BVIT: An imaging, photon counter for high time resolution astronomy on SALT Jason McPhate, Oswald Siegmund, Barry Welsh, John Vallerga, Doug Rogers (Univ.

Slides:



Advertisements
Similar presentations
Time & Frequency Products R. Peřestý, J. Kraus, SWRM 4 th Data Quality Workshop 2-5 December 2014 GFZ Potsdam Recent results on ACC Data Processing 1 SWARM.
Advertisements

Chapter 8 The Sun – Our Star.
1 Space Sciences Lab, UC Berkeley, CA, USA High performance microchannel plate detectors for UV/visible Astronomy Dr. O.H.W. Siegmund Space Sciences Laboratory,
Optical Astronomy Imaging Chain: Telescopes & CCDs.
SPACE TELESCOPE SCIENCE INSTITUTE Operated for NASA by AURA COS Science Calibration & Instrument Status TIPS 20 Nov 2003 Last COS TIPS Aug 2003.
The Factors that Limit Time Resolution in Photodetectors, Workshop, University of Chicago, April 2011 What is known experimentally about timing determinants.
VLBI: Visible Light Broadband Imager Instrument Conceptual Design Presentation Tom Berger Lockheed Martin Solar and Astrophysics Lab.
Optical image tube with Medipix readout
+ Hard X-Ray Footpoint Motion and Progressive Hardening in Solar Flares Margot Robinson Mentor: Dr. Angela DesJardins MSU Solar Physics Summer REU, 2010.
GALEX UV Light-curves of M-Dwarf Flare Stars: “ THE FLARING UV SKY” Barry Welsh, Jonathan Wheatley & Stanley Browne (UC Berkeley) Richard Robinson (Catholic.
The Origin of Modern Astronomy Chapter 4:. Isaac Newton 1689.
SPIE Instr. for Astronomy, Marseille, John Vallerga, Optically sensitive MCP image tube with a Medipix2 ASIC readout John Vallerga,
Existing fabrication facilities for PC's for imaging MCP detectors Dr. O.H.W. Siegmund Experimental Astrophysics Group Space Sciences Laboratory University.
SPIE IR and Photoelect. Imagers and Detector Devices J. McPhate Jason McPhate, John Vallerga, Anton Tremsin and Oswald Siegmund Space Sciences.
Mid-IR photon counting array using HgCdTe APDs and the Medipix2 ROIC
Photon Counting Sensors for Future Missions
9th IWoRiD: Erlangen,July 2007, John Vallerga High resolution UV, Alpha and Neutron Imaging with the Timepix CMOS readout J. Vallerga, J. McPhate, A. Tremsin.
Space Astronomy: The UV window to the Universe, El Escorial, May 2007, John Vallerga The current and future capabilities of MCP based UV detectors J. Vallerga,
SPIE Instrumentation for Astronomy AO - June22, 2004 John Vallerga, Jason McPhate, Anton Tremsin and Oswald Siegmund Space Sciences Laboratory, University.
Reading Unit 28, Unit 29, Unit 30 Will not be covered by the first exam.
WSO Detector Workshop Leicester University, Dec. 2007, John Vallerga UV detectors in Space John Vallerga Space Sciences Laboratory University of California,
2nd Zwicky Informal Workshop - Berkeley 2005 May 26, 2005John Vallerga John Vallerga, Barry Welsh, Anton Tremsin, Jason McPhate and Oswald Siegmund Experimental.
Ch 25 1 Chapter 25 Optical Instruments © 2006, B.J. Lieb Some figures electronically reproduced by permission of Pearson Education, Inc., Upper Saddle.
NOvA meeting PIP Update W. Pellico. PIP Goals and Scope (Provided in 2011 – Directorate S. H. / DOE Talk ) Goals: Specific to the issues surrounding the.
Presentation by David Fong
1 Fluorescence Cameras -Dr James Milnes -Live Cell Imaging – Stem Cell Research -Portland Place, London, 24 June 2009 Live Cell Imaging.
Your Observing Challenge: White Dwarfs in Open Star Clusters.
 A monitor or display is an electronic visual display for computers.  The monitor consists of : o the display device o circuitry o enclosure The display.
10 Picosecond Timing Workshop 28 April PLANACON MCP-PMT for use in Ultra-High Speed Applications.
Agile: A Time-Series CCD Photometer to Study Variables Anjum Mukadam, Russell Owen, Ed Mannery University of Washington, Seattle.
TIPS presentation 19 July 2007Charles Proffitt COS-STIS TeamPage 1 STIS FUV MAMA Dark Current Charles Proffitt COS-STIS Team.
