GI/EMME series TRAining CEntre Burner setting. TRAining CEntre Setting sequence: OIL PRESSURE SETTING : Pump and pressure regulator AIR QUANTITY SETTING.

Slides:



Advertisements
Similar presentations
GASFUSE™.
Advertisements

Engineer Training XL1200 Pneumatics. Engineer Training XL1200 Pneumatics Confidential 2 Working Concept Overview: The Pneumatic System is comprised of:
Brio 2000 / Brio 2000-M E-Learning Service Manual Rev. 0.0.
Operating Nitrox Systems 11 Presented by Nuvair. Operating Nitrox Systems2 Membrane systems produce nitrox efficiently Compressed air flows through the.
BUrners TRAining CEntre GAS BURNERS N 900 H/L N 900 H/L series.
© the Design and Technology Association Health and Safety Training Standards in Design and Technology S8HS PLANER/THICKNESSER MACHINE Specialist Extension.
Servicing Welch DRYFAST ULTRA Pump Models 2032
Left Side Discharge Pressure Regulator
Stanley DS11 Diamond Saw.
Assembling a Functional Multi-Wire Proportional Counter - Page 1 Work in pairs. One person will take the chamber apart, and the other will reassemble it.
PRESSURE TEST Hook tester up to tank inlet line. Pump tester up to 10psi (.7 bar) The line and carb should hold pressure for 1-min. Checks for leaks at.
Safety Gas Plus.
Technical support provided by: Highly Pathogenic Avian Influenza Control Programme SOP Use and Maintenance of High Pressure Washer Machine Market chain.
BUrners TRAining CEntre LOW Nox BURNERS B G K series B G K series.
MyLock 644D Service Seminar.
RES G series TRAining CEntre Maintenance. Remove blast tube to check: Correct electrodes position Air nozzle position Fuel nozzle condition.
BUrners TRAining CEntre GULLIVER BLU HYDRAULIC SCHEME.
Clean Air Box Usage & Care CABs RAMs CO Monitors.
Simple Carburettor Fuel System for a Piston Engine
NITRO SHOCK ABSORBERS.
Diesel Engine 4 Stroke Cycle model
1. Pump down the chamber from the atmosphere pressure 2. Using RHEED to obtain diffraction images 3. Open the RHEED chamber or venting from high vacuum.
Actuators.
AccuMax Multi-Point Injection Mechanics
Piston Engine Operations
After Receiving this error code, Follow these steps to correct the problem… Click for next slide.
OZONE DRINKING WATER SYSTEM. CONTENTS Properties of Ozone Production of Ozone Water Treatment Plant – 25 m 3 /hr Ozone Generation System.
SEMINAR ON “GASOLINE DIRECT INJECTION”
Domina PLUS B WORKING DIAGRAMS TROUBLESHOOTING INTERNAL VIEWS WIRING DIAGRAMS INSTALLATION 03 PREVIOUS MODEL.
RES G series TRAining CEntre Burner Settings. General overview Burner is built with our standard components RIELLO’s pump RIELLO’s motor RIELLO’s Control.
HYDRONIC HEATING AQUASTATS
BOILER PLANT OPERATION Presented By Mr. Sivanand Ray
Settings & Adjustments. Settings & Adjustments.
Burners TRAining CEntre. RESIDENTIAL GAS BURNERS R D B R D B series GOALS: KEEP STRONG OUR POSITION ON RESIDENTIAL GAS BURNERS DEDICATED TO OEM’s MARKET.
OIL BURNERS RIELLO 2000 SERIES.
Engineer Training Pneumatic System Overview. Engineer Training Confidential 2 Working Concept Overview: The Pneumatic System is comprised of:  Y Pistons.
MODULATING BURNERS RL/M Series burner operation. UNMB1NL W1W2 B4 B3 AL CH AL1 Q NN N LANDIS LAL 1.25 or LOK 16. III M FR M.
GI/EMME series TRAining CEntre Introduction. TRAining CEntre GI/EMME1400 BASIC identification Family, dual fuel: light oil/natural gasSize: indication.
Flex Cam – Training This shows one version of a complete FlexCam system including Power Unit HCP and Compact Cam CC for piercing operation.
Safety Talk 9 / 1 Safety Talk 9 Safe Operation of Fired Heaters: start-up.
Lesson Using Pneumatic Systems. Interest Approach Can you explain how air makes a pneumatic hand tool work?
BioRad Sputter Coater  Instructions for gold coating a SEM sample.  NO, it’s not your eyes. This image is out of focus.
CONTROL BOX RMG
BURNER TRAINING CENTRE GI/EMME series. BURNER TRAINING CENTRE L1L2L M N ST3 30°ST2 0° ST1 130° MIN STAND-BY MAX OIL FM 123.
PISTON ENGINE PROPULSION Chapter 5 Fuel Systems 1933 Alvis Engine 2014 Hyundai Engine Simple Carburettor Fuel System for a Piston Engine.
Oil Heat Oil Burner Parts.
To complete installation on electronic models run one wash cycle then click the DIP switch setting no.4 to the on position DIP switch settings.
CLM Maintenance. Covers : 1 - Side cover, 2 - Back cover, 3 Top cover, 4 - Lamp door, 5 - Side cover input and communication side, 6 - HEPA dust filter,
World Leaders in Combustion Management Solutions End User Guide Lockout Codes Pressure Sensors Error Codes Flame Safeguard UV.
RL BLU BUrners TRAining CEntre. RL BLU BUrners TRAining CEntre CONTROL BOX LOA B27 FEATURES: #Electrical protection IP 40 #Electrical.
3.1.8 Student Book © 2004 Propane Education & Research CouncilPage Identifying Procedures for Conducting Container Vapor Flaring Operations Before.
Engine Brake VEB + VEB + is the name of the Volvo engine braking system and is a further development of the VEB engine brake. Engine brake VEB + consists.
Diesel Engine Management Systems
AfterSalesTraining Welcome to AfterSalesTraining.
YJQ-W1Q Pneumatic Crimping Tool Instruction GENERAL INFORMATION 1. YJQ-W1Q is widely used for the crimping of wires and contacts in electronic connectors.
COMPRESSED AIR ENGINE (An engine which runs on Air only)
Instructor Click a Section Tab
BUrners TRAining CEntre RS 45/M-160/M BLU INTERMITTENT OPERATION MODE.
Shaft Replacement Standard Operating Procedure
OBJECTIVES Discuss the various methods of loosening the brake bleeder valve. Discuss the need for brake bleeding. Describe the manual bleeding procedure.
UNIT INJECTOR SYSTEM.
Actuators and directional control valves
Modern Valve Timing Introduction
Diesel Engine 4 Stroke Cycle model
COMMON RAIL FUEL INJECTION SYSTEM
MASATS Door Systems.
HYDRAULIC SCHEME PRESS G SERIES.
Presentation transcript:

GI/EMME series TRAining CEntre Burner setting

TRAining CEntre Setting sequence: OIL PRESSURE SETTING : Pump and pressure regulator AIR QUANTITY SETTING : mechanical cam profile NOZZLE SELECTION COMBUSTION HEAD SETTING GAS TRAIN SELECTION GAS QUANTITY SETTING : mechanical cam profile

NOZZLE SELECTION TRAining CEntre

NOZZLE SELECTION Nozzle with needle valve can also be used (in this case you have a light increase of the pressure on the return line). 2) Types with needle valve: BERGONZO type B3 - AA Select the nozzle, with a delivery rating slightly higher than effectively required, Angles of 45° - 50° are normally recommended. For narrow combustion chambers, use nozzles with angles of 30° - 35°. 1) Types without needle valve: BERGONZO type B3 - SA

TRAining CEntre NOZZLE SELECTION

TRAining CEntre NOZZLE SELECTION We need 400 kg/h

GAS TRAIN SELECTION TRAining CEntre

GAS TRAIN SELECTION YOU MUST SELECT THE GAS TRAIN CAREFULLY IN ORDER TO HAVE CORRECT PRESSURE LOSSES Gas pressure at the combustion head Boiler back-pressure + Gas train pressure losses + Gas supply line pressure losses + The sum must be less than the available gas pressure =

TRAining CEntre GAS TRAIN SELECTION Head gas pressure with 0 mbar into the combustion chamber

TRAining CEntre GAS TRAIN SELECTION Gas burner flange Gas butterfly index Max gas pressure switch Head gas pressure point

TRAining CEntre GAS TRAIN SELECTION

COMBUSTION HEAD SETTING TRAining CEntre

COMBUSTION HEAD SETTING Head system positioner Internal shutter Set the head with burner switch off

TRAining CEntre COMBUSTION HEAD SETTING servomotor 1st cam 130° max air open position 2nd cam 0° total close air position (burner stand-by) 3rd cam 20° injection position Servomotor release Servomotor position index

TRAining CEntre COMBUSTION HEAD SETTING output Combustion head stroke - notches 6,5 1

TRAining CEntre COMBUSTION HEAD SETTING Notches scale Index plane 1 notch with servomotor at 0°

TRAining CEntre COMBUSTION HEAD SETTING to set the head at notch 1 with servomotor at 0°, proceed as follows Loosen the two nuts and turn Hexagonal sleeve Until 1 notch is read here

TRAining CEntre COMBUSTION HEAD SETTING 6,5 notches with servomotor at 130°

TRAining CEntre COMBUSTION HEAD SETTING If a shorter stroke is required, then: This shortens the stroke at the max by about 20 mm (about 4 notches) If this is not enough... Loosen the nut and move it up Return with servomotor to 0° position Then re-adjust the sleeve to the minimum position at notch 1 And then come back at 130° to verify the 6,5 notch position If the setting is not yet achieve repete all the procedures again

