Pollution Controls and Available Monitoring Techniques A quick summary of various control measures and important monitoring characteristics Peter Westlin,

Slides:



Advertisements
Similar presentations
MicroMistTM Wet Scrubber Advanced Scrubbing Technology
Advertisements

Oxidation (Incineration)
Sampling and Measurement for Volatile Organic Compounds
MEASURES TO REDUCE NO x EMISSIONS M. Sc. Engineering Policy and Technology ManagementEnergy Management and Policy Por: Miguel Leocádio João Meyer MEASURES.
Sara Jones 24NOV08. Background  In most conventional combustion processes, air is used as the source of oxygen  Nitrogen is not necessary for combustion.
NOx Sources and Control Methods CE/AE 524B Air Pollution J. (Hans) van Leeuwen.
Control Device Technology A quick summary of various control measures and important monitoring characteristics Peter Westlin, EPA, OAQPS.
TMTS NOx CONTROL for STATIONARY SOURCES Copyright TMTS Associates, Inc. and J.J. Santoleri, 2001, all rights reserved.
NOx Control.
ERT 319 Industrial Waste Treatment Semester /2013 Huzairy Hassan School of Bioprocess Engineering UniMAP.
Control of Sulfur Oxides Dr. Wesam Al Madhoun
Desulfurization (DeSO x ). Limestone is the alkali most often used to react with the dissolved sulfur dioxide. Limestone slurry is sprayed.
Air Pollution Chapter 5.
Common air pollution Control equipment : Method of removal Particulate Matter 1. Gravitational Settling Chamber 2. Cyclone 3. Inertial Dust Separator.
1 Environment Engineering I Dr. Amal Hudhud Dr. Abdel Fattah Hasan An-Najah National University Civil Engineering Department Air Pollution Chapter Eleven-
Stationary Source Controls & Source Sampling Marti Blad Ph.D., P.E.
Environmental Engineering 343
Previous MACT Sub Categories EPA has recognized differences in other industry rules by using sub-categorization: – Differences in processes – Differences.
Air Pollution- Measures to Improve Air Quality Cheung Wing Yu 7S (24) Poon Shu Ying 7S (29)
Overview: Hazardous Waste Combustion. What is Hazardous Waste? Definition of Hazardous Waste –Hazardous wastes are distinguished from other wastes by:
Air pollution control methods. Introduction Air pollution control can be generally described as a “separation” technology. The pollutants, whether they.
LOCAL EXHAUST VENTILATION …study of the principles associated with proper application of local exhaust ventilation (LEV) for control of airborne contaminants.
Control of Nitrogen Oxides Dr. Wesam Al Madhoun. Specific sources of NO x Combustion sources Automobiles Boilers Incinerators High-temperature industrial.
Control Device Technology
Control and regulation of boiler operation Heat Engines & Boilers.
Municipal Solid Waste Incineration
Wednesday, 12/12/2007, FYROM Prevention of Contamination from Mining & Metallurgical Industries in FYROM Strategic Plan for Prevention of Contamination.
Monday, 10/12/2007, SERBIA Prevention of Contamination from Mining & Metallurgical Industries in Serbia Strategic Plan for Prevention of Contamination.
Vehicle pollution control
AIR POLLUTION PREVENTION AND CONTROL Dr. Wesam Al Madhoun.
Air Cleaning Devices. 2 Is An Air Cleaner Needed ?  Toxicity of materials discharged  Amount of material to be discharged  Value of material to be.
The Greenhouse Effect CE 326 Principles of Environmental Engineering Prof. Tim Ellis January 25, 2010.
Multi-Stage Flash Desalination (MSF)
Chemistry. Surface Chemistry - 1 Session Session Objectives  Adsorption versus absorption  Types of adsorption: physisorption and chemisorption  Desorption.
Overview: Secondary Aluminum
Co-precipitated manganese oxides- based sorbents for mercury and arsenic capture. Malgorzata Wiatros-Motyka EPSRC PhD project student Grant: EPSRC China.
1 Combustion Oil Fired Equipment. 2 OIL Combustion of oil fired equipment has the same basics of gas. Remember, Oil is a liquid and this must be converted.
Lecture Objectives: Finish boilers and furnaces Start with thermal storage systems.
BYD.RAVIKUMAR.  AIR POLLUTION UNIT – I Air pollution: Air pollution is defined as “presence in the outdoor atmosphere of one are more contaminents such.
Analysis of Existing and Potential Regulatory Requirements and Emission Control Options for the Silver Lake Power Plant APPA Engineering & Operations Technical.
Air Emissions Treatment. Because air pollutants vary in size many orders of magnitude, many different types of treatment devices are required for emissions.
Lecture Objectives: Continue with power generation Learn basics about boilers and furnaces.
 Products of incineration  sifting  fine material include ash, metal fragments, glass, unburnt organic substances etc..  residue  all solid material.
Objectives -Discuss Exam -Finish with -Boilers -Discuss low temperature energy systems.
Objectives -Discuss Final Project -
Stationary Source Controls & Source Sampling Marti Blad, PhD, PE.
Scrubbers Colloquium N. Maximova and the class. Puu
Title: Lesson 13: Acid Deposition
OVERVIEW OF PMSB INCINERATOR PLANT 1.Primary Chamber 3.Secondary Chamber 4.Heat Exchanger 5.Cooling Tower 7.Rotary Contactor 8.Fabric Filter 9.ID Fan 10.Stack.
2.14.  In 1970 the Environmental Protection Agency (EPA) was established  Required to set and enforce air quality standards  Air quality standard –
Lancom 4 In Power and Boilers Derek Stuart. Lancom 4 In Power and Boilers Derek Stuart Combustion Theory In order to maximize the heat capture (efficiency)
Ambient air sampling and monitoring Topic 5 Ms. Sherina Kamal.
Aerosol & Particulate Research Lab
1Korea University of Technology and Education 2 Generation Common Rail VGT Variable Swirl 32Bit Computer Elec. Controlled EGR Flap C P F Electronically.
AIR POLLUTION PREVENTION AND CONTROL
Pollution Controls and Available Monitoring Techniques
UNECE Convention on Long-range Transboundary Air Pollution
Pollution control methods of thermal power plants
Air pollution control:
Control of Sulfur Oxides Dr. Wesam Al Madhoun
Crude oil Treatment process
Control of Air pollution
Air Pollution Control Devices
CE 326 Principles of Environmental Engineering
AIR POLLUTION CONTROL TECHNIQUES
Chapter 12. Air Pollution Control
Air Pollution Control: Stationary source
Air Pollution and Stratospheric Ozone Depletion
UNIT III PARTICULATE SCRUBBES. PARTICULATE SCRUBBERS or WET COLLECTORS Scrubbers are air pollution control devices that use liquid(often water) to remove.
Presentation transcript:

