2/24/00 All information contained herein is confidential and may not be disclosed to any third party without the written consent of SLC Technologies Europe.

Slides:



Advertisements
Similar presentations
VSA Series VSA Series The Next Generation of Vault Sound Alarms.
Advertisements

INTRUSION ALARM TECHNOLOGY
ASF Leak Detectors – New Design Präsentation neuer LAG Newsletter.ppt 1 After our previous device models are used for nearly four decades in more than.
All purpose professional emergency lighting. Ceiling mounting. Beghelli Formula 65 is equipped with a symmetric reflector which makes it suitable for.
HARPER CHALICE GROUP LIMITED 8 Binns Close Coventry CV4 9TB United Kingdom Telephone Fax harperchalice.co.uk.
How Electronic Security Solutions can Help the Government in Securing its Assets and Reduce Energy expenditure Presented By- Nimish Vishnoi Manager-Product.
PYROCON12 De-Ice controller Technician Operation Presentation 2013.
HARPER CHALICE GROUP LIMITED Leading manufacturers and suppliers of Electronic and Electrified “Perimeter Intrusion Detection systems” PulseSecure™ PROTECTOR.
Motorcycle product sheets
ELECTRONIC GUIDING CANE FINAL PRESENTATION Students : David Eyal Tayar Yosi Instructor : Miki Itzkovitz Technion – Israel Institute Of Technology Electrical.
IQ ™ Overspeed protection.. and more.
Getting Started Product Description Setting Parameters How does it work Wiring Diagram.
MOBILELOCK™ GPS Locator with Anti-theft Alarm Copyright © 2008 D E WALT. All rights reserved.
Application Notes for Frequency Division Multiplex System Testing with ET 91 To learn more click on note! Basic, Super & Master Group Voice Frequency Noise.
Motorcycle antitheft systems Spyball 6500 platform Benefits 6500 Description: compact motorcycle antitheft alarm and engine immobiliser. Arming/disarming.
Chapter 5 Enhancing Security Through Physical Controls
GST FIRE ALARM SYSTEM INTERNATIONAL BUSINESS DEPARTMENT , GST BEIJING
BHEL / Ranipet Areas For Development And Commercialization Entrepreneurship Awareness Camp December-2006.
Siemens sans siemens sans bold siemens sans italic siemens sans italic bold siemens sans black siemens black italic Siemens Building Technologies.
1 Patron Queuing System Team Gong Archit Agarwal Thanh Nguyen Adnan Salam.
1 Advanced Sensors Lecture 6 Sensors Technology AUE 2008 Bo Rohde Pedersen.
Av-Gad Promo 2010 Av-Gad ATM & Bank Protection Av-Gad Promo 2010 SesMo is a combined seismic detector used to protect bank safes, media safes, strong.
Av-Gad Promo 2013 Av-Gad Automatic food machines Protection.
1 INTRUSION ALARM TECHNOLOGY DETECTION DEVICES. 2 INTRUSION ALARM TECHNOLOGY Detection devices can be either passive or active. Passive devices typically.
Security Devices A modern security system, with its array of electronic components, is designed to sense, decide, and act. The security system senses events.
Metra Mess- und Frequenztechnik Radebeul / Germany Piezoelectric Accelerometers Theory & Application.
Activated by the control panel, it gives a loud audio signal to alert that an intrusion has occurred.
The Northern California Section of the Instrumentation, Systems, and Automation Society Smart Positioners – Features n Mario Francisco – CFM Inc The TZID-C200.
ABB Signal Easy solutions
Principles of Computer Security: CompTIA Security + ® and Beyond, Third Edition © 2012 Principles of Computer Security: CompTIA Security+ ® and Beyond,
FG Glassbreak Sensor Training
InSeT System Inertial Sensor Tracking System Underground Mine Safety For Personnel Utilizing Inertial Sensors Technical Presentation.
All information contained herein is confidential and may not be disclosed to any third party without the written consent of Interlogix Europe & Africa.
Joseph Kälin direct: , mobil: For your customers: MICRONOR Fiber Optic Product.
INTRODUCTION 1 What word comes to your mind to describe “ The attempt by two objects to occupy the same space at the same moment in time”
1 PAC530 | Output Controller. 2 The Output Controller (PAC530) provides the local connection on an RS-485 network between an Access and Alarm Server (PAC500)
Why………….? coz Speed thrills but Kills! Why Should Speed Governor / Limiter be Installed.
External perimeter protection Active Infra Red Motion sensors
Single Ended Measuring Modes of ELQ 30A To learn more click on the selected topic! ELEKTR NIKA Receiving Modes Impulse Noise Measurement Spectrum Analyzer.
Page 1 Onity OS Series Safes 20/03/2003. Page 2 Onity OS Series Safes 20/03/2003 Onity OS Series Safes.
The Detection Series to Envy.
3-Phase Submersible Motor Control
2 IMPACT - THE FIRE PERMIT = Hot Work Permit 3 Welcome ! This course is linked to the use of IMPACT, so it is assumed that: You know how to use IMPACT.
All information contained herein is confidential and may not be disclosed to any third party without the written consent of SLC Europe & Africa More Than.
Launch Chameleon Plus P - More Preventive features and safety L - More Longer Lasting and robust U - More User friendly operation S - More Service friendly.
CUE – Make Any Pump an E-Pump
Frequency Division Multiplex System Testing with ET 92 To learn more click on note! Basic, Super & Master Group Voice Frequency Noise END to END Measurements.
Manual Measuring Modes of ELA 10 To learn more click on the selected topic! Level, Loss Noise, Spectrum Line Parameter Optional Measurements Transmitting.
INDUSTRIAL SENSORS Inductive Proximity Sensors. INDUSTRIAL SENSORS Inductive Sensors - Operating Principle Switching amplifier Signal evaluator LC oscillating.
Physical Security Concerns for LAN Management By: Derek McQuillen.
HOT CAR BABY DETECTOR Group #20 Luis Pabon, Jian Gao ECE 445 Dec. 8, 2014.
SERVICE TRAINING EXPERT ALPHASTAR 1132 © MAO-SE-TC 1132_SE_EX_Handout_EN_12_  Collision protection switch  Collision protection switch retrofit.
Physical Security Ch9 Part I Security Methods and Practice CET4884 Principles of Information Security, Fourth Edition.
Lego Mindstorm Robots 9797 kit.  Students will learn how to identify how to detect a change in a condition.  Students will learn where and how to identify.
LOGO Electronic Volume Converter TZ, PTZ ”Flougas-T”
Strong room Vaults How do vault doors work  Strong room vaults are a kind of safes meant to protect your valuable assets from burglary, theft and fire.
Single Ended Measuring Modes of ELQ 30A+
C1300 advanced circular chart recorder
SECURITY FEATURES OF ATM
Copyright SwissFlow B.V.
2N® Access Unit Touch Keypad
Enclosed Parking Ventilation 1 EK Engineering (India) CO/NO2 detection, Fan Control and automation System E: Mobile:
InSeT System Inertial Sensor Tracking System
Feature Benefit Feature Benefit Feature Benefit Feature Benefit
2N® Access Unit Touch Keypad
Digital Motion Detector
SAFES FOR HOME AND OFFICE.
Technician Operation Presentation
ALL-ELECTRIC TEMPERATURE CONTROL FOR CHILLED, FROZEN AND
2N Access Unit 2.0 Multi-technology access control readers.
Presentation transcript:

