Fire protection systems

Slides:



Advertisements
Similar presentations
Sprinkler Systems and Standpipe Operations
Advertisements

Approved Commercial Cooking Systems and UL 300 Regulation
Approved Commercial Cooking Systems and UL 300 Regulation Garden Grove Fire Department Fire Prevention Bureau.
General Safety Overview and Information
The Care and Feeding of Silane Art Garcia FM Global March 23, 2006.
Fire Protection Systems
State Fire Marshal Question and Answer Session with the Louisiana Automatic Fire Alarm Association March 19, 1999.
Chapter 16 Lesson Goal After completing this lesson, the student shall be able to operate various fire detection, alarm, and suppression systems and operate.
Aspirated Smoke Detection
NFPA 96 and Building Code Requirements for Commercial Kitchen Hood Systems Presentation for the Sevier County Fire Code and Building Code Officials Presented.
Buildings and Structures 2 Fixed Installations Aim To provide students with information to allow them to recognise the types of fixed fire protection.
How would you explain this on the 3394? If Fire Erupts on YOUR Boat If Underway, stop the boat Have everyone who is not wearing a PFD put one on Position.
Evaluating Kitchen Hoods Rudy Hawkins C-1. Hood Designs and Categories - Background o Commercial Kitchen Hoods have two designs: o Exhaust Hoods o Grease.
Unit 3 Fire Suppression Section 1 Detection and Alarm Systems.
Water Based Sprinkler Systems 2 major different types of water sprinkler systems Wet pipe system Dry pipe system.
Foundations of Real Estate Management
Basic Fire & Life Safety for Radiation Safety Professionals Robert Emery, DrPH, CHP, CIH, CSP, RBP, CHMM, CPP, ARM Vice President for Safety, Health, Environment,
© Siemens Industry, Inc Confidential / Drive Your Business Forward Ignite the Power of New Products and Partnerships Siemens Fire Partner Summit.
Fire Detection and Suppression Chapter 7 Special Extinguishing Systems.
Chapter 12 Systems and Equipment for Fire Protection.
N.F.P.A. 13R Justin Bohlmann FIR-204.
4/15/2017 7:34 AM Fire Sprinkler Systems Prepared by Thomas Bartsch Chief Fire Inspector (ret) Former Chief of Department, Valley Stream, NY © 2007.
The Life Safety Surveyor Facility Tour
Zone Valves.
Automatic Sprinkler System. Importance of Sprinklers First line of protection – small fires Enhanced protection Business protection – less interruption.
AUTOMATIC SPRINKLERS.
FIREFIGHTER I LESSON 15. SPRINKLER SYSTEM DESIGN AND OPERATION Series of sprinklers arranged to automatically distribute enough water to extinguish or.
3-1 NFIRS 3 Structure Fire Module. 3-2 ObjectivesObjectives The participants will be able to: –describe when the Structure Fire Module is to be used.
Hangar Water Based Fire Protection
Purpose of Standpipe and Hose Systems
Chapter 9. Please read chapter 9.  Please review, know and understand the terms related to fire protection page 284.  Know the Classifications of.
Chapter 12 Protective Systems. Introduction Protective systems help guard lives and property Detection systems detect presence of fire and alert occupants.
 Familiarization of system  Locations of: Hydrants FDC Knox Box FACP Sprinkler Riser Room Liquid Oxygen  Unique Fire Protection Element Smoke Curtain.
Fire Detection, Protection, and Suppression Systems
FIRE PROTECTION FUNDAMENTALS Chapter 7: WATER-BASED FIRE PROTECTION SYSTEMS & EQUIPMENT INTRO SLIDE.
Automatic Sprinkler Systems
Computer & Telecom Rooms. 2 Business or building protection ? BUSINESS PROTECTION  Smoke is the problem  Small and Medium Size (
CVFD Training – Fire Protection Systems
Chapter 12 Protective Systems. Introduction Protective systems help guard lives and property Detection systems detect presence of fire and alert occupants.
Ted “Smitty” Smith  This slide show contains multiple timed questions. All questions can be answered using the International Fire Code, The National.
Module C Sprinkler systems (4-20)
Welcome Presentation On Office security system. Group Members: Md. Emdadul Haque Md. Sahed Hasan Md. Samsul Arefin Khokan Das.
Patrick Thornton, SNS/FPE June 9, 2008
Business Owners and Managers and the Fire Code
Fire Department Hydraulics
Dry and Wet Chem Systems Ch. 8, pages Dry Chemical Systems Dry Chem. System Components Dry Chem. Sequence of Operation Applications for Dry Chem.
ADT490 TroubleShooting Device Failures. 2 Introduction ‣ Many problems are external to FAS ‣ Many are device problems.
CHAPTER 12 Copyright © 2007 Thomson Delmar Learning 12.1 Protective Systems.
FIRE SERVICES AT DATA CENTRE
Fire Protection Systems Chapter 6. Fire Protection Systems Most of the time you will work with an electrical engineer or fire-protection designer to coordinate.
Chapter 5 ID 234 Building Codes Fire Resistant Materials and Assemblies.
Spray Booths Follow safe operating instructions. Spray-finishing operations  Organic materials  Inorganic materials  Dispersed form  Deposited to.
Chapter 6 ID 234 Building Codes Fire Suppression.
Subpart F - Fire Protection & Prevention ( ) Flammables/combustibles - Approved containers Fire protection program/equipment 2A fire extinguishers.
ME444 ENGINEERING PIPING SYSTEM DESIGN
Presented by John Lewandowski and Mike Larabel Inspection, Testing, and Maintenance of Kitchen Hood Systems Michigan Fire Inspectors Society Winter Educational.
KEK, 04/28/061 Safety Plan Assumptions Break out of fire in the Beam Tunnel is negligible Cables in the Service Tunnel is main fire load They are combustible.
Public Safety Committee New Construction Dallas Fire Rescue Inspection and Life Safety Education Section Chief James Adams June 13, 2016.
Fire Protection Systems for Facility Managers Michael Salazar NICET Level 2.
FIRE PROTECTION & SECURITY in ELI Beamlines
Presentation On Office security system
What Library Staff Should Know About Fire Safety
AUTOMATIC SPRINKLERS.
NFIRS 3 Structure Fire Module
Sprinkler Systems: Review and Response Considerations
FIRE SUPPRESSION SYSTEM.
Module 4: Storage and Dispensing Locations
Bella Vista Fire Department Procedures on Sprinkled Buildings
Presentation transcript:

Fire protection systems Fire protection is the first defense against fires and comes in many forms and designs. Includes Water based suppression systems, Fire detection, and special extinguishing systems as well as special detection systems. Fire protection systems

Fire Sprinkler Systems Water based fire protection systems have been around for about a hundred years.

Fire Lines Components Water main DCVA – Double Check Valve Assembly Fire Department Connection (FDC) Indicator Valve Assembly Post Indicator Valve (PIV) Wall Post Indicator Valve (WPIV) A fire line supplies fire protection systems from a water supply and may include many components.

DCVA Control Valve Check Valve

Fire Department Connections

City of Bothell Requirements Locations of FDCs Within 50 feet of structure. Within 50 feet of a fire hydrant. (Outside of the Downtown Sub area) Can be combination or single use. Painted Labeled for type and address (If needed) As the downtown sub-area becomes more densely developed, you will see more wall mounted connection and control points. Some requirements are changing as we change the overall design of the downtown sub area. Combination systems join standpipe and sprinkler system together from one source.

Indicator Valve Assemblies Post Indicator Valve. Wall Post Indicator Valve. Outside Screw and yoke Purpose: To control the flow of water to the fire protection system. Visible indicator of the position of the device. OPEN/SHUT Visible screw threads Security Chains Tamper device Post indicator valves are the most common Wall post indicator valves are becoming more common due to restrictions of a more densely built community. Control valves may be located at the riser room, and not outside the building.

General Design Standard for the City of Bothell

General Design Standard for the City of Bothell FDC Check Valve Feed from main PIV Control Valve Fire Line

Fire Suppression Riser Purpose To control and distribute the water to the suppression devices. To allow reporting to a notification device of tampering or water flow. Risers come in many forms, from a standard wet pipe riser to much more complicated systems.

Shot Gun Riser Water is in the system at all times. Released by the activation of a sprinkler head.

