Safecom's proven patented SYNERGY-2, DPS Ver 4 & Integrated Power Booster turns existing CATV networks into a super power synergy platform that provide.

Slides:



Advertisements
Similar presentations
Safecom's proven patented DPS Ver. 4 & Integrated Power Booster (Patent P) turn existing coax or power cable lines into dynamic super power highways that.
Advertisements

Safecom INGRESS GATE technology (Patent p) 28dB UPSTREAM RF & INGRESS NOISE BLOCKER Solving the “Funneling Effect” at HFC & RFoG networks Allows carrier.
Safecom INGRESS GATE technology (Patent p)
Frankfurt (Germany), 6-9 June 2011 André Postma – Netherlands – RT.1b SM components "Smart Grid Components"
Safecom's proven patented DPS Ver 4 & Integrated Power Booster (Patent P) turns existing coax or power cables lines into dynamic super power highways that.
Uninterruptible Power Supply (UPS)
AMI & Grid Data Analytics & Analysis Management Platform Page  1 What does this platform offer? Our tool is a next generation grid management software.
1 SAFECOM & HTC Smart Grid Patented technology providing complete set of unlimited backup Power for CATV networks & Without Batteries US PATENT 8,415,822.
Vendor Briefing May 26, 2006 AMI Overview & Communications TCM.
SmartGridCity™: A blueprint for a connected, intelligent grid community Presented to the Utah Public Service Commission May 13, 2009.
1 SAFECOM & HTC Smart Powering Grid Patented technology, providing a complete set of unlimited backup Power for CATV networks & Without Batteries US PATENT.
1 Pacific Gas & Electric Company MTS: Evolution of the Electric Distribution System Manho Yeung, Senior Director, System Planning and Reliability PG&E.
Amplifier in Wireless World Prepared by :Reem R. Hussein Prof. Issam Rashid Ashqer An-Najah National university Faculty of science Physics department.
ABB LCC ECS - 1 © 2004  Industrial IT Power Management System Scope & Value Proposition Lead Competence Center Electrical Control Systems.
Transformer SONNY P. DE LEON MT 1.
EET 450 – Advanced Digital Chapter 24 Power. Power Supplies Power conversion Performs a voltage conversion from either 120vAC to desired or 12vDC to desired.
Delta Confidential DES UPS introduction UPS training June 2006 Markus Schwab.
Safecom's proven patented SYNERGY-2, DPSV4, Power Booster & Dual T-former P.S turns existing CATV networks into a super power synergy platform that provide.
Assembling the Parts of the Puzzle: “Interoperability” is What Makes Them Fit Together John Jimison Managing Director Energy Future Coalition.
Phaseo Power Supplies ACE Expert Training Presentation 2009.
Chapter 8 COMMUNICATION AND COMPUTER NETWORK
Safecom INGRESS GATE technology (Patent p) UPSTREAM RF & INGRESS NOISE BLOCKER Solving the “Funneling Effect” at HFC & RFoG networks.
Terry Chandler Power Quality Inc, USA Power Quality Thailand LTD Sept /6/20091www.powerquality.org all rights reserve.
SCADA and Telemetry Presented By:.
THE TRES AMIGAS SUPERSTATION Southwest Renewable Energy Conference Santa Fe, NMSeptember 16 th 2010 UNITING THE NATION’S ELECTRIC POWER GRID.
SUSTAINABLE ENERGY REGULATION AND POLICY-MAKING FOR AFRICA Module 13 Energy Efficiency Module 13: SUPPLY-SIDE MANAGEMENT.
SAFECOM & HTC Smart Grid Patented technology providing complete set of unlimited backup Power for CATV networks & Without Batteries US PATENT 8,415,822.
Generating and Using Electricity
Future of Smart Metering Kansas Renewable Energy & Energy Efficiency Conference September 26, 2007.
