Www.lightsource.ca CLS Machine Status Displays System Analyst - Controls Canadian Light Source Inc. web: www.lightsource.cawww.lightsource.ca 101 Perimeter.

Slides:



Advertisements
Similar presentations
CLS Process Variable Database By: Diony Medrano. CLS PV Database - Topics Background Design Constraints Design and Implementation Benefits and Future.
Advertisements

The Implementation of Top Up Operation at the Australian Synchrotron Light Source Don McGilvery.
New Radiation Safety Interlock System for the SPring-8 Accelerator Complex C. Saji, M. Toko, T. Matsushita, R. Furuta, H. Hanaki, S. Hashimoto 1), Y. Hashimoto,
1 BROOKHAVEN SCIENCE ASSOCIATES NSLS-II Shielding Workshop S. Buda Personnel Protective Systems March 27, 2007.
The applications of FA-M3 PLC used in SSRF ZHOU Dayong
Best Ever Alarm System Toolkit Kay Kasemir, Xihui Chen, Katia Danilova SNS/ORNL April, 2013.
Chapter 11 Exploring Windows XP Vol. 1 Part One - Windows XP Professional: The Basics.
Patrick Krejcik LCLS April 16-17, 2007 Breakout Session: Controls Controls Commissioning Experience.
11 3 / 12 CHAPTER Databases MIS105 Lec14 Irfan Ahmed Ilyas.
SNS Integrated Control System SNS Machine Protection System EPICS Workshop April 27, 2005 Coles Sibley.
1 Chapter 13 Embedded Systems Embedded Systems Characteristics of Embedded Operating Systems.
Integrating Acquired Subsystems Bob Dalesio 09/21/99.
Elder Matias CLS Control System Recent Upgrades. Major Changes Synchrotron Upgrade New Isotope Production Linac EPICS Software –Python EDM –Aquaman –ScienceStudio.
EPICS on TPS RF System Yu-Hang Lin Radio Frequency Group NSRRC.
Managed by UT-Battelle for the Department of Energy Kay Kasemir ORNL/SNS Jan Control System Studio Training - Alarm System Use.
Managed by UT-Battelle for the Department of Energy Kay Kasemir ORNL/SNS April 2013 Control System Studio Training - Alarm System Use.
HiVision SNMP Software.
2 Instructor Training MPTT Flow Loop System VLP-TRN-MPTT.
All content in this presentation is protected – © 2008 American Power Conversion Corporation Symmetra ® LX – redundant UPS High performance, redundant.
Computer Literacy BASICS: A Comprehensive Guide to IC 3, 5 th Edition Lesson 3 Windows File Management 1 Morrison / Wells / Ruffolo.
1.1 1 Introduction Foundations of Computer Science  Cengage Learning.
SNS Integrated Control System EPICS Collaboration Meeting SNS Machine Protection System SNS Timing System Coles Sibley xxxx/vlb.
SSRF Beamline Control System
Workshop “Vacuum systems of Synchrotron Light Sources“ organized by MAX-LAB & ALBA Barcelona, th September 2005 Instrumentation and Vacuum Control.
Control and Monitoring System / EPICS Pete Owens Daresbury Laboratory.
SMACS Slow Monitor And Control System Developed system for CDF-TOF proposed for Atlas-MDT/RPC.
Components of Database Management System
Interacting with IT Systems Fundamentals of Information Technology Session 5.
Software Aspects of PQ in a DG Context By Dr. Siri Varadan.
E.Matias Canadian Light Source. Where is Saskatoon?
1 Kenneth Osborne, 9/14/07 Inter Group communications at the Advanced Light Source. Overview of the different methods of communication between different.
CLS Machine Protection and PLC Hardware Presentation to Beamlines Group Elder Matias Canadian Light Source University of Saskatchewan October 20, 2001.
Slide 1 RDU Data Collection System Overview. Slide 2 * The RDU data system is, primarily, an RF-Tag-based system. * All process information and test results.
Elder Matias, Diony Medrano, Dong Liu (At Michigan State University - Nov 2011) IRMIS at CLS.
