The Taiwan group Institute of Phys, Academia Sinica: Wen-Chen Chang, Yen-Chu Chen, Da-Shung Su Ling-Tung U: Ting-Hua Chang Committed responsibility: Build.

Slides:



Advertisements
Similar presentations
Controller Tests Stephen Kaye Controller Test Motivation Testing the controller before the next generation helps to shake out any remaining.
Advertisements

The group is developing readout electronics for initial use with the prototype test-stand at Fermilab. This work will contribute towards the design and.
JLab High Resolution TDC Hall D Electronics Review (7/03) - Ed Jastrzembski.
TileCal Electronics A Status Report J. Pilcher 17-Sept-1998.
RPC Electronics Status Overall system TDC –Digitizing frequency issue (determine the bin size of the TDC value) Discriminator test result Trigger module.
July 10, 2008 PHENIX RPC review C.Y. Chi 1 RPC Front End Electronics On chamber discriminator  The strips  The CMS discriminator chips  The discriminator.
Sept 25, 2008 PHENIX RPC review C.Y. Chi 1 RPC Front End Electronics On chamber discriminator  The strips  The CMS discriminator chips  The discriminator.
6 June 2002UK/HCAL common issues1 Paul Dauncey Imperial College Outline: UK commitments Trigger issues DAQ issues Readout electronics issues Many more.
Ionization Profile Monitor Front End (IFE) System Presenter: Kwame Bowie PPD/EED Phone: (630)
Multichannel Analyzers A multichannel pulse-height analyzer (MCA) consists of an ADC, a histogramming memory, and a visual display of the histogram recorded.
Development of novel R/O electronics for LAr detectors Max Hess Controller ADC Data Reduction Ethernet 10/100Mbit Host Detector typical block.
David Nelson STAVE Test Electronics July 1, ATLAS STAVE Test Electronics Preliminary V3 Presented by David Nelson.
3D Micromanufacturing Lab. School of Mechatronics Gwangju Institute of Science and Technology 3D Micromanufacturing Lab. School of Mechatronics Gwangju.
Preliminary Design of Calorimeter Electronics Shudi Gu June 2002.
Electronics for PS and LHC transformers Grzegorz Kasprowicz Supervisor: David Belohrad AB-BDI-PI Technical student report.
MICE CM18 June 07Jean-Sébastien GraulichSlide 1 Detector DAQ Status o Since CM17 o Detector DAQ software o Front End Electronics o Schedule Milestones.
E906/Drell-Yan: Monte Carlo, Data Acquisition and Data Analysis Paul E. Reimer Expected Rates and Monte Carlo (WBS 2.5.1) Data Acquisition (WBS 2.4) –CODA.
Prototype Test of SPring-8 FADC Module Da-Shung Su Wen-Chen Chang 02/07/2002.
CARIOCA (Cern and RIO Current Amplifier). The CARIOCA chip has 8 binary output, therefore DIALOG has 16 PCH as input channels and has up to 8 LCH as output.
U N C L A S S I F I E D FVTX Detector Readout Concept S. Butsyk For LANL P-25 group.
Leo Greiner IPHC meeting HFT PIXEL DAQ Prototype Testing.
K.C.RAVINDRAN,GRAPES-3 EXPERIMENT,OOTY 1 Development of fast electronics for the GRAPES-3 experiment at Ooty K.C. RAVINDRAN On Behalf of GRAPES-3 Collaboration.
Figure 1: ICD Single Channel Block Diagram Schematic PMT High Voltage Supply (see Figure 4 & 4a) LED Pulser PMT Calibration (see Figure 6) ICD Scintillator.
Commissioning of ICAL prototype detector electronics B.Satyanarayana TIFR, Mumbai.
HBD FEM the block diagram preamp – FEM cable Status Stuffs need to be decided….
BI day 2011 T Bogey CERN BE/BI. Overview to the TTpos system Proposed technical solution Performance of the system Lab test Beam test Planning for 2012.
ICARUS General Trigger Design Contributions from: M.Della Pietra, A.Di Cicco, P.Di Meo, G.Fiorillo, P.Parascandolo, R.Santorelli, P.Trattino B.Baboussinov,
Status of Global Trigger Global Muon Trigger Sept 2001 Vienna CMS-group presented by A.Taurok.
Update on the HBD Craig Woody BNL DC Meeting June 8, 2005.
