Wiring Re-opening Devise Door Restrictor Plunger Gripper Valve Tank Limits Top of Car Insp.. Leveling Controller Replacement Emergency Operations

CodeDataPlate.com Jack Replacement Re-opening Devise Door Restrictor Rope Brake Cylinder Only Cab Interiors Valve Alteration Emergency Lowering HY Fire Service Alterations TR Field Marked Alteration Plate Covers Common Minor Alterations Instructions Provided

CodeDataPlate.com Code Data Plate Kits

CodeDataPlate.com Thank You - Questions