2/24/00 All information contained herein is confidential and may not be disclosed to any third party without the written consent of SLC Technologies Europe & Africa Detection Business Unit Aritech Seismic detectors VV600 Plus & VV602 Plus

2/24/00 All information contained herein is confidential and may not be disclosed to any third party without the written consent of SLC Technologies Europe & Africa Detection Business Unit VV600 Plus & VV602 Plus The VV600 Plus series is the next generation development based on proven high technology electronic processing with excellent secure detection without false alarms.

2/24/00 All information contained herein is confidential and may not be disclosed to any third party without the written consent of SLC Technologies Europe & Africa Detection Business Unit Two different detector models VV600 Plus –for protection of safes, vaults, steel cabinets etc. VV602 Plus –for protection of public applications like ATM’s (cash dispensers) and night safe deposit boxes.

2/24/00 All information contained herein is confidential and may not be disclosed to any third party without the written consent of SLC Technologies Europe & Africa Detection Business Unit New features & improvements Upgraded electronics, 100% SMT, and detection algorithms New fresher look of the cover. The cover is only mounted with one screw. New drill protection covers the whole detector. New test system.

2/24/00 All information contained herein is confidential and may not be disclosed to any third party without the written consent of SLC Technologies Europe & Africa Detection Business Unit New features & improvements Extremely low current consumption, 25mA  8mA Only one micro switch for both tamper and pry-off protection. Two spare screw terminals. Improved tamper protection at the cable inlet.