HBD FEM Overall block diagram Individual building blocks Outlook ¼ detector build.
CPT Week, April 2001Darin Acosta1 Status of the Next Generation CSC Track-Finder D.Acosta University of Florida.
Hall D Online Meeting 27 June 2008 Fast Electronics R. Chris Cuevas Jefferson Lab Experimental Nuclear Physics Division 12 GeV Trigger System Status Update.
SNS Integrated Control System Timing Clients at SNS DH Thompson Epics Spring 2003.
Front-end readout study for SuperKEKB IGARASHI Youichi.
Serial Data Link on Advanced TCA Back Plane M. Nomachi and S. Ajimura Osaka University, Japan CAMAC – FASTBUS – VME / Compact PCI What ’ s next?
NUMI Off Axis NUMI Off Axis Workshop Workshop Argonne Meeting Electronics for RPCs Gary Drake, Charlie Nelson Apr. 25, 2003 p. 1.
January 31, MICE DAQ MICE and ISIS Introduction MICE Detector Front End Electronics Software and MICE DAQ Architecture MICE Triggers Status and Schedule.
March 9, 2005 HBD CDR Review 1 HBD Electronics Preamp/cable driver on the detector. –Specification –Schematics –Test result Rest of the electronics chain.
Update on final LAV front-end M. Raggi, T. Spadaro, P. Valente & G. Corradi, C. Paglia, D. Tagnani.
7/28/2003DC/EC Review Aerogel Read out Electronics K. Ozawa, N. Kurihara, M. Inaba, H. Masui T. Sakaguchi, T. Matsumoto.
L.Royer– Calice LLR – Feb Laurent Royer, J. Bonnard, S. Manen, P. Gay LPC Clermont-Ferrand R&D pole MicRhAu dedicated to High.
Connector Differential Receiver 8 Channels 65 MHz 12 bits ADC FPGA Receive/buffer ADC data Format triggered Events Generate L1 Primitives Receive timing.
B.Satyanarayana Department of High Energy Physics Tata Institute of Fundamental Research Homi Bhabha Road, Colaba, Mumbai,
Peter LICHARD CERN (NA62)1 NA62 Straw tracker electronics Study of different readout schemes Readout electronics frontend backend Plans.
Time and amplitude calibration of the Baikal-GVD neutrino telescope Vladimir Aynutdinov, Bair Shaybonov for Baikal collaboration S Vladimir Aynutdinov,
TPC electronics Status, Plans, Needs Marcus Larwill April
Nov 1, 2007 IEEE NSS & MIC 2007 by C. Y. Chi 1 A Faster Digitizer System for the Hadron Blind Detector in the PHENIX Experiment Cheng-Yi Chi Nevis Lab.
Electronics Workshop GlueX Collaboration Meeting 28 March 2007 Fast Electronics R. Chris Cuevas Group Leader Jefferson Lab Physics Division Topics: Review.
1 Timing of the calorimeter monitoring signals 1.Introduction 2.LED trigger signal timing * propagation delay of the broadcast calibration command * calibration.
Vladimir Zhulanov for BelleII ECL group Budker INP, Novosibirsk INSTR2014, Novosibirsk 2014/02/28 1.
Analog Trigger for CTA MST CTA MST Trigger & Integration Meeting Berlin, 7 November 2011 Luis A. Tejedor on behalf of GAE-UCM, IFAE & CIEMAT groups 1.
29/05/09A. Salamon – TDAQ WG - CERN1 LKr calorimeter L0 trigger V. Bonaiuto, L. Cesaroni, A. Fucci, A. Salamon, G. Salina, F. Sargeni.
Overview of E906 Electronics, Readouts, and DAQ System E906 DAQ workshop Ting-Hua Chang (7/6 – 7/7/2009)
Status of CR Latch, Pre-Amplifier Discriminator Modules
DAQ ACQUISITION FOR THE dE/dX DETECTOR
Jinfan Chang Experimental Physics Center , IHEP Feb 18 , 2011
CTA-LST meeting February 2015
PSD Front-End-Electronics A.Ivashkin, V.Marin (INR, Moscow)
CMS EMU TRIGGER ELECTRONICS
Hall A Compton Electron detector overview
Front-end electronic system for large area photomultipliers readout
A Fast Binary Front - End using a Novel Current-Mode Technique
LHCb calorimeter main features
RPC Front End Electronics
BESIII EMC electronics
Status of muon monitor R&D and construction
RPC Front End Electronics
HallD Collaboration Meeting Jefferson Lab December 11-13, 2003
PID meeting Mechanical implementation Electronics architecture
PHENIX forward trigger review
Presentation transcript:

The Taiwan group Institute of Phys, Academia Sinica: Wen-Chen Chang, Yen-Chu Chen, Da-Shung Su Ling-Tung U: Ting-Hua Chang Committed responsibility: Build the preamplifier-discriminators cards for 5500 tracking channels in Station 1 MWPC and for 400 channels Proportional tubes in Station 4, Build the readout system for Coincidence Registers (CR), which consists of the CR modules for 5500 tracking channels in Station 1 MWPC, for 400 channels Proportional tubes in Station 4, and for 250 channels of the hodoscope planes in all stations, Participate in the Trigger upgrade project – contribute 2 commercial FPGA logic units and 1 graduate student.

From E906 proposal

Funding Profile ~ 300 K USD requested in a 3-year proposal for the hardware from National Science Council of Taiwan Waiting on approval this July. Other source: AS Theme Project. 50K USD in addition. Available in the beginning of 2010.

Requirement of PreAmp: Fast, high-gain, low-noise Initial ionization: 5e (E871 NIM paper) Gas gain: 10^5 (E871 NIM paper) 10% of total avalanche charge collected in 10 ns. 1ns rising time  350 MHz BW; 10 ns  35 MHz BW Input capacitance: 30pF (software simulation of the present layout) Input impedance:<140 ohm (software simulation of the present layout. From Page 8 at 60MHz) Charge at circuit input: 5*(1.6*10^-19 C)*(10^5)*0.1=8*10^-15 C=8fC Current at circuit input: (8*10^-15 C)/10ns= 800 nA Voltage at circuit input: (8*10^-15 C)/30 pF= 267  V Trans-impedance gain: 100K ohm (set by chosen components) Voltage at output: 800nA*100K ohm=80 mV Gain: 80mV/8fC=10 mV/fC Voltage Gain: 80mV/267  V=300 Input noise from circuit: < 5.3  V at 35 MHz  <

Figure 1. Block diagram of PreAmp-Discriminator Card Transimpedance amplifier (TIA) Comparator LVDS outputInput pulse Current-Feedback OPA Low input impedance High slew rate Transimpedance gain, Gz=5kΩ Voltage Gain=20V/V +/-5V DC power supply +5V DC power supply Hysteresis current mirror Latch/Hysteresis control O.C. gate Latch input Duplicate to other 15 channels Differential amplifier Currently, the threshold is set by potentiometer on the prototype card.

Figure 2. Schematic of PreAmp-Discriminator Card

Input impedance : <140Ω Transimpedance gain : 100KΩ -3dB Bandwidth : ~60MHz Wide linear Input current range : +/-25uA Differential voltage output swing : +/-2.58V ESD protection diodes and LVDS comparator are not shown. Differential Voltage AmplifierTransimpedance Amplifier Current generator (Current In) Differential voltage out Circuit simulation with TINA-TI design software The simulation result in plots shown in next two pages.

