Central Venous Line (CVL) AND Central Venous Pressure (CVP)

Slides:



Advertisements
Similar presentations
Sharon /Penny. 1.Review indications for the use of PA catheter with heart failure patients. 2.The difference of the four major types of PA catheters.
Advertisements

SWAN GANZ CATHETERS The flow-directed balloon-tipped pulmonary artery catheter (PAC) right heart catheter.
Advanced Nursing Concepts Part 1: Hemodynamic Monitoring
Catherine Luksic BSN, RN.  Primary infusion  “maintenance infusion”  “continuous infusion” Via gravity Via electronic pump  Secondary infusion  “piggyback”
1 Central venous catheter - use Type of catheter Single double or triple lumen. Single double or triple lumen. Sheaths for insertion of pulmonary artery.
Introduction To The Cardiovascular System Chapter 12: Anatomy and Histology.
Intracranial Pressure Monitoring Definition: pressure exerted by intracranial volume of: 1- Brain 2- Blood 3- CSF Normal ICP: mm Hg. Increased.
Central Venous Catheters and CVP Monitoring Nursing Competency
Arterial Catheters Systemic arterial blood pressure is most accurately measured by placing a catheter directly into a peripheral artery. Peripheral arterial.
Lines and Tubes.
Arterial Blood Sampling Also known as Arterial Blood Gas Sampling. ABG.
Venous Pressure. Venous Pressure generally refers to the average pressure within venous compartment of circulation Blood from all the systemic veins flows.
Infusion Therapy.
CENTRAL VENOUS CATHETERISATION.
Central Venous Catheterization UNC Emergency Medicine Medical Student Lecture Series.
Central Line Removal Competency Assessment for Registered Professional Nurses in the Critical Care Areas References: AACN Procedure Manual for Critical.
Pulmonary Artery Catheter
5/24/ HEMODYNAMIC MONITORING. OBJECTIVE 5/24/ Describe the three attributes of circulating blood and their relationships. 2. Identify types.
HEMODYNAMIC MONITORING NUR 351/352 PROFESSOR DIANE E. WHITE RN MS CCRN PhD (c)
Pulmonary artery Balloon (swan Ganz)
CENTRAL VENOUS PRESSURE LEARNING OUTCOMES By the end of this session the student should be able to : Explain the indications for a patient requiring.
Suture Materials ABSORBABLE: lose their tensile strength within 60 days. NON- ABSORBABLE:
Lumbar Puncture: Indications and Procedure
Hemodynamic Monitoring Part I (ABP, CVP, Ao)
CENTRAL LINES AND ARTERIAL LINES
Hemodynamics Is defined as the study of the forces involved in blood circulation. Hemodynamic monitoring is used to assess cardiovascular function in the.
7- Intravenous (I.V) Infusion
Central Venous Pressure and Central lines
Right Internal Jugular Central Vein Catheterization A Course for Emergency Department Rotators Updated 11/3/11 M Zwank, MD.
Advanced IV Access.
INTRAVENOUS TECHNIQUES 1.To understand the proper indications for central intravenous access 2.To know how to perform central intravenous techniques during.
Hemodynamic Monitoring By Nancy Jenkins RN,MSN. What is Hemodynamic Monitoring? It is measuring the pressures in the heart.
Intravenous cannulation
PRPEARED BY : SALWA MAGHRABI CLINICAL INSTRUCTOR
Prepared by: Salwa Maghrabi Teacher Assistant Nursing Department Arterial Blood Gases.
1 © 2013 Cengage Learning. All Rights Reserved. May not be copied, scanned, or duplicated, in whole or in part, except for use as permitted in a license.
Arterial Blood Gases ABG. DEFINATION  An arterial blood gas (ABG) is a blood test that is performed taking blood from an artery, rather than a vein.
Originally Created By: Sheila Elliott MN, RN Revised By: Tina Haayer, RN, BScN.
Central Venous Access. Indications Peripheral access impossible. Administration of irritant medications inc. TPN. Measurement of mixed venous oxygen saturations.
1 Arterial Lines Set Up & Monitoring Union Hospital Emergency Department.
Care of patient with CVC
Implanted Ports: Procedure for Access and Care
Chapter 16 Assessment of Hemodynamic Pressures
Central Venous Access Module. Approach Two approaches are commonly used and will be described: 1.Right internal jugular vein 2.Right sublclavian vein.
Done by : Salwa Maghrabi Teacher assistant Nursing department
Copyright © 2008 Lippincott Williams & Wilkins. 1 Assessment of Cardiovascular Function Hemodynamic Monitoring.
PCI What You Need to Know!. What and Where Radial- advantages  Immediate ambulation  Easily compressible vessel  Less risk of nerve injury  Dual blood.
Infusion Therapy.
Management of shock -Urgent resuscitation is needed to prevent the mother's condition deteriorating and causing irreversible damage. - Women who decline.
CENTRAL LINES AND ARTERIAL LINES
Cardiac Cath and Angiocardiography Adult II FINAL 2/2015.
Central Line placement
Venous Pressure 1.
Arterial Line. Outline Definition. Indication Contraindication. EQUIPMENT Arterial Sites Nursing Skills Standard.
Intravenous cannulation
Hemodynamic Monitoring John Nation RN, MSN Thanks to Nancy Jenkins.
Central Lines Dr. Peter Jones Emergency Medicine Specialist.
Arterial Blood Pressure(ABP) Arterial Blood Pressure(ABP) Central Venous Pressure(CVP) Central Venous Pressure(CVP) Pulmonary Artery Pressure(PAP) Pulmonary.
Skills Lab MS II Charnelle Lee, RN, MSN.
Central Venous Access Venous Devices
HEMODYNAMIC MONITORING
HEMODYNAMIC MONITORING
Pulmonary Artery Pressure Monitoring
9/11/2018 Basic principles of advanced hemodynamic monitoring in anesthesia and ICU Marta Zawadzka 1 1.
Cardiac Cath NUR 422.
Venous Pressure 1.
Central Lines CVC-Central Venous Catheters
INVASIVE PRESSURE MONITORING
Presentation transcript:

Central Venous Line (CVL) AND Central Venous Pressure (CVP) Fadi Jehad Zaben RN MSN IMET2000, Ramallah

Learning Outcomes: Describe the sites of central venous catheterization. Understand why central venous pressure monitoring is performed. Demonstrate how to perform central venous pressure monitoring using a manometer and a transducer. State normal parameters for CVP.

Introduction: The central venous pressure reflects the right atrial pressure (RAP) and is similar to measuring the JVP clinically. Central venous pressure measurement is often associated with intensive and critical care settings. Circulating blood flows into the right atrium via the inferior and superior vena cava. The pressure in the right atrium is known as central venous pressure (CVP). Critically ill unstable patients may need hourly measurements of CVP.

TYPES OF CENTRAL LINE: SINGLE LUMEN DOUBLE LUMEN TRIPLE LUMEN QUADRUPLE LUMEN QUINTUPLE LUMEN

Single, Double, and Triple Lumen Central Lines

Indications Central Venus Line (CVL): Need for IV access and failure of peripheral access Peripheral access too painful or very difficult Long term IV access anticipated Infusion of drugs which may cause peripheral problems e.g. vasoconstriction, phlebitis Hemodynamic monitoring Volume resuscitation with large bore central lines CVP measurement, Rt atrial pressure To obtain frequent blood sample To determine how much fluid is needed in 24 hr Insertion of a pacing wire.

Relative Contraindications: Bleeding disorders (platelet counts <50,000, bleeding is uncommon and easily managed). Anticoagulation or thrombolytic therapy. Combative patients. Distorted local anatomy. Cellulitis, burns, severe dermatitis at site. Vasculitis.

Sites for insertion of CVL: Internal jugular. Subclavian. Femoral vein. Brachial vein for long lines.

Factors Affecting the CVP: Systemic vasodilatation and hypovolaemia, which leads to reduced venous return in the vena cava and reduced RAP Right ventricular dysfunction and pulmonary hypertension leads to raise right atrial pressure, as does tricuspid and pulmonary stenosis.

Advantages Versus Disadvantages Of Sites for insertion of CVL:

Continue……

Normal CVP Measurements: The normal CVP is between 5 – 10 cm of H2O or (2-5) mmHg. It increases 3 – 5 cm H2O when patient is being ventilated.

Increase of CVP: CVP increased in the following conditions: Over hydration. Right-sided heart failure. Cardiac tamponade. Constrictive pericarditis. Pulmonary hypertension. Tricuspid stenosis and regurgitation. Stroke volume is high.

CVP reading is High:

Decrease of CVP: Hypovolemia. Decreased venous return. Excessive veno or vasodilation. Shock. If the measure is less than 5 cm water that mean that the circulating volume is decrease.

CVP reading is Low?

CVL Insertion: Equipment. Patient position. Procedure. After insertion.

Equipment: Sterile gloves, gown, suture pack. Iodine solution. 10 ml syringe, 2% lidocaine, 10 ml N.S. Catheter special size. H2O manometer. Flush solution with complete CVP line. Dressing set.