Pollution Controls and Available Monitoring Techniques A quick summary of various control measures and important monitoring characteristics Peter Westlin, EPA, OAQPS

Topic areas  THC and OHAP Adsorbers Thermal Oxidizers Catalytic Oxidizers Condensers Capture Systems  PM ESP Fabric Filter Venturi Scrubber  Acid Gases Wet scrubbers Dry Injection Mercury  NOx Selective Catalytic Reduction NSCR Water Injection Low Nox Burners  Other Sulfur in Coal & Oil Coatings and Solvents Design Specs Process Operations 2

THC/OHAP Control Techniques – Carbon Adsorber  Some gas molecules will stick to the surface of some solids  Activated carbon often used for THC/OHAP control Has a strong attraction for organic and non-polar compounds Has a large capacity for adsorption (many pores, lots of surface area) Is cheap  Silica gel, activated alumina, and zeolites are also used 3

THC/OHAP Control Techniques – Carbon Adsorber  Three types – fixed bed (most common), moving bed, and fluidized bed  Typically appear in pairs – one adsorbing while other desorbs  Used for material recovery as well as emissions control  Regenerated via steam, hot gas, or vacuum 4

5

Carbon Adsorber – Fixed Bed Examples 6

THC/OHAP Control Techniques – Carbon Adsorber Compliance monitoring  Outlet THC or compound specific concentration (CEMS)  Parametric and other monitoring Regeneration cycle timing (e.g., minutes), steam flow, or vacuum profile (e.g., delta P for x minutes)  Initial performance tests for confirmation  Periodic testing Carbon bed activity (e.g., quarterly) 7

