Prepared by: Vortex Engineering Date: 9.March.2012 Floor Box ™

Slides:



Advertisements
Similar presentations
AT&T strives to provide a smooth and successful installation experience for our Customers. We will do all that we can to install your service on time and.
Advertisements

Steel Outlet Boxes Crouse-Hinds Training Module. Outline z Applications z Types of Steel Boxes y Options z Uni-Mount TM Cover z Pre-Fabricated Boxes z.
Electrical Safety Program. How Electricity Works Operating an electric switch is like turning on a water faucet. Behind the faucet or switch there must.
Build Your Own Future RC2 Serviceability. Build Your Own Future Safety and Ground Rules Before servicing, always remove A/C power from the unit and disconnect.
Safety Considerations. High voltage High current POWER SUPPLIES can cause burns or start fires even at low voltages MAINS VOLTAGE is potentially lethal.
1. How special is ONfinity CM2 Max compared with other portable interactive whiteboards currently available in the market ? Compared with other portable.
Hale Carlson Baumgartner, PLC Conference Room Technology.
Crestron FlipTops ™ Crestron FlipTops Redefines tabletop cable management and control for the modern conference room All-new family of configurable FlipTops.
InfraStruxure for Small IT Spaces Solution Introduction.
University of Alaska Fairbanks Environmental Health, Safety, & Risk Management Laboratory Sharps: Handling and Disposal November
Proper Use of Extension Cords Proper Use and Electrical Hazard Awareness for Extension Cord Users Module 2.
1 OFFICE ELECTRICAL SAFETY Environmental Energy Technologies Division (EETD) On the Job Training August 12, 2013.
Overhead Crane Safety.
Efficient flexibility in room management with SAUTER EY-modulo.
 Recognize the scope and structure of the OSHA standards.  Identify the common electrical hazards in long term care settings.  Discuss electrical safety.
Circuit Protection Electrical circuits require protection to prevent fire or electrocution in the event of a fault. There are two main types of circuit.
3200A Electrical Test Equipment Calibrator. Automatic Loop Correction To simplify calibration of loop testers, the 3200A can be fitted with the Auto.
Noadswood Science, 2012 Electrical Safety. Electricity Safety To be able identify safety features with electrical components Tuesday, August 11, 2015.
Georgia Tech Safety and Health Consultation Program ELECTRICAL SAFETY TOOL BOX SESSION.
Damien Francois EME 6396 Seminar in HPT UWF Summer 2010 Home office design for Clinical Research Associate.
Confidential and proprietary materials for authorized Verizon personnel and outside agencies only. Use, disclosure or distribution of this material is.
Purpose Power lines Equipment Assured Grounding GFCI Conclusion.
Unit 4, Lesson 9 Keeping You and Your Computer Safe AOIT Computer Systems Copyright © 2008–2013 National Academy Foundation. All rights reserved.
ELECTRICAL SAFETY OSHA 29 CFR 1910 SUBPART S
The Saigon CTT Semester 1 CHAPTER 9 Le Chi Trung.
2005 Planning Meeting Introducing the WCP Range The New Standard in Call Point Technology.
1 Electrical Safety. 2 Electrical Hazards & OSHA 29 CFR (b)(1) requires: “Electrical equipment shall be free from recognized hazards that are.
How does AC line noise create problems?
1 WAO (WORK AREA OUTLET) BASIC TELECOMMUNICATIONS.
Copyright © 2008–2011 National Academy Foundation. All rights reserved. Unit 4, Lesson 9 Keeping You and Your Computer Safe AOIT Computer Systems.
MNM Fatal Fall of Person Fall of Person February 27, 2014 (Iowa) February 27, 2014 (Iowa) Underground Limestone Mine Underground Limestone Mine.
Using electricity! Chapter 19. Quick Bites Do you know who discovered electricity? – Thomas Edison – Benjamin Franklin – President Bush – Arnold Schwazenagger.
© Penn State Food Safety and Sanitation for Food Manufacturers Course Equipment Sanitary Design.
Proper Use of Extension Cords
Manual Density Business Today
TELECOMMUNICATIONS SPACES
Electrical Safety in the Home 1.Circuit Breakers 2.Fuses 3.Wall Outlets 4.Circuit Breakers 5.GFCI/RCD.
Residual Current Device Created by Clare,Huw and Conner.
ELECTRICAL FIRES CAN BE PREVENTED! By PowerCheck.
Electrical Safety, Subpart K
Safety Around Irrigation Systems
PHYSICS – Dangers of electricity. LEARNING OBJECTIVES Core State the hazards of: – damaged insulation – overheating of cables – damp conditions State.
EXTENSION CORD SAFETY Bureau of Workers Comp PA Training for Health & Safety (PATHS) 1PPT
Pole Vault Systems What do I need to know?. Below is a list of some of the most frequently asked questions about Pole Vault systems: 1.What is a Pole.
Level 1 Diploma in Plumbing Studies © 2013 City and Guilds of London Institute. All rights reserved. 1 of 14 PowerPoint presentation Power tools Unit 104:
DOMESTIC ELECTRICAL CIRCUITS National Diploma Mechanical and Electrical Services Construction.
Chapter 3 PHYSICAL INJURY AND CONTROLS 3.2 Electrical Safety
Level 1 Diploma in Electrical Installation © 2014 City and Guilds of London Institute. All rights reserved. 1 of 7 PowerPoint presentation Supporting information.
1 OFFICE ELECTRICAL SAFETY Energy Technologies Area (ETA) On the Job Training May 25, 2016.
Georgia Tech Safety and Health Consultation Program
POWERLINC A flexible, reconfigurable power distribution system designed specifically for control rooms. 1.
Electrical Safety.
SecureConnect Remote Operator
Circuit Protection Unit 9.
PA Training for Health & Safety
Electrical Safety Describe and explain how a fuse works as safety device. Describe and explain how a circuit breaker works as a safety device. Explain.
Starter Review your filament lamp experiment and make corrections (in green pen) Review your test and complete the front cover sheet, correct any mistakes.
HOME ELECTRICAL SAFETY
Controlling where Electricity Goes
ASHRAE, California Title 24, NEC
Computer Repair & Maintenance
Domestic Electricity AIM: To understand the use of domestic electricity and safety features such as fuses, circuit breakers and the earth circuit
Safety Meeting Topics Standby Generator Safety
Click anywhere to get started…
Floor outlet boxes British Standard
ELECTRICAL INSTALLATION
SCITEQ End closure series
Presentation transcript:

Prepared by: Vortex Engineering Date: 9.March.2012 Floor Box ™

The problem with current floor boxes An Overview. Floor boxes are a practical and commonly used mechanism to provide convenient below floor access to General Purpose Outlets (GPO's) as well as voice/data connections for telephone, computer network access and other connections (e.g. POWER, DATA, OPTIC FIBRE, USB, HDMI, VGA, RCA, TV etc.) Besides usability and aesthetic issues, current floor box designs pose a major safety and liability risk where the incorrect use doesn’t allow the end user to safely plug-in or access electrical cables without the potential for electrocution. Even the correct usage of a current floor box can pose a hazard where cables or leads may be sheared or damaged when exiting from the front flap. Recognised by Australian National University as a hazard alert back in 2008: Recognized by Safe Work SA as an OHS hazard:

The problem with current floor boxes Guillotine points resulting in cut electrical cable. When an electrical cable is allowed to exit from the side of a current floor box and the lid is closed shut, the lid acts as a guillotine and can damage the cables by either shearing or cutting the cable exposing the copper wires. Even the correct usage of a current floor box can pose a safety hazard where cables or leads may be sheared or damaged when exiting from the front flap.

The problem with current floor boxes Electrocution Risk. If exposed wires come into contact with parts of the floor box, which are metallic, it has the potential to make the entire box “live”. If the end user attempts to connect or remove cables, touching either the exposed copper wires or any internal metallic surface, may pose an electrocution hazard. Hazard reports have shown that on many occasions, the Residual Current Device (RCD) has failed to activate and users received an electric shock when they made contact with the exposed “live” electrical wire. The RCD may not activate even though live electrical wires are exposed.

The problem with current floor boxes Aesthetics and tripping hazard. Cables protruding from undesignated exit points are aesthetically displeasing and look unprofessional. Floor box lid does not close flush when cables are protruding from sides and undesignated exit points. It is a tripping hazard.

™ Floor Box Solution Vortex patented novel lid design, in one swoop, eliminates all the risks associated with current floor boxes. Patented design overcomes the current floor box problems by eliminating the possibility of electrical cables ever protruding from the side by forcing them to exit from the front of the floor box where intended.

™ Floor Box Solution This design forces the correct usage and placement of the protruding cables no matter where the end user places them when closing the floor box lid.

The sliding closing action of the Oruga TM lid forces all leads to exit from the front of the floor box. Sliding closing action ensures that cables cannot protrude from the sides of the floor box. ™ Solution to the guillotine effect of floor box lids. Floor box flap is bevelled at an angle to the frame (frame also bevelled at same angle to flap) which ensures that leads will never be sheared by the flap, even when a user steps on the flap!

™ Solution to electrocution risk. Floor box lid forces correct usage in an intuitive way. This makes it impossible for cables to be sheared thus completely eliminating the risk of electrocution. Floor box lid is made entirely out of ABS plastic which also eliminates the possibility of the box ever becoming “live” if it ever comes into contact with exposed copper wires. This is a great advantage over metal floor box lids.

™ Solution to aesthetics and tripping hazard. The beveled flap and frame also provide the advantage that when the floor box closes, even with cables protruding from the flap, the Oruga floor box lid, including the flap, is flush with the ground, more so than any other floor box on the market thus eliminating any tripping hazard. Forced orderly exit of cables from the flap of the lid makes for a professional looking corporate environment.

SMALL - caters for 2 x Wall Plates (up to 12 data connections) MEDIUM - (shown) caters for 4 x Wall Plates (up to 24 data connections) LARGE - caters for 6 x Wall Plates (up to 36 data connections) ™ Sizes and fitting. The versatility of the lid design also enables it to be retro-fitted to currently installed floor boxes. Custom sizes can be specified and manufactured on request. It can be fitted yourself, or we also offer a fitting service to install the ORUGA Floor Box. ORUGA is available in 3 sizes (Small, Medium and Large) however, custom sizes can also be made to order. The medium size box is our most popular option and suitable to the needs of 95% of our customers.

™ Summary and additional features. Oruga lid is able to be retro ‐ fitted to any current floor box thus transforming a hazardous floor box into a safe and hazard free floor box. The ORUGA makes it impossible for cables to be sheared thus completely eliminating the risk of electrocution. Patented Steel Box design allows more working space inside the box for plugs & connections which in turn allows for a smaller lid footprint and more aesthetically pleasing look. Any type of connection that can be installed on a standard wall plate may be used (e.g. POWER, DATA, OPTIC FIBRE, USB, HDMI, VGA, RCA, TV etc.) The box design easily caters for 6 connections of Cat6A or Cat7 per wall plate without affecting the cable bend radius with ample room (100mm) to work with behind the wall plates. By far, the safest, most functional and user friendly floor box in the world!

™ Floor Box Solution For more information about the ORUGA TM Floor Box, Vortex Engineering on