Stephen Schuh Vacuum Controls SCR and 16 November 2005 Vacuum Controls System Concept Review and Preliminary Design Review.
CLS Control System Progress Report Elder Matias Canadian Light Source University of Saskatchewan Saskatoon Saskatchewan.
EEDEED Tuesday, May 18, VBA & Process Variables  System Overview  Setup (What installations are needed)  What are Process Variables and what.
Adrian Oates Daresbury Laboratory ALICE Control System July 08.
HC Review, May 2005 Hardware Commissioning Review Hardware Commissioning Review Quality Assurance and Documentation of Results Félix Rodríguez Mateos,
Control Hardware Design Control Hardware Wiring IOC Software (Low Level) OPI Software (High Level) Final Test Front-End (Connection to SR1 Ring) Done Insertion.
1 BROOKHAVEN SCIENCE ASSOCIATES Redundancy Requirements for Critical Devices R. Casey August 8, 2007.
C OMPUTING E SSENTIALS Timothy J. O’Leary Linda I. O’Leary Presentations by: Fred Bounds.
EPICS Application Development At The Canadian Light Source Glen Wright.
Foundations of Technology The Systems Model
1 B. Braun SpaceStation – Product details Overview Flexibility in use Typical configurations.
A U.S. Department of Energy Office of Science Laboratory Operated by The University of Chicago Argonne National Laboratory Office of Science U.S. Department.
Managed by UT-Battelle for the Department of Energy SCL Vacuum Control System Upgrade Derrick Williams
CHAPTER 7 Exploring Microsoft Windows 7. Learning Objectives Identify the parts of the Windows 7 desktop Use common Windows elements Navigate Windows.
11 th February 2008Brian Martlew EPICS for MICE Status of the MICE slow control system Brian Martlew STFC, Daresbury Laboratory.
Strategic Marketing ICU&OR Systems Nov 13, 2003 Chapter Sales Manual B.Braun Space Chapter 5.3  Overview  Flexibility in use  Typical configurations.
April 2005OLAV Workshop Diamond Vacuum Controls Hugo S Shiers.
Control System Considerations for ADS EuCARD-2/MAX Accelerators for Accelerator Driven Systems Workshop, CERN, March 20-21, 2014 Klemen Žagar Robert Modic.
Safety Interlocks Group Front End Equipment Protection System Currently there are 55 FEEPS Systems in Service –This consists of: 43 Version 1 system 4.
Project X RD&D Plan Controls Jim Patrick AAC Meeting February 3, 2009.
Employment of scada system in water purification and transmission system.
Safety and health at work is everyone’s concern. It’s good for you. It’s good for business. Improvement of OiRA Presentation of the new features to the.
An overview of I&C Systems in APR 1400 Parvaiz Ahmed Khand December 28, 2007.
Failure Analysis Tools at DESY. M. Bieler, T. Lensch, M. Werner, DESY ARW 2013, Melbourne,
HUAWEI TECHNOLOGIES CO., LTD. Huawei Storage ISM Management Pre-sales Product Training Materials Easy and Efficient WEU IT Solution Team.
Reliability and Performance of the SNS Machine Protection System Doug Curry 2013.
Operations Machine Simulator.
Reveal™ Touch Screen Product Overview
Laboratorio per dottorandi 2017 Particle Accelerators Control System
PLC-based control systems at SOLEIL - ICALEPCS 2017
DLS Standard PLC System
Control System Studio (CSS)
RF Local Protection System
High Level applications development status
The Human Computer M Adair.
Vacuum Controls Stephen Schuh Tom Porter 25 October 2006
Presentation transcript:

CLS Machine Status Displays System Analyst - Controls Canadian Light Source Inc. web: Perimeter Road The University of Saskatchewan Room: 1009 Saskatoon SK S7N 0X4Phone: (306) Canada By Hao Zhang

