Akira Yamaguchi Professor of Health & Human Habitation Harvard School of Public Health Indoor Environments John D. Spengler, Ph.D. E-119 November 9, 2010
Indoor Environmental Quality in Buildings
Commercial Building Energy Use Energy Future. American Physical Society (2008) LIGHTING 27% Space Heating 15% Space Cooling 14%
Sick Building Syndrome (WHO, 1983) Diagnosis of SBS requires demonstration of an elevated complaint or symptom prevalence that is associated with a particular building, and that symptom patterns do not match other clinically recognized syndromes.
Terminology Sick Building Syndrome –Symptoms linked to building –Resolve when not in building –Effect a substantial fraction of occupants
Sick Building Symptoms Dry, itchy eyes Nasal irritation Hoarseness, irritated throat, laryngitis Skin problems Fuzzy thinking, memory Irritability, sleep disruption, fatigue Headaches, nausea
Potential Building Related Illnesses Contagious Diseases –Influenza –SARS –Common cold (HRV) –Measles –Chicken pox –TB Environmental –Legionnaires –Humidifier fever –Asthma –CO poisoning –Nitrogen Dioxide –Pesticide poisoning –Lung Cancer Radon, asbestos, ETS
Triggers of IAQ Concerns Odors, drafts, temperature, humidity Water intrusion Dust, particles Vibrations, visual changes, new equipment, alterations, maintenance Management stresses, labor issues, personal agendas Rumors
Sustainability Guidelines Partially Address Health Low VOC’s Ventilation Commissioning CO 2 monitoring LEED and BREEM have IEQ credits
IAQ and Building Costs Labor$200 / square foot Financing $ 20 / square foot Energy$ 2 / square foot Cleaning$ 1 / square foot
How Sustainable Buildings Could Improve Health & Productivity Sustainable Buildings Superior Work Performance Economic Benefits Better Health Reduced Health Care Costs Less Absence Thermal state Hearing & concentration Vision Attitude Mental performance Improved Indoor Environmental Quality Better design, construction, commissioning & O&M W. Fisk, LBNL, White House Conference, Jan. 2006
New construction methods and new materials
Molds and chemical indoors
Rooftop HVAC System
Air Handling & Conditioning Source: EPA
Complex Roof Top
Standing Water
School Unit Ventilators
Re-entrapment
Air Intakes
HVAC Filters
Large Filter Banks
Mixing Chamber
Condensate Drip Pan
Scaling from Drip Pan and Slime Mold
Dirty coils and energy loss
Air Conditioning (AC) Link to Increased SBS Symptoms in Offices Source: Seppanen and Fisk, Indoor Air Journal 2002 Type of ventilation system = Significantly more symptoms = Reference Group = Same #
Renewed Interest in UVC
Ventilation Ducts
Fiberglass Lined Ducts
Cleanliness of air handling systems – potential explanation The air handling system is a source of sensory air pollution in buildings Every component seems to generate pollution (European Airless Project 2001) –filters, coils, ducts
Dirty Ducts
Fiberglass Soundproofing
Rodent Nest
Adequate Air Mixing
62 office printers were investigated for ultra-fine particle Emissions in typical open office space. 4 classes: none emitters, low emitters, medium and high Emitters 60% no or low emitters 13% medium emitters 27% high emitters
P/cc 100,000 10,000 1,
Supply Register
Ventilation cfm / person cubic feet per minute per person – or – l / s – p liters per second per person Fresh Outside Air – delivered indoors
Ventilation Requirements 1.5 cfm / person – O 2 demand 2.5 cfm / person – CO 2 dilution 5 cfm / person – old energy standard 10 cfm / person – people without sources
Minimum Ventilation Rates Source: EPA
ASRAE 62 Standards was 5cfm/p cfm/p but 15cfm/p with smoking cfm/p assumed smoking cfm/p excluded smoking separate residential stnd.
Ventilation Guidelines Minimum –15 cfm / person Office –20 cfm / person Smoking –60 cfm / person
The Evidence for Ventilation: Major Points Higher ventilation rate (higher rate of outdoor air supply) is associated with objectively measured improvements in work performance Higher ventilation rate is associated with reduced respiratory illness, less absence, and reduced sick building symptoms W Fisk, LBNL
Performance relative to performance with 6.5 L/s-person (13 cfm/person) Current minimum for offices in most codes Classroom code minimum L/s-p cfm/p 0 Seppanen, Fisk, Lei-Gomez (Indoor Air Journal 2005)
An example of data on ventilation and short term sick leave Short term sick leave 12 L/s 24 L/s per person 1.16 % 1.96 % 1.6 days per year (Milton et al. 2000) 24 cfm48 cfm per person 40 buildings in study
Even in Green Schools Ventilation can be Inadequate
The Evidence for Temperature: Major Point High and low temperature is associated with objectively measured decrements in work performance
Source: Statistical analysis of research data from 24 studies relating temperature with objectively measured work performance outcomes Seppanen and Fisk (2005) Relative Work Performance vs. Temperature (maximum performance at at 21.8 o C, 72 o F )
Acceptability of Indoor Air
CRT of PC Build. mat. Carpet 0.8% per 10% in PAQ Perceived Air Quality and Performance Bako-Biro, DTU Ph.D. Thesis, 2004 TEXT TYPING
Top Ten Characteristics of a Healthy Building Dry Clean Ventilated Thermal control Acoustic quality Glare control Odor control Air quality –VOCs –Biologicals –Ozone –Particles Space equity Manage workplace stress