Progress in Chamber Simulation Experiments At UCSD Laser Facility Farrokh Najmabadi Kevin Sequoia, Sophia Chen HAPL Meeting September 24-25, 2003 University.
Elad Hadar Omer Norkin Supervisor: Mike Sumszyk Winter 2010/11, Single semester project. Date:22/4/12 Technion – Israel Institute of Technology Faculty.
The 4 functions of a computer are 1.Input 2.Output 3.Storage 4.Processing.
Measurement Results Detector concept works! Flood fields show MCP fixed pattern noise that divides out Spatial resolution consistent with theory (Nyqvist.
Cartigny, 2 July First Results Using the Medipix2 Photon Counting ASIC as Readout for a Micro-Channel-Plate Detector - Proposal for a New Wavefront.
Optical Observations of J : An LMXB in Transition Paul A. Mason New Mexico State University Emmanuel Gonzalez University of Texas at El Paso Edward.
DC12 Commissioning Status GOALS: establish operating conditions, determine initial calibration parameters and measure operating characteristics for the.
LLNL AO talk - Aug. 17, 2004 John Vallerga, Jason McPhate, Anton Tremsin and Oswald Siegmund Space Sciences Laboratory, University of California, Berkeley.
Microchannel plates have been a workhorse detector for NASA (+ESA) space-based UV missions Continue to be proposed for future Explorer and sounding rocket.
The Galaxy Viewed at Very Short Time-Scales with the Berkeley Visible Image Tube (BVIT) Barry Y. Welsh, O.H.W. Siegmund, J. McPhate, D. Rogers & J.V. Vallerga.
Development of a high-speed single photon pixellated detector for visible wavelengths Introduction A photon incident on the photocathode produces a photoelectron.
A First Look at the June Test Beam DAQ Hardware architecture Talk Presented 8 April, 2008 John Anderson HEP Electronics Group Argonne National Laboratory.
1 Access and Use of Auroral Imaging Data Harald U. Frey Space Sciences Laboratory University of California at Berkeley Credit: D. Hutchinson.
COS Training Series II. Optimizing Observations --- David Sahnow February mm.
SPACE TELESCOPE SCIENCE INSTITUTE Operated for NASA by AURA SMOV4 Requirements Review Cosmic Origins Spectrograph Scott D. Friedman STScI 30 July 2003.
33mm MCP Testing at UC Berkeley
Radioactive source and cosmic-ray test for the MWPC Davide Pinci on behalf of the Frascati-Roma1 MWPC group.
A U.S. Department of Energy Office of Science Laboratory Operated by The University of Chicago Argonne National Laboratory Office of Science U.S. Department.
GIST th -29 th Apr B.Stewart RAL In-orbit Mirror Performance.
Fluoroscopy. Real-time imaging Most general-purpose fluoroscopy systems use TV technology, operating at 30 frames/sec May be recorded (barium swallow.
WFC3 SMOV Report for TIPS 16 July 2009 John MacKenty This presentation contains material that is embargoed until after the SM4 ERO press conference. Images/spectra.
MPI Semiconductor Laboratory, The XEUS Instrument Working Group, PNSensor The X-ray Evolving-Universe Spectroscopy (XEUS) mission is under study by the.
F Monitor of Beam in the Abort Gap Randy Thurman-Keup DOE Review of Tevatron Operations at FNAL March 29-31, 2005 a.k.a. Abort Gap Integrator (AGI)
HOW TO SELECT DOUBLE STARS FOR OBSERVATION GENERAL CONSIDERATIONS UNDERSTANDING WDS DATA USING THE SKY X ON BARC0 TO CONFIRM YOUR PLAN OTHER PLANETARIUM.
COMPUTER COMPONENTS Ms Jennifer Computer Components.
High Voltage Power Supply for RPC Suvendu Nath Bose, Satyajit Saha, Sudeb Bhattacharya, Saha Institute of Nuclear Physics, Kolkata,, Description Presently.
Digital Light Sources First introduced in 2001.
V. Agapov, N. Sakva, D.Davydov, E.Katkova
Astronomical Spectroscopic Techniques
SOFIA — The Observatory
ISUAL Imager Stewart Harris.
ALD MCP 116 Life Test Update
Single Object & Time Series Spectroscopy with JWST NIRCam
JWST NIRCam Time Series Observations
Sun Notes.
Computer Case Houses computer components
Instrumentation for Colliding Beam Physics 2017
First Assessments of EUVI Performance on STEREO SECCHI
T2Kロシアグループに向けたMPPC(SiPM)の性能評価
Presentation transcript:

BVIT: An imaging, photon counter for high time resolution astronomy on SALT Jason McPhate, Oswald Siegmund, Barry Welsh, John Vallerga, Doug Rogers (Univ. of California, Berkeley – Space Sciences Laboratory) David Buckley, Amanda Gulbis, and Janus Brink (South African Astronomical Observatory – SALT) Technology and Instrumentation in Particle Physics, June 2011

Southern African Large Telescope Near copy of Hobby-Eberly Telescope at McDonald Observatory in Texas. Located at 32.4° S, 20.8° E, 1783 m – near Sutherland, South Africa. Effective 10m diameter multi-segmented, spherical primary mirror (91 x 1m hexagons). Telescope has a fixed zenith angle of 37°, and does not move during target tracking. Scientific instruments are housed in a prime focus payload that moves to track targets. Plate scale at BVIT focus is 220 µm/acrsec. Good seeing/focus is about 1 arcsec. J. McPhate (mcphate@ssl.berkeley.edu) TIPP 2011

Berkeley Visible Imaging Tube BVIT was installed in Auxiliary bay of the SALT prime focus payload in January 2009. BVIT was designed to do high time resolution astronomy (25ns precision) of variable objects At the heart of BVIT is a visible sensitive, photon counting, imaging sealed tube with time tagging electronics. Imaging capability allows for simultaneous acquisition of target, sky background, and field/comparison stars The photon counting nature allows BVIT data to be corrected post-facto for a number of observing difficulties: variable seeing/focus, tracking drift, telescope vignetting, etc. Similarly, light curve time binning can be selected during post processing to levels allowed by the source count rate. J. McPhate (mcphate@ssl.berkeley.edu) TIPP 2011

BVIT History Jan ’09 – Installed in situ in the SALT payload. Feb ’09 – Initial commissioning and science observations. Mar ’09 – Second run of science observations. Apr ’09 thru Aug ’10 – SALT upgrades (improved spherical aberration correction). Aug ’10 – BVIT upgraded with higher QE tube and faster computer, while payload off telescope. Dec ’10 – BVIT re-commissioning. Shutter problems prohibited full science operations. May ’11 – Shutter and computer hard drive replaced. Jun ’11 – Re-re-commissioning and science observations, including coordinated observations with RXTE. J. McPhate (mcphate@ssl.berkeley.edu) TIPP 2011

Berkeley Visible Imaging Tube J. McPhate (mcphate@ssl.berkeley.edu) TIPP 2011

BVIT Data Flow Light enters the enclosure and passes through the shutter, 2 filter wheels (color and ND), and an adjustable iris – before reaching the tube. Photons are converted to electrons by the photocathode, amplified by the MCPs, and collected by the cross delay line anode. Signals from the XDL anode are amplified and passed to two TDCs for position encoding and time stamping. The TDCs accept input alternately (“ping-pong” scheme) to reduce electronic deadtime. When one TDC receives a count it passes control to the other TDC. The TDCs calculate the X, Y position of each event, as well as the MCP pulse size (P) and arrival time (T) in units of 25 ns clock cycles since the last sync signal. An external sync signal resets the TDC counters once per second to keep clock drift to a minimum. The X, Y, P, and T for each count is passed to the onboard computer (via a National Instruments DIO-32HS acquisition card). The data acquisition software uses a double buffer system to minimize data loss while writing to disk. Data is stored on an onboard 500 GB hard drive. Each count takes 10 bytes. Data rates to the hard drive are limited to about 1.1 MHz. Above this rate, data is lost at transitions between buffer writes. At the end of the night, all the night’s data is downloaded to a hard drive in the SALT control room via BVIT’s 1 GB Ethernet connection. J. McPhate (mcphate@ssl.berkeley.edu) TIPP 2011

BVIT on the bench post upgrade BVIT Instrument BVIT CAD Model Amplifier HVPS TDCs LVPS Tube, Iris, FWs, Shutter BVIT on the bench post upgrade Tube heat sink Computer Delay Cables Glycol cooling lines Power consumption is ~64 watts, dominated by the TDCs, computer, and LVPS. Glycol cooling is run at ambient - 2°C, to prevent condensation. Tube background rate is temperature dependent, so the internal cooling lines go to tube heat sink first, then the CPU. J. McPhate (mcphate@ssl.berkeley.edu) TIPP 2011

BVIT Detector 25 mm active area, drop face sealed tube (~2 arcmin FOV at SALT plate scale) Z-stack of 10 µm pore, 60:1 l/d MCPs. Cross delay line (XDL) anode readout. Original tube (Jan ‘09) manufactured at UCB with blue S20 photocathode Upgrade tube (Aug ‘10) manufactured by Photonis/DEP, S25 (SuperGen II) photocathode BVIT Upgrade Detector: Custom Photonis/DEP tube with UCB-SSL XDL anode and S25 photocathode J. McPhate (mcphate@ssl.berkeley.edu) TIPP 2011

BVIT Tube QE and Filter Throughputs There is also an “open” position on the color filter wheel. ND filter selection: “Open”, 0.3, 1.0, 3.0, 4.0 Iris can be used to decrease the ratio of sky background counts to source counts being written to disk. Red: Original BVIT tube QE (S20). Bkg ~ 50 cps Green: New BVIT tube QE (S25). Bkg ~ 10 kcps Blue: 2cn Photonis XDL S25 tube, selected against because of higher background rate. Bkg ~ 60 kcps. J. McPhate (mcphate@ssl.berkeley.edu) TIPP 2011

