September 29-30, 2011 Drinking Water Program Sustained Compliance Workshop Lee Johnson, P.E. 907-451-2179.

Slides:



Advertisements
Similar presentations
Inspect Water Distribution EO Air Gaps, Vacuum Breaker, and Back Flow Preventers TP 8 50 min.
Advertisements

Inspect Water Distribution EO Inspect Ship Water Supply Ship Plumbing Characteristics TP 15.
1 NBL Plumbing Cross Connections and Backflow Prevention Program NBL Plumbing System Inspection December 2009.
Professional Food Manager Certification Version © NSF International, 2007 Professional Food Manager Certification Version © NSF International,
Let’s watch a DVD… DVD Instructor Notes
City of Milwaukee Cross Connection Program Construction Trades Division Cross Connection Section.
Cross-Connections Gary Carlson Drinking Water Program U.S. EPA Region 8.
DENVER ZOO Lion’s Quarters Recycle Cross-connection
PB - Dialysis Review1 DIALYSIS MACHINES REVIEW OF PLUMBING INSTALLATION REQUIREMENTS.
Backflow Preventers. Cross Connection Direct arrangement of piping which allows the potable water supply to be connected to a line which contains a contamination.
2012 Plumbing Codes International Plumbing Code Uniform Plumbing Code David McCarthy, P.E. City of Phoenix.
Proposed Effective Date: January 1, 2009 Based on Plan Received Date OR Based on Installation Date Wisconsin Uniform Plumbing Code.
UL/FM Fire Pump Systems Lunch & Learn 04/18/05
Plumbing System Albert Einstein was named an honorary member of the Plumbers and Steamfitters Union after publicly stating that he would become a plumber.
Chapter 20 Plumbing Plans.
Equipment and Facilities. 154 Plan Review The local health department must assess your facility and equipment before: –Beginning construction of a food.
Potential Pathways for Coliform Contamination. Fixing Positive Coliform Results.
Chemigation. Chemigation Chemigation is the process of applying pesticides and fertilizer through irrigation waterChemigation is the process of applying.
Connecticut Department of Energy and Environmental Protection.
Backflow Training Introduction to Backflow For Irrigation Systems.
MassDEP, Environmental Analyst
Frost Free Water Hydrants
State of Ohio Class A Drinking Water Operator Certification Program This course includes content developed by the Ohio Environmental Protection Agency,
Direct Cross-Connection (a) A Clean-In-Place system is used to direct sanitizer from a reservoir to a recently cleaned milk tank. The sanitizer exists.
Michael D. Dukes, Ph.D., P.E. Agricultural & Biological Engineering Institute of Food and Agricultural Sciences (IFAS)‏ Landscape Fundamentals IST Wimauma,
AL/MS AWWA Effective Backflow Prevention August 26, 2013 Sam McElroy, PE Civil Services, LLC (256)
Backflow Prevention.
Hydronic Mechanical Controls
Safe Facilities and Equipment
1-1. Key Sanitation condition No. 1:  Safe supply for water that contacts food and food contact surfaces;  Safe water supply for production of ice; and.
Implementing Rain Water Harvesting into Building Construction in VA Presented by: Guy Tomberlin, CBO Code Specialist III Fairfax County DPWES, Land Development.
After the Sanitary Survey
NS205 Food Safety and Microbiology Unit 6 Foodservice Utility and Building Systems.
M.K. PANDEY/P. Jenssen Centralised –Decentralised transportation system.
© 2009 Michigan State University licensed under CC-BY-SA, original at Water Quality.
Residential Construction Unit 5 Energy Efficiencies and Mechanicals Mr. Todzia.
Trade of Plumbing – Phase 2 Module 2 – Unit 9 Module 2: Domestic Hot and Cold Water Services Unit 9 – Valves and Taps Duration – 11 Hours.
1 CTC 450 Review Water Processes. 2 Objectives Understand the basics with respect to operation of waterworks.
Drinking Water + Compressed Air = Dangerous Mixture Spokane Regional Cross Connection Control Chapter Requirements for Winterizing Irrigation Systems with.
Specification & Installation pitfalls “Getting it right to ensure safe drinking water”
All About Sanitary Surveys David Edmunds Environmental Program Specialist ADEC Drinking Water Program Sustained Compliance: What It Means to Public Water.
Materials used for walls, floors, and ceilings Arrangement of equipment and fixtures Layout of utilities Management of waste When designing or.
Backflow Prevention for Fire Sprinkler Systems State of Illinois Plumbing Code.
THE IMPORTANCE OF SANITARY SURVEYS by Mary L. Howell, Backflow Management Inc.
Backflow Installation Public Meeting October 20, 2010.
C5305 – WASTE WATER AND WATER SUPPLY ENGINEERING
Presented by: City of St. Cloud. Water and Sewer Charges Base Fees: Service Availability—Fixed Fee Consumption Fees: Actual Usage—Variable Fee Other Fixed.
Administration Code Changes to Incorporate Graywater Policy Principles Jayne Joy, P.E. Director, Environmental & Regulatory Compliance January 2016 EASTERN.
Floors, walls, and ceilings: Materials must be smooth and durable for easier cleaning Must be regularly maintained 9-3 Interior Requirements for a Safe.
Backflow prevention Why the changes? Greater emphasis on protection of the water supply FDA also focuses heavily on product protection In some places it.
Cross-Connection Control (CCC) Program Overview. Did you know? Contamination from cross connections and backsiphonage were found to cause the majority.
“Beyond the loop layout”.  Jeremy Neven, C.B.C.O. ◦ Chief Building Official ◦ Plumber ◦ HVAC Designer ◦
CROSS CONNECTION CONTROL PROGRAM
Water System Infrastructure
Backflow Prevention.
Plumbing system fundamental and design course
Workshop developed by RCAP/AWWA and funded by the USEPA
Cross Connection Survey Training
Backflow Prevention and Cross Connection Control Update
Let’s watch a DVD… DVD Instructor Notes
Your Public Water System’s Cross-Connection Control Program
By: Pennsylvania Water Specialties Company (PAWSC)
CTC 450 Review Water Processes.
Cross-Connection Control and Backflow Prevention
Frost Free Water Hydrants
Let’s watch a DVD… DVD Instructor Notes
2 Days National Workshop on “National Building Code of India 2016 ”
Let’s watch a DVD… DVD Instructor Notes
Backflow Devices 5 Types.
Presentation transcript:

September 29-30, 2011 Drinking Water Program Sustained Compliance Workshop Lee Johnson, P.E

Objectives What is a Cross Connection? How are they regulated? What is a Back Flow Preventer? Types of Preventers Examples of Cross Connections

What is a Cross Connection? Defined in 18 AAC (a)(36) Basically it is an ACTUAL or POTENTIAL physical connection or arrangement between otherwise separate piping systems containing potable water and any contaminant, whereby water may flow between the two systems.

Back Pressure: Pressure of nonpotable fluid is greater than pressure of potable water. Back Siphonage: Negative pressure in potable water piping causes nonpotable fluid to be siphoned into potable water line.

High or Low Hazard Low Hazard - will not have an immediate effect on health, but could have an impact on the potable water. High Hazard - will cause an immediate toxic effect or cause immediate and severe illness.

Cross Connections Are Prohibited 18 AAC (a) A person may not construct, install, or use a cross connection in a public water system, or allow a water system that contains a cross- connection to connect to a public water system.

18 AAC (b) If the department determines that a facility has the potential to contaminate public water system through backflow, the owner or operator of the public water system shall install, maintain, and test on the service line to and at other locations in that facility, a backflow prevention device that conforms to ANSI/AWWA Standards C510-97, Double Check Valve Backflow prevention Assembly, or C511-97, Reduced-Pressure Principle Backflow Prevention Assembly, adopted by reference in 18 AAC (b).

The owner or operator of the public water system may delegate the installation, maintenance, and testing of the backflow prevention device to the owner or operator of the facility that poses the risk. This delegation does not relieve the owner or operator of the public water system of the responsibility to install, maintain, and test the backflow prevention device.

