Components of Radiographic Image Quality

Slides:



Advertisements
Similar presentations
Technical Aspects: the machine the image
Advertisements

Advanced Biomedical Imaging Lecture 3
Ch. 14 Four Radiographic Qualities Ch
Radiographic Film & Intensifying Screens
Formation Characteristics
4 Producing Quality Radiographs.
Advanced Biomedical Imaging Lecture 4 Dr. Azza Helal A. Prof. of Medical Physics Faculty of Medicine Alexandria University.
Chapter 18 Radiographic Exposure
IMAGE FORMATION  Introduction  The Invisible and Visible Image  Image Characteristics.
Radiographic Quality Chapter 5.
Digital Radiography.
Resident Physics Lectures
Topic 3 Selection of kV High kV scattered radiation is energetic. Angle of rays is same as those of primary beam and is not deflected very much. Follows.
Chapter 17 The Grid So far we have discussed how kVp, patient size and collimation impact scatter radiation. As the part size and kVp increase, scatter.
Resident Physics Lectures
Chapter 19 & 20 Image Quality & Techniques
Analyzing the Image Density. Density Overall blackening of the image.
Part II Image Quality 1  Image Quality  Photographic Quality  Geometric Quality 2.
Technical Factors or Prime Factors
Dr. Mustafa Zuhair Mahmoud Mr.Ali B Alhailiy بسم الله الرحمن الرحيم 1.
FILM ARTIFACTS.
Chapter 15 Radiographic Intensifying Screens And Cassettes
Chapter 9 Film & Film Holders.
Copyright © 2012, 2006, 2000, 1996 by Saunders, an imprint of Elsevier Inc. Chapter 8 Dental X-Ray Image Characteristics.
RAD 254 Chapter 11 Radiographic Film/Receptor
 QC testing of screen speed should occur on acceptance and then yearly.  Evaluate first whether similar cassettes marked with the same relative speed.
Most of the images recorded during conventional radiography are obtained with film/screen combination image receptors. Which in lessens the patient dose.
Intensifying Screens Kyle Thornton DMI 50B.
RAD 354 Chapt. 13 Intensifying Screens
FILM CASSETTES & INTENSIFYING SCREENS WEEK 9
INSTRUMENTATION. ELECTRICAL REQUIREMENTS AND EFFICIENCY  Effective voltage  High frequency inverter technology (over 10,000Hz)  Constant potential.
1 Components of Image Quality & Radiographic Artifacts Radiologic Technology A SPRING 2012.
Quality Control.
IMAGE QUALITY REVIEW RT
Dr Mohamed El Safwany, MD.
Components of Image Quality & Radiographic Artifacts Radiologic Technology A Spring 2010 Final Final.
Image Receptor Systems
Image Quality Radiographic Resolution.
Geometric Factors Focal Spot Object Film Object b a h c Film B A H C
Components of Image Quality & Radiographic Artifacts
Exposure Factors or Prime Factors
IMAGE QUALITY AND ARTIFACTS 1 2 WHY YOU SEE WHAT YOU SEE… The films or images have different levels of density – different shades of gray X-rays show.
RAD 254 Chapter 16 Image Quality Film factors Geometric factors Subject factors.
PRINCIPLES OF TECHNIQUE AND EXPOSURE
Radiographic Quality Visibility and Sharpness
Image Quality Q&A. RAPHEX Diagnostic Question 2001 D9: The imaging system which is best for visualizing small high contrast objects is: A. Computed tomography.
Film Optical Density Spectral Matching & sensitometry.
BME5002 Image Processing Lecture 1 John G. Harris 1/26/01.
Image Production and Evaluation NOTE: QA AND QC ARE USED INTERCHANGABLY IN APPLETON AND LANGE.
FILM CASSETTES & INTENSIFYING SCREENS WEEK 9
Grids George David Associate Professor Department of Radiology
Copyright ©2012 by Pearson Education, Inc. All rights reserved. Essentials of Dental Radiography for Dental Assistants and Hygienists, Ninth Edition Evelyn.
IMAGE RECEPTORS. Follow the Sequence- Film System Tube Tube Patient Patient (bucky) or non-bucky (bucky) or non-bucky Cassette Cassette INTENSIFYING SCREEN.
Image Receptors Film Construction, Film Handling, Cassette Construction, DarkRoom, Digital Imaging 1.
Summary of Rotational Panoramic Radiography. Theory of Rotational Panoramic Radiography Panoramic Radiography –Unique in that the focus of the horizontal.
Image Receptor Unsharpness By Professor Stelmark.
Lavin: Chapter 7 CTVT: pp
Analog X-ray Imaging Recommended Book: Walter Huda, REVIEW OF RADIOLOGIC PHYSICS By: Maisa Alhassoun
RADIOGRAPHIC QUALITY S. Guilbaud, Education Director School of Radiologic Sciences.
Optimizing The Image RVT: Chapter 7
Exposure Factors or Prime Factors
INTENSIFYING SCREENS.
Chapters 21 & 22.
Quality Control Testing of Screen Speed
Resident Physics Lectures
RECORDED DETAIL.
Image Production and Evaluation
RECORDED DETAIL.
Dept of Radiodiagnosis, BJMC, Pune
Presentation transcript:

Components of Radiographic Image Quality Radiologic Technology 244 created: Fall 2005 Rev 12-01-2009

Review handouts

Main Factors Affecting Recorded Detail kVp & mAs Technique Selection (Time) Motion Object Unsharpness Focal Spot Size SID (Source to Image Distance) OID (Object to Image Distance) Material Unsharpness/ Film Screen Combo

Factors that affect Recorded Detail Geometric unsharpness OID SID SIZE SHAPE Motion unsharpness (blurring) Intensifying Screens Film Speed / Composition Film – Screen contact Kvp & Mas (density / visibility)

GEOMETRIC QUALITIES DETAIL DISTORTION MAGNIFICATION

The degree of sharpness in an object’s borders and structural details. How “clear” the object looks on the radiograph

Recorded Detail Other names: -sharpness of detail -definition -resolution -degree of noise

What are these What does they measure?

Factors Affecting DENSITY PATIENT THICKNESS,PATHOLOGY MAS & KVP SID

POOR DETAIL GOOD DETAIL

Motion Can be voluntary or involuntary Best controlled by short exposure times Use of careful instructions to the pt. Suspension of pt. respiration Immobilization devices

Decrease Motion Unsharpness Instruct patient not to move or breath Use Immobilization devices Use Short exposure times Lock equipment in place

NAME 4 CAUSES

Blurring of image due to patient movement during exposure.

Focal Spot Size Smaller x-ray beam width will produce a sharper image. Fine detail = small focal spot (i.e. small bones) General radiography uses large focal spot Beam from penlight size flashlight vs. flood light beam

FOCAL SPOT ANGLE

Object Unsharpness Main problem is trying to image a 3-D object on a 2-D film. Human body is not straight edges and sharp angles. We must compensate for object unsharpness with factors we can control: focal spot size, SID & OID

SID Source to Image Distance The greater the distance between the source of the x-ray (tube) and the image receptor (cassette), the greater the image sharpness. Standard distance = 40 in. most exams Exception = Chest radiography 72 in.

SID Shine a flashlight on a 3-D object, shadow borders will appear “fuzzy” On a radiograph it’s called ______________ A true border – _____ Farther the flashlight from object = sharper borders. Same with radiography.

OID Object to Image Distance The closer the object to the film, the sharper the detail. OID , penumbra , sharpness  OID , penumbra , sharpness  Structures located deep in the body, radiographer must know how to position to get the object closest to the film.

Distortion Misrepresentation of the true size or shape of an object MAGNIFICATION (size distortion) TRUE DISTORTION (shape distortion)

Shape Distortion Misrepresentation of the shape of an object Controlled by alignment of the beam, part (object), & image receptor Influences: Central ray angulation & body part rotation

Elongation Foreshortened Normal

Distortion (x-ray beam not centered over object & film) Distortion (object & film not parallel)

Central Ray Radiation beam diverges from the tube in a pyramid shape. Photons in the center travel along a straight line – central ray Photons along the beam’s periphery travel at an angle When central ray in angled, image shape is distorted.

Distortion of multiple objects in same image (right) due to x-ray beam not being centered over objects.

