SieTec Security Ltd RD-RLY01DIN DIN Rail Mount Programmable Relay with RING DETECT USB Programmable Relay Unit Specification December 2011 Your Systems.

Slides:



Advertisements
Similar presentations
Prescient II Extinguishing Control Panels
Advertisements

GSM Relay Controller. GSM Power Supply Voltage must be between 10 – 14vdc.
SieTec Security Ltd What we Do? What Technologies do we USE? Projects and Project Management Product Training Contact information Your Systems Integration.
MEGATRON. Privately owned shares company founded at The company is engaged in manufacturing Measu- rement, Monitoring and Control equipment. Megatron's.
JED Microprocessors Pty Ltd Presenting the JED T430 low-cost Projector Controllers Nov 22nd, 2009.
26/2704 Vacuum Feature What is vacuum Vacuum in industry
Model W Wall Mount Static Transfer Switch. Why choose a model W static transfer switch? Increases power availability. Integrated maintenance bypass. True.
Arctic IEC-104 Gateway Jari Lahti, CTO.
GE job title/1 GE internal information - Not for external distribution 1 GE Security EMEA NPI template – v1 1X Series (phase 1) Conventional Fire Panel.
PLC Timer Instructions
PYROCON12 De-Ice controller Technician Operation Presentation 2013.
Inputs: Digital and 4 configurable for Digital or 10 bit Analog Outputs:4 - 8 amp Relays or 700ma Transistors (1 PWM) 4 Line by 18 Character fully.
Discrete Control Logic 1. Pneumatic circuits - Low forces - Discrete, fixed travel distances - Rotational or reciprocating motion Main components: compressor,
WELCOME. Controllers Controller 1/32 DIN FKS SMART function for the self-tuning of control parameters. TC, RTD or linear input programmable. Dual Outputs,
SieTec Security Ltd Case Studies 1 Your Systems Integration Specialist.
Ladder Logic PLC Programs are made up of combinations of AND; OR; NAND; NOR; and other gates, along with timers, inputs, outputs, counters, comparators,
EUT 1040 Lecture 10: Programmable Logic Controllers.
Introduction To Programmable Logic Controllers
EUT 1040 PLC Timers and Motor Protection. Industrial Communications RS-422 (EIA 422): Asynchronous Serial Communications, similar in many respects to.
Industrial Solar Power PoE Switch
PYROCON12 De-Ice controller User Operation Presentation 2013.
TEST YOUR BRAIN! Components.
Pump Application Interface. 30 October 2006 Overview Increases the functionality of the soft starter for pumping applications - four additional trip inputs.
Office of Emergency Communications Gateway Training Workshop Module Three Hands-on Configuration Incident Commanders Radio Interface (ICR)
Overview of the 1.
SB-CMS-PIR - ceiling mounted PIR sensor. Subnet ID and Device ID Device Remark Change the ID if needed.
RP-2000 Series Deluge & Agent Releasing Panels
Mini8 Multi-loop Controller. 2 Eurotherm Business Group Mini 8 – What is it? Multi-loop(4,8,16) PID controller 8-32 Channel data acquisition Design targeted.
Arctic Control Introduction V 1.0. Arctic Control The Arctic Control is a device with integrated wireless communications for controlling medium-voltage.
Looking for a more powerful circuit monitor?
1 PAC530 | Output Controller. 2 The Output Controller (PAC530) provides the local connection on an RS-485 network between an Access and Alarm Server (PAC500)
Regal Beloit Proprietary & Confidential What do I get? The X13 motor is a permanent magnet, three phase,brushless DC motor. A single phase drive is attached.
The PAX Lite: PAX quality at a great low price.. PAX Lite Series Indication and Setpoint Control Simple field set-up Perfect the low-cost meter users.
Khaled A. Al-Utaibi  The Push Button  Interfacing Push Buttons to Arduino  Programming Digital Inputs  Working with “Bouncy”
Discrete-state Process Control
PROGRAMMABLE LOGIC CONTROLLER (PLC) AND AUTOMATION
Electro Eye-Hye System II
Digital Temperature Switches The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and.
Serial Transmission System Series EX510 BackgroundFeaturesTechnical detailsApplications.
Prepared by: Engr. Qurban Ali Memon 11ES (SEC- 1 & 2)
New product introduction:
PRESENTATION ON THE TOPIC By: Rahul agarwal. INTRODUCTION  Overload protection circuit are required in inverters and uninterrupted power supplies to.
CX5A PC Programmable with 2-RS232 Ports. CX5A  Product Description A wall mounted UHF Alphanumeric, Numeric and Tone/Vibrate only Local Area Paging Transcoder.
AND Gate Inputs Output Input A (Switch) Input B (Switch) Output Y (Lamp) 0 (Open) 0 (OFF) A B Lamp.
ACT20X Ex isolator/ amplifier. Page 2 ACT20X (Ex isolators family) Overview - Connects to process equipment in Class/Div, or Zone 0 - Zone 2 areas - ACT20X.
Arduino “Getting Started” Instructor : Dr Matthew Miss Khin Yi Kyaw
Programmable Logic Controller
E Control Devices have a wide range of Latching Relays. The range of latching includes Relays, 16 Amp Latching Relays, 30Amp Latching Relays, 80 Amp Latching.
Lecture 10: Programmable Logic Controllers
PICAXE Microcontroller
User Operation Presentation
KX-HTS Step by Step Guide KX-NTV
The Multi Series DL2-Multi
ConneXions.
Dial (844) | How to Fix HP Printer Error 0x61011be5 ?
TORQUE MEASURMENT.
HOW TO RESET BROTHER PRINTER HL 2250DN Quick step up Guide to reset your Brother Printer HL 2250DN
Call to Fix Brother Printer in Error State
NT24k® & 1000 PoE+ Offerings October 2016.
Manisha Goel, Lecturer, EE Deptt Govt. Polytechnic Manesar
PLC’s Are ... Similar to a Microcontroller: Microprocessor Based
Technician Operation Presentation
IRRInet-M IRRInet-ACE Product Introduction
Programmable Logic Controllers (PLCs)
Model Output Current Battery Life BATPSU VDC 2A 1.2Ah BATPSU VDC 2.3Ah
PAX2A Release.
Universal Interrupted Electronic Oil Primary R7184U Training Module
Presentation transcript:

SieTec Security Ltd RD-RLY01DIN DIN Rail Mount Programmable Relay with RING DETECT USB Programmable Relay Unit Specification December 2011 Your Systems Integration Specialist

RD-RLY01DIN The RD-RLY01DIN has been designed for industrial applications and comes with many features. 24Vdc to 60Vdc Operation 24 to 100Vac Ring Voltage Detect R-R Relay Output 60Vdc 1Amp resistive load MAX F - FET Output 60Vdc 1Amp resistive load MAX Telephone inline connection Ring Detect Off Hook Detect (current detect) PABX Message Waiting Detect (voltage detect) 3 Logic Inputs (clean contact input) 2 programmable to an assigned output (future) 1 Latching Reset to an assigned output (future) It comes complete with a serial port for programming Optional USB Programming cable available along with programming guide and software We can program the standard features for you OR. Factory custom programming available if required

Features Programmable Features. Program specific input functions to outputs Either Output Assign to input Follow ring cadence Hold steady between ring cycle Pulse 0.25s / 0.25s during hold period Latch steady output until reset Latch and pulse 0.25s / 0.25s until reset Time delay output before switching “ON” 0 to 99sec Time output “ON” before release 0 to 99sec Inputs Line In, 1, 2 and 3 Line In/Out – Telephone Line in/out Input 1 assign to an output Input 2 assign to an output Input 3 is Latch Reset (if Latch is used) not programmable as always ON. Default Programming Output 1 Follow Ring Cadence Output 2 Follow Ring Cadence Off Hook – OFF Message Waiting - OFF Delay Timer 0 seconds Output Timer 0 seconds Line Input Inputs 1,2 & 3 – Not assigned

Contact information Auckland OfficePhone AK Fax Contact Name Myles Russell Auckland Web Pagewww.sietecsecurity.co.nz AddressPO Box , Glen Innes, Auckland 7 Domain Rd, Panmure, Auckland