Statutes & Codes Alaska Statutes: Article 8 Section Portions of Uniform Plumbing Code – 2009 adopted by reference, 18 AAC (c) UPC Chapter 6 Section 603 pertains to Cross Connections Table 6-2 Backflow Prevention Devices, Assemblies, and Methods

Service Connections and Premise Plumbing Drinking water program regulates water systems – Sources, treatment, and distribution systems, not service connections. There is risk within a building from cross connections even if distribution system is protected. Plumbing Code What about cross connections within your facility? Need to protect potable taps from nonpotable use taps within water plant.

Plan Review & Sanitary Survey During engineering plan reviews we look for Cross Connections within the public water system, the treatment plant, and the water distribution system. BUT…….. For existing systems the sanitary survey process is the only other opportunity for staff or inspectors to look for and ask questions about facilities connected to the distribution system? Also – Systems and plants are often modified through routine maintenance resulting in new cross connections or elimination of backflow prevention.

Owners, Operators, and Surveyors Should Consider: Types of facilities connected to drinking water distribution system (Actual or Potential Hazards?): Health Clinics Hospitals Schools Water and Wastewater Treatment plants Mortuaries Other

Others? What other potential or actual cross connections can you name?

Direct vs Indirect

Devices and Assemblies Device -- cannot be tested Assembly -- has two isolation valves and has test cocks for proper testing of the backflow prevention assembly

Backflow Prevention Air Gap 2 Pipe Diameters or 1 inch minimum RPZ Reduced Pressure Zone Assembly DC Double Check Valve Assembly PVB Pressure Vacuum Breaker AVB Atmospheric Vacuum Breaker

Backflow Prevention Prevents Backsiphonage LOW & HIGH HAZARD Proper Air Gap Atmospheric Vacuum Breaker Pressure Vacuum Breaker Reduced Pressure Zone BFP Double Check Valve (low hazard only) Prevents Backpressure LOW HAZARD Proper Air Gap Double Check Valve HIGH HAZARD Proper Air Gap Reduced Pressure Zone BFP

Insert New table 6-2

Air Gap Flow condition Non flow condition Atmospheric Vacuum Breaker Protection

EXAMPLE AIR GAPS

Tank Air Gap POTABLE SUPPLY PUMP FLOAT NONPOTABLE APPLICATION

Hose Bibb Vacuum Breaker

Pressure Vacuum Breaker TEST PORTS NORMAL FLOW

Double Check Valve

FLOW DIRECTION #1 GATE VALVE #2 CHECK VALVE Reduced Pressure Zone Backflow Prevention Assembly (RPZ) TEST PORTS PRESSURE DIFFERENTIAL RELIEF VALVE #2 CHECK VALVE #1 CHECK VALVE #2 GATE VALVE High hazard condition

RPZ

RPZ – Proper Installation?

RPZ

Proper Installation?

Pumping Station Cross-connections Priming of raw water pumps with finished water. Air relief valves piped directly to a drain. Cooling water for an emergency generator submerged in a drain or returned to the potable supply. GATE VALVE FLOOR DRAIN AIR VACUUM RELEASE SILENT CHECK

Treatment Bypass Piping

Emergency Bypass

Emergency Bypass Installed

Filter Bypass Piping Bypass Piping

Disinfection Bypass Piping

Water Meter as Cross Connection?

Submerged Inlet

Surface Wash Arms

Surface Wash Arm – Pressure Filter

Backwash Waste Lines

Softener Backwash Waste Line

Air Gap

UV and Cross Connections?

Treatment Plant Lab Sink

Distribution System Direct connections to sewers for flushing either the water main or sewer.

Distribution Issues

Alaska Drinking Water Regulations 18AAC American Water Works Association Recommended Practice for Backflow Prevention and Cross Connection Control – M14 EPA’s Cross Connection Control Manual Uniform Plumbing Code Chapter 6 Kenneth Kerry Water Distribution System O&M Manual USC Foundation for Cross-Connection Control and Hydraulic Research Lots of internet resources