4/30/20151 Presenter:Jitendra Thakur Moderator:Mr.Lalit K Gupta B.Sc.MIT(2007) BPKIHS,Dharan.

Slides:



Advertisements
Similar presentations
Technical Aspects: the machine the image
Advertisements

IMAGE ARTIFACTS.
Artifact analysis.
Formation Characteristics
Advanced Biomedical Imaging Lecture 4 Dr. Azza Helal A. Prof. of Medical Physics Faculty of Medicine Alexandria University.
Primary Exposure Factors IV
Chapter 18 Radiographic Exposure
IMAGE FORMATION  Introduction  The Invisible and Visible Image  Image Characteristics.
Components of Radiographic Image Quality
Radiographic Quality Chapter 5.
Radiographic Film Artifacts n DMI 50B n Kyle Thornton.
Digital Radiography.
Resident Physics Lectures
RAD 354 Chapt. 28 The Digital Image Spatial resolution Contrast resolution Contrast-detail curve Pt. dose considerations.
Chapter 17 The Grid So far we have discussed how kVp, patient size and collimation impact scatter radiation. As the part size and kVp increase, scatter.
Resident Physics Lectures
MAMMO QC – covered in week 8
Analyzing the Image Density. Density Overall blackening of the image.
Part II Image Quality 1  Image Quality  Photographic Quality  Geometric Quality 2.
Technical Factors or Prime Factors
Dr. Mustafa Zuhair Mahmoud Mr.Ali B Alhailiy بسم الله الرحمن الرحيم 1.
DARKROOM ,PROCESSING & Artifacts REVIEW
Technical Artifacts and Errors
FILM ARTIFACTS.
 QC testing of screen speed should occur on acceptance and then yearly.  Evaluate first whether similar cassettes marked with the same relative speed.
Most of the images recorded during conventional radiography are obtained with film/screen combination image receptors. Which in lessens the patient dose.
1 Components of Image Quality & Radiographic Artifacts Radiologic Technology A SPRING 2012.
Quality Control.
IMAGE QUALITY REVIEW RT
Dr Mohamed El Safwany, MD.
Components of Image Quality & Radiographic Artifacts Radiologic Technology A Spring 2010 Final Final.
Image Quality Radiographic Resolution.
Mammography Questions and Answers
Geometric Factors Focal Spot Object Film Object b a h c Film B A H C
Components of Image Quality & Radiographic Artifacts
Prime Exposure Factors 1
RAD 254 Chapter 15 Radiographic Technique 4 primary exposure factors are: kVp, mA, time, distance.
Factors affecting CT image RAD
Exposure Factors or Prime Factors
IMAGE QUALITY AND ARTIFACTS 1 2 WHY YOU SEE WHAT YOU SEE… The films or images have different levels of density – different shades of gray X-rays show.
RAD 254 Chapter 16 Image Quality Film factors Geometric factors Subject factors.
1 ARTIFACTS: AN UNWANTED DENSITY ON THE FILM
RADIOGRAPHIC ARTIFACTS
PRINCIPLES OF TECHNIQUE AND EXPOSURE
Sensitometry By Prof. Stelmark. The study of the relationship between the intensity of exposure of the film and the blackness after processing is called.
Radiographic Quality Visibility and Sharpness
Image Quality Q&A. RAPHEX Diagnostic Question 2001 D9: The imaging system which is best for visualizing small high contrast objects is: A. Computed tomography.
RAD 354 Chap. 13 Radiographic Technique
Image Production and Evaluation NOTE: QA AND QC ARE USED INTERCHANGABLY IN APPLETON AND LANGE.
FILM CASSETTES & INTENSIFYING SCREENS WEEK 9
RAD 354 Chapt. 16 Image QUALITY
IAEA International Atomic Energy Agency General Radiography Radiation Sources in medicine diagnostic Radiology Day 7 – Lecture 1(1)
Image Receptor Unsharpness By Professor Stelmark.
Lavin: Chapter 7 CTVT: pp
Image Quality and Patient Dose. X-ray tube design - basic principles Electrons generated by thermionic emission from a heated filament (cathode) Accelerating.
Tube Exposure Factors Math Technique Contrast and Density
Sergeo Guilbaud School of Radiologic Sciences
RADIOGRAPHIC QUALITY S. Guilbaud, Education Director School of Radiologic Sciences.
Exposure Factors or Prime Factors
Chapters 21 & 22.
Optimisation of Patient Protection for Radiography
Quality Control Testing of Screen Speed
Resident Physics Lectures
RECORDED DETAIL.
Artifacts and Errors.
Image Production and Evaluation
RECORDED DETAIL.
Fluoroscopic Image Quality Considerations
Dept of Radiodiagnosis, BJMC, Pune
Presentation transcript:

4/30/20151 Presenter:Jitendra Thakur Moderator:Mr.Lalit K Gupta B.Sc.MIT(2007) BPKIHS,Dharan

QUALITY OF RADIOGRAPH  Is the exactness of representation of the patient’s anatomy on the radiograph  The most important characteristics of radiographic quality are sharpness/unsharpness,contrast,resolution,noise,size of image(magnification and distortion) and artifacts.  High spatial and contrast resolution require low noise and slow image receptors 2

