Oil Heat North Seattle Community College HVAC Program

Slides:



Advertisements
Similar presentations
Heating, Ventilation, and Air-Conditioning (HVAC) Systems
Advertisements

HVAC523 Heat Sources.
Furnaces also called Fired Heaters
Thermostats, Pressure Switches, and Other Electric Control Devices
HEAT PUMPS.
Cooling System Get the engine up to optimum operating Temperature as quickly as possible and maintains it at that temperature. Controls the heat produced.
The Home Inspection Book: A Guide for Professionals By Marcia Darvin Spada Copyright, Thomson/South-Western, 2003, Revised, 2006.
Student Book © 2004 Propane Education & Research CouncilPage Placing Appliances into Initial Operation Knowing the proper techniques and.
Basic Refrigeration Cycle
3.1.9 Student Book © 2004 Propane Education & Research CouncilPage Replacing Valves and Fittings in ASME Tanks Replacing ASME tank valves and fittings.
1926 Subpart J Establishes the requirements for welding and cutting in the construction industry Establishes requirements for equipment, fire protection,
Heating Control Devices
Watertube Boiler.
Objective of the session.
3.4.6 Student Book © 2004 Propane Education & Research CouncilPage Maintaining Bulk Plant Compressors Knowledge of the processes involved in maintaining.
Gas Welding (Oxy-acetylene)
Section 2 Safety, Tools and Equipment, Shop Practices Unit 4 General Safety Practices.
Unit 12 Oil Heat Components
 Latent heat  Sensible heat  Total heat  Specific heat.
Condensation Piping and Installation Drain Pans
1 HVAC222 - Oil Oil Characteristics Oil Heat Calculations Oil Characteristics Oil Heat Calculations.
HVACR416 - Design Humidification. Relative Humidity 1.Air in the home is artificially dried out when it is heated. 2.Because warm air expands, this expansion.
ELECRICAL CIRCUITS.
Fuel Oil Systems Fuel Oil Systems consist of: Storage Tanks Pumps
STEAM HEATING.
Hydronic Mechanical Controls
Mechanical for Oil Heat
Oil Heat Properties of Fuel Oil.
Muhajir Ab. Rahim School of Mechatronic Engineering
Gas Furnace Planned Maintenance
CHAPTER 6 Moving Heat: Heating and Air Conditioning Principles
Air-Source Heat Pumps I North Seattle Community College HVAC Program Instructor – Mark T. Weber, M.Ed. Airsource Heat Pump 1.
1 Combustion Oil Fired Equipment. 2 OIL Combustion of oil fired equipment has the same basics of gas. Remember, Oil is a liquid and this must be converted.
RESIDENTIAL AIR HANDLERS
NFPA 31 Standard for the installation of Oil- Burning Equipment
7.3.5 Student Book © 2005 Propane Education & Research CouncilPage Identifying the Function and Characteristics of Draft Fans & Controls High efficiency.
Flammable and Combustible Liquids. Introduction !The two primary hazards associated with flammable and combustible liquids are explosion and fire !Safe.
1 HVACR215 – Mechanical for Oil Oil Combustion. 2 Combustion The burning of a substance. Rapid Oxidation The burning of a substance. Rapid Oxidation.
Unit 4: General Safety Practices
Why Maintenance Tasks are Important Produced by Joe Marchese.
Oil Heat Oil Burner Parts.
Unit 8 Gas-Burning Equipment. OBJECTIVES State the difference between a natural gas and an LP gas system. Describe several control sequences for gas heat.
The Cooling System (Reasons for)
Chapter 39 Cooling System Fundamentals.
HEAT-GENERATING EQUIPMENT INTRODUCTION SELECTION EFFICIENCY FURNACES BOILERS CENTRAL HVAC SYSTEMS.
Flammable Liquids Directorate of Training and Education
Temperature Test Allows monitoring of temperature changes.
Unit 13 Oil-Burning Equipment
Section 6: Air-Conditioning (Heating And Humidification)
14 Refrigerant Recovery, Recycling, and Recharging.
Electrical Gas Plumbing Heating & Cooling
Flammable and Combustible Liquids
Cooling System Get the engine up to optimum operating Temperature as quickly as possible and maintains it at that temperature. Controls the heat produced.
Furnaces (also called Fired Heaters)
Cooling System Get the engine up to optimum operating Temperature as quickly as possible and maintains it at that temperature. Controls the heat produced.
Boiler Room LOG Sheets: Interpreting the Records
Presentation transcript:

Oil Heat North Seattle Community College HVAC Program Instructor – Mark T. Weber, M.Ed., CMHE Oil - 1

Objectives After studying this chapter, you should be able to: Describe various types of fuel oil List and describe the characteristics associated with fuel oil Describe different methods for storing fuel oil Explain how oil tanks are sized 2 2

Objectives (cont’d.)‏ Explain the importance of periodic oil tank inspection Describe how fuel oil and air are prepared and mixed in the oil burner unit for combustion List products of combustion of the fuel oil List the components of gun-type oil burners Describe basic service procedures for oil burner components 3 3

Objectives (cont’d.)‏ Sketch wiring diagrams of the oil burner primary control system and the fan circuit State tests used to determine oil burner efficiency Explain corrective actions that may be taken to improve burner efficiency, as indicated from the results of each test Describe preventive maintenance procedurs 4 4

Safety Checklist Do not reset any primary control too many times because unburned oil may accumulate after each reset Do not start a burner if heat exchanger is cracked or otherwise defective 5 5

Safety Checklist (cont'd.)‏ Do not start burner with the fuel pump bypass plug in place unless the oil delivery system is configured as a two- pipe system with both a supply and return line When conducting flue-gas efficiency tests, avoid burns by not touching the hot flue-gas pipe 6 6

Safety Checklist (cont'd.)‏ Keep your distance from the ignition arc Observe all electrical safety precautions Inspect oil burners and lines for leaks When installing oil tanks, make certain that all codes are followed Oil tanks need to be inspected periodically to minimize tank leakage 7 7

Introduction to Oil-Fired Forced-Warm-Air Furnaces Oil-fired forced-warm-air furnaces have two main systems: A heat-producing system, consisting of the oil burner, fuel supply components, combustion chamber, and heat exchanger A heat-distributing system, consisting of the blower, and other related components When thermostat calls for heat, ignition system is powered and oil burner motor starts

Physical Characteristics Lowboy Often used if there is not much headroom May have a cooling coil on top to provide air conditioning Upflow Vertical furnace in which the air is taken in at the bottom, forced across the heat exchanger and out the top

Physical Characteristics (cont'd.)‏ Downflow Looks similar to an upflow furnace except that air is drawn in from the top and forced out the bottom Horizontal Usually installed in a crawlspace under a house or in an attic Available with right-to-left or left-to-right airflow

Fuel Oil Delivered to the customer in liquid form and stored in tanks either aboveground or underground Oil used in residential and most commercial systems in the United States: basically diesel fuel that has been dyed red for tax purposes Derived from crude oil by a process of distillation called cracking

Fuel Oil (cont'd.)‏ There are six grades of fuel oil and a numbering system, 1 through 6, is used to identify each grade The lower-numbered oils are called light oils because they weigh less per gallon than the higher-numbered oils The lightest of these, No. 1, is most commonly known as kerosene Fuel oil No. 2 is known as pentane and is the most commonly used

Fuel Oil (cont'd.)‏ The ASTM sets standards for acceptable ranges for fuel oil characteristics: Flash point Has to do with the maximum safe storage and handling temperature for the fuel Lowest temperature at which vapors in air above the fuel ignite briefly when exposed to a flame Ignition point A few degrees higher than flash point Flame keeps burning because vapors keep rising from liquid

Fuel Oil (cont'd.)‏ Viscosity Carbon residue Thickness of the oil under normal temperatures Heavier oils are thicker at the same temperatures Expressed in Saybolt Seconds Universal (SSU)‏ Carbon residue Amount of carbon left in a sample of oil after boiling in an oxygen-free atmosphere Properly burned oil has no appreciable residue

Fuel Oil (cont'd.)‏ Water and sediment content Pour point Attempt to ensure that water, sediment, and other contaminant levels are as low as possible Sediment can form when rust forms on internal pipe; tank surfaces and sludge can form when water condensation reacts with the fuel oil Pour point Lowest temperature at which the fuel can be stored and handled No. 2 oil is one of the lower pour point fuels; can be used down to 20°F

Fuel Oil (cont'd.)‏ Ash content Distillation quality Amount of noncombustible materials contained in the fuel oil Can be abrasive and wear down burner components Distillation quality Describes ability of the oil to be vaporized Lighter oil turns into vapor easier than heavier oil