THC/OHAP Control Techniques – Thermal Oxidizers General description  Waste gas combusted with or without auxiliary fuel to carbon dioxide and water  Operating temperatures between 800 and 2000°F  Good combustion requires (remember chemistry class?) Adequate temperature Sufficient oxygen Turbulent mixing Sufficient residence time 8

THC/OHAP Control Techniques – Thermal Oxidizers  Two basic types – thermal oxidizer (TO) and regenerative thermal oxidizer (RTO)  After construction, process control limited to temperature and oxygen (air to fuel ratio) concentration  Waste gas has to be heated to autoignition temperature Typically requires auxiliary fuel Can be enhanced with heat recovery exchangers 9

THC/OHAP Control Techniques TOs and RTOs 10

THC/OHAP control - RTO 11

THC/OHAP Control Techniques – Thermal Oxidizers Compliance monitoring  Outlet THC or compound-specific concentration (CEMS)  Parametric and other monitoring Outlet CO concentration (CEMS)  Correlated with test results Combustion chamber temperature  Correlated with test results Periodic testing to confirm 12

THC/OHAP Control Techniques – Catalytic Oxidizer General description  Construction similar to TO or RTO but includes catalyst layer or bricks  Catalyst causes combustion reactions to occur faster and at lower temperatures (~ 650 to 1000°F)  Saves auxiliary fuel 13

Catalytic Oxidizer – Example Bricks Regenerative catalyst oxidizer 14

THC/OHAP Control Techniques – Catalytic Oxidizer Performance monitoring  Outlet THC or compound-specific concentration (CEMS)  Parametric and other monitoring Catalyst bed inlet temperature or temperature rise across catalyst bed (if inlet concentration is constant)  Correlated with test results  Periodic catalyst activity tests (e.g., semi-annually) Periodic testing  NOT outlet CO concentration (CO preferentially combusted in THC catalysts) 15

THC/OHAP Control Techniques - Condenser  General description Gas or vapor liquefied and removed from gas stream via  Lowering temperature or  Increasing pressure Used to collect and reuse organic materials (e.g., solvents) Used as pretreatment to reduce volumes 16

THC/OHAP Control Techniques - Condenser  Two structural types – contact and surface condensers No secondary pollutants from surface type More coolant needed for contact type  Chilled water, brines, and CFCs used as coolants  Efficiencies range from 50 to 95 percent 17

THC/OHAP Control Techniques – Surface Condenser 18

THC/OHAP Control Techniques - Condenser Compliance monitoring  Outlet THC or compound-specific concentration (CEMS)  Predict emissions via equilibrium calculations (e.g., organic chemical MACT)  Parametric and other monitoring Outlet gas temperature (e.g., at or below dew point)  Correlated with testing or with equilibrium calculations Coolant inlet/outlet temperature  Correlated with testing Periodic testing 19

THC/OHAP Control Techniques – Capture Systems  General description Two types of systems  Enclosures and local exhausts (hoods) Two types of enclosures  Permanent total (M204 definition) – 100% capture efficiency  Nontotal or partial – must measure capture efficiency via Method 204  Total THC control efficiency is product of capture and control device efficiencies 20

THC/OHAP Control Techniques – Capture System 21

THC/OHAP Control Techniques – Capture Systems Compliance monitoring (parametric)  Permanent total enclosures Differential pressure (e.g., < in. H 2 O) Daily inspections  Local capture (design and work practice) Conduct visible and portable analyzer leak checks Set spacing above process Monitor exhaust flow rate/differential pressure in duct near hood 22

Take-aways about THC/OHAP control device monitoring:  What can we say about CEMS for monitoring gaseous organic emissions?  If not CEMS, which operating parameters are appropriate for monitoring compliance for Adsorbers? Thermal oxidizers? Catalytic oxidizers? Capture systems? 23

PM Control Techniques – Electrostatic Precipitator (ESP) General Description  Charged particles are attracted to grounded plates and removed from exhaust gas  Two types Dry type use mechanical action to clean plates Wet type use water to prequench and to rinse plates (good for removing condensable PM)  High voltages  Often with multiple sections (fields)  Efficiencies up to 99+ percent with multiple sections 24

