PUMPING SYSTEMS BASICS

Slides:



Advertisements
Similar presentations
Fire Apparatus Pump Theory
Advertisements

Fluid Mechanics.
CE 382, Hydraulic Systems Design (pipes, pumps and open channels) Principles of hydraulics 1.Conservation of energy 2.Continuity (conservation of mass)
Wastewater Collection (Sewer Alternatives). Sewer Basics Collection and transport of wastewater from each home/building to the point where treatment occurs.
DRIP DISPERSAL SYSTEMS Problems and Solutions Presented by Keith Surface.
Introduction to Septic Tanks John R. Buchanan, Ph.D., P.E. University of Tennessee.
DRIP DISPERSAL SYSTEMS Problems and Solutions. Flow Equalization Surges in the ATU during peak loading are a major cause of filter clogging in a drip.
Design of W.W. Collection System
UL/FM Fire Pump Systems Lunch & Learn 04/18/05
Chapter 3.1 Storm Drainage Sizing. Building Drain & Sewer  Building Drain —That part of the lowest piping of a drainage system that receives the discharge.
Flow Equalization Tanks Presented by Keith Surface.
For The Driver Operator
Fluid Mechanics 07.
Cycle Stop Valves 1” through 16” 1 GPM to 10,000 GPM.
Booster System Basics: Constant Speed Systems
Chapter 3.1 Storm Drainage Sizing. Building Drain & Sewer  Building Drain —That part of the lowest piping of a drainage system that receives the discharge.
HYDRAULIC DESIGN.
Select the Appropriate Pumps and Controls. © Irrigation Association Understanding Basic Pump Selection Considerations Matching the pump and system Flat.
Biet Qad Village Climate Relative Humidity Evaporation.
PA DEP Bureau of Deep Mine Safety
Basic Hydraulics of Flow (Pipe flow, Trench flow, Detention time)
Math Midterm Review Math for Water Technology MTH 082.
Math Final Exam Review Math for Water Technology MTH 082.
Flushing. Annual flushing is enough for many systems, but some water and emitter combinations require almost daily flushing to control clogging. If frequent.
Centrifugal Pump Basics Terms commonly used in the pumping industry.
Installing & Maintaining Irrigation Systems Ms. Gripshover Landscaping Unit 15.
Basic Hydraulics Irrigation.
STEAM HEATING.
Week 1 Unit Conversions Mass and Volume Flow Ideal Gas Newtonian Fluids, Reynolds No. Week 2 Pressure Loss in Pipe Flow Pressure Loss Examples Flow Measurement.
Assignment No. 1 [Grup 8] Figure below shows a portion of a hydraulic circuit. The pressure point B must be 200 psig when the volume flow rate is 60 gal/min.
MER Design of Thermal Fluid Systems Pumps and Fans Professor Anderson Spring Term
SEWER PIPING DESIGN Sewer piping differs from water piping, in that sewer pipes are not under pressure. The function that takes place inside sewer pipes.
Why do we need to treat wastewater ?
Conservation of Mass, Flow Rates
HVAC523 Circulator Pumps.
Week 1 Unit Conversions Conservation of Mass Ideal Gas Newtonian Fluids, Reynolds No. Pressure Loss in Pipe Flow Week 2 Pressure Loss Examples Flow Measurement.
Ways to express Bernoulli equation Energy per unit volume: Energy per unit mass: Energy per unit weight: - conservation of energy (no friction loss)
Pumps and Lift Stations. Background Fluid Moving Equipment Fluids are moved through flow systems using pumps, fans, blowers, and compressors. Such devices.
TEC 4607 Wind and Hydro Power Technologies Fall 2011.
TEC 4607 Wind and Hydro Power Technologies Fall 2011.
Landscape Irrigation Based upon the book Rain Bird Irrigation Design Manual.
Why is resource assessment important? It wont work without the resource! (Lawn ornament) It will not provide a return on investment without working! You.
Washington University ChE 433 Digital Process Control Laboratory Fluid Statics & Dynamics Lecture.
Technology in Architecture Lecture 14 Upfeed Systems Pipe Sizing Procedure Pipe Sizing Example Lecture 14 Upfeed Systems Pipe Sizing Procedure Pipe Sizing.
Microhydro Flow, nozzles. Site Assessment: Flow 5-gallon bucket –Small stream, small waterfall Float –Larger, flat, uniform stream V-notch Weir Rectangular.
Available Water Flow Meter Size Typical flow depending on size
Urban Storm Drain Design: Pump Performance Curves.
Introduction to Energy Management
CE 3372 Water Systems Design
Variable Speed Applied to Pumps. Life Cycle Costs - Courtesy of Hydraulic Institute and Europump Initial cost is not the only cost associated with a pump.
CE 3372 Water Systems Design Lecture 18: Storm sewers, inlets, conduits and related hydrology and hydraulics.
Water Management Water is an important natural resource that requires proper management. Appropriate flow rate, pressure, and water quality are necessary.
Friction Loss Tutorial Used in conjunction with the Friction Loss Check Sheet and any Irrigation Plan.
Pharos University ME 259 Fluid Mechanics for Electrical Students Revision for Final Exam Dr. A. Shibl.
SATMathVideos.Net Water is pumped into an tank at 20 gallons per minute. The tank has a length of 10 feet and a width of 5 feet. If the tank starts empty,
FLUID FLOW FOR CHEMICAL ENGINEERING Dr Mohd Azmier Ahmad Tel: +60 (4) EKC 212 CHAPTER 8 (Part 5) TRANSPORTATION SYSTEM.
SUGGESTED MINIMUM KNOWLEDGE OF FLUID MECHANICS AND FOR FE EXAM
Power – Energy Relationships
System One Pumps S1-200 Centrifugal Hydraulics
Domestic Hot Water Recirculation Design
Plumbing system fundamental and design course
Pumped Discharge. Brian Makin 14/
Design of Cold Water Networks
WATER DEMAND (Chapter 24)
L-9 Sewage Pumping Environmental Engineering-II.
Process Equipment Design and Heuristics - Pumps
Pumps and Lift Stations
Find: Q gal min 1,600 1,800 2,000 2,200 Δh pipe entrance fresh water h
Technology in Architecture
Presentation transcript:

PUMPING SYSTEMS BASICS

Effluent and De-watering (Sump pump) Waste Water Pump Types Effluent and De-watering (Sump pump) Sewage Pump (2” solids) Non-Clog (2 ½” solids) Grinder Pump

AUTOMATIC PUMPS NON-AUTOMATIC PUMPS Mechanical Switch Tethered Ball Float Switch Diaphragm Switch NON-AUTOMATIC PUMPS

Wide Angle Switches PIGGY BACK FLOAT SWITCH DOUBLE PIGGY BACK SWITCH

Control Switch

SIMPLEX SYSTEM Simplex Control Panel

DUPLEX SYSTEM Duplex Control Panel

BASINS Polyethylene Basin Fiberglass Basin

THREE BASIC QUESTIONS FOR SIZING: PUMP SIZING THREE BASIC QUESTIONS FOR SIZING: 1. HOW MUCH ( Demand) 2. HOW HIGH ( Static Head) 3. HOW FAR ( Friction Head)

Calculating System Demand ( HOW MUCH) POPULATION METHOD: Formula: ((NP x 100 gal/day/person x 4 )/24hrs/day )/60 min/hr. = GPM NP = population served. Number 4 is the peak flow factor Examples: 80 people in a sub-division. ((80 x 100 x 4)/24)/60 = 23 GPM.

Calculating System Demand FIXTURE COUNT METHOD: Each fixture in a building is given a “ unit weight”. The total “unit weight” of all the fixture in the building is referenced on a conversion graph and a gallons per minute flow is determined.

