Selecting A FoamPro System. 153 Class A foam concentrates –NFPA 1150 or US Forest Service Approved Class B foam concentrates –Use of a lower % foam concentrate.

Slides:



Advertisements
Similar presentations
Types of Concentrates (Water Additives). 13 Foam Concentrate - Water Additives Wetting agents Class A foam concentrate –Class A Foam Class B foam concentrate.
Advertisements

DRIP DISPERSAL SYSTEMS Problems and Solutions Presented by Keith Surface.
Firefighting Foam.
FoamPro 1600 Series Fully automatic Class A foam ONLY
CAFS On-Line Orientation
Fire Streams Geronimo Vol. Fire Dept.. Extinguishing Properties of Water G Water extinguishes fires by G Cooling G Remove heat from the fire G Smothering.
Driver Recert 2012 Topics Update on Fire Hose Friction Loss Coefficients Fire Flow Through Long LDH Supply Lines Rural Water Supply Flow Rates Booster.
Cycle Stop Valves 1” through 16” 1 GPM to 10,000 GPM.
Mather Process Solutions presents the OS 200 “Oil Saver” Continuous Oil Filtration System for all of your batch and smaller conveyor frying systems. Do.
Booster System Basics: Constant Speed Systems
CNG Refuelling station. A company located in Cherasco (Italy), is among the world leaders in the field of designing and manufacturing of components and.
Solid Feed Systems SFS series of feed systems are an affordable easily maintained option for solid programs.
Proportioning Systems. 69 Proportioning Systems Now you know the benefits and uses of water additives, especially Class A foam. So how do we get the concentrate.
Pumping Apparatus Driver/Operator
Power-Fill Operation Demonstration Power-Fill Operation Demonstration (See Installation and Operation Manual for detailed instructions)
AccuMax Single Point Injection Operation (See Installation and Operation Manual for detailed instructions)
Fire Streams SFFMA Training Objectives: –
CAFS On-Line Orientation
Foam Application Rates for E85 and E-95. Application Rates Described in Terms of the Amount in Gallons of Foam Solution Reaching the Total Square Footage.
Fire Apparatus Familiarization
The 30M2 Continuous Miner. Customer Name 30M2 Overview %Heavy duty high power miner for mid-height seams %High productivity from efficient cutting and.
C L A S #4 Driver Operator Refresher Training.
2001, 2002 & 3012 Series Operation 2001, 2002 & 3012 Series Operation (See Installation and Operation Manual for detailed instructions)
FOAM APPLICATION TECHNIQUES
Sensors and Actuators John Errington MSc. Sensors and Actuators Sensors produce a signal in response to a change in their surroundings e.g. Thermostat.
Fire vs. Water Flow. What’s the best size for an “attack line?”  Maximum flow  Maximum mobility  Speed-How fast and how much  Ease of deployment and.
AccuMax Multi-Point Injection Mechanics
5.1.2 Student Book © 2005 Propane Education & Research CouncilPage 1 NFPA 58, LP-Gas Code, sets out the minimum valve and fitting requirements for propane.
CAFS On-Line Orientation Montgomery County Fire & Rescue Service Operating the CAFS Controllers.
Fuel Oil Systems Fuel Oil Systems consist of: Storage Tanks Pumps
Series Operational Training. 2 Water Tank Water Pump Multiple Discharges 2000 Series Line Strainer Foam Tank Electronic Direct Injection Proportioner.
EESIFLO International Pte Ltd
MOST RELIABLE COMBINATION MASTER VALVE, WATER METER AND FLOW SENSOR
FoamPro Features & Benefits. 139 FoamPro Systems 1600 Series 2000 Series 3012 Model AccuMax Series.
Water Handling Operations
1 CTC 450 Review Water Quality Water Quality. 2 CTC 450 Water Distribution Systems Water Distribution Systems.
Pumping Apparatus Driver/Operator
TFT Blitzfire.
MonoDrive & XT Constant Pressure Controller
The complete flow monitoring solution Measure – Display – Switch – Transmit.
5 Pumper Apparatus Overview. 5 Knowledge Objectives (1 of 2) Explain the importance of understanding the fire pump and its systems. Describe the exterior.
ENGINES. VEHICLE / HEAVY EQUIPMENT SAFETY INSPECTION CHECKLIST OF 296.
Section 703 Apparatus Inspection. Procedures The driver/operator should follow a systematic procedure for inspecting apparatus This ensures that all important.
Tweety Operation Manual. Refurbish History Motor 1) Cummings Diesel (V6), ) Red Line 3000 (hums at 2800) 3) Top Speed 60 MPH.
Learning Outcomes Upon completion of this training one should be able to: Identify hydronic chilled water system applications. Define the difference between.
Launch Chameleon Plus P - More Preventive features and safety L - More Longer Lasting and robust U - More User friendly operation S - More Service friendly.
CUE – Make Any Pump an E-Pump
Hydro Multi-B – (2) or (3) CME Pumps in Parallel
TENDERS. VEHICLE / HEAVY EQUIPMENT SAFETY INSPECTION CHECKLIST OF 296.
15 Water Supply. 15 Objectives (1 of 2) Discuss rural water supplies. Describe how portable tanks are used to supply water for firefighting. Describe.
Types of Fire Apparatus Equipped with a Fire Pump Sugar Land Fire Department Driver/Operator—Pumper Academy Spring 2003.
KP Presentation KP1 and KP2 Features. KP Designations The Godiva KP series of rear or midship mounted PTO driven centrifugal fire pumps offers the ultimate.
The complete flow monitoring solution Measure – Display – Switch – Transmit.
Apparatus Testing Sugar Land Fire Department Driver/Operator-Pumper Academy Spring 2003.
Water Shuttle Operations
2013Q2.
Foam Equipment & Systems Sugar Land Fire Department Driver/Operator-Pumper Academy Spring 2003.
 Trucks / Trains  Calculations for foam flows / PSI  Response Bulletin  Mutual Aid partners responsibilities  Air monitoring  What information do.
ATP FOAM SYSTEM Engine 438 Ansul / Rockwood Model B2 400 GPM Around The Pump Foam System.
Fire Service Pump Operator - 05 Pumper Apparatus Overview.
Fire Attack and Foam (Fire Fighter II)
WATER DEMAND (Chapter 24)
© Copyright, HQT-SV Control System
Kick-Off Webinar 2016 – 2017.
CAFS On-Line Orientation
On-Line CAFS Orientation
CAFS On-Line Orientation
FOAM APPLICATION TECHNIQUES HOSTED BY THE Jefferson County Fire and Rescue Training Academy.
FOAMPRO 2001 / 2002 Pump Panel. FOAMPRO 2001 / 2002 Pump Panel.
Presentation transcript:

Selecting A FoamPro System

153 Class A foam concentrates –NFPA 1150 or US Forest Service Approved Class B foam concentrates –Use of a lower % foam concentrate will increase the discharge capabilities; i.e., 1%x3% versus 3%x6%. –AFFF –AR-AFFF (Viscosity considerations) –Control at each discharge Emulsifiers –Viscosity considerations What Type(s) Of Foam Concentrate Do You Want To Proportion?

154 What Are Water/Foam Flow Requirements? What discharges require foam solution? –Pre-connected hand lines, trash lines, etc. –2-1/2” and/or larger discharge(s) –Deck gun or aerial waterway (secondary feed) What are min. & max. GPM requirements of solution? What are min. & max concentrate levels? Properly size proportioner, main waterway check valve and flowmeter

155 Class B Foam Sizing Considerations Performance expectations NFPA standards Storage requirements (On and off vehicle) Logistical requirements Concentrate proportioning rates Control at each discharge (AccuMax single or multi-point injection)

156 Gallons per minute of foam concentrate required Sizing The Proportioner

157 Class A Example Flow requirements –Maximum: One deck gun 500 gpm –Minimum: One 1-1/2” 35 gpm (mop up) Concentrate level requirements –Maximum 1.0% (exposure protection) –Minimum 0.3% (initial attack) Calculate concentrate requirements –Maximum: 500 gpm x 1.0% = 5 gpm –Minimum: 35 gpm x 0.3% =.105 gpm Choose pump and flowmeter from charts

158 Fuel Hydrocarbon Polar Solvents Foam Type AFFF or FFFP AR/AFFF Application.10 gpm/ft 1%.10 to.20 gpm/ft 3% Rate Formula or 3% or 6% Spill Area 50 x 50 = 2500 sq.ft. Critical Application Rate x.10 gpm/ft 2 x.17 gpm/ft gpm 425 gpm Total Foam 250 gpm 425 gpm Concentrate x 15 min x.01 = 37.5 x 15 min x.03 = 191 on Scene or x.03 = 112 or x.06 = 382 Class B Foam Application Rates NFPA 11 or Manufacturers Rate

159 The FoamPro Product Line Model Capacity (Class A foam only) gpm gpm (Class A and/or B foam) gpm gpm gpm Maximum operating pressure 400 psi Model Capacity gpm gpm gpm gpm gpm gpm Dual pump option available for flows below 3000 series minimums Maximum operating pressure 250 psi

Product Lineup Class A Single Point Injection

161 FoamPro 1600 Series Ideal applications: –Brush rigs/skid units –Fast attack vehicles –Municipal apparatus –Retrofits –Compressed Air Foam Systems Treats up to: – % – %

Product Lineup Class A And/Or B Single Point Injection

163 FoamPro 2000 Series Ideal applications: –Municipal pumpers –Wildland pumpers –Marine and shipboard –Dual foam systems –Compressed Air Foam Systems Treats up to: – % – %

164 Capabilities Of A 5.0 GPM System Class A Attack Capability % SolutionAttack Capability 0.2%2,000 GPM200,000 cu. ft. 0.5%1,000 GPM100,000 cu. ft. 1.0%500 GPM50,000 cu. ft. Solution flow and critical application rate using the Iowa formula

165 Capabilities Of A 5.0 GPM System Class B Attack Capability % SolutionAttack Capability 1%500 GPM4,980 sq. ft. 3%166 GPM1,660 sq. ft. 6%87 GPM830 sq. ft. Solution flow and critical application rate on 0.10gpm / sq ft