Topics Topics Background Goals Screen and Display Design Injection/Machine Status Screen Machine Protection Screens Integrated Master Displays Benefits and Future Questions

Background Operators need to monitor and control a number of processes, systems, devices, and equipments. EPICS PVs (Process Variable) and EDM (Extended Display Manager) screens based on the PVs are created for this purpose. The operation of the synchrotron is a complicated process. The numbers of PVs and EDM screens involved can be overwhelming

Goals A quick and easy way to give the operator a snapshot of the machine status at one glance A quick and easy way to navigate through different EDM screens A quick and easy way to pin point each individual PV when necessary A quick and easy way to locate the problematic component when a machine trip happens A centralized location to put all involved PVs and screens together

Screen and Display Design Injection / Machine Status Screen Machine Protection Screens Integrated Master Displays

Injection/Machine Status Screen Grid status indicator matrix: How PVs are organized? Row : sub-systems Column: key components

Injection/Machine Status Screen Indicator color definition: How status is represented?

Injection/Machine Status Screen Related displays - links to other EDM screens Indicator matrix - a snap shot of the big picture Sub-screens - display components info in a sub-system Navigation through the Injection/Machine Status Screen:

Injection/Machine Status Screen Group Status: combine all component status together A group status PV is created to indicate the collective status of a group of components in a sub-system. The group status PV monitors all individual PVs in this group and calculates the combined status. Different algorithms are used for different types of PVs. Eg. finds out the highest alarm level in the group and pass it to the group PV.

Injection/Machine Status Screen Example: pass highest alarm to the group PV

Machine Protection Screens Overview of CLS Machine Protection Systems (MPS) Tasks: monitors vacuum status using ion pumps, cold cathode gauges, multi gauges, etc. monitors device cooling status using flow switches, flow transmitters, thermo couples, RTDs, etc. shuts down vacuum valves/photon shutters, disables Gun/ RF, for VACUUM PROTECTION/DEVICE PROTECTION when necessary interface with other systems such as the personnel safety system, modulator controls, and other machine protection systems Components of a typical MPS: a PLC system a hardware interlock system/a redundant PLC system

Machine Protection Screens Machine Protection Screens: display device status provide operator controls helps diagnose problem

Machine Protection Screens Example: LINAC Machine Protection Screen

Machine Protection Screens Example: Hard X-ray MicroAnalysis (HXMA) Frontend and Beamline Machine Protection Screen

Machine Protection Screens Similarities to the Injection Status Screen: Devices are organized into groups Group status is represented by the color of its indicator For some indicators, sub-screens can be brought up and displayed in an embedded window. Related displays are provided when necessary to access more detailed information

Machine Protection Screen Bypass: Who got bypassed? bypass indicator regular indicator

Machine Protection Screen Latch indicator: Who tripped the machine? regular indicator latch indicator the component tripped the machine will be latched latch indicators appear around the component indicator and its group indicator, and so on latch indicators keeps showing until the latch is cleared even if the component status is GOOD No new latch indicators will appear as long as the current latch is not cleared

Machine Protection Screen Latch example:

Integrated Master Displays The injection status screen and LINAC machine protection screen cover two important aspects of LINAC operation. However, they are not the only screens involved. There are also other screens such as the power supply status and vacuum status screens. A master display contains tabbed windows is therefore developed to integrate those screens into one single display. Example: LINAC Master Display

Integrated Master Displays Example: LINAC Master Display

Integrated Master Displays Example: Beamline Master Display

Benefits Simple, self-explanatory, and user friendly Better organization of PVs and control screens A handy tool to help identify problems Shortened the average time taken to return the storage ring to service after a trip

Future More indicators are to be added into the grid status indicator matrix as new devices are installed into the system More screens are to be integrated into the master displays as the system evolves Considering extend the indicator color key definition so that more status can be identified.

Questions ?