STUDOR ® STUDOR ® AUSTRALIA Presents The Introduction & Installation Course for the STUDOR ® Mini-Vent  Air Admittance Valve (AAV)

Slides:



Advertisements
Similar presentations
Plumbing.
Advertisements

Sectional Assembly and Installation
Typical Plumbing System
HEATING AIR © Commonwealth of Australia 2010 | Licensed under AEShareNet Share and Return licence.
Unit 206: Domestic hot water systems
Agricultural Mechanic and Technology Cluster
1 HVACR316 – Piping Tubing and Piping. 2 Purposes of Tubing and Piping Provides a path for refrigerant to take Provides a means to return oil to the compressor.
PB - Dialysis Review1 DIALYSIS MACHINES REVIEW OF PLUMBING INSTALLATION REQUIREMENTS.
Waste Pipe from Bath The waste pipe from the bath should be a minimum of 40mm in diameter, it can be 50mm in diameter if there is a longer run of pipe.
HVACR316 - Piping Piping and Fitting.
Service Technician Training
Lesson Working with Copper Tubing. Interest Approach n Why is copper tubing only used for water and fuel lines?
Metering Pump Spare Parts Replacement. Pump Components (Metering Pump) Pumps are supplied with a 120VAC or 240VAC power cord. Use care to ensure pump.
Household Waste Drainage Systems
Unit 205: Cold water systems
Objective of the session.
Chapter 20 Plumbing Plans.
Understanding and Designing Plumbing Systems
TUBING AND PIPING.
Water Sensitive Plumbing And Sanitation BY:DINESH MUTHA Downloaded from CivilDigital.comCivilDigital.com.
Unit 204: Common plumbing processes
Plumbing Systems CNST 305 Environmental Systems 1 Dr. Berryman
Screened Warning Pipe A screened water pipe is a requirement under the water regulations. The pipe should be one size larger that the supply pipe.
 Determine the waterline components needed to complete the water supply for the bathroom shown in figures 13-6 and 13-7.
Condensation Piping and Installation Drain Pans
Skilled Trades 1201 Residential Plumbing.
Unit 206: Domestic hot water systems
New Mexico FFA Agricultural Mechanics Career Development Event Plumbing.
STUDOR® AUSTRALIA Presents
Presentation on Installation of a Domestic Cold Water Storage Cistern
Fuel Oil Systems Fuel Oil Systems consist of: Storage Tanks Pumps
Hydronic Mechanical Controls
© Goodheart-Willcox Co., Inc. Permission granted to reproduce for educational use only Warm-up 4/6/15 What type of water do you have at your house? Objective:
Screened Warning Pipe A screened water pipe is a requirement under the water regulations. The pipe should be one size larger that the supply pipe.
SEWER PIPING DESIGN Sewer piping differs from water piping, in that sewer pipes are not under pressure. The function that takes place inside sewer pipes.
Outcome 3 (part 2) Heat emitters and their components Unit 208: Central heating systems.
RESIDENTIAL AIR HANDLERS
STUDOR® AUSTRALIA Presents Active Venting System Design Utilizing STUDOR Air Admittance Valves and Positive Air Pressure Attenuators (As per AS/NZS
INSTALLATION & COMMISSIONING. 5WSS Installation Hanging the Unit Hanging the Unit Location Considerations Location Considerations Refrigerant Piping Refrigerant.
HVAC523 Piping and Fittings.
Contributed by: Integrated Teaching and Learning Program, College of Engineering, University of Colorado at Boulder.
Specification & Installation pitfalls “Getting it right to ensure safe drinking water”
Plumbing Theory. DWV System The DWV Drain-waste- vent system in plumbing a system that removes sewage and greywater from the house/building and it also.
1 HVACR316 - Piping Copper Tubing and Fittings. 2 Tubing & Fittings No matter what piping material is used in the installation of an air conditioning.
PLUMBING VENTS A vent is simply described as a device that can take unwanted air from one place and deposit it somewhere else, usually outside. A plumbing.
1 HVACR316 - Piping Copper Tubing and Fittings. 2 2 Safety Refrigerant cylinders should be stored and transported in the upright position to keep the.
CON 4003/CVE 4073/CVE 5073 Construction Estimating Prof R. V. Locurcio.
 Determine the waterline components needed to complete the water supply for the bathroom shown in figures 13-6 and 13-7.
House Drainage System By- Prajyoti P. Upganlawar
HOUSE DRAINAGE MEHTA ANJANI PRAFULBHAI =
Unit 209: Drainage systems
Unit 209: Drainage systems
Unit 209: Drainage systems
Plumbing Valves.
PLUMBING PARTS Plumbing ensures that a royal flush always beats a full house.
High Density Polyethylene Pipe and Fittings
Mahatma Gandhi Institute Of Technical Education & Research centre ,Navsari. A presentation on House Drainage Subject :- Environmental engineering.
Pumped Discharge. Brian Makin 14/
Approximate activity space required
Heating Ventilation and Air Conditioning
Plumbing.
PLUMBING APPLIANCES & COMPONENTS
Typical Plumbing System
Hot water Systems Heaters.
Hot Water Systems Cylinders and Systems.
Cisterns and Insulation
Heating Ventilation and Air Conditioning
Thank You For Purchasing Coeur Designs 11” Shower Extension
Educational Technology
Presentation transcript:

STUDOR ® STUDOR ® AUSTRALIA Presents The Introduction & Installation Course for the STUDOR ® Mini-Vent  Air Admittance Valve (AAV)

The Course: should at its’ completion enable the participants to: 1.correctly identify the components of the Mini-Vent Air Admittance Valve (AAV); and 2.correctly install a Mini-Vent AAV The Assessment : will be via a written Question & Answer Sheet at the end of the course (Participants are advised to make note of items marked with a ‘*’)

The STUDOR Mini-Vent *A device that allows venting of sanitary fixtures (toilets, basins, sinks, baths, etc) without the need to extend vent piping through walls or roofs to outside atmosphere

The STUDOR Mini-Vent Is guaranteed for the life of the plumbing system to which it is attached! Every Mini-Vent has been tested twice before dispatch!