166 FoamPro Model 3012 Ideal applications: –Municipal pumpers –Wildland pumpers –Marine and shipboard –Dual foam systems –Compressed Air Foam Systems Treats up to: – % – %

167 Capabilities Of A 12.0 GPM System Class A Attack Capability % SolutionAttack Capability 0.2%6,000 GPM600,000 cu. ft. 0.5%2,400 GPM240,000 cu. ft. 1.0%1,200 GPM120,000 cu. ft. Solution flow and critical application rate using the Iowa formula

168 Capabilities Of A 12.0 GPM System Class B Attack Capability % SolutionAttack Capability 1.0%1,200 GPM12,000 sq. ft. 3.0%400 GPM4,000 sq. ft. 6.0%200 GPM2,000 sq. ft. Solution flow and critical application rate on 0.10 gpm / sq ft

AccuMax High Flow Industrial Systems

170 AccuMax Single Point Systems Ideal applications: –Industrial –Municipal pumpers –Airport rescue –Aerial apparatus –Compressed Air Foam Systems Treats up to: –10, % –5, %

171 Water Tank Check Valves Water Pump Multiple Discharges Flowmeter Foam Tank Line Strainer Digital Display Control AccuMax Single Point Injection

172 Size Max Accuracy Max Operating Tee Flow Range Flow Range 1-1/2x1" gpm gpm 1-1/2" gpm gpm 2" gpm gpm 2-1/2" gpm gpm 3" gpm gpm 4" gpm gpm 6" ** gpm gpm 8" ** gpm gpm ** Electromagnetic flowmeter Determine Flowmeter Requirements

173 AccuMax Multi-Point Systems Microprocessor Control –On-demand multi-point foam injection at each discharge –Unmatched accuracy across full performance range Edwards Rotary Gear Pumps –40, 60, 90, 120, 150 & 300 GPM Models –All bronze construction Use Multiple Foam Sources –Foam tank or outboard pickup

174 Superior Performance –No flow restrictions –Not affected by external factors Calibration And Testing –Easy, fast, reuse the foam Applications Include: –Industrial Apparatus, Marine AccuMax Multi-Point Systems

175 Master Control –Provides total system control and performance information –Advanced self-diagnostics Individual Line Control –Each allows plain water or choice of injection percentage –Displays line performance along with water & foam totals Digital Displays –Simple push button control –Ultra-bright LED readout AccuMax Multi-Point Systems Operations

176 AccuMax Multi-Point Line Controller & Flowmeter Sizing

177 AccuMax Multi-Point Line Controller & Flowmeter Sizing

178 Plumbing Suggestions 1-1/2" or 2" Flowmeter tee –One or two preconnects and booster lines 2-1/2" or 3" Flowmeter tee –Two to three preconnects, 2-1/2" discharge and supplemental feed to deck gun 4" Flowmeter tee –Large waterway flow i.e. preconnects, multiple 2-1/2" discharges, deck guns and/or aerial waterway

179 FoamPro Options Manual Concentrate Management System * –Controls Tank A and Tank B with manual flush Electronic Concentrate Management system * –Controls Tank A and Tank B with automatic flush MultiFlo Interface * –Digital display of individual water flows, up to 4 discharges Dual Injection Selector * –Allows for two separate injection points Advanced Feature Controller * –Offers “Auto-On” Programming *Not Available on 1600 Series or AccuMax Multi-Point Systems

180 FoamPro Options (cont.) Poly Foam Tanks –5, 12 and 20 gallon Main Waterway Check Valves –1-1/2", 2", 2-1/2", 3", and 4" NPT, BSP, and Victalulic Stainless Steel Manifold –1-1/2", 2", 2-1/2", 3", and 4" Victaulic Solid State Contactor –Offers higher surge protection than solenoids Remote Start/Stop Switch –Allows driver to activate for pump and roll operations System Placards –Schematic and rating

181 AccuMax Multi-Point Options Low Flow Manual Override Pressure Readout at Each Discharge High Pressure Injection (300 PSI) Hydraulic Pump Configurations

Product Lineup Refill Systems

183 Power-Fill Improved Safety –No injuries from climbing on top of vehicles or lifting foam containers Increased Efficiency –Accomplish task faster with fewer personnel Added Economy –Purchase concentrate in larger containers for less cost Two Models –Greater flexibility

184 D.C. Model On-Board System –Pre-plumbed for fast, easy operation Easy To Use –Microprocessor control –Push button activation –Automatic shut-off –Manual override Heavy Duty Pump –Up to 12 GPM –12 volt ½ hp motor –24 volt available –Excellent drafting –Handles all viscosities

185 A.C. Model Portable System –Easily moved to apparatus –Pre-plumbed piping Simple Operation –Full tank indicator –Momentary switch Heavy Duty Pump –Up to 18 GPM –110 volt ½ hp motor –Excellent drafting –GFI protected –Handles all viscosities

186 Some Friendly Advice Define your needs –Immediate –Life of the vehicle Thoroughly check out all of the systems being considered –What the system will and will not do –Check with those who have experience –Consult with more than one reliable source

187 A “Solution” For Every Application