Large input current vs output voltage Small input current vs output voltage DC analysisAC analysis Small-signal sine-wave response Large-signal sine-wave response

Input impedance vs. frequency (with current-limited series resistor, 100Ω) AC transfer characteristic Transimpedance gain vs. frequency Input voltage noise density (without current-limited series resistor, 100Ω) Noise analysis Input current noise density (without current-limited series resistor, 100Ω)

624Kev Electron source

Positive LVDS output Negative LVDS output Input signal Sensitivity polarity Input polarity vs. LVDS output. First use pulse generator as the input Agilent 33120A waveform generator, Tektronix TDS 754D Oscilloscope, +/-5.0V operation for PreAmp card

Input to PreAMP Amplified Signal Comparator Response

Input to PreAMP Amplified Signal Comparator Response

Input to PreAMP Amplified Signal Comparator Response

Input to PreAMP Amplified Signal Comparator Response

Input to PreAMP Amplified Signal Comparator Response

Amplifier / Discriminator Card :IPAS Version Current-feedback trans-impedance amplifier. Low input impedance. Voltage gain = 300. (can be dropped) RMS of noise level~10mV. Better reproduce of original input pulse shape. S/N ratio improved after amplification Use DAC line to set the threshold is possible and preferred.

Amplifier / Discriminator Card :LANL Version Voltage-feedback trans-impedance amplifier. Large input impedance. Voltage gain = 200. RMS of noise level~10mV. Observe long tail of input pulse due to large input impedance.

Input to PreAMP Amplified Signal Comparator Response

Input to PreAMP Amplified Signal Comparator Response

Input to PreAMP Amplified Signal Comparator Response

Questions to be answered The R-C configuration on the detector side: How to interface between preamp and chamber? Chamber geometry (pin output arrangement) Latch frequency: 53MHz? Voltage gain appropriate? Threshold of comparator: mV (enough?) Noise level during the run? Maximum pulse width from MWPC? (signal tail pile up) Q: Get power from chamber? Separate power supply?

Two possible schemes of preAmp-Latch-CR readout system 1. MWPC—2 preAmp cards—1 Latch- CR VME module—VME Buffered Encoder—VME Event Buffer Interface 2. MWPC—4 preAmp cards—1 Latch- CR Card—VME Event Encoder/Buffer

A Coincidence Register readout system – follow E871 Design #1 Each detector owns their EB (VME crate?) Parallel paths to EBI for different detectors

Last quad doublet about 200’ upstream Counting Room ~60ft MWPC to electronic platform ~ 100 ft. Exceeds LVDS limit (20m) from preamp Change preamp output to ECL? Racks on floor OK? Trigger decision

Each latch CR module contains: A total of 32 LVDS inputs Two 1024x16-bits latch based shift register One 2048x32-bits Level-2 event memory Read control unit based on Xilinx Vertex FPGA NIM signals: Gate, Trigger, Fast clear, Full/Space-available Standard VME A24/D32 interface Interrupt VME 6U backplane MWPC latch system Figure 1 Design #1 cont’

Design #1 Data from PreAmp sent to Latch-CR where the state of each channel is latched with RF clock. Data are collected to EB then to EBI at L1 trigger with data reduction. If L2 does not occur, clear EBI. Data in EBI sent out to DAQ at L2 trigger Delay of digital signals in FPGA and comparator threshold in PreAmp can be remotely adjusted via VME CPU.

# 2 design 16-channel PreAmp/ Discriminator Card MWPC 5500 channels 64-channel CR Module 16-bit LVDS driver 16-bit LVDS 1 16-bit LVDS 2 16-bit LVDS 3 16-bit LVDS 4 FPGA Shift Register Data Compressor Level-1trigger RF clock DAQ Connector Twisted cable VME Event Buffer VME CPU Optic fiber R/W Lines VME Event Buffer Level 2 Trigger VME crate

Design #2 CR card: –Sits next to PreAmp card and retrieves power from MWPC via LVDS cable connection from PreAmp. –Data clocked into shift registers at RF freq. –With L1 trigger enabled, perform data encoding, and at L2 trigger send data to VME Event Buffer board. –Uses 1 optic fiber for R/W communication with VME Event Buffer board. –Data transfer rate of optic fiber: 1.25Gbps ~ 4.25Gbps Event Buffer board: –Each EB connects with 16 optic fibers. –Data readout from EB to DAQ at L2 trigger after data is collected from 16 CR cards.