TRAining CEntre COMBUSTION HEAD SETTING We must set the head eccentric system differently, to reduce eccentricity Loosen the two allen screws And push up the wheel to reduce eccentricity

TRAining CEntre COMBUSTION HEAD SETTING Eccentric cam Combustion head/eccentric system link

TRAining CEntre COMBUSTION HEAD SETTING Summary: If you want change the head stroke, there are 3 different possible settings: 1st - min set position (servomotor at 0°) 2nd - max set position (servomotor at 130°) The burner comes set for the max output and 3rd - max set position (servomotor at 130°)

OIL PRESSURE SETTING Pump and pressure regulator TRAining CEntre

OIL PRESSURE SETTING : TRAining CEntre Pump group Pump motor Pump Oil filter

OIL PRESSURE SETTING : TRAining CEntre Pump Inlet fitting Pressure gauge fitting Delivery fitting Return fitting Vacuum - meter fitting Factory set : 25 bar Pressure regulator

OIL PRESSURE SETTING : TRAining CEntre Valves group Delivery pressure gauge Return pressure gauge Max oil pressure switch From the pump To the pump To the nozzle From the nozzle Pressure absorber

OIL PRESSURE SETTING : TRAining CEntre Oil Safety valve Oil operation valve Oil return valve Pressure regulator

OIL PRESSURE SETTING : TRAining CEntre Pressure regulator Eccentricity adjustment screw Piston calibration nut and locknut Eccentric locking screws Eccentric device

OIL PRESSURE SETTING : TRAining CEntre 8 Min return pressure

OIL PRESSURE SETTING : TRAining CEntre Pressure regulator Burner Start up (servomotor at 20°) Loosen the nat Turn the calibration nat to right or left to achieve the min desire oil return pressure The eccentric system has not influence on the oil pressure

OIL PRESSURE SETTING : TRAining CEntre 17 Max return pressure

OIL PRESSURE SETTING : TRAining CEntre Pressure regulator Burner Max output (servomotor at 130°) Loosen the allen screws With the allen wrench set the eccentricity up to the require return oil pressure. The eccentric cam has the max influence on the oil pressure

AIR QUANTITY SETTING mechanical cam profile TRAining CEntre

AIR QUANTITY SETTING : mechanical cam profile TRAining CEntre servomotor 1st cam: air adjustment 2nd cam: gas adjustment Linkage to air damper

TRAining CEntre Air dampers (toghether connected) Air dampers position index AIR QUANTITY SETTING

TRAining CEntre AIR QUANTITY SETTING Air cam Gas cam Link to the air dampers Adjustment profile screws Profile Lockscrews

We must set the air cam after having set the max and min oil pressure and the combustion head stroke TRAining CEntre AIR QUANTITY SETTING With the burner on, remove voltage from the servomotor, detaching the fast-on pin located on the electrical control panel, and release movement by pressing on release device on the servomotor. Then...

TRAining CEntre AIR QUANTITY SETTING Through the adjustment screws set the correct air quantity, first at the max, after at the min and then in-between positions Remember to create an uniform curve profile of the cam

TRAining CEntre AIR QUANTITY SETTING When the burner is set for a low out-put the air cam profile could be to much close. To avoid this ….. Remove the nat Unscrew the sleeve to obtain a longer linkage Re-set the cam profile to achive the zero air damper position with servomotor at 0°

GAS QUANTITY SETTING mechanical cam profile TRAining CEntre

GAS QUANTITY SETTING TRAining CEntre At the last we must adapt the gas quantity to the air quantity set for the light oil quantity We start to set the burner from the max position with servomotor at 130° and with the gas butterfly completely open notch 90° We must adjust the max gas quantity working on the gas train

GAS QUANTITY SETTING TRAining CEntre filter Pressure regulator valves Set the adjustable screw around 3 of its 5 turns Set the gas pressure up to the gas diagram value required or thruogh the gas analizer set the system up to the correct emissions value

GAS QUANTITY SETTING TRAining CEntre Then through the mechanical cam adjust in-between positions up to the min Gas cam Link to the gas butterfly

GAS QUANTITY SETTING TRAining CEntre Link to the gas butterfly Butterfly position index Burner gas train flange attach Gas butterfly External setting gas device

GAS QUANTITY SETTING TRAining CEntre If after having opened completely the gas profile cam the start gas quantity is not yet enough, it is possible increase it through an external gas setting device. External device index lockscrew Scale: 0 = close 2 = max open

GAS QUANTITY SETTING TRAining CEntre When we open or close this section we increase or reduce the start gas quantity Small gas damper moveable by external device