1 Portable Hydrocarbon Sensors for Oil Sands Applications M.T. Taschuk 1, Q. Wang 1, S. Drake 1, A. Ewanchuk 2, M. Gupta 1, Y. Zhou 1, D. Ha 1, M. Alostaz.

Slides:



Advertisements
Similar presentations
D e t e c t o r s f o r H P L C.
Advertisements

Teledyne Analytical Instruments
Chem. 133 – 2/19 Lecture. Announcements Lab Work –Turn in Electronics Lab –Starting Set 2 HW1.2 Due Today Quiz 2 Today Today’s Lecture –Noise –Electrochemistry.
11 Components of Optical Instruments Lecture Spectroscopic methods are based on either: 1. Absorption 2. Emission 3. Scattering.
PROVIDED BY EMAD BEHDAD SPECIALIZED PROTECTION AND CORROSION OF MATERIALS LECTURERS H.MONAJATI,PHD JAFARI,PHD ISLAMIC AZAD UNIVERSITY OF NAJAFABAD BARANCH.
7. Beer’s Law and It’s Implications for Instrument Construction.
AAS and FES (Ch 9, 7th e, WMDS)
AA and Atomic Fluorescence Spectroscopy Chapter 9
Atomic Absorption Spectrometry Dr AKM Shafiqul Islam University Malaysia Perlis.
HL Chemistry - Option A: Modern Analytical Chemistry ATOMIC ABSORPTION SPECTROSCOPY.
Applications of CCD Array Spectrometers in Undergraduate Education at EIU Jonathan Blitz and Daniel Sheeran Department of Chemistry.
The Business of Science ® © Oxford Instruments 2009 Oxford Instruments Industrial Analysis Oxford Instruments Analytical GmbH Wellesweg 31 D Uedem.
427 PHC.  Atomic emission spectroscopy (AES) is based upon emission of electromagnetic radiation by atoms.
LIBS : L aser I nduced B reakdown S pectroscopy LIBS is an analytical method by which one can determine (qualitatively and quantitatively) the elemental.
Sergey Kucheryavski Raman spectroscopy Acquisition, preprocessing and analysis of spectra.
Lecture #2 Seeing the light 1/29/13. What happens to light when it interacts with matter? Reflects Absorbed Refracts Changes speed Polarized Diffracts.
AOSC 634 Air Sampling and Analysis Lecture 1 Measurement Theory Performance Characteristics of instruments Nomenclature and static response Copyright Brock.
Monroe L. Weber-Shirk S chool of Civil and Environmental Engineering Atomic-Absorption (AA) Spectroscopy 
Field Methods XRF Copyright © 2013 by DBS. Atomic Spectroscopy for Metal Analysis Introduction to the Principles of Atomic Spectroscopy Atomic spectroscopy:
LIBS Detector System Design & Preliminary Testing David Hahn, Tom Moskal, Ken Iida Department of Mechanical Engineering University of Florida July 9, 2001.
Time out—states and transitions Spectroscopy—transitions between energy states of a molecule excited by absorption or emission of a photon h =  E = E.
Fundamental of Fiber Optics. Optical Fiber Total Internal Reflection.
Common types of spectroscopy
Illumination and Filters Foundations of Microscopy Series Amanda Combs Advanced Instrumentation and Physics.
Nitride Materials and Devices Project
Atomic Emission Spectroscopy
Atomic Emission Spectrometry
Flame Photometry Flame atomic emission spectrometry
Project Overview Laser Spectroscopy Group A. A. Ruth Department of Physics, University College Cork, Cork, Ireland.
5.4 Notes.
What is spectroscopy? It is the study of how matter interacts with electromagnetic radiation (gamma rays down to radio waves) Matter can interact with.
1 University of Petra Faculty of Science & Arts Department of Chemistry Seminar I.R Spectroscopy By Firas Al-ouzeh Supervisor : Nuha I. Swidan Summer 2007.
5 Components Common to All Optical Spectrometers Source Transparent Sample Holder Wavelength Selector Radiation Detector Signal Processor and Readout.
Atomic Emission Spectrometry By: Alexa Kunch
Biomedical Applications of Plasma Spectroscopy: A Preliminary Study Dr. Unnikrishnan V. K. Associate Professor Department of Atomic and Molecular Physics.
Profile Measurement of HSX Plasma Using Thomson Scattering K. Zhai, F.S.B. Anderson, J. Canik, K. Likin, K. J. Willis, D.T. Anderson, HSX Plasma Laboratory,
Introduction to Spectrochemical Methods
Decontamination of filed equipment used in environmental site characterization and ground-water monitoring projects University of Arkansas 11/13/2006 By.
RamanRaman. Scattering Tyndall scattering – if small particles are present During Rayleigh scattering (interaction of light with relatively small molecules)
Electron Microscopes Used to count individual atoms What can electron microscopes tell us? Morphology – Size and shape Topography – Surface features (roughness,
Miriam Israelowitz 1 and Dr. David L. Wilson 2 1 Department of Physics, Case Western Reserve University, Cleveland OH, 2 Deparment of Biomedical Engineering,
Fluorometric determination of riboflavin
Optical Characterization methods Rayleigh scattering Raman scattering transmission photoluminescence excitation photons At a glance  Transmission: “untouched”
Fluorometric determination of riboflavin. Introduction.
Atomic spectroscopy Elemental composition Atoms have a number of excited energy levels accessible by visible-UV optical methods ä Must have atoms (break.
States and transitions
DECam Daily Flatfield Calibration DECam calibration workshop, TAMU April 20 th, 2009 Jean-Philippe Rheault, Texas A&M University.
Parameter optimization for the determination of BSH in whole blood by 10 B-NMR Keijiro Saito K. Yoshino, M. Muto, A. Ishikawa and H. Ohki Department of.
Light Emitting Diode By Rabail Faizan.. What is a LED?  A light-emitting diode (LED) is a semiconductor light source. LEDs are used as indicator lamps.
Atomic Fluorescence Spectroscopy. Background l First significant research by Wineforder and Vickers in 1964 as an analytical technique l Used for element.
Hyperspectral remote sensing
Optical Sources By Asif Siddiq. LED Electron from the conduction band recombines with a hole in the valance band of.
Lecture 13 Light: the Cosmic Messenger Telescopes and Observational Astronomy.
Fluorometric determination of riboflavin
Chem. 133 – 2/18 Lecture. Announcements Homework Set 1.2 (bold problems) – due today Quiz 2 Today Electronics Lab Reports – due Tuesday Seminar this Friday.
GS-1150 HANDHELD SPECTROPHOTOMETER. ABOUT GAMMA SCIENTIFIC With over 50 years of experience in developing commercial light measurement instruments, Gamma.
Portable SERS Detector for Simultaneous Detection of Trace-level Polycyclic Aromatic Hydrocarbons on Superfund Sites Wayne Weimer (PI) and Monika Wilson,
“Cell Packing indicator”
SWNT Periodic Table Primary and secondary gap semiconductors.
Flame Emission Spectrometry
Chem. 133 – 3/30 Lecture.
Spectroscopy Chapter 7.
NANO 230 Micro/NanoFabrication
Strategies for Eliminating Interferences in Optical Emission Spectroscopy Best practices to optimize your method and correct for interferences to produce.
Practical Absorbance and Fluorescence Spectroscopy
Chem. 133 – 2/16 Lecture.
Elemental composition
GAJENDRA KUMAR EC 3rd YR. ROLL NO
化工群英文示例 沙鹿高工 簡佩琳.
Fluorescence of Samarium Ions in Strontium Bismuth Borate Glasses
Presentation transcript:

1 Portable Hydrocarbon Sensors for Oil Sands Applications M.T. Taschuk 1, Q. Wang 1, S. Drake 1, A. Ewanchuk 2, M. Gupta 1, Y. Zhou 1, D. Ha 1, M. Alostaz 2, A. Ulrich 2, D. Sego 2, Y.Y. Tsui 1 1. Department of Electrical and Computer Engineering, University of Alberta, Edmonton, Alberta, Canada, T6G 2V4 2. Department of Civil and Environmental Engineering, University of Alberta, Edmonton, Alberta, Canada, T6G 2W International Oil Sands Tailings Conference, December 5th - 8th, Edmonton, Alberta, Canada

2 © Varian © Paramount Low-Cost Portable Rapid Measurements Low Resolution & Specificity High Cost Unportable Long Turnaround High Resolution & Specificity Concept Performance Tradeoffs 6 ppm NA

3 Concept Low-cost, Rapid Screening Tools © Varian © Paramount

4 Outline Device Physics Why light-emitting diodes (LED)? LED induced fluorescence (LEDIF) Optical Theory & Specifications Device Performance Naphthenic Acids (NA) in Process-Affected (PA) water Hydrocarbon Detection Instrument Outlook Summary

5 Why LEDs? Haitz’s Law Similar to Moore’s Law Power per LED doubles every 2.3 years Cost per Lumen halves every 3 years Impacts many optical technologies: communications lighting chemical sensors fluorescence Source: Nature Photonics 1 (2007) pp. 25

6 Broad bandwidth signals Highly sensitive: ppb LODs typical Minimal sample preparation Non-destructive For LEDs: broad bandwidth degrades signals limits on excitation wavelengths more flexible output LED Induced Fluorescence (LEDIF) Technique Characteristics Hannes Grobe ground state excited states excitation light emitted light

7 Prototype Measurement Process 1.Ultraviolet LEDs emit light UV LEDs Collection Lens Sample Cuvette Parabolic Mirror Spectrometer

8 Prototype Measurement Process 1.Ultraviolet LEDs emit light 2.Parabolic mirror focuses on sample UV LEDs Collection Lens Sample Cuvette Parabolic Mirror Spectrometer

9 Prototype Measurement Process 1.Ultraviolet LEDs emit light 2.Parabolic mirror focuses on sample 3.Sample fluoresces UV LEDs Collection Lens Sample Cuvette Parabolic Mirror Spectrometer