Catheterization Kits Go over kits and demonstrate procedure with students

Patient Position: Patient is moved to the side of the bed so physician would not lean over. The bed is high enough so physician would not have to stoop over. Patient should be flat without a pillow, Trendelenburg position if patient is hypovolemic. The head is turned away from the side of the procedure. Wrist restraints if necessary.

Procedure: Skin preparation: Prepare before putting sterile gloves Allow time for the sterilizing agent to dry Drape: Large enough and Handed sterilely by the assistant. Hole in the area of placement. Prepare the tray: Prepare the equipment before starting. Anesthesia: Use local anesthesia with lidocaine.

Nursing Role After CVL Insertion: Dispose all sharps. Place an occlusive sterile dressing. Flush lumens to maintain patency. Obtain a chest x-ray (ask for order if physician doesn’t mention it). Monitor site for bleeding. Assess breath sounds. Assess circulation. Assess for hematoma. Document insertion, site, dressing and flushing.

Chest X-ray and CVL

USING THE CENTRAL LINE: Flush q shift, before and after use with NS. Some places also require heparin flush. Close clamps when not is use. Dressing is usually changed every days. Line can be used for blood drawing –withdraw and waste 10 cc, then withdraw blood for samples. If port becomes clotted, do not use – sometimes ports can be opened up.

Immediately Complications of Insertion CVL: Hemothorax. Pneumothorax (most common). Bleeding: More common in patients with coagulopathy“easily control femoral”. Arterial puncture. Vessel erosion: Large vessel perforation “Dialysis”. Nerve Injury. Dysrhythmias. Catheter malplacement. Embolus. Cardiac tamponade.

Delayed Complications: Dysrhythmias Infection “Late, Femoral > IJ > subclavian” Catheter malplacement. Vessel erosion. Embolus. Cardiac tamponade. Thrombosis.

Measuring CVP: There are two methods of CVP monitoring: Manometer system: enables intermittent readings and is less accurate than the transducer system Transducer system: enables continuous readings which are displayed on a monitor.

CVP System:

Phlebostatic Axis: 4th intercostal space, mid-axillary line Level of the atria

CVP Measurement: Line up the manometer arm with the phlebostaticaxis ensuring that the bubble is between the two lines of the spirit level. 2. Move the manometer scale up and down to allow the bubble to be aligned with zero on the scale. This is referred to as 'zeroing the manometer'. 3. Turn the three-way tap off to the patient and open to the manometer.

Continue……. 4. Open the IV fluid bag and slowly fill the manometer to a level higher than the expected CVP. 5. Turn off the flow from the fluid bag and open the three-way tap from the manometer to the patient. 6. The fluid level inside the manometer should fall until gravity equals the pressure in the central veins.

Turn the tap off to the manometer. Continue……. When the fluid stops falling the CVP measurement can be read. If the fluid moves with the patient's breathing, read the measurement from the lower number. Turn the tap off to the manometer. Document the measurement and report any changes or abnormalities.

Using a Transducer: Explain the procedure to the patient to gain informed consent. The CVC will be attached to intravenous fluid within a pressure bag. Ensure that the pressure bag is inflated up to 300mmHg. Place the patient flat in a supine position if possible. Alternatively, measurements can be taken with the patient in a semi-recumbent position. The position should remain the same for each measurement taken to ensure an accurate comparable result.

Continue……. Catheters differ between manufacturers, however, the white or proximal lumen is suitable for measuring CVP. Tape the transducer to the phlebostaticaxis or as near to the right atrium as possible. Turn the tap off to the patient and open to the air by removing the cap from the three-way port opening the system to the atmosphere.

Document the measurement and report any changes or abnormalities. Continue……. Press the zero button on the monitor and wait while calibration occurs. When 'zeroed' is displayed on the monitor, replace the cap on the three-way tap and turn the tap on to the patient. Observe the CVP trace on the monitor. The waveform undulates as the right atrium contracts and relaxes, emptying and filling with blood. Document the measurement and report any changes or abnormalities.

CENTRAL VENOUS PRESSURE

THE CVP WAVEFORM: The CVP waveform reflects changes in right atrial pressure during the cardiac cycle A wave: right atrial contraction (P wave on the ECG)If the A wave is elevated the patient may have right ventricular failure or tricuspid stenosis. C wave: tricuspid valve closure (follows QRS complex on the ECG). V wave: pressure generated to the right atrium during ventricular contraction, despite the tricuspid valve being closed (latter part of the T wave on the ECG)

REMOVAL OF CENTRAL LINE: This is an aseptic procedure. The patient should be supine with head tilted down. Ensure no drugs are attached and running via the central line. Remove dressing. Cut the stitches. If there is resistant then call for assistance. Apply digital pressure with gauze until bleeding stops. Dress with gauze and clear dressing.

THE END