INDUSTRIAL SYSTEMS, INC.

Slides:



Advertisements
Similar presentations
Stakeholders Meeting June 22, 2011 Division of Building Safety Industrial Safety Elevator Program.
Advertisements

SOME OF THE MOST COMMON TESTING MISTAKES MADE BY TECHNICIANS PERFORMING VERIFICATIONS TO CAN/ULC The reason I know some of them is because I have.
NFPA 72 and NFPA 101 Supervised Automatic Sprinkler System Overview
Fired And Unfired Pressure Vessels
State Fire Marshal Question and Answer Session with the Louisiana Automatic Fire Alarm Association March 19, 1999.
Visit Us At Booth #306 J2 Engineering, Inc. J2 provides Construction and Environmental Services and is a verified Service-Disabled Veteran-Owned Small.
Field Operations and State-Managed Plugging Overview
DRIP DISPERSAL SYSTEMS Problems and Solutions Presented by Keith Surface.
ENVIRONMENTALIST II-B WATER RECLAMATION SYSTEM. GENERAL INFORMATION EV II-B A compact water recycling system designed to reduce water consumption and.
DRIP DISPERSAL SYSTEMS Problems and Solutions. Flow Equalization Surges in the ATU during peak loading are a major cause of filter clogging in a drip.
TRULY NOBLE SERVICES A Guide on how to Winterize a Property.
UL/FM Fire Pump Systems Lunch & Learn 04/18/05
Chapter 20 Plumbing Plans.
September 29-30, 2011 Drinking Water Program Sustained Compliance Workshop Lee Johnson, P.E
CAFS On-Line Orientation
Codes and Standards to be followed in the design and construction of the Green Energy facility National Fire Protection Assoc (NFPA); American Gas Association.
Rule Change Update MPCA 1/13/ Mid-Sized ISTS (MSTS)
BOB BROZ UNIVERSITY OF MISSOURI EXTENSION (573) ISE #78 WATER MANAGEMENT STRATEGIES FOR DROUGHT MITIGATION AND SUSTAINABLE AGRICULTURAL PRODUCTION.
ACCA Legislative Conference Underground Storage Tank Compliance
Chapter 3.1 Storm Drainage Sizing. Building Drain & Sewer  Building Drain —That part of the lowest piping of a drainage system that receives the discharge.
Gas Transmission Pipelines
Select the Appropriate Pumps and Controls. © Irrigation Association Understanding Basic Pump Selection Considerations Matching the pump and system Flat.
Aerial Apparatus Operator Types and Construction of Aerial Apparatus.
Student Book © 2004 Propane Education & Research CouncilPage Installing Manifold Cylinders or Tanks When installing manifold DOT cylinders.
Updates to NFPA 13 What’s New in the 2013 Edition Kenneth E. Isman, P.E., F.S.F.P.E. For the European Fire Sprinkler Network’s Fire Sprinkler International.
5.1.2 Student Book © 2005 Propane Education & Research CouncilPage 1 NFPA 58, LP-Gas Code, sets out the minimum valve and fitting requirements for propane.
© 2012 Ted “Smitty” Smith  This slide show contains multiple timed questions. All questions can be answered using the International Fire Code and the.
Fire Pump Functions The main function of a fire pump is to increase the pressure of the water that flows through it. Inadequate or nonexistent municipal.
5.1.5 Student Book © 2005 Propane Education & Research CouncilPage 1 Specific measures are required by the LP-Gas Code for the prevention of dispenser.
Pumps and Lift Stations. Background Fluid Moving Equipment Fluids are moved through flow systems using pumps, fans, blowers, and compressors. Such devices.
SPCC UPDATE Bob Beyke Milestone Contractors. State of Flux – No Longer Revised final rules published 7/17/02 Major issues with final rule - lawsuits Multiple.
5.1.9 Student Book © 2005 Propane Education & Research CouncilPage Installing Propane Dispensers Successful propane dispenser installations are.
Overview of Montana’s Stormwater Regulatory Program.
Student Book © 2004 Propane Education & Research CouncilPage Reducing Cargo Tank Vapor Pressure Using a Plant Compressor In order to use.
MassDEP Underground Storage Tank Program Program Requirements for Owners and Operators Winter 2015 Workshops 1.
Backflow Prevention for Fire Sprinkler Systems State of Illinois Plumbing Code.
PROSSER PUMP Long Beach Fire Department. BASIC SET- UP Components Main dewatering pump Junction box Attached power cord Additional extention cord.
A/C SYSTEM SERVICE 1  A/C manifold gauge set  Manifold valves  Hose end valves  Performance test  Pressure diagnosis  Manifold purging and disconnect.
PRODUCT LINE LEAK DETECTION (including a summary of the 2015 UST regulations) Katie Seaborn AMERICAN CONTAINMENT SERVICES, INC. ® Annual GTEC Underground.
West Memphis Terminal Procedures EQU-604-WM Oil Water Separator Alarms Influent to Lift Station #40 08/30/2007 2/25/20161 Oil Water Separator – Influent.
 The Illinois Environmental Protection Act is silent with regard to storm water.  Illinois EPA’s authority to deal with storm water derives from delegated.
Types of Fire Apparatus Equipped with a Fire Pump Sugar Land Fire Department Driver/Operator—Pumper Academy Spring 2003.
ME444 ENGINEERING PIPING SYSTEM DESIGN
Permit Process & Application Guide
Presented by John Lewandowski and Mike Larabel Inspection, Testing, and Maintenance of Kitchen Hood Systems Michigan Fire Inspectors Society Winter Educational.
ELA Forum The basis, objective and content of SNEL - EN81-80 The basis, objective and content of SNEL - EN81-80 Michael Savage.
Steve Griffith February 28th, 2017
Domestic Hot Water Recirculation Design
Workshop developed by RCAP/AWWA and funded by the USEPA
Fire Alarm Systems for Emergency Operations of Elevators
ARCHITECTURAL SAFETY FEATURES –Exit Separations –Continuation of Exit Stairs from lower to upper floors –Discharge from Exits FIRE PROTECTION FEATURES.
Flammable and Combustible Liquids
Private Septic Systems
Emergency Electrical Power Supply for Buildings
Pumps and Lift Stations
Private Septic Systems
Firefighting equipment
State Electrical Division North Carolina Department of Insurance
North Carolina Department of Insurance Office of State Fire Marshal
FIRE ALARM DRILL 26 © Ted Smith 2017.
Throw Me a Life Preserver, We Are Drowning in Leachate
Denver Fire Depart. License Fire Alarm Practice Test # 12
North Carolina Department of Insurance Office of State Fire Marshal
INTRODUCTION ALAQUA is a US corporation. We manufacture process equipment. Our engineers have over 20 years experience in the engineering of sanitary and.
Presentation transcript:

INDUSTRIAL SYSTEMS, INC. ELEVATOR CODE LUNCH AND LEARN

EFFECTIVE 9-1-2008 TDLR ADOPTED THE CODE PUBLISHED BY THE AMERICAN SOCIETY OF MECHANICAL ENGINEERS (ASME) REGARDING DRAINAGE OF ELEVATOR SUMPS CONSTRUCTION FOR WHICH A CONTRACT IS EXECUTED AFTER 9-1-08, THE HOSE BIBB , MANUAL SWITCH AND DRUM APPROACH WILL NO LONGER BE PERMITTED.

SUMP PUMPS AND DRAINS SHALL AUTOMATICALLY REMOVE FLUID FROM ALL ELEVATOR PITS WITHOUT ANY HUMAN INTERVENTION! THE LOCALITIES AND THE TEXAS COMMISSION OF EVIRONMENTAL QUALITY (TCEQ) SHALL REGULATE WHAT CAN BE DONE WITH THE DISCHARGED FLUID AFTER IT IS AUTOMATICALLY REMOVED FROM THE ELEVATOR PIT

ASME A 17.1 SECTION 2.2.2.5 (DESIGN AND CONSTRUCTION OF ELEVATOR PITS) 2.2.2.5 “ IN ELEVATORS PROVIDED WITH FIREFIGHTERS EMERGENCY OPERATION, A DRAIN OR SUMP PUMP SHALL BE PROVIDED AS WELL. THE SUMP PUMP OR DRAIN SHALL HAVE THE CAPACITY TO REMOVE A MINIMUM OF 11.4 CU. METERS PER HOUR (3,000 GALLONS PER HOUR).”