Central Ray Angulation Body parts are not always 90 degrees from one another Central ray angulation is used to demonstrate certain details that can be hidden by superimposed body parts. Body part rotation or obliquing the body can also help visualize superimposed anatomy. NAME 3 EXAMPLES

MAGNIFICATION caused by: TUBE CLOSE TO THE PART (↓SID) PART FAR FROM THE CASSETTE (↑ OID) Compensate for MAG : ↑ OID by ↑ SID = “increase SID 7” for every 1” OID”

Size Distortion & SID Major influences: SID & OID As SID , magnification  Standardized SID’s allow radiologist to assume certain amt. of magnification factors are present Must note deviations from standard SID

In terms of recorded detail and magnification, the best image is produced with a small OID and a large SID.

What can be done to improve the detail with a large OID?

Use a smaller FS

40” SID VS 72” SID

Size Distortion & OID If source is kept constant, OID will affect magnification As OID , magnification  The farther the object is from the film, the more magnification

How can it be measured?

Measuring % of Magnification SID SOD

Measuring % of Magnification What is the % of mag when you have a 72” SID and 4” OID? DO the math…………

Material Unsharpness Equipment used can contribute to image unsharpness Fast film/screen combinations = decrease in image sharpness Slower film/screen combinations = increase in image sharpness

Intensifying screens Lower patient dose Changes resolution of image slow screens less LIGHT = better detail Faster – less detail (more blurring on edges)

Intensifying Screens: Review Located inside the cassette (film holder) Calcium Tungstate Blue to purple light Rare Earth Green & Ultraviolet light

POOR SCREEN CONTACT FOAM BACKING HELPS TO PLACE INTENSIFYING SCREENS IN DIRECT CONTACT WITH THE FILM – NO GAPS IF GAPS – MORE LIGHT CAN BE EMITTED IN SPACE, CAUSING THE IMAGE TO BE OF POOR DETAIL

WIRE MESH SCREEN CONTACT TEST

Screen Speed Efficiency of a screen in converting x-rays to light is Screen Speed.

Spectral Matching (F/S) What does it mean? Name the two types of screen phosphors What light spectrum do they emit?

Spectral Sensitivity Film is designed to be sensitive to the color of light emitted by the intensifying screens. Blue LIGHT– Conventional Calcium Tungstate screen Green, Yellow-Green LIGHT – Rare Earth screen

Spectral Matching (F/S systems)

Spectral Matching (F/S systems) Red safe light

Safe lights What wattage bulb? Distance from counter top?

Review of Film Characteristics Size of silver halide crystals & emulsion thickness determine speed of film and degree of resolution Speed – the response to photons Resolution – the detail seen

What are these What are they made of

Film Speed / Crystal size Larger crystals or Thicker crystal layer Faster response= less detail, and less exposure (chest x-ray) Finer crystals / thinner crystal layer =Slower response, greater detail, more exposure (extremity)

IMAGE ON FILM SINGLE EMULSION = BETTER DETAIL DOUBLE EMULISON = LESS DETAIL PARALLAX With double emulsion – an image is created on both emulsions – then superimposed – slight blurring of edges

Extremity vs Regular cassettes

QUANTUM MOTTLE Film grain, or graininess, refers to the tiny black spots that make up the visible image, one grain from each silver halide crystal exposed MORE COMMON IN CR SYSTEMS NOW NOT ENOUGH PHOTONS TO CREATE IMAGE

Factors Affecting mAs LIST 6 factors

Factors Affecting mAs Patient factors: size of pt., density of tissue, pathology kVp Distance - how Grids Film/Screen Combinations Processing

Technique /Denisty CHANGES

Log denisty H & D curve

a densitometer, measures film blackness. Film blackness is the relationship of the intensity of the light that hits the film from the view box (incident intensity) to the intensity of the light transmitted through the film (transmitted intensity). These measurements plotted on a graph produce a characteristic curve. The limitations of the human eye determine the useful density range in diagnostic radiography. The diagnostically useful range of densities is 0.25 to 2.5. The later module on exposure calculation considers this in more detail.

Film latitude ? What does it mean how does it plot on the curve?

Main Factors Affecting Recorded Detail kVp & mAs Motion Object Unsharpness Focal Spot Size SID (Source to Image Distance) OID (Object to Image Distance) Material Unsharpness/ Film Screen Combo