Oil Storage When possible, install tanks above ground for environmental reasons Follow all local codes when installing Oil tank sizing Tanks are available in sizes from about 100 gallons to over 1000 gallons Two main issues in selecting tank size are frequency of oil deliveries and quality of oil with respect to storage time Tank should hold about 1/3 of the annual oil consumption

Oil Storage (cont'd.)‏ Underground tanks Tanks installed underground must be protected against corrosion The most popular types are the STI-P3 tanks and fiberglass tanks See Figure 32-7 in text

Oil Storage (cont'd.)‏ Aboveground tanks Indoor oil storage Typically fabricated from 12 gauge steel and hold between 275 and 330 gallons of oil Polyethylene/steel tanks: tank within tank Galvanized steel outer tank protects the polyethylene inner tank and provides secondary containment in the event of a leaking inner tank Indoor oil storage Reduces temperature fluctuation as well as moisture and condensation inside the tank

Oil Storage (cont'd.)‏ Oil tank inspection and maintenance Aboveground tanks should be painted periodically and inspected on a regular basis STI-P3 tanks should be checked to ensure protective anodes are in good working order Tank piping should be inspected regularly for imperfections and leaks; always check for loose or missing vent and fill caps

Oil Storage (cont'd.)‏ Tanks should be checked for water at least once a year If water is present, the source of water should be identified and the situation corrected Tanks are tested for water content by placing a water-sensing paste on the oil tank stick Visually inspect aboveground tanks for damage to pipes, caps, oil lines, tank legs, and gauges and check for traces of oil under the tank

Fuel Oil Supply Systems Two common piping configurations: One-pipe system: only one pipe runs between the oil storage tank and the oil burner As oil is needed, it flows from tank to burner

Fuel Oil Supply Systems (cont’d.) Two-pipe system: one pipe is the supply and the other acts as the return Oil flows at maximum capacity to the burner where the system uses what it needs and the rest flows back to the tank via the return line One-pipe system is used when tank is located above the oil burner; two-pipe when tank is below

Fuel Oil Supply Systems (cont'd.)‏ Key points about fuel oil lines and piping: Oil lines should be sized at a minimum of 3/8” OD copper lines Oil lines can be constructed of wrought iron, steel, or brass pipe connected with malleable fittings; never use cast-iron fittings Never use PVC pipe for oil lines Use only flare connections to join oil lines

Fuel Oil Supply Systems (cont'd.)‏ When needed, use only a non-hardening, oil-resistant pipe joint compound When installing oil lines, make the runs as short as possible, use as few fittings as possible, and avoid kinking the lines Be sure that all oil lines are secured and protected from damage Ensure lines run outside are well insulated

Fuel Oil Supply Systems (cont'd.)‏ Underground oil lines should be installed with secondary containment There should be a shutoff valve on the suction line at the oil burner Fill and vent pipes should pitch toward tank opening to prevent formation of oil traps A vent alarm should be installed in all tanks at the vent opening

Fuel Oil Supply Systems (cont'd.)‏ The oil dearator allows a one-pipe system to function as a two-pipe system Auxiliary fuel systems get the fuel supply to the burner if it is too far above the tank Fuel line filters remove fine solid impurities Oil safety valve (OSV) stops oil flow if there is a leak in the suction line

Preparation of Fuel Oil for Combustion Liquid oil must be atomized (broken up into droplets)‏ Oil droplets mix with air, which contains oxygen High-pressure gun-type oil burners feed oil through a nozzle under pressure and force air through a tube surrounding it

By-Products of Combustion The correct ratio of fuel to air is required for proper combustion 1 lb of fuel oil must be mixed with about 3 lb of oxygen for complete combustion to occur Air is approximately 79% nitrogen and 21% oxygen; 192 ft³ are needed to burn a single pound of fuel oil Most oil burners provide 50% excess air Needs 21.6 lb or 288 ft³ of air for 1lb fuel oil By-products are heat, flue gases, CO2, and water vapor

Gun-Type Oil Burner Oil and air are forced into the burner for mixing and ignition Flame retention burner design improves on conventional design Main parts: Burner motor provides power for fan/pump Burner blower forces air into the chamber Fuel oil pumps deliver oil to the chamber Nozzle atomizes air prior to ignition

