Ethernet Service OAM/PM November 2011 Seth Higgins, Global Ethernet Applications.

Slides:



Advertisements
Similar presentations
MEF 30.1 Service OAM Fault Management Implementation Agreement
Advertisements

1 Metro Ethernet Forum OAM An Update Matt Squire Hatteras Networks.
Ethernet OAM Update Overview & Technical Aspects Dinesh Mohan May 18, 2004.
1 Introducing the Specifications of the Metro Ethernet Forum.
1 Introducing the Specifications of the Metro Ethernet Forum.
1 Introducing the Specifications of the Metro Ethernet Forum.
1 Introducing the Specifications of the Metro Ethernet Forum.
1 Introducing the Specifications of the Metro Ethernet Forum.
1 Introducing the Specifications of the Metro Ethernet Forum MEF 17 Service OAM Framework and Requirements February 2008.
Introducing the Specifications of the Metro Ethernet Forum
MEF 30 Service OAM Fault Management Implementation Agreement
Innovative and Unique Solution for EOE – RAISECOM
Delivering Ethernet Services to the Research & Education Community.
Ethernet Access Services Definition and Implementation
1 MEF Reference Presentation November 2011 Carrier Ethernet Service OAM.
Ralph Santitoro Carrier Ethernet Market Development December 2, 2010 Panel II: Ramping Up Ethernet Connection-Oriented Ethernet.
IEEE 802.1ag Ethernet OAM Ronald van der Pol SARA Architecture Workshop, 1-2 Dec, Amsterdam.
802.1ag - Connectivity Fault Management Tutorial – Part 1 Dinesh Mohan July 12, 2004.
Broadband Network Management:
CCNA2 Module 4. Discovering and Connecting to Neighbors Enable and disable CDP Use the show cdp neighbors command Determine which neighboring devices.
1 Semester 2 Module 4 Learning about Other Devices Yuda college of business James Chen
Foundry Networks – All rights reserved. 1 Protection and Fault Recovery at Internet Peering Points using 802.1ag CFM Rahul Vir Product Marketing Manager.
Multi-Layer Switching Layers 1, 2, and 3. Cisco Hierarchical Model Access Layer –Workgroup –Access layer aggregation and L3/L4 services Distribution Layer.
1 Version 3 Module 8 Ethernet Switching. 2 Version 3 Ethernet Switching Ethernet is a shared media –One node can transmit data at a time More nodes increases.
1 CCNA 2 v3.1 Module 9. 2 Basic Router Troubleshooting CCNA 2, Module 9.
1 CCNA 2 v3.1 Module 4. 2 CCNA 2 Module 4 Learning about Devices.
Ralph Santitoro Carrier Ethernet Market Development Packet Optical Networking for LTE Cell Tower Backhaul.
Introduction. 2 What Is SmartFlow? SmartFlow is the first application to test QoS and analyze the performance and behavior of the new breed of policy-based.
Ethernet Frame PreambleDestination Address Source Address Length/ Type LLC/ Data Frame Check Sequence.
Cell Backhaul: Realities of Ethernet in SLA Environments
Ethernet Demarcation Devices
1 MEF 35: Service OAM Performance Monitoring Implementation Agreement July 2012 Introducing the Specifications of the MEF.
International department Raisecom Technology Co., Ltd 12/2007 RAISECOM RC551-GE Ethernet Demarcation Device.
Ralph Santitoro March 25, 2010 Delivering Next-Generation Services How Packet Optical Networking and Connection-Oriented Ethernet Are Changing Metro Networks.
Connecting LANs, Backbone Networks, and Virtual LANs
1 Introducing the Specifications of the Metro Ethernet Forum.
Enabling Broadband On-Demand Services Ethernet Services.
1xE1/T1 over Ethernet Multiplexer (TDMoIP) Slide 1Updated: April 2010Orion Telecom Networks Inc xE1/T1 over Ethernet Multiplexer (TDMoIP) Product.
1 MEF 35: Service OAM Performance Monitoring Implementation Agreement (includes MEF ) December 2013 Introducing the Specifications of the MEF.
1 MEF 35.0.x: Service OAM Performance Monitoring Implementation Agreement December 2013 Introducing the Specifications of the MEF.
Document Number ETH West Diamond Avenue - Third Floor, Gaithersburg, MD Phone: (301) Fax: (301)
Discussion Items for Inter-Provider Service Performance Metrics Ralph Santitoro CTO Office Inter-Provider QoS Workshop at MIT.
Nortel Confidential Information 1 Provider Backbone Transport Alan Beard Dir Business Development 19 th November 2007.
Common Devices Used In Computer Networks
Brierley 1 Module 4 Module 4 Introduction to LAN Switching.
POSTECH DP&NM Lab. Internet Traffic Monitoring and Analysis: Methods and Applications (1) 4. Active Monitoring Techniques.
Module 8: Ethernet Switching
Lecturer: Tamanna Haque Nipa
Metro Ethernet UNI Standards Update Gary Southwell VP of Product Marketing Internet Photonics MEF Marketing Collateral co-chair
Carrier Ethernet Last Update Copyright Kenneth M. Chipps Ph.D. 1.
Cisco 3 - Switching Perrine. J Page 16/4/2016 Chapter 4 Switches The performance of shared-medium Ethernet is affected by several factors: data frame broadcast.
Carrier-Grade Ethernet Technology
Service Level Monitoring. Measuring Network Delay, Jitter, and Packet-loss  Multi-media applications are sensitive to transmission characteristics of.
PART1: IP SLA Voice Performance Measurement and related technologies 1.
CSE5803 Advanced Internet Protocols and Applications (14) Introduction Developed in recent years, for low cost phone calls (long distance in particular).
Faster and Cheaper - EH-1200L.v700 High Capacity, Low Cost E-band Radio.
Computer Network Architecture Lecture 3: Network Connectivity Devices.
CCNA3 Module 4 Brierley Module 4. CCNA3 Module 4 Brierley Topics LAN congestion and its effect on network performance Advantages of LAN segmentation in.
Company LOGO Network Management Architecture By Dr. Shadi Masadeh 1.
Text TCS Internal October 17, 2014 Introduction to Ethernet OAM.
Increase Profitability with Carrier-grade Ethernet Access Presented by: Yacov Cazes Director Product Management & BD Customers’ Event Crete, May 2007.
MEF Protection Work Pascal Menezes Technical Contributor June 3 rd 2003.
Automated provisioning of Ethernet OAM in CarrierEthernet networks: the case of GRNET Leonidas Poulopoulos Michalis Mamalis Stauros.
Anthony Magee, 6 th September 2013 Carrier Ethernet Service Life-Cycle Management.
Ethernet 802.1ag Fault Management Across Domains Freek Dijkstra, Sander Boele, Ronald van der Pol – SARA TERENA Networking Conference – Reykjavík, 23 May.
Early Adopter of NFV? Mitigate Risk! UKNOF 34 - Manchester Anthony Magee, 21 st April 2016 Global Business Development.
Technology Brief Ethernet OAM
Ethernet OAM Survey and Introducing Network Management Service
Ethernet OAM Survey and Introducing Network Management Service
Tal Mizrahi Marvell IETF Meeting 78, July 2010
Presentation transcript:

Ethernet Service OAM/PM November 2011 Seth Higgins, Global Ethernet Applications

© 2011 ADVA Optical Networking. All rights reserved. Confidential. 22 Carrier Ethernet Service Delivery To replace SONET/SDH or Frame Relay with Ethernet, the edge network must replicate… Connectivity Resiliency PM statistics SLA reporting Legacy transport and service interoperability Timing Balance: IP Core with L2 access and transport IP is good for connectivity, resiliency and interop Routers are bad for true accurate stats and timing Monitoring a hybrid network relies heavily on the endpoints Standards allow added information from core But services are end-to-end, and so must be the monitoring

© 2011 ADVA Optical Networking. All rights reserved. Confidential. 33 What are people buying now? SLA’s with lowest price per performance Tools to operate and troubleshoot Ethernet like SONET Timing distribution: mobile backhaul and algorithmic trading E-Line to E-LAN transition Next step in SONET to Ethernet evolution

© 2011 ADVA Optical Networking. All rights reserved. Confidential. 44 Operating an Ethernet Service Turn-up and test Low-touch provisioning + CLI / GUI / SNMP configuration Validate installation with RFC-2544 test and export acceptance report Performance Monitoring Service Assurance stats, e.g. loss, latency and jitter Threshold crossing alarms for all PM attributes Troubleshooting without truck rolls Loopback and throughput/latency test suite Dying Gasp alert and cable integrity check EMS/NMS/OSS integration Inventory, alarming, monthly SLA reports… Ethernet/IP WAN Business customer LAN Service demarcation Primary Objectives Reduce truck rolls Accurate and scalable PM

© 2011 ADVA Optical Networking. All rights reserved. Confidential. 55 Mobile Backhaul Killer application for Service Assurance Mobile Operators are transitioning from TDM to TDM-like Ethernet Strict SLA for delay (4ms), jitter (1ms) and loss (0.01%) I-temp, +24VDC, 1RU, Sync distribution 100’s of towers per metro, 1000’s per region OAM/PM must scale at MSC hub Mobile operator must deal consistently with hundreds of access providers Mobile Operator Access Provider Mobile Operator Cell site gateway NTE Aggregation MSC gateway Ethernet Transport UNIE-NNI OAM reflector

