Course # W 51 HVAC Motor Control Solutions Presenter: John Polites - Automation Engineer Wednesday, May 3 rd - 9:00 AM – 10:00 AM State College Room Topics.

Slides:



Advertisements
Similar presentations
Variable Frequency Drives Bypass Options
Advertisements

Trane Voyager™ rooftop units
Setup/Installation/Operation of an Environmental Control Unit (ECU)
Welcome Using Variable Speed Drives to Save Energy. Dan Reilly June 22 nd 2010.
Learning Outcomes Upon completion of this training one should be able to: Identify open loop and closed loop campus-type hydronic water system applications.
Variable Frequency Drives Energy Savings Applications & Benefits National Grid-NYSERDA Upstate NY Commercial Industrial Efficiency Expo March 30, 2010.
Efficient Management for Building Automation. Market Trend.
HVAC & WATER Application note
SmartVFD HVAC and BYPASS Introduction. 2 Smart Technology to Reduce Electricity Consumption “Today, our continuing progress is restricted…not by the power.
Variable Frequency Drives VFD Basics
Upon completion of this training one should be able to: Identify different types of hydronic heating systems Identify key components in a simple hydronic.
Engineer Presentation
Energy Saving DDC Control Strategies
Lindab Pascal - Simplified VAV solution with full potential...
Application Types Variable Torque Constant Torque.
© Belimo University 2011, All Rights Reserved
WISA Meeting Help Arrange a Speaker, Write Bio, Introduce
Chapter 8 Output Modules.
Make the most of your energy Make the most of your energy SM Add photo in this area Chicago Advanced Energy Stakeholder Series 2014 Mike Mattingly Oct.
Refrigeration and Heat Pump Systems Refrigeration systems: To cool a refrigerated space or to maintain the temperature of a space below that of the surroundings.
EPANET FOR PRESSURIZED PIPE SYSTEMS
Motor Starting Technologies
Considerations for Selecting VFD’s Quentin Nesbitt, PE Agricultural Engineer Idaho Power Company.
An intelligent VAV zoning system
Static Pressure Control Loop The purpose of the static pressure control loop is to maintain an optimal static pressure in the ductwork. The control loop.
© American Standard Inc Fan Pressure Optimization The Trane Company.
Motor Start Theory ME00107A.
New England Association Of Fire Protection System Designers Rick Dumont.
1 Multi-use Facility. 2 Occupancy – 140 persons Building Characteristics Single story 20,000 square feet (250’ x 80’) Standard construction.
Grundfos FLOW THINKING Air conditioning the Grundfos Way.
Important variables Water: Air: Conversion:
TEAM UP! FOR FAN AND PUMP SAVINGS It can be as easy as replacing an old drive belt.
1 Medical Office Building. 2 Occupancy – 400 persons 8 a.m. – 5 p.m. Monday - Friday Building Characteristics Three stories 40,000 square feet (200’ x.
Confidential / Property of Danfoss Drives A/S DKDD-SMC 1 Drives Division Danfoss presents - VLT ® 2800 Series.
automation 4 me TYPES OF LOAD 1 automation 4 me CONSTANT TORQUE LOAD : PERCENT SPEED NOTE:- A CONSTANT TORQUE LOAD IS NOT NECESSARILY 100% LOAD TORQUE.
MCS’S MAGNUM DIAGNOSTICS PACKAGE Visit us at
Variable Frequency Drives and Irrigation Pumps Stefanie Aschmann Bozeman, MT 11/30/11 1.
VS mini J7 COMPACT INVERTER FOR GENERAL USE
COMPACT Variable Frequency Drives. Honeywell Proprietary Honeywell.com  Buildings Consume Massive Amounts of Energy Commercial Buildings consume massive.
N O R T H A M E R I C A C O M M E R C I A L TDP
YASKAWA VS-606 V7 COMPACT VECTOR - CONTROLLED INVERTER FOR GENERAL USE 230V (Single-Phase).1Kw ~ 3.7Kw (.13HP ~ 5HP) 230V (Three-Phase).1Kw ~ 7.5Kw (.13HP.
Control Theory Control System Objectives  Establish a final condition  Provide safe operation  Eliminate the human element  Assure economical operation.
Learning Outcomes Upon completion of this training one should be able to: Identify hydronic chilled water system applications. Define the difference between.
Introduction to Energy Management. Week/Lesson 10 Air Moving Equipment: Fans and Ducts.
Introduction to Energy Management. Week/Lesson 12 Advanced Technology for Effective Facility Control.
CUE – Make Any Pump an E-Pump
Variable Speed Applied to Pumps. Life Cycle Costs - Courtesy of Hydraulic Institute and Europump Initial cost is not the only cost associated with a pump.
the compact air control solution
1 Hospital Building and Campus Piping. 2 Hospital Building Occupancy – office and patient areas Patient areas: 24 hours per day Office areas: 8 am – 5.
Introduction to Energy Management. Week/Lesson 13 Control Strategies for Occupant Comfort.
Learning Outcomes Upon completion of this training one should be able to: Identify hydronic chilled water system applications. Define the difference between.
7/15/2002PP.AFD.09 1 of 43 Yaskawa Electric America Variable Frequency Drives In HVAC Applications.
 2008 Kaeser Compressors, Inc., USA (V4.1) SFC Product Introduction “Specifications are subject to change without notice” 1 SFC Sigma Frequency Controlled.
Elements of Electrical Design HASMUKH GOSWAMI COLLEGE OF ENGINEERING
Kaeser Direct Drive CSD Rotary Screw Compressors
Copyright 2011, Toshiba Corporation. Toshiba International Corp - Houston Tx Jim Hartzel Section Mgr - Water / Waste Water Business 20 Yrs Field Service.
CNC FEED DRIVES.
It’s…….
Energy Efficient Motors and Variable Speed Drives
Design, Evaluation and Application of a Fuel Cell Vehicle
The New C55* CPVSd 10-20hp People. Passion. Performance.
Speed control of three phase induction motor
Variable Frequency Drive Savings Calculator Tools
SPOC Automation and BECI- who are we?
Energy Efficiency in District Coiling System
Engineering Presentation
VITALITY Large Splits Johnson Controls PowerPoint Guidelines | July 21, 2009.
Presented by Mike Zacharias
Presentation transcript:

Course # W 51 HVAC Motor Control Solutions Presenter: John Polites - Automation Engineer Wednesday, May 3 rd - 9:00 AM – 10:00 AM State College Room Topics of Discussion: –Motor Load & Starting Methods –Motor Control for HVAC Applications –Energy Savings with Variable Frequency Drives –Introduction to PF400 HVAC Drive

AC MOTOR LOADS

–Constant Torque –Variable Torque –Constant Horsepower AC Motor Load Types

Constant Torque Motor Loads

Variable Torque Motor Loads

Typical of Centrifugal Pumps and Fans Pumps: Hot Water, Chilled Water, Condenser Water, Distribution Fans: Supply, Return, Relief, Exhaust, Cooling Tower Fans Torque and Horsepower Drops As Square of Speed Reduction; Excellent Potential for Energy Savings with a VFD versus a throttling Valves, Dampers or Inlet Vanes Variable Torque Application Types

Two Pump Types: Positive Displacement Pumps Move fluid chamber to cause fluid to flow Constant Torque Load Profile Centrifugal Pumps Move fluid by rotation of an impeller Variable Torque Load Profile Hydronic Pumps: Hot Water, Chilled Water, Condenser Water & Distribution HVAC Pump Types

Components of the Pump System Pump Motor Coupling Base Plate Piping Valves Inlet Source –Above Pump –Below Pump Discharge Static Head

Pump Type and Applications

HVAC Systems

The purpose of an HVAC (heating, ventilating, and air-conditioning) system is to provide and maintain environmental conditions within an area called the "conditioned space." The commercial system selected for a particular application should endeavor to provide the optimum environment for employee comfort and productivity, process function, and good indoor air quality with energy efficiency and cost-savings HVAC Systems

Air Handling Systems –Air Handling Units (AHU), Rooftop Units (RTU), Makeup Air Units (MUA), Exhaust Fans (EF), Variable Air Volume Boxes (VAV),,fan unit (FU) Hydronic Systems –Chilled Water (CHW) – [Chillers and Pumping Packages] –Condenser Water (CW) – [Cooling Towers] –Hot Water (HW) - [Boilers and Pumping Packages] Building Automation System (BAS) –HVAC Controls, Direct Digital Controls (DDC), Energy Management System (EMS), Facility Management System (FMS) Types of HVAC Systems

