Increasing the Throughput of Challenging Assays by Automation Malcolm Crook Process Analysis & Automation Ltd Farnborough.

Slides:



Advertisements
Similar presentations
Getting to Know the AAnalyst 200
Advertisements

NEXGEN Four All automated microplate processors today can perform the steps required to process an ELISA microplate test However, most systems today operate.
AS Bioscope TM Multiple sampling of your bacteria using an innovative portable respirometer. Bioscope is a portable real-time respirometer that provides.
Mass Spectrometer Autosampler Jake Ahrens Stephen Pearson Kyle Sala Seth Yellin Project Mentor: Professor Jane Hill.
Nanion Introducing: SyncroPatch 384PE - the PatchEngine. Superior Ion Channel Drug Screening.
Fast, Accurate and Reliable Robotic Storage System
Solutions for Scheduling Assays. Why do we use laboratory automation? Improve quality control (QC) Free resources Reduce sa fety risks Automatic data.
An Introduction to Flame Atomic Absorption Spectrometry (FAAS) Steve Badger and Charity Wessel.
FLAME SPECTROSCOPY The concentration of an element in a solution is determined by measuring the absorption, emission or fluorescence of electromagnetic.
TEMPLATE DESIGN © High-Throughput Non-Contact Acoustic Liquid Dispensing Systems New Challenges in Automation and Implementation.
Automated Immunoassays Multi-test immunoassays are the most widely used rapid test format – worldwide – ELISA / EIA (Assurance EIA, TECRA) – ELFA (Vidas)
Research Techniques Made Simple: The Use of Luminex Assays To Measure Cytokines Saami Khalifian, B.A., Giorgio Raimondi, Ph.D., & Gerald Brandacher, M.D.
Contiki A Lightweight and Flexible Operating System for Tiny Networked Sensors Presented by: Jeremy Schiff.
Atomic Absorption Spectroscopy (AAS)
Monroe L. Weber-Shirk S chool of Civil and Environmental Engineering Atomic-Absorption (AA) Spectroscopy 
Laboratory Automation Integrating equipment into a multi-vendor world.
70-293: MCSE Guide to Planning a Microsoft Windows Server 2003 Network, Enhanced Chapter 7: Planning a DNS Strategy.
User Interfaces for University Laboratory Work cells Malcolm Crook Process Analysis & Automation Lecturer, MChem Course, University of Surrey Lecturer,
Tiered architectures 1 to N tiers. 2 An architectural history of computing 1 tier architecture – monolithic Information Systems – Presentation / frontend,
High Throughput And High Content Screening. What Is HTS ? Biochemical target  Test many compounds  Compounds with desired effect on target = Hit  OR.
BC ILN Atomic Absorption Spectroscopy (AAS) 1 Thompson Rivers University.
Protein arrays LEAPS technology An array of 110 different antibodies incubated with various levels of the fluorescently labelled cognate antigens in a.
Laboratory automation experimental setups. who are paa ?
Introducing the LEO 1400 Series
Simoa Accelerator Laboratory
‘At the Coal Face’ Experiences of Computer-based Exams John Winkley, BTL Paul Humphries, Edexcel Dorit Reppert, CCEA July 8 th 2003.
1 BTEC HNC Systems Support Castle College 2007/8 Systems Analysis Lecture 9 Introduction to Design.
© Process Analysis & Automation 2005 Short Course “I want to Automate that Process” Malcolm Crook.
Lab Bot 800 Dual Arm Fully Automated Liquid Handling Workstation.
Institute of Isotopes Hungarian Academy of Sciences Nuclear electronics for NCC measurements and training J. Bagi, J. Huszti, K. Szirmai Department of.
Intelligent Automation. Who are PAA ? Who are Process Analysis & Automation ? Incorporated in 1992 Software supplier, OVERLORD Offer systems integration.
© Process Analysis & Automation Ltd Process Analysis & Automation Maximizing Investment Automated solutions of technology platforms Malcolm Crook.
900-LC P. van Poppel – Field Support Specialist October 2009.
Frankfurt (Germany), 6-9 June 2011 Smart Grid Protection in China Wu Guopei Guangzhou Power Supply Bureau Guangdong Power Grid, China.
Architectural Design lecture 10. Topics covered Architectural design decisions System organisation Control styles Reference architectures.
Parallel and Distributed Simulation Introduction and Motivation.
Reference: Ian Sommerville, Chap 15  Systems which monitor and control their environment.  Sometimes associated with hardware devices ◦ Sensors: Collect.
Beyond the technology beyond the technology Heartlands Instrument Integration Vitamin D Workflow.
Minibioreactors -> Volumes below 100 ml Characterized by: -> area of application -> mass transfer -> mixing characteristics.
IntelliSense.io Beyond the hype - Real World Applications / Solutions of Internet of Things.
NIH Resource for Biomolecular Modeling and Bioinformatics Beckman Institute, UIUC NAMD Development Goals L.V. (Sanjay) Kale Professor.
NIH Resource for Biomolecular Modeling and Bioinformatics Beckman Institute, UIUC NAMD Development Goals L.V. (Sanjay) Kale Professor.
IGEM: Measurement Techniques for Pathway Output Noah Helman Lim Lab May 2007.
Logic Analyzer ECE-4220 Real-Time Embedded Systems Final Project Dallas Fletchall.
© Process Analysis & Automation Ltd Process Analysis & Automation Sales Presentation.
(c) Process Analysis & Automation Ltd © Process Analysis & Automation Ltd Introduction OVERLORD™ Labcyte Echo 550 Nanolitre Dispenser Extending.
MGA Duplica Replication Tool. 1. High Availability and Avoidance of Data Loss  Replicate to alternate databases 2. Split activities across databases.
ANALYSIS OF GENE EXPRESSION DATA. Gene expression data is a high-throughput data type (like DNA and protein sequences) that requires bioinformatic pattern.
For use with WJEC Performing Arts GCSE Unit 1 and Unit 3 Task 1 Music Technology Technical issues.
LECIS - based Laboratory Automation in the Pharmaceutical Industry “plug-and-play” of equipment with a common interface that is independent of the vendor.
Detect and identify Bioanalytik 1 LB 930 BUTLER Plate Handling Robot.
Fully Automated High Throughput Ion Channel Screening July 2003 Adrian Kinkaid, PhD Head of Biology 1 BioFocus plc.
신기술 접목에 의한 신약개발의 발전전망과 전략 LGCI 생명과학 기술원. Confidential LGCI Life Science R&D 새 시대 – Post Genomic Era Genome count ‘The genomes of various species including.
LS96 (working name) Confidential information. Content Idea Configuration Technical Data USPs / Benefits Application Project Roadmap.
전통적인 신약 개발 과정.
Beadlyte multiplex assays/Luminex
Ions channels definition of ion channels: A protein that acts as a pore in a cell membrane and permits the selective passage of ions (such as potassium.
Making the Case for Business Intelligence
Latency and Communication Challenges in Automated Manufacturing
Components of Optical Instruments
SCADA for Remote Industrial Plant
Cell Viability assay
Chapter 12: Automated data collection methods
MENG 447 Manufacturing Systems Automation Chapter 1*
Page Replacement.
Fault Tolerance Distributed Web-based Systems
Diagnostics Analytical 920 LC Semi-Prep 940 LC
Bridging the Gap Between Technology and Business
Universal Serial Bus (USB)
FLAME SPECTROSCOPY The concentration of an element in a solution is determined by measuring the absorption, emission or fluorescence of electromagnetic.
Presentation transcript:

Increasing the Throughput of Challenging Assays by Automation Malcolm Crook Process Analysis & Automation Ltd Farnborough

What is a challenging assay ? Challenging instrument to automate –Physically –Software control, no automation interface Multiple PCs required

Why are we doing this Assay Development Low/High Throughput Screening

 Bioinformatics  Molecular biology  Expression studies  Stable cell generation  Bioinformatics  Molecular biology  Expression studies  Stable cell generation  Potency  Selectivity  Potency  Selectivity  Multiple platforms  Multiple readouts  Multiple platforms  Multiple readouts  'Big pharma' systems  Library choice  'Big pharma' systems  Library choice  Functional effects  Target-related  HERG  Cytotoxicity  Apoptosis  Cell proliferation  CYP450  Functional effects  Target-related  HERG  Cytotoxicity  Apoptosis  Cell proliferation  CYP450 Assay Target HTS Hit Evaluation Lead Optimisation Drug Discovery Process

Requirements for an Assay High-throughput Low false-positive rate Low false-negative rate Direct measure of function Good correlation with electrophysiology Reliability Reproducibility Amenable to miniaturization Low cost

Ion Channels by Atomic Absorption At BioFocus, Cambridge

assembly of proteins circular arrangement of proteins closely packed around water-filled pore large-pore channels permit –passage of ions –more or less indiscriminate What is an ion channel ?

archetypal channel pore –one or two atoms wide –conducts a specific species of ion –sodium or potassium –conveyed through membrane single file –fast –access to the pore is governed by a "gate“ –opened or closed by chemical/electrical signals Temperature mechanical force

Redistribution voltage-dependent dyes FRET-based technology Radioligand binding Automated two-electrode voltage clamp Automated whole-cell patch clamp Planar patch clamp Radiometric ion flux Non-radiometric ion flux Measuring Ion Channels Non-radiometric ion flux Radioactive Cost Low throughput

