OSHA Region IV Electrical Outreach Construction Industry Photos 29 CFR 1926 Regulations.

Slides:



Advertisements
Similar presentations
Electrical Safety.
Advertisements

Electrical Safety.
13 PURPOSE: PROTECT PEOPLE WORKING ON OR NEAR EXPOSED ENERGIZED OR DEENERGIZED EQUIPMENT 18.
FHM TRAINING TOOLS This training presentation is part of FHM’s commitment to creating and keeping safe workplaces. Be sure to check out all the training.
Scissor Lift Safety Training
You will learn about… Isolating Circuits Testing Circuits
By: Aseem Aggarwal. Causes of Electrocution Fatalities Contact with Overhead Power lines Contact with Live Circuits Poorly Maintained Extension Cords.
OSHA Office of Training and Education
OSHA Region IV Electrical Outreach General Industry Photos 29 CFR 1910 Regulations.
Young Worker Safety Resource Center, adapted from OSHA Office of Training and Education Electrical Safety.
Electrical Safety and Grounding Essentials Copyright © Texas Education Agency, All rights reserved.
ELECTRICAL SAFETY / E N V I R O N H & S T R A I N I N G P R O G R A M ELECTRICAL SAFETY OSHA requires that electrical equipment be approved for use and.
Practice Statement The effective use of Isolate and Insulate equipment and procedures to provide the necessary level of safety when performing Live Line.
Electrical Safety.
Proper Use of Extension Cords Proper Use and Electrical Hazard Awareness for Extension Cord Users Module 2.
OSHA Office of Training & Education
Stairways and Ladders.
Walking-Working Surfaces
1 Telecom Cabling Ladder safety. 2 OSHA Office of Training & Education ation Telecom Cabling Stairways and Ladders.
 Recognize the scope and structure of the OSHA standards.  Identify the common electrical hazards in long term care settings.  Discuss electrical safety.
Occupational Safety and Health Course for Healthcare Professionals.
Union College EHS Training 1 Electrical. 2 Introduction An average of one worker is electrocuted on the job every day There are four main types of electrical.
Hazard - Inadequate Wiring
Electrical Safety - Construction. Electricity - The Dangers About 5 workers are electrocuted every week Causes 12% of young worker workplace deaths Takes.
Walking, Working Surfaces
Sub Part K Electrical - Installation Safety Requirements (a) Covered. Sections through contain installation safety requirements for.
Purpose Power lines Equipment Assured Grounding GFCI Conclusion.
BUILDING TRADE SAFETY ELECTRICAL SAFETY.
Safety Training For The Non-Qualified
ELECTRICAL SAFETY OSHA 29 CFR 1910 SUBPART S
Scissor Lift Safety Training Working Safely on Scissor Lifts 29 CFR OSHA Scaffolding Safety Requirements.
Electrical This presentation is designed to assist trainers conducting OSHA 10-hour General Industry outreach training for workers. Since workers are.
All Colby employees work with and around electricity on a daily basis. This Safety Talk focuses on the basic electrical safety elements to protect you.
Electrical Safety.
Electrical Safety in Construction. Objectives In this course, we will discuss the following: Common electrical hazards Standards relating to those hazards.
OSHA Office of Training and Education - Revised by TEEX 12/04/07 1 Walking-Working Surfaces.
Copyright  Progressive Business Publications Electrical Safety.
Health & Safety Life Book AM ST p. 1 v.01 - Aug.18, 2011 Working at Height Portable Ladders Design Specifications The use of home made ladders.
1a.  Exposed part  Live or energized part  De-energized part 1a.
Student XXX BCT 480 Hazard Recognition Site Report November 15, 2004
Electrical Safety. Definitions v Exposed part v Live or energized part v De-energized part 1a.
ELECTRICAL SAFETY. ELECTRICAL INSPECTION THE FOLLOWING EXAMPLES ARE INTENDED TO ASSIST THE BUILDING MANGER IN DETERMINING THE DEGREE OF COMPLIANCE, WTHIN.
Proper Use of Extension Cords
Tulane University - Office of Environmental Health & Safety (OEHS) Electrical Safety For Office, Facility, and Laboratory Employees Tulane University October.
Electrical Hazards Temporary Wiring and Lighting Systems.
Safety on Call ELECTRICAL SAFETY. Safety on Call YOU WILL LEARN ABOUT Hazards of Electricity Isolating Circuits Testing Circuits Work on Energized Equipment.
Office of Safety & Health Consultation presents
Electrical Safety Craig Shurson CSP, ARM Regional Loss Control Coordinator Hortica - The Florists Mutual Company.
Log dumps, Ponds and Yards Section L of the Forest Activities Code.
EXTENSION CORD SAFETY Bureau of Workers Comp PA Training for Health & Safety (PATHS) 1PPT
Electrical Work Practices City of Council Bluffs Presented by: SilverStone Group © 2012 Zywave, Inc. All rights reserved.
HOUSE WIRING Final Review. Electricity Electricity = flow of electrons Conductor= electricity passes thru easily - Metal, water, person Insulator = restricts.
Chicago Area Facilities (CAF) Electrical Safety Program.
Working On or Near Energized Conductors and FR Clothing.
Screening to Identify Unsafe Electrical Products * * These comments are those of the CPSC staff, have not been reviewed or approved by, and may not necessarily.
ELECTRICAL SAFETY GA Ag Ed Curriculum Office To accompany the Georgia Agriculture Curriculum Lesson AG-AMI VGP.
Electrical Safety OSHE 382, Spring 2016
Walking and Working Surfaces
“Success in Safety”.
PA Training for Health & Safety
Electrical Equipment CSP uses conventional electrical equipment in the majority of areas All installations follow the mandatory electrical codes The.
Subpart K Electrical Long recognized as a serious hazard.
Electrical Equipment CSP uses conventional electrical equipment in the majority of areas All installations follow the mandatory electrical codes The.
Personal Protective Equipment
Electrical Safety Review Compliance Assistance Region IV
Electrical Safety.
Protection of power conductors from mobile equipment
Equipotential Grounding Procedures Protective Grounding Training
Click anywhere to get started…
    ELECTRICAL SAFETY    .
Presentation transcript:

OSHA Region IV Electrical Outreach Construction Industry Photos 29 CFR 1926 Regulations

Construction Industry Photos Standard – (b)(1) Description –Fall Protection must be provided and used when working on towers and poles.

Construction Industry Photos Standard – (d)(1)(iv) Description –Protective grounds shall be applied on the disconnected(de-energized) lines or equipment to be worked on.

Construction Industry Photos Standard – (j) Description –Grounding cables and attachments must be capable of conducting the anticipated fault current.

Construction Industry Photos Standard – (j) Description –Grounding cables and attachments must be secured to equipment in such a manner as to maintain adequate grounding. The manner in which the grounding attachment was installed in this photo is not adequate.

Construction Industry Photos Standard – (d)(3) Description –All pulling and tensioning equipment shall be isolated, insulated, or effectively grounded.

Construction Industry Photos Standard – (d)(1)(iv) Description –Use of proper equipment for grounding de- energized power lines is paramount to protecting employees engaged in line construction and maintenance.

Construction Industry Photos Standard – (c)(2)(ii) Description –Grounding Rods were not driven into the ground sufficiently to get an adequate ground.

Construction Industry Photos Standard – (b) Description –Danger signs shall be used where an immediate hazard exist

Construction Industry Photos This is a general view of an electrical Sub- station

Construction Industry Photos Standard – (j) Description –Ground lead conductance must be capable of conducting the anticipated fault current.

Construction Industry Photos Standard – (a)(15)(i) Description –For lines rated 50kv and below, minimum clearance between the lines and any part of the crane or load shall be 10 feet.

Construction Industry Photos Standard – (a)(15)(ii) Description –For lines rated over 50kv, minimum clearance between the lines and any part of the crane or load shall be 10 feet plus 0.4 inch for each 1kv over 50 kv.

Construction Industry Photos Standard – (a)(3) Description –Before work is begun the employer must ascertain that electrical circuits are not concealed behind walls or other locations in which contact can be made.

Construction Industry Photos Standard – (a)(2)(ii)(J) Description –Extension cord sets used with portable electric tools and lights shall be designed for hard or extra-hard usage.

Wire Gauge Cords are offered in many lengths and are marked with a size or "gauge." The gauge is based on the American Wire Gauge (AWG) System, in which the larger the wire, the smaller the AWG number. For example, a 12 gauge wire would be larger, and can power larger wattage appliances, than a 14 gauge wire.

Wire Classes 12/3 means “12 gauge wire” and “/3” means that there are three wires in the cable UL indicates the wire has been certified by the Underwriters Laboratory to be safe SJ means “appliance cord, stranded conductors, cotton layer between wire and insulation, jute filler, rubber outer jacket, lighter service”. (S used by itself means extra hard service; SV is light service only.) T means load temperature must be less than 140 degrees F (in dry conditions). W means “wet use types”.

Construction Industry Photos Standard – (a)(2)(ii)(F) Description –Temporary lights will not be suspended by their cords unless they are designed for this purpose.

Construction Industry Photos Standard – (a)(2)(ii)(J) Description –Electric extension cords used in the workplace must be of the three wire type.

Construction Industry Photos Standard – (a)(2)(I) Description –Electrical cords located on the ground must be protected from vehicular traffic.

Construction Industry Photos Standard – (g)(1)(iii)(D) Description –Electrical cords and cables will not be attached to building surfaces

Construction Industry Photos Standard – (g)(2)(iii) Description –Electrical cords used in the workplace must be in continuous lengths without splice.

Construction Industry Photos Standard – (a)(1) Description –The bulb is removed from an electrical light socket exposing employees to the hazard of contacting energized parts.

Construction Industry Photos Standard – (b)(2 Description –Walking spaces, walkways, and similar locations shall be kept clear of cords so as not to create a hazard to employees.