BVIT Throughput (cont) Filter m = 15 m = 18 B - band 57 kcps 3.6 kcps V - band 35 kcps 2.2 kcps R - band 28 kcps 1.8 kcps H-alpha 1.6 kcps 100 cps Open 150 kcps 10 kcps While the detector and electronics can run at >2 MHz, the global count rate is limited to ~1 MHz by the computer’s ability to write data to disk. Global sky background rate can be choked back without source rate reduction by stopping down the iris. Expected count rates for 15th and 18th magnitude, flat spectral sources. To avoid detector burn-in and excessive local gain sag, sources brighter than ~100 kcps should not be observed without use of special observing techniques (telescope defocus, lower tube high voltage). This corresponds to a SNR of 3 in a 100 µsec bin. J. McPhate (mcphate@ssl.berkeley.edu) TIPP 2011

BVIT Detector Spatial Resolution Detector spatial resolution at nominal gain (about 5e6) is approximately 70 µm. This is well below the required resolution for operation on SALT (220 µm/arcsec, ~1 arcsec seeing). Furthermore, the resolution degrades gracefully, allowing operation at approx. 1/5 nominal gain. This will extend tube lifetime, and improve local count rate limits by roughly 5X. At modal gain, the resolution is dominated by photocathode to MCP gap charge spreading (indicated by the better resolution demonstrated by a hotspot produced on the MCP) Imaged Pinhole Resolution Hotspot Resolution J. McPhate (mcphate@ssl.berkeley.edu) TIPP 2011

User Interfaces Hardware control GUI: LabView VI controls most of the components via a small USB DIO card from National Instruments. Filter wheels (Finger Lakes Instr.) have their own USB controllers. The software has several safeguards built in. It monitors the HV current draw on the tube. If this exceeds a programmable limit, the HV is turned off. It will also turn off the HV is a hardware high count rate limit is exceeded (about 3 MHz). Data acquisition GUI: Visual C heritage software from the UCB group. This comes in two varieties. The first gives a real-time display of the image being acquired (shown above) and is useful for acquiring field verification images. The second is a streamlined version that streams the data to hard drive with minimal graphical update (no real-time image of PHD). J. McPhate (mcphate@ssl.berkeley.edu) TIPP 2011

UZ For – January 2009 (AM Her-type CV) Material from the secondary, M-type star in this system is accreting onto the primary white dwarf, but only at the magnetic poles. The interesting two step profiles of the eclipse ingress and egress are due to the nature of how the hot accretion spots on the white dwarf are obscured by the inclined orbit of the companion M-type star. The data acquired with BVIT is at higher time resolution than previously measured on this source and allows better characterization of these shoulder features. Light curve for the 18th magnitude eclipsing binary cataclysmic variable system UZ For. Data is in counts per 0.5 second bin. J. McPhate (mcphate@ssl.berkeley.edu) TIPP 2011

CN Leo – January 2009 M-type Flare Star Data is in counts per 1 second bin. We were fortunate to catch two small flares within a single observation on this star. Temporal expansion of the larger flare. This is the same data but now in 100 ms bin. Note the small precursor and the significant structure in the main flare. Data such as these are important for determining if micro-flares (such as these) are important heating mechanisms for the coronae of stars like our Sun. Resolving this question requires time resolution < 1 second. J. McPhate (mcphate@ssl.berkeley.edu) TIPP 2011

Future Plans Analysis of recently acquired data using upgraded BVIT. Move towards making BVIT a user facility instrument at SALT Improve user interface and integrate more completely with data acquisition software. Provide a portable data software pipeline for users (currently written in IDL). Possible second generation (BVIT 2) instrument GaAsP photocathode (better QE) Cross-strip anode readout (faster) More specifically designed electronics (smaller, lower power) Better optical design (possibly with grism or simultaneous multi-color capability) Faster write to disk speeds J. McPhate (mcphate@ssl.berkeley.edu) TIPP 2011

Acknowledgements The authors are indebted to the engineering and IT staff at SALT for many hours of support without which the success of BVIT would not be possible. This includes (but is not limited to) Ockert Strydom, Charl Du Plessis, Hamish Whittal, Simon Fishley, Garith Dugmore, Eben Wiid, Peter Menzies, and Ardisha Pancham. We would like to thank the following students and staff at UC Berkeley who worked on the design of BVIT and subsequent data processing: Rahul Barwani, Mike Quinones, Johathan Wheatley, Navid Radnia, and David Anderson. This work was support by NSF grants AST-0352980 and DBI-0552-099 to the University of California, Berkeley. J. McPhate (mcphate@ssl.berkeley.edu) TIPP 2011