Chosen method Atomic absorption spectrometry 85 Rb+ Hollow cathode Rubidium lamp Air/acetylene flame

Advantages of AAS Health and Safety Ease of handling Cost of components Cost of disposal Environmental Impact Sensitivity No time limits to read samples Decay or Licence constraints

Manual Assay Processing electronics Spray chamber and nebulizer Hollow cathode lamp source Flame Monochromator Photomultiplier detector Data processing and instrument control

Detection

Manual Assay Atomic Absorption Burner Autosampler

Automated Assay Ion Channel Screening Cells processed using appropriate automation Supernatants analysed for Ion Content –Single burner system (low throughput) –Multi burner system

Automated Platform: Reader platform initial design SOLAAR S AAS #1 AutoSampler 4 Position #1 SOLAAR S AAS #2 AutoSampler 4 Position #2 SOLAAR S AAS #3 AutoSampler 4 Position #3 SOLAAR S AAS #4 AutoSampler 4 Position #4 Linear Track Robotic arm 80 microplate On-line Storage Operating system e.g. OVERLORD™ Data Processing Activity Base All equipment “off the shelf”

Schematic AA #3 AA #4 AA #2 AA #1 Robot bc stacker

What is the challenge for this assay ? 1.Scheduler has to be flexible to time delays 2.SOLAAR software-no automation interface 3.Four AAs required to achieve throughput 4.Autosampler was not robot friendly 5.Safety 6.Data handling/data quality

1. Scheduler needs to be flexible AA run times not the same Throughput critical Error trapping and recovery a necessity

Scheduler control options Time resolved –Static –Pre-emptive –All decisions are taken before the run starts. i.e. before the “GO” button is pressed Event driven –Real time –Dynamic –All decisions are taken during the time frame of the run, i.e. once the “GO” button is pressed Process Analysis & Automation have both !

Time resolved Advantages: –one or more accurate timings are guaranteed –easy to set up Disadvantages –inflexible –decisions can not be taken during the run –error recovery more difficult

Event Driven Advantages: –flexible –decisions can be taken during the run –error recovery easy Disadvantages –accurate timings are more difficult to set up –two accurate timings in a run are impossible

Scheduling - the Choice real-time OVERLORD Workstation pre-emptive OVERLORD Scheduler either

Real Time Instrument Control Options Sequential Round robin

Control system Main controller & Data processing OVERLORD AA#1 instrument control NetLORD node 1 AA#2 instrument control NetLORD node 2 AA#3 instrument control NetLORD node 3 AA#4 instrument control NetLORD node 4 Multiple port switchSite computer services

Instrument control – Round Robin Load, unload busy, error ? AA #2 node Ready ? Error AA #3 node Ready ? AA #4 node Ready ? Start Run Run AAS Load plate AA #1 node Ready ? Data HandlingCycle Run complete ? Unload plate Busy

2. SOLAAR software Requires automation interface There isn’t one !!!! Use the OVERLORD keystroke API Emulates a user

3. Four AAs required for throughput Use NetLORD Remote OVERLORD nodes Makes control structure easier –Node in 4 states Ready for load Ready for unload Busy Error state NetLORD nodes addressed by IP address Common folders for data transfer Redundancy

4. Autosampler was not robot friendly

5. Safety Hazards –AAS instrument Locked room Air conditioning –Acetylene gas Only run during the day Gas detectors Time out on AAS flames –Robot Hamilton SWAP stops when touched Hamilton SWAP can be recovered

6. Data handling/data quality Barcodes Data file renaming for integrity Data transfer to the server Real time data analysis for quality check

Luminex Instrument

Luminex 100 Bead based with 100 assays per well Small sample volume 1000 samples a day reproducible

Higher throughput Traditional ELISA 1 measurement/well xMAP technology 100 measurements/well

Analysis method Beads sucked up past fluorescence source Fluorescence detected

Luminex xMAP Technology Comparison Q-PCR ELISA Microarray Multiplex Throughput

What is the challenge for this assay ? Luminex software - no automation interface Luminex instrument – not robot friendly Caliper Twister I Lids

Luminex instrument – not robot friendly Plate tray only suitable for fingers –Modify the tray with a hacksaw Software –Version 1.7 no automation interface –Keyboard control possible

Caliper Twister I Limited control system –OVERLORD has own Twister I control Lids –Can be a problem –Relidding especially

Luminex Shaker Delidding Twister I

Conclusions Instruments can be automated –Keyboard control –Plate access Unusual assays –Real time scheduler –Round robin method Twister I robots good tools –Need more than basic software OVERLORD can control > 220 instruments And remember …..

Real high throughput screening !