HVAC Motor Control (Starters or VFDs) Typical Commercial HVAC Systems

Supply fan will be controlled by PF400 Controllers measure Static Pressure and send speed signals to both VFD’s VAV boxes located in each room distribute conditioned air Return fan will be controlled by PF400 Traditional Variable Air Volume (VAV) Air Handling Unit

These motors are controlled by a Variable Frequency Drive Variable Frequency drives Replace the wasteful Check valve system Chilled Water Pumping System

Valves replaced when drives are used Motors controlled by VFD’s in new applications Condenser Water Pump System

Building Automation Systems (BAS) > Controllers Send Output Commands to VFDs and Motor Starters: Start/Stop Control & Speed Commands > Run/Fault Commands Sends Status Commands for Starter Device to Controllers.

A pressure sensor within an air duct or pipe measures the system pressure As the pressure changes an analog signal is sent to the BAS The BAS sends a start stop and speed command to variable frequency drives (VFDs) or motor starters When valves and dampers close, the pressure rises in the ducts or pipes, which reduces the speed Basic BAS Systems Control Strategies

This is a typical view on a building automation computer screen showing the status of various points in an air handling system Building Automation System Graphic

Motor Starting Methods

Full Voltage Starting Reduced Voltage Starting –Wye - Delta Starters –Autotransformer –Soft Starters Variable Frequency Drives Types of HVAC Motor Starting Methods SMC- Flex

Full Voltage Starting Full Voltage Starting Characteristics –Contacts close immediately supplying full line voltage to motor. Advantages: –Lowest starter cost –Simple starter designs Easy to maintain and troubleshoot Disadvantages: –Inrush Current 6-10 times rated running current Issue when peak demand charges are enforced by utilities –Initial Torque Mechanically hard on system Reduced life of belts, gears Disconnect Fuses Contactor Overload Relay L1L2L3 T1T2T3

NEMA Rated  Serviceability  Contacts Replaceable  Flexible Overload Selection Emphasis on: IEC Rated Emphasis on:  Replacement  Contacts only replaceable on large sizes only  Conserve panel space  Class 10 Overload Protection IEC & NEMA Motor Starters

SMC-Flex Use SCR’s to ramp voltage supplied to motor over a user defined time period Advantages: Reduces inrush current Reduces starting torque Reduces mechanical stress on motor & loads Solid State Soft Starters

Reducing the Voltage Reduces the Current Reduction In Torque!! LRT 100% 0 Percentage of Full Speed (.5) 2 =.25 or 25% Soft Starter Speed Torque Curve

Manual Starters Range Overview –1HP, 115, 230, 277 VAC –0.75 HP, 115/230 VDC –1 or 2 Pole –Thermal Overload Ideal for small Fan and Pump Applications Commercial OEM Products

Adjustable Speed Drives

Solid State AC Variable Frequency = Variable Speed AC Motor DC Bus AC Input Fixed Frequency Inverter Converter AC Output Variable Frequency Variable Frequency Drives Basics Benefits Solid state technology Wide control options Small size power units Good efficiency Lower cost, smaller motors Retrofit existing motors Bypass capability VoltageHertzMotor RPM Base Voltage Base FrequencyV/Hz

To improve process control though speed and torque control To improve system efficiencies To extend life of equipment by reducing mechanical stress To Achieve Energy Savings on Fan and Pump Applications To meet the ASHRAE Energy Standards –Variable flow control on fan & pump systems Why Should I consider using a Variable Frequency Drive (VFD)?

Integral RS485 Communications Supports DSI Accessories Integral LCD Keypad Optimized for Commercial Fan and Pump Applications Stand-Alone Application Specific Features for Fans and Pumps Rated for Variable Torque Loads Packaged Allen Bradley PF400 HVAC Drive

Ratings – V, kW (3-50 Hp) – V, kW (3-150 Hp) 110% Overload for 60 seconds Enclosure –IP20 / UL Open 3-10 HP (240V AC) & 3-20 HP (480V AC) –IP30 / NEMA 1 / UL Type HP (240V AC) & 3-20 HP (480V AC) (with optional kit) HP (240V AC) & HP (480V AC) Environment –IP20 rated for 50 ° C –IP30 rated for 45 ° C PF400 Ratings

Main Input Disconnect 3 Contactor Full Feature Bypass with Disconnect 3 Contactor Basic Bypass with Disconnect Allen Bradley PF400 HVAC Drives Standard VFD