PM Control Techniques - ESP 25

PM Control Techniques – ESP Compliance monitoring  Outlet PM concentration (PM CEMS)  Parametric and other monitoring Opacity and secondary power (current and voltage)  Correlated with testing Periodic testing EPRI model on TTN/EMC website  Comprehensive site-specific correlation  Makes use of EPA ESP design model 26

PM Control Techniques – Fabric Filter (bag house) General description  Particles trapped on filter media and filter cake  Either positive or negative pressure (push me, pull you)  High efficiency for all particle sizes (> 99 percent)  Frequent bag cleaning Shaker (off-line) Reverse air (low pressure, long time, off line) Pulse jet (60 to 120 psi air, on line) Sonic horn (150 to to 140 dB, on line) 27

PM Control Techniques – Fabric Filter - Schematic 28

PM Control Techniques – Fabric Filter Compliance monitoring  Outlet PM concentration (PM CEMS) Works for negative pressure FFs Not so good for positive pressure FFs  Parametric and other monitoring Bag leak detectors (very good choice) Outlet opacity (not so good choice) Pressure differential (bad choice) Periodic inspections Periodic testing 29

PM Control Techniques – Wet Venturi Scrubber  Capture of particles in liquids through inertial impaction (less effective at removing gases)  High energy (velocity through Venturi throat) with pressure drops >20 in. H 2 O  Can be fixed or adjustable throats  Require exhaust stream mist separators  Less efficient than FF or ESP (90-98 percent) 30

PM Control Techniques – Wet Venturi Scrubber 31

PM Control Techniques – Wet Venturi Scrubber Compliance monitoring  Outlet PM concentration (extractive PM CEMS can work)  Not COMS (water vapor interference)  Parametric and other monitoring Pressure differential AND liquid flow rate  Correlated with performance testing  Periodic inspections Periodic testing 32

Take-aways about PM control device monitoring:  What can we say about CEMS for monitoring PM emissions?  What about ESPs and Venturi scrubbers distinguishes them from fabric filters?  If not CEMS, which operating parameters are appropriate for monitoring compliance for ESPs? Venturi scrubbers? Fabric filters? 33

Acid gas control – wet flue gas scrubbers General description  Acid gases mix with wet alkaline slurries sprayed in packed or plate/tray towers  Lime, limestone, and sodium bicarbonate often used as sorbents  Typical efficiencies on the order of >98 percent 34

Acid gas scrubbers 35

Compliance monitoring  Acid gas (e.g., SO 2, HCl) concentration (CEMS)  Parametric and other monitoring Slurry pH AND liquid flow rate  Correlated with testing  Periodic inspections (check packing)  Not pressure drop or flow rate Periodic testing Acid gas scrubbers 36

Acid Gas and Hg Control Techniques – Dry Injection General description  Sorbent injected into process  Sorbent reacts with gas to form salts that are removed in a PM control device (fabric filter)  Hydrated lime and sodium bicarbonate often used as sorbents for acids  Activated carbon used for Hg 37

Acid Gas and Mercury Control Techniques – Dry Injection 38

Dry injection control systems  Acid gas (e.g., SO 2, HCl) concentration (CEMS)  Hg CEMS or sorbent trap  Parametric and other monitoring Adsorbent injection rate  Correlated with testing PM control device monitoring Periodic testing 39

Take-aways about acid gas and Hg control device monitoring:  What can we say about CEMS for monitoring acid gas or Hg emissions?  What about acid gas scrubbers distinguishes them from and Venturi scrubbers?  If not CEMS, which operating parameters are appropriate for monitoring compliance for Acid gas scrubbers? Dry injection? 40

NO x Control Techniques – Selective Catalytic Reduction General description  Ammonia or urea is injected into exhaust streams with plenty of oxygen to reduce NO x to N 2 and water  Catalysts made from base and precious metals and zeolites  Operating temperatures range from 600 to 1100°F  Efficiency ranges from 70 to 90 percent 41