10 Prototype Measurement Process 1.Ultraviolet LEDs emit light 2.Parabolic mirror focuses on sample 3.Sample fluoresces 4.Parabolic mirror captures emission UV LEDs Collection Lens Sample Cuvette Parabolic Mirror Spectrometer

11 Prototype Measurement Process 1.Ultraviolet LEDs emit light 2.Parabolic mirror focuses on sample 3.Sample fluoresces 4.Parabolic mirror captures emission 5.Collection lens couples to spectrometer UV LEDs Collection Lens Sample Cuvette Parabolic Mirror Spectrometer

12 Optics: Excitation: 265 nm – 340 nm Emission: 200 nm – 800 nm f/3 collection; f/4 spectrometer Hardware Commercial, off the shelf components No moving parts Rapid measurement: < 5 seconds Prototype Cost: $10k Prototype Specifications

13 Outline Device Physics Why light-emitting diodes (LED)? LED induced fluorescence (LEDIF) Optical Theory & Specifications Device Performance Naphthenic Acids (NA) in Process-Affected (PA) water Hydrocarbon Detection Instrument Outlook Summary

14 LEDIF of NA Prototype Responsivity 285 nm, N avg = 5, t g = 5 s NA detectable well below 10 mg L -1 in 25 seconds Device performance expected to improve Concentrations by FTIR

nm, 68 ppm NA, N avg = 5, t g = 5 s LEDIF of NA Unfiltered Process-Affected Water NA signature in unfiltered process-affected water No sample preparation 25 second measurement

16 LEDIF of Hydrocarbons Naphthalene 265 nm, N avg = 1, t g = 5 s LOD < 1 ppm 5 second measurement Can trade speed for sensitivity Fine spectral features broadened by LED bandwidth

17 LEDIF of Hydrocarbons Summary Table CompoundLimit of DetectionMeasurement Time Naphthenic Acids< 5 ppm25 s Napthalene< 1 ppm5 s Phenanthrene< 1 ppm5 s Pyrene< 100 ppb1 s Diesel< 100 ppm5 s Gasoline< 10 ppm5 s Crude Oil< 1 ppm5 s

18 LEDIF of Hydrocarbons Diesel in Soil Diesel-saturated sand samples Preliminary evidence suggests we can distinguish weathered diesel and diesel Further work required to establish calibration curve for weathering 265 nm, N avg = 5, t g = 1 s (WD), t g = 2 s (D)

19 Outline Device Physics Why light-emitting diodes (LED)? LED induced fluorescence (LEDIF) Optical Theory & Specifications Device Performance Naphthenic Acids (NA) in Process-Affected (PA) water Hydrocarbon Detection Instrument Outlook Summary

20 © Varian © Paramount Low-Cost Portable Rapid Measurements Low Resolution & Specificity High Cost Unportable Long Turnaround High Resolution & Specificity Concept Future Work Today 2011

21 Instrumental Outlook Room for Improvement More LEDs: 2X Smaller! Bigger! Improved f/#: 10X Improved Optics: 2X

22 Summary Field portable hydrocarbon sensor developed NA LOD < 5 mg L -1, NA detected in unfiltered PAW Other compounds successfully detected at ppm level Rapid measurements: 25 s for NA, ≦ 5 s for remainder Prototype cost: $10k Future Work Expect 10X to 100X improvement Handheld devices possible Inline, real-time monitors possible 6 ppm NA

23 Acknowledgements

24 Portable Hydrocarbon Sensors for Oil Sands Applications: Additional Slides M.T. Taschuk 1, Q. Wang 1, S. Drake 1, A. Ewanchuk 2, M. Gupta 1, Y. Zhou 1, D. Ha 1, M. Alostaz 2, A. Ulrich 2, D. Sego 2, Y.Y. Tsui 1 1. Department of Electrical and Computer Engineering, University of Alberta, Edmonton, Alberta, Canada, T6G 2V4 2. Department of Civil and Environmental Engineering, University of Alberta, Edmonton, Alberta, Canada, T6G 2W International Oil Sands Tailings Conference, December 5th - 8th, Edmonton, Alberta, Canada

25 Off-the-shelf LED ~ 5% of bench top power Trade resolution for power Why LEDs? Comparison with Benchtop Instruments © Varian

26 Excellent agreement with Varian Eclipse data LED related signals removed from prototype signal Further work required to optimize signals LEDIF of NA Comparison with Benchtop Instrument 280 nm270 nm

27 Device Performance Characteristic Spectra 265 nm excitation, 1000 ms acquisition, 5 averages, 1.8 nm smooth 13.7 mg/L Napthanic Acid in Water Good spectra observed Significant scatter from LED at 265 nm and ~500 nm Post processing can separate peaks

28 LEDIF of Hydrocarbons Pyrene LOD < 100 ppb 1 second measurement 265 nm, N avg = 1, t g = 1 s

29 LEDIF of Hydrocarbons Phenanthrene 265 nm, N avg = 1, t g = 5 s LOD < 1 ppm 5 second measurement Can trade speed for sensitivity Fine spectral features broadened by LED bandwidth