2/24/00 All information contained herein is confidential and may not be disclosed to any third party without the written consent of SLC Technologies Europe & Africa Detection Business Unit Function & applications VV600/602 Plus

2/24/00 All information contained herein is confidential and may not be disclosed to any third party without the written consent of SLC Technologies Europe & Africa Detection Business Unit First back to basic Acceleration = gravity = m/s² Amplitude = signal strength Frequency = Hz = Periods/sec. = 1 kHz = 1 Hz/sec

2/24/00 All information contained herein is confidential and may not be disclosed to any third party without the written consent of SLC Technologies Europe & Africa Detection Business Unit Frequency range between kHz Frequency Signal 6 kHz20 kHz Detection area Ultrasonic detectors

2/24/00 All information contained herein is confidential and may not be disclosed to any third party without the written consent of SLC Technologies Europe & Africa Detection Business Unit Signal characteristics of a true break-in attempt Explosive means - high amplitude, short signal duration Mechanical destruction & rotating devices - moderate to high amplitude, long signal duration Thermal devices - low amplitude, long signal duration

2/24/00 All information contained herein is confidential and may not be disclosed to any third party without the written consent of SLC Technologies Europe & Africa Detection Business Unit Principles of operation Piezo electric sensor convert vibrations (acceleration) to electrical signals Advanced three channel signal processing Signal processor will analyse the following three parameters simultaneously: –Signal strength (amplitude) –Signal frequency –Signal duration

2/24/00 All information contained herein is confidential and may not be disclosed to any third party without the written consent of SLC Technologies Europe & Africa Detection Business Unit Schematic diagram of VV600 Plus

2/24/00 All information contained herein is confidential and may not be disclosed to any third party without the written consent of SLC Technologies Europe & Africa Detection Business Unit VV600 Plus signal processing channels Integration channel –Will detect all kinds of rotating and thermal tools –Will not detect back-ground noises –Five different sensitivity settings –Will reset gradually to base level Alarm level Signal duration Amplitude –Frequency = 6-20 kHz –Acceleration = >0,1 m/s² –Time = max 40 sec

2/24/00 All information contained herein is confidential and may not be disclosed to any third party without the written consent of SLC Technologies Europe & Africa Detection Business Unit VV600 Plus signal processing channels Counting channel –Detects all mechanical attack devices like sledge, hammer, hydraulic jack etc. –Will give an alarm after 5 pulses –Reset time 3 min –The sensitivity is pre-set –Frequency = 1-20 kHz –Acceleration = >10 m/s² –Time = 5 true pulses Signal duration Amplitude Alarm

2/24/00 All information contained herein is confidential and may not be disclosed to any third party without the written consent of SLC Technologies Europe & Africa Detection Business Unit VV600 Plus signal processing channels Explosion channel –Detects all explosions –Trigger an alarm after a pre-set limit –100 x lower sensitivity than a shock sensor –Frequency = 1-20 kHz –Acceleration = > 400 m/s² –Time = 20 Millie sec Signal duration Amplitude Alarm level

2/24/00 All information contained herein is confidential and may not be disclosed to any third party without the written consent of SLC Technologies Europe & Africa Detection Business Unit VV602 Plus for special applications The objects are frequently used by the public, even 24 hours a day. The objects are creating vibrations and knockings by their normal operation.

2/24/00 All information contained herein is confidential and may not be disclosed to any third party without the written consent of SLC Technologies Europe & Africa Detection Business Unit Schematic diagram of VV602 Plus

2/24/00 All information contained herein is confidential and may not be disclosed to any third party without the written consent of SLC Technologies Europe & Africa Detection Business Unit VV602 Plus signal processing channels Low integration channel –Will detect thermal, rotating and mechanical tools –Alarm will not be triggered by internally generated vibrations of the ATM e.g. printer, note counter and note dispenser –Will reset by an interruption of the signal Alarm level Signal duration Amplitude –Frequency = 6-20 kHz –Acceleration = >0,15 m/s² –Time = 5-15 sec

2/24/00 All information contained herein is confidential and may not be disclosed to any third party without the written consent of SLC Technologies Europe & Africa Detection Business Unit VV602 Plus signal processing channels High integration channel –Will detect rotating and thermal attack type tools –Alarm will not be triggered by internally generated vibrations of the ATM –4 x lower sensitivity than the low integration channel –Integrates only signals that continues after 5 sec. –Frequency = 6-20 kHz –Acceleration = > 1 m/s² –Time = 5-15 sec Signal duration Amplitude Alarm level 5 sec

2/24/00 All information contained herein is confidential and may not be disclosed to any third party without the written consent of SLC Technologies Europe & Africa Detection Business Unit VV602 Plus signal processing channels Explosion channel –Detects all explosions –Trigger an alarm after a pre-set limit –100 x lower sensitivity than a shock sensor –Frequency = 1-20 kHz –Acceleration = > 400 m/s² –Time = 20 Millie sec Signal duration Amplitude Alarm level

2/24/00 All information contained herein is confidential and may not be disclosed to any third party without the written consent of SLC Technologies Europe & Africa Detection Business Unit Why should you use a seismic detector? No safe or strong room is impenetrable. Using the VV600/602 Plus gives a 24 hour surveillance without restricting the activity around the protected object. Early warning gives more time for counter actions. Early warning will reduce costs for an attack in more than one way.