Gun-Type Oil Burner (cont'd.)‏ Air tube delivers air to the chamber Electrodes vaporize atomized oil droplets and provide spark for ignition Ignition transformer provides high voltage to electrodes Solid state igniters are found in newer oil burners, replacing ignition transformers Primary control unit provides means for operating the burner and a safety function to shut down the burner if icombustion does not occur

Gun-Type Oil Burner (cont'd.)‏ Figure 32-30 Diagram that compares the flames created by conventional and flame-retention oil burners 32

Oil Furnace Wiring Diagrams Includes wiring for the fan, the oil burner primary, and the 24-volt control circuits The limit switch is a safety that passes power to the primary control On a call for heat, power is passed to the ignition transformer, burner motor, and fuel valve The safety device will shut the burner down in case of a problem

Safety Controls Stack switch safety control Cad cell safety control Positioned in the flue pipe Bimetal heated by combustion flue gases Hot contacts allow the burner motor to continue operation Cold contacts allow current to flow through safety switch heater Cad cell safety control When the burner fires, the cad cell senses light and its resistance drops, causing the triac to open

Combustion Chamber Atomized oil is burned in suspension in the combustion chamber Oil that is not completely ignited will hit the chamber walls and condense Oil vapor hitting chamber walls and condensing will lower combustion efficiency The burner must be matched to the chamber The chamber is a box to contain the fire

Heat Exchanger Transfers heat from combustion to the air that is circulated to heat the structure Separates flue gases from the air circulated to heat the structure Should be inspected for cracks during normal service Most state codes prohibit repairing cracks by welding Correct airflow across the heat exchanger is important

Condensing Oil Furnace More efficient than conventional furnaces Combustion system includes: Burner and related components, combustion chamber, as many as three heat exchangers, and vent fan and pipe In third heat exchanger, temperatures are reduced below dew point Heated air circulation system includes: Blower fan, housing, motor, plenum, and duct system

Service Procedures Pumps: connect vacuum and pressure gauges to pump Pressure should be 0 psig if tank is above burner If tank is below burner, pressure should not be lower than 17 in. Hg 1 in. Hg for each foot of vertical lift 1 in. Hg for every 10 feet of horizontal run Nozzle pressure should be steady at 100 psig or 140 psig depending on the burner assembly

Service Procedures (cont'd.)‏ Burner motors: press reset button to see if motor will start Check for voltage between orange and white wires of the primary control If there is no voltage, the primary control needs to be checked Check for voltage between black and white wires on the burner motor If there is voltage and the motor does not turn, the motor is defective

Service Procedures (cont'd.)‏ Nozzles: do not try to repair a nozzle Nozzles are often replaced annually Always make certain to use the correct nozzle size Use proper tools to remove nozzles Overheating nozzles can result in oil breakdown After-drip can result in the nozzle getting clogged

Service Procedures (cont'd.)‏ Ignition system Transformer Turn power off and swing the transformer back Shut off fuel supply to the burner Restore power to the burner Check for output voltage of 10,000 volts Electrodes Ensure the spark gap settings for proper position Check insulation for cracks Keep electrodes clean

Combustion Efficiency Areas to test for proper combustion: Draft: determines rate at which flue gases pass through the furnace Too much increases stack temperature, too little can result in pressure and smoke Smoke: indicates incomplete combustion and fuel waste Net stack temperature CO2: good indicator of combustion efficiency Low reading indicates fuel oil has not burned completely

Summary Oil-fired furnaces are made up of heat- producing and heat-distributing systems No. 2 fuel oil produces about 140,000 Btu/gal Fuel oil must be atomized before combustion 43 43

Summary (cont’d.)‏ Typical oil burner contains a motor, blower, fuel pump, nozzle, electrodes and primary control Nozzles rated by flow rate, angle, and spray pattern Ignition transformers and electronic igniters provide the high voltage needed for spark ignition 44 44

Summary (cont’d.)‏ The primary control controls burner operation and safety functions of the system Primary controls can use cad cells or stack relays The resistance of a cad cell decreases as the amount of light sensed increases 45 45

Summary (cont’d.)‏ The stack relay responds to the stack temperature Condensing furnaces are more efficient than conventional furnaces 46 46

For more information please contact Mark T. Weber, M.Ed, CMHE At North Seattle Community College WWW.NorthSeattle.edu Mark.weber@seattlecolleges.edu