Wet Pipe Risers

Riser in Normal Condition

Riser in Pre-alarm Condition

Riser in Alarm Condition (Water Flowing)

Sprinkler Systems

Dry Pipe Riser Used for areas subject to freeze. The piping above the valve assembly has no water in it. Usually has an air compressor to hold back the water from entering the pipes in non-alarm conditions.

Dry Pipe Riser Face Bolt Latch Dry area of riser Valve Cap Water Inlet Pressurized Air Face Bolt Latch Dry area of riser Air pressure hold the valve cap shut against the water pressure. The latch holds the valve in the open position until it is released. The face bolts can be removed to gain access to the dry area of the riser valve assembly. Valve Cap Hinge Water Inlet

Basic Principle Heat from combustion breaks the bulb or fusible link on a sprinkler head. Pressurized air in the branch and main lines travels through the system escaping through the opened sprinkler head or heads. Air from the system leaves the main chamber of the riser valve. Release of the pressurized air allows for the valve to lift off the inlet. Water moves from the main line into the system lines.

Special Requirements Time constraints for air to leave the system and water to reach the sprinkler head. NFPA 13 – 60 seconds of less for water delivery. If the system takes too long… An “Accelerator” may be needed. Air compressor to keep pressure in the system and keep the main alarm valve from opening. Signal to alarm system when system goes “WET”.

Pre-Action System Usually used for areas within a building that may need special application due to sensitive equipment or where accidental activation is undesired. Pre-action systems are hybrids of wet, dry, and deluge systems, depending on the exact system goal. There are two main sub-types of pre-action systems: single interlock, and double interlock.

Pre-Action Single interlock systems are similar to dry systems except that these systems require that a “preceding” fire detection event, typically the activation of a heat or smoke detector, takes place prior to the “action” of water introduction into the system’s piping by opening the pre-action valve, which is a mechanically latched valve. Deluge system are typical of these.

Pre-Action Double interlock systems are similar to deluge systems except that automatic sprinklers are used. These systems require that both a “preceding” fire detection event, typically the activation of a heat or smoke detector, and an automatic sprinkler operation take place prior to the “action” of water introduction into the system’s piping.

Pre-Action Activation of either the fire detectors alone, or sprinklers alone, without the concurrent operation of the other, will not allow water to leave the piping system. Because water does not enter the piping until a sprinkler operates, double interlock systems are considered as dry systems in terms of water delivery times, and similarly require a larger design area.

Pre-Action

Deluge System In these systems, sprinklers are open at all times. There is NO fusible link or temperature sensitive bulb.

Deluge System A fire detection device controls the main valve. Very similar to a pre-action system. When the system is activated, the valve opens, allowing large amounts of water to flow through all of the sprinklers. They are usually used in facilities that contain hazardous materials such as: flammable liquids, chemicals, and explosives. A “Flooding” response where water is simultaeously delivered to all sprinkler heads in the design area.

Standpipe System

Standpipe System A system of pipes and connection points. Mainly used to extend the reach of hose lines. Typical connections are 2 ½ inch and 1 ½ inch. Connections are normally located in stairwells. Can also be found in hallways, roofs and places where the spacing between access points exceeds 300 feet.

Standpipe System Systems can be as complicated as the building and its contents require.

Standpipe System System can be normally dry. Supplied by water from a fire apparatus. System can be normally wet. Supplied by water from the fire line. Supplemented with water from a fire apparatus. System can be a combination. Combined with the sprinkler system.

Standpipe System Class I – A Class I standpipe system shall provide a 2 1/2 inch hose connection for use primarily by trained personnel or by the fire department during initial response. This class has no hose attached.

Standpipe System Class II – A Class II standpipe system shall provide 1 1/2 inch hose stations to supply water for use primarily by trained personnel or by the fire department during initial response. These are typically found in cabinets with 100’ of hose.

Standpipe System Class III – A Class III standpipe system shall provide 1 1/2 inch hose stations to supply water for use by trained personnel and a 2 1/2 inch hose connection to supply a larger volume of water for use by fire departments and those trained in heavy fire streams. Many times these connections will provide a 2-1/2 inch reducer to a 1-1/2 hose connection.