Configurable Keypad with local – remote start/stop and speed controls Compatible with Building Automation System Inputs/Outputs (Start/Stop, Speed and Feedback) Standard BAS Communications: –RS485, Modbus RTU, Johnson Controls N2 & Siemens P1 Future Communications: –Lonworks & Bacnet Process PI Inertia Ride Through Power Loss Flying Start S Curve, Accel & Decel profiles V/Hz Control Motor Overload protection Communication interfaces to Building Automation Systems Analog & Digital inputs & outputs Manual Bypass Capabilities Purge Start Input and Frequency Fire/Freeze Stat Interlock Inputs Variable Frequency Drive Control Capabilities Analog Output Dip Switches Analog Input Dip Switches 24V DC Source/Sink Relay OutputsAnalog and Discrete Wiring RS485 Ports

Starting Method % Voltage at Motor Terminals % Motor Starting Current% Line Current % Motor Starting Torque Lock Rotor Current Full Load Current Lock Rotor Current Full Load Current Lock Rotor Current Full Load Current Full Voltage Autotrans. 80 % tap % tap % tap Part Winding Star - Delta Solid State Variable Frequency Drive Motor Characteristics with Different Starting Methods

HVAC Motor Control Price Comparison Motor HPVFDSoft Starters NEMA Combination Starters IEC Combination Starters 5 $ 900 $ 1,100 $ 780 $ $ 1,000 $ 1,200 $ 813 $ $ 1,600 $ 1,195 $ $ 2,700 $ 2,400 $ 1,959 $ 1, $ 3,400 $ 2,800 $ 1,975 $ 1,513 Standard Features: 480 VAC, 3-Phase NEMA 1 Enclosure Input Disconnect Switch Motor Thermal Overload Protection

ENERGY SAVINGS WITH VFDs

Centrifugal Pump Energy Savings There are two methods used to accomplish the continuously varying flow: One method is throttling which changes the system curve by use of control or throttling valve. The other method is to vary the speed of the pump which modifies the pump curve. Building Automation System controls the pump starter or VFD and control valve based on HVAC sequence of operation.

Typical Pump Curves Pump Curves Throttled with Control Valves Pump Curves Controlled by a VFD Energy Savings with VFD’s (GPM Proportional Brake HP-Torque) Centrifugal Pump Energy Savings

Many air handling systems require operation at a wide variety of points. There are several methods used to modulate or vary the flow (or CFM) of a system to achieve the optimum points. These include: Cycling – As done in home heating systems. This produces erratic airflow and is unacceptable for commercial or industrial uses. Outlet Dampers – Control louvers or dampers are installed at the outlet of the fan. To control airflow, they are turned to restrict the outlet, which reduces the airflow. Variable Inlet Vanes – by modifying the physical characteristics of the air inlet, the fans operating curve is modified which changes the airflow. Variable Frequency Drives – By changing the actual fan speed, the performance of the fan changes producing a different airflow. Typical Fan Curves Fan Energy Savings Building Automation System controls the fan starter, control dampers and air system sensors based on HVAC sequence of operation.

Fan Curves with Outlet DampersFan Curves with Variable Inlet VanesFan Curves with VFD Fan Energy Savings

Sample Fan Energy Savings Report Energy Savings Software –( Energy Savings Report –VFD Specs –Energy Savings Calculations –Energy Savings Summary

VFD Energy Savings Software Tools

Schaedler Yesco Distribution HVAC Market

Plan & Spec Market –New Construction, Additions and Renovations –Track projects online through Harrisburg Builders Exchange –Mechanical plans/spec takeoffs for motor control that’s furnished by the HVAC contractor –Application coordination with mechanical equipment specs, building automation system sequences of operations and electrical power system plans Retrofit Market –Provided electrical energy solutions/products to Design/Build and Energy Service Teams i.e.: Variable Frequency Drives and Lighting Retrofit Solutions –VFD Fan or Pump Energy Savings Reports –VFD Replacement Program Schaedler Yesco Distribution - HVAC Market

Local Central PA Support with (5) Staffed Motor Control Specialist Product Guide Specifications & Submittal Packages Certified VFD Startup –VFD Checklist and Reports Onsite Training Available Spare Parts 24/7 Emergency Service Online Allen-Bradley Drives Technical Support – Motor Control Support

Questions ?