© 2011 ADVA Optical Networking. All rights reserved. Confidential. 66 Delay Measurement Service Assurance includes frame loss, delay and jitter Delay measured either roundtrip or one-way (bidirectional) Loss may be a synthetic representation or actual frame counts (p2p) Synthetic frames measure delay Send at negligible and configurable rate Timestamp at both ends for one-way values Customize packet size and classification Collect and report conformance data Alarm on violations ProbeReflector data Message

© 2011 ADVA Optical Networking. All rights reserved. Confidential. 77 Measuring One-Way Delay Delay from hops (inherit delay) and network congestion Time of Day Synchronization between end-points required e.g. NTP, GPS and 1588v2 Endpoints should reference the same Time of Day source Synchronization errors occur when there is a negative time different between the TX and RX Different Time of Day sources Poor quality TOD source (precision and stratum level) or DCN congestion Inaccurate time client algorithm Delay between timestamp and packet send/receive causes inaccuracy Must timestamp at the moment of send/receive Without hardware-based timestamping software interrupts cause problems CO or MSC Customer Premise, Hub or Cell Tower Service Assurance NTP

© 2011 ADVA Optical Networking. All rights reserved. Confidential. 88 Ethernet OAM Areas of standards activities UNI Media Converter Carrier Edge Media Converter IEEE 802.3ah EFM MEF & ITU Y.1731 IEEE 802.1Qay Access Link OAM MEF & ITU Y.1731 IEEE 802.1ag Connectivity Layer OAM Service Layer OAM (UNI to UNI) 100FX Customer Euqipment Customer Equipment Carrier NW MEF NID 802.1ag CFM – Connectivity Fault Management Y.1731 OAM (Operations, Administration and Maintenance) – Service Assurance 802.3ah EFM (Ethernet in the First Mile) – Dying Gasp

© 2011 ADVA Optical Networking. All rights reserved. Confidential. 99 Customer Domain Service Provider Domain Operator Domain Operator A Provider BridgesOperator B Provider Bridges CPE MD Level=7 MD Level=3 MD Level=2 Operator Domain MEPMIPMIPMA IEEE 802.1ag – OAM Maintenance Entities Up MEP – CFM traffic is sent towards the bridge (e.g. from LAN towards WAN through the device) Down MEP – CFM traffic is sent away from the bridge (e.g. from WAN towards the network)

© 2011 ADVA Optical Networking. All rights reserved. Confidential. 10 Periodic multicast message toward other MEPs in the same MA Provides heartbeat for connectivity check Also used for MEP MAC discovery Y.1731 and CFM defined the same function which causes interoperability issues CCM Interval 3.3 msec 10 msec 100 msec 1 sec 10 sec 1 min 10 min ETH-CCM - Continuity Check Messages B A D Provider Domain Operator BOperator A MEPMIPMIP C

© 2011 ADVA Optical Networking. All rights reserved. Confidential. 11 LBM/LBR -Loopback Messages  Loopback Messages (LBM) are unicast messages used for fault isolation (similar to ping)  LBMs are used to verify the connectivity between two maintenance points - i.e. between two MEPs or between a MEP and MIP  At the destination, a Loopback Reply (LBR) is sent back to the sender MEPMIPMIPLBMLRM Provider Domain Operator BOperator A A C B D

© 2011 ADVA Optical Networking. All rights reserved. Confidential. 12 LTM/LTR - Link Trace Message  Link Trace Messages (LTM) are used for path discovery  Sent from the source MEP to the target MEP (or MIP)  At each MIP to the target, a Link Trace Response (LTR) message is sent back to the originating MEP  Based on the information in the LTRs received, the originating MEP can determine the path to the target MEP Provider Domain MEPMIPMIPLTMLTR D Operator BOperator A A C B

© 2011 ADVA Optical Networking. All rights reserved. Confidential. 13 Link-Loss Forwarding Service application of ETH-CC/RDI or AIS Link activity is local and abstracted by a network in the middle, yet endpoints assume link status represents connectivity Failure anywhere along an EVC propagates to remote site(s) Continuity Check Messages with Remote Defect Indication or Alarm Indication Signal Link change triggers customer protection scheme to respond quickly Customer Premise Access Metro Core Metro 3 rd party network Link Fault(s) Disable Port(s)