Special Extinguishing Systems FM-200 An extinguishing system that utilizes a chemical extinguishing agent. The agent is less hazardous than Halon. Leaves no residue on equipment. Uses a interlock release system. Usually smoke detectors. Countdown timer to allow for escape from the room prior to release. Manual activation and abort buttons. Visual and audible alarms.

FM-200 System Extinguishing agent canister Discharge Nozzles

FM-200 System Temporary abort button Manual Activation button

Kitchen Hood Systems

These are just some of them. Kitchen Hood Systems NFPA 96 Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations NFPA 13 Standard for the Installation of Sprinkler Systems NFPA 17 Standard for Dry Chemical Extinguishing Systems NFPA 17A Standard for Wet Chemical Extinguishing Systems UL 300 Standard for Fire Testing of Fire Extinguishing Systems for Protection of Commercial Cooking Equipment UL 710 Standard for Exhaust Hoods for Commercial Cooking Equipment These are just some of them.

Kitchen Hood Systems Why do we need hood extinguishing systems? What are some of the hazards associated with kitchen cooking? How frequently are hoods to be cleaned? How frequently are the suppression components to be serviced? What types of extinguishing agents are used?

Kitchen Hood Systems NFPA 96 Cleaning schedule Monthly - Facilities that serve solid fuel cooking need to be cleaned. Quarterly - Facilities that serving high volume cooking like 24hr restaurants and wok cooking . Semi- Annual - Facilities that serve moderate volume cooking to be cleaned. Annually - Facilities that serve low volume cooking like churches, day camps, senior centers.

Kitchen Hood Systems Typical System Layout

Kitchen Hood Systems

Kitchen Hood Systems Grease build up on roof

Kitchen Hood Systems A dirty hood system

Kitchen Hood Systems Grease baffle filters

Kitchen Hood Systems

A duct with heavy build up Kitchen Hood Systems A duct with heavy build up

Kitchen Hood Systems A Cleaned duct

Kitchen Hood Systems Concerns of a dirty hood system. Build up of grease from grease laden vapors. Producing a highly combustible fuel load. Grease is a corrosive material that over time can weaken or destroy structural members. Rapid fire spread.

Kitchen Hood Systems Activation process Detection of a fire Fusible link Shut down of gas supply and/or electricity of heat sources Shut down of make-up air. Notification to FA panel Fire alarm activated. Activation of suppression chemical. Extinguishment of fire. These all may occur at nearly the same time

Kitchen Hood Systems

Fire Detection and Notification Systems

Types of Systems Conventional panel Reports location of fires by “zones” Different types of signals Water flow Smoke Heat detector Manual Pull Trouble Supervisory

Conventional systems Annunciator Panel Control Panel Manual Pull Station Smoke detector Flow switch Horn/Strobe

Addressable Systems Monitors each individual device. Reports Detector activation Trouble Supervisory Displays specific information Detector location Type of detector Supervisory signals Duct detector activation Trouble signals Missing devices Power failure Communication error

Panels come in a wide variety of styles and abilities. Addressable Panels Panels come in a wide variety of styles and abilities.

Addressable Components

System Particulars Each device is in constant communication with the panel. Panel can identify the location and condition of the device. Can monitor other devices such as VESDA and Special extinguishing systems and Smoke Control.

Communication Methods International Fire Code 2009 allows for alternate methods of communication with the monitoring station. What does this mean?

New technology must meet NFPA 72 standards New technology is now replacing some of the long standing modes of communicating with the monitoring station. POTS - Copper wire Digital Dialer DAC – Digital Alarm Communicator STU – subscriber terminal unit New technology must meet NFPA 72 standards RF – Radio Frequency Cellular – cell system IPDAC – Internet VOIP

VESDA Very Early Smoke Detection Apparatus

VESDA Can be used where due to sensitive equipment, early detection is needed.

VESDA How it works Constantly “sniffing” the air. Uses a high efficiency aspirator. Detects minuscule amounts of smoke by the use of a laser. Alerts in a pre-alarm and alarm manner. Multiple levels of alarm are available before a full alarm is activated.

VESDA Aspirating smoke detector (Laser type). Pipe Network