4/30/20153

4

Characteristics of Radiographic Quality 4/30/20155 Sharpness/Unsharpness Contrast Resolution Noise Size of image Artifacts

6 1.Geometric(G) a)Focal size b)Focus-object distance c)Focus-film distance 2.Object factor(O) 3.Intrinsic factor(I) a)Grain size of film b)Grain size of I. Screen 4.Movement (M) a)~ of tube b)~ of object c)~ of film 5.Total unsharpness =G+I+O+M Sharpness/Unsharpness (factors)

4/30/ Geometric unsharpness  As penumbra(partial shadows) increases with an increased focal spot size,increased object- to- film distance and decreased focus-to-film distance;the degree of geometric unsharpness increases. Geometric unsharoness=FOD/FFD×Focal spot size 2.Object factor(o)  X-ray absorption vary across the object due to the shape of the structures in the body.  As most structures in the body have a round edge,the gradual fall-off in absorption towards edge leads to the absorption unsharpness.

4/30/ Intrinsic factor(I) a.Duplitized film produce more unsharpness than single-sided emulsion due to crossing over effect. b.Spread of light will be greater with larger crystals of screen(regular/fast screen) and will be greater with increasing distance between crystals and film(poor film/screen contact) which increases unsharpness. 4.Movement unsharpness(M)  Is due to patient,equipment or film movement during the Expoxure  Can be minimized by using short-expoxure time,small FOD and particularly by immobilization(using various accessories i.e. pads,sand bags,binders,velero staps). …cont..

4/30/20159

10

4/30/201511

4/30/201512

4/30/ Subject contrast Exposure Scattered Radiation Development Image-acquisition device Subjective contrast The observer Viewing conditions Radiographic Contrast Radiographic/Objective contrast Factors Region of body under examination Contrast media Pathology KV[α 1/sbj contrast] Subject Contrast Factors Contrast

Subject contrast Is a feature of the object(subject) under examination. The different irradiation intensities emerging from the spatial distribution of linear attenuation coefficients within the object. Factors affecting sc The region the body under examination Contrast media Pathology –if the density of a structure is changed due to pathology then there will be a change in subject contrast Kv Kv<1/subject contrast 4/30/201514

2.subjective contrast The personal appreciation of the contrast in the image is called subjective contrast. It depends on: The observer :visual perception, fatigue etc Viewing conditions: e.g. ambient lighting 3.Radiographic contrast(objective) Is the difference in OD on different parts of processed film or diff. in computer screen brightness recorded as a result of the range of emergent beam intensities. 4/30/201515

Factors affecting RC Subject contrast Exposure – if too much or too little radiation is used,there may be a reduced range of densities visible on the image, thus radiographic contrast will be reduced or non-existent. Scattered radiation reaching the image receptor –the use of grid lead – backed cassette, lead rubber under cassette,air gap technique ;may reduce scatter radiation reaching IR which improve radiographic contrast. Development – to achieve optimum RC,careful control of factors such as developer temperature, development time and processing chemical activity is needed. Image acquisition device – the design and function of the device used to acquire the image such as certain types of film emulsion,intensifying screen and phosphor plate,software in digital system can have profound effect on contrast. 4/30/201516

Resolution The ability to demonstrate closely spaced structures in the subject as separate entities on the image. It depend on contrast,unsharpness, noise and speed. Noise The random fluctuation in the OD of the image 3 kinds of image noise Fog-due to the presence of scattered radiation Quantum noise –due to quantum nature of x-ray beam Electric noise –due to limitations in electronic processing of the image 4/30/201517

Tools for improved radiographic quality  RT normally has the tools available to produce high –quality radiograph  For any given radiographic examination, a proper interpretation and application of following factors must be available : Patient positioning  The anatomical structure under examination must be close to IR  CR should be incident on the centre of the structure  The patient must be effectively immobilized to minimize motion blur 4/30/201518

Image receptors In general,extremity and soft tissue,a fine detail screen film combination is used Most other radiographs use double emulsion film with screens The new,structured- grain x-ray films used with high resolution intensifying screens produce exquisite images with limited patient dose Selection of technical factors Before any examination,RT must select the optimum radiographic technique factors :KVp, mAs and exposure time Image quality is improved with short exposure with the use of three- phase and high frequency generators as result of reduced motion blur Adding filtration reduces the beam intensity but increases the quality Different types of grids are used to improve image contrast 4/30/201519

4/30/201520

Image artifacts  Are undesirable optical densities or blemishes on a radiograph or any other medical image  Can interference with anatomical structures and lead to misdiagnose Processing artifacts Emulsion pickoff Gelatin build up Curtain effect Chemical fog Guide shoe marks Pi-lines Wet pressure sensitization Diachronic stain 4/30/201521

Exposure artifacts Motion Improper pt positioning Wrong screen film match Poor screen contact Double exposure Warped cassette Improper grid positioning Handling and storage artifacts Light fog Radiation fog Static Kink marks Hypo retention stain Scratches 4/30/201522

4/30/201523

Size of image Magnification If FOD is increased,FFD should increase to reduce magnification Magnification =image size /object size =FFD/FOD Image distortion A distorted image will produced if not all parts of the image are magnified by the same amount 4/30/201524

4/30/201525

References Clark’posotioning in radiography Radiological science for technologists Encyclopedia of radiographic positioning internet 4/30/201526