WHY? THE INTENT AND TDLR’S INTERPRETATION OF THE RULE IS FOR WATER AND WATER/ WITH ANY OTHER SUBSTANCE TO BE REMOVED AUTOMATICALLY SO AN ELEVATOR CAN CONTINUE TO BE AVAILIBLE FOR USE IN AN EMERGENCY SUCH AS A FIRE.

THE FOLLOWING COMPONENTS “ARE PROHIBITED” LOCAL ELEVATOR SUMP PUMP MANUAL SWITCHING. MANUAL DRUM AND BARREL SWITCHING SUMP PUMP DISCHARGE/TERMINATION TO A HOSE BIB.

THE FOLLOWING IS AN ACCEPTED PRACTICE THE DRAIN FROM THIS SUMP PUMP WILL BE ALLOWED TO TERMINATE WATER INTO THE SEWER SYSTEM. ALL OF THE ALARMS FOR NOTICATION AND PROPER AUTOMATIC FUNCITON OF THE PUMP SYSTEM SHALL BE INSTALLED.

COMMON QUESTIONS DOES THE CODE REQUIRE THAT MULTIPLE ELEVATORS IN A SINGLE HOISTWAY HAVE A SUMP PUMP FOR EACH ELEVATOR? ARE ALL SUMP PUMPS AND AUTOMATIC CONTROLS CREATED EQUAL?

WHAT SHOULD MY PIT SIZE BE? The recommended 50 GPM Sump Pit size is 24”x24”x24” WHAT DOSE COSA SAY ABOUT DIRECT DISCHARGE INTO THE SEWER? WHAT DOSE COSA SAY ABOUT A WATER/OIL SEPARATOR?

NEC QUESTION TO TDLR The NEC CODE, 2008 SECT. 620.21 PARAGRAPH #4-E P.959 states that a sump pump or oil recovery pump located in the pit shall be permitted to be cord connected, hard usage oil resistant type of a length not to exceed 6FT. Will TDLR enforce the 6FT. rule in the low lying TEXAS Coastal Regions?

ANSWERE FROM TDLR (TDLR will enforce the 6FT. rule STATE WIDE.) -LAWRENCE TAYLOR--8-19-2009

QUESTION TO TDLR Can the sump pump control panel be installed in the elevator machine room?

ANSWERE FROM TDLR (YES, the sump pump control panel may be installed in the elevator Machine room.) -LAWRENCE TAYLOR----8-19-2009

QUESTION TO TDLR MR. LAWRENCE TAYLOR, HELLO HOW ARE Y'ALL DOING IN AUSTIN TODAY? I HAD ANOTHER QUESTION FOR YOU SIR. CAN AN ELECTRIC VALVE OR ANY VALVE BE INSTALLED IN THE HOISTWAY PIPING?

ANSWARE FROM TDLR (As long as the valve will not shut off the pump then yes it is allowed to be in the hoist way.) -Lawrence Taylor

WHAT IS THE RECOMMENDED SUMP PUMP? THE STANCOR OIL-MINDER TEXAS VERSION SUBMERSIBLE PUMP AND CONTROL SYSTEM MEETS AND EXCEEDS THE NEW RULES THAT HAVE BEEN ADAPTED BY (TDLR) THE STANCOR SE-50-TV-RP WILL AUTOMATICALLY DISCHARGE WATER FROM ELEVATOR SUMP PITS, TRANSFORMER VAULTS, AND OTHER TYPES OF SUMPS WITH OUT DANGER OF EJECTING OIL OUT OF THE SUMP AND INTO A SEWER SYSTEM.

REMINDERS IF YOU THINK YOU FALL UNDER THE GRANDFATHER CLAUSE THEN YOU BETTER BE PREPARED. THE ELEVATOR INSPECTORS WILL BE LOOKING FOR CERTIFICATION OF THE FOLLOWING : PUMP CAPACITY, COMPLIANCE WITH NEC IE:WATER AND OIL RESISTANT CORDS NO LONGER THEN 6 FEET.

THANK YOU FOR YOUR TIME ! ANY FURTHER QUESTIONS MAY BE DIRECTED TO: INDUSTRIAL SYSTEMS,INC. RICHARD POWELL OR CHRIS LONG 210-493-4200