Static Head ( How High) Discharge Point Discharge Line Static Head = Elevation Change Static Head Pump

Friction Head ( HOW FAR) Discharge Point Discharge Line Friction head is determined by adding the total length of the discharge line (including fittings) then referencing a friction loss chart . Using the system demand flow and the size of the discharge pipe, the total head loss can be found. Pump TOTAL DYNAMIC HEAD = Static Head + Friction Head

Discharge Pipe Selection MINIMUM FLOW VELOCITY: In order to keep solids flowing in a horizontal pipe, a velocity of 2 ft. / sec. must be maintained. 2 ft./sec flow Pipe Suspended Solids Flow rates required to maintain 2 ft./sec: 2” pipe = 21 gpm 3” pipe = 46 gpm 4” pipe = 80 gpm

Discharge Volume Exchange To Find volume in Discharge line: Length of discharge ( ft.) X gal/ft. = Gal in Line Sewer Main Discharge Line Liquid Volume in Pipe: 2” = .17 gal/ft. 3” = .36 gal/ft. 4” = .65 gal/ft. Pump

Pump and System Curves Combined Pump and System Curves System Curve

Basin Sizing & Selection 1. Physical Dimensions : Will it Fit ?

Discharge Volume Exchange Liquid Volume in Pipe: 2” = .17 gal/ft. 3” = .36 gal/ft. 4” = .65 gal/ft. To Find volume in Discharge line: Length of discharge ( ft.) X gal/ft. = Gal in Line Basin Sewer Main Discharge Line Pump on Draw down Pump off Pump There should be enough draw-down to change the volume in the discharge line every cycle.

Discharge Volume Exchange Liquid Volume in Pipe: 2” = .17 gal/ft. 3” = .36 gal/ft. 4” = .65 gal/ft. To Find volume in Discharge line: Length of discharge ( ft.) X gal/ft. = Gal in Line Basin Sewer Main Discharge Line Pump on Draw down Pump off Pump There should be enough draw-down to change the volume in the discharge line every cycle.

Basin Sizing Calculations EXAMPLE: Commercial building with 50 gpm flow rate. Pump selected has a flow rate of 60 gpm. The pump height is 18” and the invert is 8”. The discharge line is 3” in diameter and 150 ft long. Step 1. Invert Distance - 8” Step 2. Pump Height - 18” Step 3. Draw down ( largest of the following ) a. Max starts – (( 50 gpm x 60 min )/ 6) x .4 = 200 gal/cycle 200 gal / 4.4 gal per inch = 45” b. Volume in discharge - .36 gal / ft x 150ft = 54 gal 54 gal / 4.4 gal per inch = 12” c. Pump run time : (60 gpm x 1 Min) / 4.4 gal per inch= 14 The total of all three critical dimensions is 71” The closest basin depth is 72”. Thus the suggested basin is 36 x 72. If this depth is too great for the application, then a wider basin can be used. This would result in a shallower basin.

Calculating Depth 36” diameter basin: Floor level 8” Invert Inlet pipe 45” (Draw down) Pump Note: This would result in a complete change of volume and a run time of 3.5min 18”

Residential Reality The preceding examples work well for commercial applications and for those residential applications serving the whole house. The reality is that most residential sewage applications serve just one, seldom used bathroom. In these applications the usage is so small that the pump protecting guidelines do not have the same importance. In these applications, a 2” solids pump and an 18 x 30 poly basin work very well.

VENTS AND AIR ADMITTANCE VALVES Related Topics VENTS AND AIR ADMITTANCE VALVES Vent to atmosphere Potential confined air Liquid Inflow Studor AAV Water level Incoming liquid displaces air, which is released through the vent. AAV’s prevent this release, causing the system to “air lock”.

Questions For Additional Information: Chris Beiswenger chrisb@zoeller.com (317) 670-9764