AC backup solutions for business continuity. Secure your business, Stay on!
InnovationValueTeamwork SHENZHEN INVT ELECTRIC CO., LTD.
Surge current protection using superconductor
Golden Valley Electric Assoc. Inc © 2012 GVEA. All rights reserved. GVEA BESS Expected and Actual Performance Dan Bishop Golden Valley Electric Assoc Fairbanks,
Module 5, Unit A Vocabulary Review Game. 2 pt 3 pt 4 pt 5pt 1 pt 2 pt 3 pt 4 pt 5 pt 1 pt 2pt 3 pt 4pt 5 pt 1pt 2pt 3 pt 4 pt 5 pt 1 pt 2 pt 3 pt 4pt.
Modern approaches to developing hardware and software system for operation and emergency control of large-scale power grid A.B. OSAK, A.V. DOMYSHEV, E.Y.
Chapter 11 Bruce Gaffield Randy Binns Scott Thrush Kristi Partney Edited by Richard Goldman.
Frankfurt (Germany), 6-9 June 2011 Smart Grid Protection in China Wu Guopei Guangzhou Power Supply Bureau Guangdong Power Grid, China.
Power IT Solution in KEPCO. com Contents Introduction 1 EIS in KEPCO 2 Results of EIS 3 Future Expansion 4 You can briefly add outline.
Chapter 6 Voltage Regulators By En. Rosemizi Bin Abd Rahim EMT212 – Analog Electronic II.
Unit 3 REACTIVE POWER AND VOLTAGE CONTROL.  BASIC REQUIREMENTS OF EXCITATION CNTRL  Excitation Current up to 10’000 amps  Input frequency range from.
Wind Energy. How does wind energy work? The wind blows on the blades and makes them turn. The blades turns a shaft inside the nacelle (the box at the.
Introduction to Power Supplies
Intermediate Course (3) Technical Basics - 2 Circuits Karl Davies East Kent Radio Society EKRS 1.
Effect Analysis of Electric Vehicle Charging to Smart Grid with Anti-Islanding Method Bum-Sik Shin, Kyung-Jung Lee, Sunny Ro, Young-Hun Ki and Hyun-Sik.
Local Network OFF LEFT UNIT AC-1R LOCAL OFF AC-1L LOCAL OFF AC-2L Remote OFF MAIN-OFF DPS OFF Local Network OFF RIGHT UNIT Press to start AC2 pass only.
EMT212 – Analog Electronic II
SMART GRID A smart grid for intelligent energy use. By: Suhani Gupta.
Smart Grid Schneider Electric Javier Orellana
The following pages contain a number of architectural designs that can be applied to a broadband network. The application of the SPSM in a network is limited.
Transforming the Distribution Grid
2/June/2009LHCb Upgrade1 Single ended ADC Differential ADC –Convert single ended signal to differential (use AD8138 amp) –ASIC differential output ADC.
Commercial in confidence | © 2013 Technetix Technetix Group 3 October 2013 The future of cable broadband The future proof access platform SCTE Balkan Broadband.
DC/DC Converter. Innovative products for industrial automation Stabilize control voltages in 24 V DC systems Compact and powerful DC/DC converters for.
Smart Grid PRESENTED BY: ZUBAIR AHMAD
Exit REMOTE POWER SYSTEM ”Turning your copper into gold”
The Ideal Op-amp (Operational amplifier) v+ VOUT v– +15V VIN VOUT –15V
Uninterruptible Power Supply (UPS)
Subject Name: LINEAR INTEGRATED CIRCUITS Subject Code: 10EC46
A Novel Fault Current Limiter
Safecom INGRESS GATE technology (US,EP Patent) 28dB UPSTREAM RF & INGRESS NOISE BLOCKER Solving the “Funneling Effect” at HFC & RFoG networks Allows carrier.
Harsh Environment Power Conditioning Voltage Regulator
Flexible Transport Networks
Innovation in CATV powering design
Outdoor Power Conditioning Voltage Regulator
Indoor Power Conditioning Voltage Regulator
Speaker : Yu-Ping Chen Advisor : Quincy Wu Date : 2010/01/17
Outdoor Power Conditioning Voltage Regulator
Harsh Environment Power Conditioning Voltage Regulator
Indoor Power Conditioning Voltage Regulator
Presentation transcript:

Safecom's proven patented SYNERGY-2, DPS Ver 4 & Integrated Power Booster turns existing CATV networks into a super power synergy platform that provide most reliable and economic powering system and unlimited backup time. Safecom Smart Grid technology for Providing unlimited backup Power for CATV networks. DPS v4 Power Booster 4G SYNERGY-2

Based on the strategic placing of intelligent power management devices throughout the network, in the event of a power outage the SYNERGY-2 & DPS4 draws power from the nearest available source over existing coax or power cables. Utilizing breakthrough direct AC/AC stabilize technology safecom's SYNERGY-2 and Power Booster ensures an optimal voltage level – even over long distances. The concept.

What is DPS- Ver 4 ? A two-way RF Pass 1GHZ passive device that “toggle” available power between two distant locations. Redirecting power from the "normally" remote powered area, to the area subject to power outage. During the normal mode of operation, when there is no power outage at either end of the pair, the DPS v4 act as power block to the other side.

What is Power Booster? A Passive,Stand alone element that solving the voltage drop distribution problem in the CATV network caused by high-resistance and low energy- efficient coax & electricity cables. Ensuring an optimal voltage level at remote powered area, to the area subject to power outage or long distance powering. t Vin 42-87V Vac (US) Vin 30-64V Vac (EU) v t v Vout 87 Vac (US) Vout 60 Vac (EU) Based on a voltage management of novel AC/AC transformation technology with adaptive, universal conversion ratio that enables Smooth transition (Zero crossing) between conversion levels.

All in One two-way RF Pass 1GHZ passive device that “toggle” available power between two distant locations. Redirecting power from the "normally" remote powered area, to the area subject to power outage. During the normal mode of operation, when there is no power outage at either end of the pair, the SYNERGY-2 act as power block to the other side. Utilizing breakthrough step-up & stabilizing voltage technology the unit provides optimal & stable voltage level from local or remote P.S even from very long distance or using a un-stabilized P.S. What is SYNERGY-2? =+ SYNERGY-2 ( NEW) DPS V 4Power Booster

Inputs/ Outputs configuration RF+AC To local amplifier / Optical node RF+AC To local amplifier / Optical node RF +AC To /Form Remote amplifier / Optical node RF +AC To /Form Remote amplifier / Optical node AC input 1 AC input 2 Monitoring outputs Online voltage Online current Status Monitoring outputs Online voltage Online current Status Inside view : SYNERGY-2 60/87V -2x15A

SYNERGY 2 the New generation.

Power Booster – the 4G Transmission

SYNERGY-2 Typical configuration Optical node + Trunk amplifier (or second optical node). Power + Signal From Optical node AC 2 input. AC 2 input Local output to local Optical Node.(AC+RF) Backup IN.OUT (AC+RF to remote Node/ amp) Power + Signal Optical Node To remote / amplifier / Node P.S.S P.S 60V Trunk amplifier Or Optical Node 60V Area A Area B

From Optical node AC 2 input. AC 2 input Local output to local Optical Node.(AC+RF) Backup IN.OUT (AC+RF to remote Node/ amp) Power + Signal Optical Node To remote / amplifier / Node P.S.S P.S SYNERGY-2 – Demo backup power from Area A to Area B Power + Signal Trunk amplifier Or Optical Node 60V 55V 50V 45V 40V60V 40V 60V Area A Area B

Power + Signal To Optical node AC 2 input. AC 2 input Local output to local Optical Node.(AC+RF) Backup IN.OUT (AC+RF to remote Node/ amp) Power + Signal From remote amplifier / Node P.S.S P.S Optical Node 40V 45V 50V 55V 60V 40V 60V Trunk amplifier Or Optical Node SYNERGY-2 – Demo backup power from Area B to Area B P.S Area A Area B

DPSv4 replaces standby power supply

13 Power backup Comparisons Synergy-2 / DPS V4 GeneratorsNon Standby Standby + Batteries Power Type LowHighLowHighCost ZeroPermanentNegligiblePermanentMaintenance UnlimitedLimited by fuelNone2 to 3 hour (Depends on batt. condition ) Backup Power Low cost Very expensiveLowVery ExpensiveRedundant/ Diversity

Typical optical network powering examples

90V-network 60V-available

60V-network 90V-available

Business case. Improving customer service and satisfaction. Enabling MSO to add new services that required top high reliability. Unlimited backup time. Reducing dramatically CAPEX & OPEX. Increasing powering efficacy & save energy.

Summery SAFECOM SYNERGY-2 & DPSv4 offers most efficient and reliable backup for unlimited time. No additional cost for MSO further to the fact that SYNERGY-2 / DPS v4 unit can be reuse from old HFC network. All existing Coax and power cables can be reuse for backup the new optical networks. Following the government regulation for full powering backup. SYNERGY-2,DPSv4 & Power Booster systems enabling additional backup from remote powering. No maintenance. Unlimited life time.

Thank you