© 2011 ADVA Optical Networking. All rights reserved. Confidential. 14 Probe (generator) Customer Premise Builds on 802.1ag functionality and adds: Performance monitoring Delay Measurement (DM), Loss Measurement (LM) Under Study: Synthetic Loss Measurement (SLM) Additional Fault Management: AIS & RDI Test pattern and test mode (TST) But no test methodology or standard test suite Automatic Protection Switching (APS) Other not so-common functions: MCC, VSM/EXM, 1DM. Y.1731 Defines its own hierarchical structure and Terminology MEG – Maintenance Entity Group (Similar to MD + MA) MEPs and MIPs keep CFM Definitions 14 IP Network Reflector Customer Premise Reflector Unaffected Customer Traffic Unaffected Customer Traffic ITU Y.1731 – Service Assurance OAM

© 2011 ADVA Optical Networking. All rights reserved. Confidential. 15 Ethernet Loss Measurement ETH-LM: Loss Measurement of customer data frames Single-ended, on-demand, using ETH-LMM/ETH-LMR Frame Loss measurements are calculated per Y.1731… Frame Loss (far-end) = |TxFCf[tc] – TxFCf[tp]| - |RxFCf[tc] – RxFCf[tp]| Frame Loss (near-end) = |TxFCb[tc] – TxFCb[tp]| - |RxFCl[tc] – RxFCl[tp]| ETH-SLM: Synthetic Loss Measurement New OAM function defines a way to measure Frame Loss Ratio Multipoint support, in addition to Point-to-Point connectivity Use sequence numbers for ETH-SLM/SLR synthetic frames Count transmitted and received synthetic frames between MEPs

© 2011 ADVA Optical Networking. All rights reserved. Confidential. 16 Threshold Crossing Alarms Traps sent on any violation Thresholds must be user configurable Could trigger alert

© 2011 ADVA Optical Networking. All rights reserved. Confidential. 17 Dying Gasp alert Signals alert on power failure IEEE 802.3ah EFM “Dying Gasp” message or SNMP trap 10/100/1000BT Network Dying Gasp Customer Equipment

© 2011 ADVA Optical Networking. All rights reserved. Confidential. 18 CO or MSC Customer Premise or Cell Tower Test Head Test and turn-up Test to a loopback Traffic Generator Turn-up & troubleshooting RFC-2544 throughput test VLAN or port loopbacks Terminal or facility direction SA/DA swap for L2 transport

© 2011 ADVA Optical Networking. All rights reserved. Confidential. 19 RFC-2544 Testing Suite of tests for verifying Ethernet equipment Also used for Ethernet services Suite of tests defined: Throughput Latency Frame loss Back to back System Recovery Reset Results generally presented in graphical form Each test is performed multiple times with different frame sizes (64, 128, 256,…) MEF SLA parameters Benchmarking Methodology for Network Interconnect Devices

© 2011 ADVA Optical Networking. All rights reserved. Confidential. 20 Y.1564 Service Configuration Test Verify throughput performance for each service at CIR, CIR+EIR and above Tests up to CIR to verify committed SLA parameters Then increase the traffic rate into the red zone to verify policing Performance is uncertain in the yellow zone and needn’t be checked Optional CBS/EBS configuration verification All SLA performance parameters measured at the same time Frame Delay, Frame Delay Variation and Frame Loss

© 2011 ADVA Optical Networking. All rights reserved. Confidential. 21 Y.1564 Service Performance Test Simultaneously validate SLA conformance for all defined services Generate traffic at CIR for all flows and report performance Test for 15 minutes to 24 hours

© 2011 ADVA Optical Networking. All rights reserved. Confidential. 22 Timing distribution and sync verification Cell Site UNI Mobile Network Operator Access and Backhaul Network Trusted Wireline Operator Backhaul Network Meets SLA? Mobile Network Operator Mobile Core SLA/Stability Trusted Wireline Operator provides Synchronization Service Mobile Operator is customer of the Synchronization Service Both need tools for synchronization service Prove accuracy at time of network deployment Monitor stability in normal operation When things go wrong, diagnostics are required

© 2011 ADVA Optical Networking. All rights reserved. Confidential. 23 IP/MPLS Network Ubiquitous Ethernet Service End-to-end service assurance - Consistent delivery platform - Any access PDH SDH/SONET Evolve your embedded base to support contemporary requirements for Mobile Backhaul, Business Ethernet, and Wholesale NNI services Ethernet Access

Thank you IMPORTANT NOTICE The content of this presentation is strictly confidential. ADVA Optical Networking is the exclusive owner or licensee of the content, material, and information in this presentation. Any reproduction, publication or reprint, in whole or in part, is strictly prohibited. The information in this presentation may not be accurate, complete or up to date, and is provided without warranties or representations of any kind, either express or implied. ADVA Optical Networking shall not be responsible for and disclaims any liability for any loss or damages, including without limitation, direct, indirect, incidental, consequential and special damages, alleged to have been caused by or in connection with using and/or relying on the information contained in this presentation. Copyright © for the entire content of this presentation: ADVA Optical Networking.