The STUDOR Mini-Vent Now fixtures such as sinks, basins, baths, laundry tubs, etc can all be vented inside cupboards, vanity units, under floors and counters without making unnecessary holes through walls and roofs Mini-Vent

Important Notes *2.Do not remove the Mini-Vent from its packaging until ready to install This way, the chance of dirt, dust or grit getting into the Mini-Vent is kept to a minimum *1.Always make sure there is at least one open vent on the plumbing line or system that the vent is to be attached to *3.Never install a Mini-Vent where the air is contaminated with solvents, e.g. a spray booth

Important Notes *4.Always ensure when installing any AAV that it is an approved product and has both approval and airflow capacity (l/s) clearly marked on the body of the valve or packaging On the top of the Mini-Vent are the relevant Australian Standards Marking

The STUDOR Mini-Vent POLYSTYRENE PACKAGING TOP FOR INSULATION SLEEVE POLYSTYRENE PACKAGING BOTTOM MINI-VENT ADAPTER

Installation The Mini-Vent as supplied can be installed on 3 different sizes of PVC DWV pipes: *40mm: to suit basins and baths in Australia *50mm: to suit sinks, laundry tubs etc *32mm: Older plumbing systems in Australia and basins etc in NewZealand *The Mini-Vent can be installed up 1000mm (1 metre) below the rim of thefixture it is venting (i.e. the flood level)

32mm DWV push-fit over pipe STUDOR Mini-Vent With adapter 40mm BSP male thread Push-fit into 50mm DWV coupling of fitting socket with adapter Adapter: Top Flange

Installation Mini-Vent as supplied with adapter fitted 50mm DWV coupling or fitting socket Whilst applying even pressure, simply push the Mini-Vent into the coupling or fitting socket up to the top flange of the adapter. Completed NOTE: Gluing is not required nor recommended! Recommended prior to installing the fitting

Installation If all the above is correct, install fitting (with Mini-Vent attached) to waste pipe as per normal * 3 RULES FOR INSTALLATION: Always install the Mini-Vent vertically to the waste pipe Always install in an accessible location with adequate clearance around the Mini-Vent Always ensure at least 100mm of vertical pipe between the Mini-Vent and the pipe it is venting *At least 100mm

Installation *At least 100mm * Maximum of 1000mm (1 metre) A 45 degree junction with a 45 degree M & F bend may also be used

Installation *At least 100mm No connection within 75mm of the trap Between mm maximum horizontal distance from the trap

Installation To attach to a 40mm DWV pipe, discard the adapter A standard DWV female adapter is now used and screwed onto the male threaded Mini-Vent using an approved thread sealant (Teflon tape or similar). Hand Tighten Only. This is then attached to the discharge pipe (If required to be attached to a 65mm DWV pipe or larger, simply reduce the pipe to 50mm and then install as previously using the adapter) *NOTE: If the Mini-Vent is to be installed within a wall cavity, a mesh screen or grill must also be installed next to or as near as practical to the valve to ensure adequate air flow and access 100mm

Installation If installing in an outside or inside area, where there is likely to be extreme temperatures (below 0 degrees Celsius), place the top of the polystyrene packaging over the Mini-Vent toinsulate it after installation

Installation *Through a combination of other readily available adapters & the adapter included, the Mini-Vent can be used on many other materials and sizes of pipes It is important to note that it is the capacity of the valve, not its apparent pipe size that allows it to be fitted to pipes up to 100mm DWV *The Mini-Vent has the capacity to vent up to 10 complete fixtures (toilets, baths, basins, etc) Here, through the use of an adapter, the valve is attached to 50mm hard drawn copper tube

Installation Mini-Vents can also be used for venting groups of fixtures such as washrooms, toilet blocks etc This is called: “Group Venting” *The Mini-Vent has the capacity to vent: 10 complete fixtures or 60 Fixture Units - 1 WC (toilet pan & cistern) = 4 Fixture Units - 1 Basin = 1 Fixture Unit

Group Venting This plumbing ventilation test rig, the biggest in the world, was built by students and staff at Gymea TAFE in Sydney, to prove AAVs were equal to or better than ‘Open Air Venting’ for groups of fixtures This entire rig was vented by just 2 Mini-Vents

Installation (Group Venting) Simply install the Mini-Vent as previously instructed into a 50mm vent pipe when coming off a 100mm DWV common discharge pipe or upstream fixture. (But only rising a minimum of 100mm) *These 50mm vent pipes would be positioned on the common or fixture discharge pipe where previously a complete return to the main stack would begin

Group Venting *Taken from Australian National Standards AS/NZS Common Discharge pipes

Summary We’ve learned that approved AAVs can be used to vent both single and groups of fixtures as well as how to install them in those situations Your Instructor will now hand out a Q & A sheet for you to complete. GOOD LUCK!

Acknowledgements STUDOR Australia would like to thank: -the Teaching and Stores Staff under the guidance of Raymond Jones, Senior Head Teacher of Plumbing, TAFE NSW; -Southern Sydney Institute, Sutherland College (Gymea Campus) for their support and contribution to this module; and -all TAFE teachers nationally STUDOR would also like to acknowledge the continued support offered by Plumbers Supplies Co-operative who provided the materials for this project