NO x Control Techniques – SCR Schematic 42

NO x Control Techniques – Selective Catalytic Reduction Compliance monitoring  Outlet nitrogen oxide concentration (CEMS)  Parametric monitoring Ammonia / urea injection rate  Correlated to testing Catalyst activity Initial and periodic testing 43

NO x Control Techniques – Non Selective Catalytic Reduction General description  Low oxygen exhaust gas transforms via catalytic reaction to form water, CO 2, and N 2 (commonly applied to engines)  Catalysts made from noble metals  Operating temperatures range from 700 to 1500°F  Efficiency ranges from 80 to 90 percent 44

NO x Control - NSCR Oxidation catalyst 45

NO x Control Techniques – Non Selective Catalytic Reduction Compliance monitoring  Outlet nitrogen oxide concentration (CEMS)  Parametric monitoring Catalyst bed inlet temperature Catalyst activity (replacement)  Periodic testing, portable analyzers 46

NO x Control Techniques – Water or Steam Injection  General description Water or steam injected in combustion zone reduces temperature and nitrogen oxide formation (applied to gas turbines) Only thermal nitrogen oxides reduced Reductions range from 60 to 80 percent 47

NO x Control Techniques – Water or Steam Injection - Schematic 48

NO x Control Techniques – Water or Steam Injection Compliance monitoring  Outlet nitrogen oxide concentration (CEMS)  Parametric monitoring Water to fuel ratio  Correlated to testing Fuel bound nitrogen concentration (low priority)  Periodic performance testing 49

NO x control – Low-NO x burners  Designed to control fuel and air mixing at the burner Staged combustion in a larger flame Reduced O 2 at hottest part of flame Reduced overall flame temperature Complete combustion in third stage  Often used with flue gas recirculation  NO x reductions of ~75 percent possible 50

Low NO x burner 51

NO x control – Low-NO x burners Performance monitoring  NO x concentration (CEMS)  Parametric monitoring Periodic testing and inspections Inspection and maintenance  Daily - flame failure detector, A/F recordings  Weekly - igniter and burner operation  Monthly - fan, fuel safety shutoff, interlocks, fuel pressure  Annually – system-wide, instrument calibration 52

Take-aways about NO x control device monitoring:  What can we say about CEMS for monitoring NO x emissions?  If not CEMS, which operating parameters are appropriate for monitoring compliance for Water or steam injection? Low NO x burners 53

Monitoring raw material or fuel pollutant content limits  Sulfur in coal or oil ASTM fuel analysis per lot of fuel – S, heat content Monthly records of fuel use – tons, barrels Calculate emissions rate  THC/OHAP in coatings or solvents Method 24 analysis of each coating or solvent (may be from vendor) Monthly records of use Calculate emissions or verify compliance 54

Monitoring work practices or design specifications  Work practice for dust control or liquid spillage Describe practices (e.g., sweep road, water spray, remove spillage, contain waste) and frequencies Define inspection frequencies Record inspections, maintain logs  Maintain design criteria (e.g., seals on floating roofs) Describe inspections and measurements with frequencies (e.g., annual rim seal checks, weekly visual inspections) Record results and maintain logs 55

Monitoring process operations (no add-on controls)  Chemical processes (THC/OHAP emissions) Periodic emissions testing  Annual performance test  Quarterly portable analyzer checks Process parameter monitoring  Temperature on condenser  Flow rates Equipment integrity inspections  LDAR  Capture fans and shrouds  Suppression or spraying equipment 56

Monitoring process operations (no add-on controls)  Combustion practices for PM control Periodic emissions testing - may tier testing frequency to margin of compliance, for example  Annual if ER > 90 % limit  Two to three years if %  Five years if ER < 60 % Inspections and parameter monitoring  Opacity (e.g., daily VE checks)  A/F ratio  Fuel or waste charge input rate  Equipment (e.g., burners) inspections 57

Summation  THC/OHAP Control Techniques  PM Control Techniques  Acid Gas Control Techniques  NO x Control Techniques  Passive control measures 58

What do you want to talk about? Multiclone PM collector 59

Thanks – we appreciate your time and attention! Contact the Measurement Policy Group, SPPD, OAQPS early and often as you work on your source category rules