Questions to be answered for #2 Distance from spectrometer to electronics? Radiation damage? L1 & L2 trigger rate? (Is 1 optic fiber enough?)

Information & Estimation Main Injector RF clock frequency: 53 MHz. Beam structure: 10^13 protons in a 5 s slow extraction spill every minute. Beam intensity: 2*10^12/sec. 200 triggers/per spill; 1kHz trigger rate aimed for DAQ. (??) Level-2 trigger latency: Master Trigger OR decision time= 91ns. Level-1 trigger rate (X): –MWPC designed Singles rates:53MHz.(?) –The total rate of single muons traversing the detector and passing the trigger matrix tracking will be approximately 100 kHz with the LH2 target and 150 kHz with the LD2 target (both cases include tracks originating in the beam dump). LVDS clock: minimum 200 MHz. How many 16-channel preamp cards which one latched module can deal with: (16bit*200MHz)/ (16bit*53MHz)~4. Event size of MWPC W/O data reduction: 5500bit=0.8kB Depth of memory buffer: 53MHz*91ns~ 5 events. Size of total memory to buffer 5 events=0.8kB*5=4kB. VME transfer throughput:0.8kB*1kHz=0.8MB/per sec << Optic fiber ~100 MB/sec and VME 160 MB/sec. Deadtime-free is possible.

Schedule for building PD cards All R&D and testing work would be done in IPAS electronics lab. Aug Jan 2009 – R&D PD card prototype. First few PD prototype cards produced. Test gain, rising time and invest noise pick up. Jan 2009 – Mar 2009 – Send prototype cards to US collaborator to test with MWPC chamber. Finalize prototype design. Mar – Aug 2009 – Mass production. Manufacture the rest (~350) cards. Testing. Aug – Sept All cards shipped to Fermilab for final integration.

Schedule for building CR modules Aug - Sept 2008 – R&D CR module prototype. First 2 CR prototype modules produced. Develop readout software for multi-boards. Sept – Dec 2008 – Set up testing environment with a simple DAQ system. Trigger rate will mimic the running condition. Finish testing first set of prototype boards. Finalize prototype design. Jan – Mar 2009 – Manufacture first 20 boards, test serial/parallel multi- crates readout, test throughputs and event formatting, developing readout software for multi-crates. Set up a DAQ system using JLab CODA in local lab. Mar – Aug 2009 – Mass production. Manufacture the rest (~ 160) boards. Full system test completed. Aug – Sept All modules and crates shipped to Fermilab for final integration. Sept 2009 – Feb 2010 – Crew on site. Install CR modules and PD cards to MWPC. Preparation for the experiment. Mar 2010 –Scheduled start of E906 data taking? The Ph.D student and Yen-Chu Chen will stay in Fermilab full time.

Schedule

Unix host running CODA Ethernet Hub Data Storage Online monitoring Data Decoder Software MWPC, HODO, Muon Coincidence Register System, VME CAMAC TDC for DC Interface to VME Accelerator scalers, VME? Conceptual design of DAQ based on CODA Electronics House Counting House ROC1 ROC2ROC3 L2 Trigger

DAQ CODA is a DAQ software developed by CEBAF –Provide user interface –Internet based –Event fragment checking & tagging –Flexible configuration, system is easy to expand by adding more ROCs Reasons to use CODA (open to other options) –Allow all sub-system be developed locally & independently. –Final integration is straightforward. –Technical support available from JLab –Have experienced people among us

DAQ (cont’) Each sub-system needs a “trigger interface” to synchronize event readout. Each sub-system needs to develop its readout control code in CODA standard Need new decoder program. Packet formatter might not be needed. Need collaborators take responsibilities on each projects. Final integration and testing of all electronics? (Software + Hardware) Plan and schedule need to be work out.