2/24/00 All information contained herein is confidential and may not be disclosed to any third party without the written consent of SLC Technologies Europe & Africa Detection Business Unit Areas of application Banks and Post offices: Military installations: Pharmacies, Hospitals: Museums, Jewellers shops: Offices: –Vaults and safes –ATM –Night safe deposit boxes –Arms & munitions stores –Steel gates and doors –Drug cabinets –Display cases & safes –Data and filing cabinets

2/24/00 All information contained herein is confidential and may not be disclosed to any third party without the written consent of SLC Technologies Europe & Africa Detection Business Unit Installation & planning guide-lines for VV600/602 Plus

2/24/00 All information contained herein is confidential and may not be disclosed to any third party without the written consent of SLC Technologies Europe & Africa Detection Business Unit Wiring diagram VV600/602 Plus

2/24/00 All information contained herein is confidential and may not be disclosed to any third party without the written consent of SLC Technologies Europe & Africa Detection Business Unit Detection range of the VV600/602 Plus

2/24/00 All information contained herein is confidential and may not be disclosed to any third party without the written consent of SLC Technologies Europe & Africa Detection Business Unit Planning a vault protection with VV600 Plus General rule; one detector on each wall, floor and ceiling inside the vault and one detector on/ inside the vault door. It is recommended to do a layout plan to define the location of each detector.

2/24/00 All information contained herein is confidential and may not be disclosed to any third party without the written consent of SLC Technologies Europe & Africa Detection Business Unit Protection of a vault Using a recess mounting box VM602P ensures the best coverage, as the detector is anchored in the reinforcement bars of the concrete.

2/24/00 All information contained herein is confidential and may not be disclosed to any third party without the written consent of SLC Technologies Europe & Africa Detection Business Unit Planning protection of a safe or filing cabinet with VV600 Plus Most of the attacks against safes are aimed at the door and the locking mechanism. The hinges reduces the signal between the door and the body. For highest security: –one detector on the door –one detector on the body

2/24/00 All information contained herein is confidential and may not be disclosed to any third party without the written consent of SLC Technologies Europe & Africa Detection Business Unit Protection of a safe Moveable mounting plate VM651P –Detector on the night position plate makes it impossible to opened the door. Keyhole protection kit VM652P –Stops the intruder from inserting stolen keys and explosives.

2/24/00 All information contained herein is confidential and may not be disclosed to any third party without the written consent of SLC Technologies Europe & Africa Detection Business Unit Planning protection of ATM’s & night safe deposit boxes with VV602 Plus Always use the VV602 Plus for public applications to avoid false alarms. Most attacks are aimed at the door and the dispenser opening. Detectors

2/24/00 All information contained herein is confidential and may not be disclosed to any third party without the written consent of SLC Technologies Europe & Africa Detection Business Unit Testing system VT705P - built in test transmitter –Daily test of the detector provides the highest level of security. –Mounted on its own mounting bolt, enables test of the detector’s electronics and its physical contact to the protected object. VT610P - hand held tester –Can be used to test permanent systems and to verify the installation.

2/24/00 All information contained herein is confidential and may not be disclosed to any third party without the written consent of SLC Technologies Europe & Africa Detection Business Unit Two ways of testing with the test transmitter Test disabled (factory setting)  Internal test of the detector’s electronic  Function test of the detector and its physical contact to the protected object with VT705P 

2/24/00 All information contained herein is confidential and may not be disclosed to any third party without the written consent of SLC Technologies Europe & Africa Detection Business Unit Control & function test Control function and mounting of the detector by using a potentiometer and the hand-held tester VT610P

2/24/00 All information contained herein is confidential and may not be disclosed to any third party without the written consent of SLC Technologies Europe & Africa Detection Business Unit Upgraded accessories Complete range of accessories for all kinds of applications.

2/24/00 All information contained herein is confidential and may not be disclosed to any third party without the written consent of SLC Technologies Europe & Africa Detection Business Unit Planning guide-lines Don’ts…. –Don’t assume that covered concrete walls are free of cracks. –Don’t install sensors permanently before determine sensitivity settings and ambient noise level. –Don’t install the detector on unproved masonry surface without contacting Aritech. –Don’t mount the detector on rough surfaces, sand first. –Don’t allow the test transmitter VT705P to have contact with the mounting plate or the detector.

2/24/00 All information contained herein is confidential and may not be disclosed to any third party without the written consent of SLC Technologies Europe & Africa Detection Business Unit Summary Will detect all known methods of attacks Will not react to normal background noises Will detect any attack within a minimum of 4 meter radius Sensitivity can be set in five steps for optimum performance in any installation High immunity against RFI and EMC Complete line of accessories Easy installation

2/24/00 All information contained herein is confidential and may not be disclosed to any third party without the written consent of SLC Technologies Europe & Africa Detection Business Unit Thank you for your attention. Any questions?