Food Analysis Lecture 23 (4/19/2005) HPLC (2) and Gas Chromatography (1) Qingrong Huang Department of Food Science Read Material: Chapter 29, page 479.

Slides:



Advertisements
Similar presentations
Gas Chromatography Introduction 1.) Gas Chromatography
Advertisements

Gas Chromatography There an be many parts to a gas chromatography system but the basic components include: An injection system. A column (controllable.
HPLC 1. Introduction 1.Introduction CHROMATOGRAPHY Chromatography basically involves the separation of mixtures due to differences in the distribution.
High Performance Liquid Chromatography. HPLC originally refered to: High Pressure Liquid Chromatography currently refers to: High Precision Liquid Chromatography.
DR ZIAD W JARADAT PROTEIN BIOTECHNOLOGY BT 452 Chapter 3 HIGH PERFORMANCE LIQUID CHROMATOGRAPHY.
Chapter 32 HIGH-PERRORMANCE LIQUID CHROMATOGRAPHY High-performance liquid chromatography (HPLC) is the most versatile and widely used type of elution chromatography.
Standard Methods for the Examination of Water and Wastewater, 21st Ed
Chromatography.
Four basic types of column chromatography where mobile phase is a liquid Partition Chromatography Bonded-Phase Liquid-Liquid Adsorption Chromatography.
High-Performance Liquid Chromatography HPLC, when GC won’t cut it!!!
High Performance Liquid Chromatography. HPLC originally refered to: High Pressure Liquid Chromatography currently refers to: High Precision Liquid Chromatography.
HPLC when GC won’t cut it!!!. Types of HPLC Reverse-phase (water/MeOH-soluble) Normal Phase (very polar) Adsorption (very non-polar) Ion-Exchange (ionic)
Chromatography and Instrumentation. Invented by a Russian Botanist Mikhail Tswett in 1903 He used chromatography to separate the colour pigments in plants.
Pn. Suryati Bt. Syafri 2009 High Performance Liquid Chromatography (HPLC)
CHAPTER 29 Supercritical Fluid Chromatography The mobile phase is a supercritical fluid (a fluid above its critical T and critical pressure) Supercritical.
Effect of Packing Particle Size on Plate Height. Resolution between 2 adjacent peaks.
LECTURE 4: CHROMATOGRAPHY Content: - Chromatographic separation - classifying analytical separations; column chromatography, planar chromatography - gas.
High Performance Liquid Chromatography High Performance Liquid Chromatography Chem. 331.
Analytical Chemistry Section D Separation Techniques.
Gas Chromatography Carrier Gas Flow Control Injector Port Column Column Oven Detector Recorder The GC system consists of gas supplies for the mobile phase.
Chapter 27 Gas Chromatography 1. Principles
1 HPLC HIGH PERFORMANCE LIQUID CHROMATOGRAPHY High Performance Liquid Chromatography (HPLC) is one of the most widely used techniques for identification,
ANALYTICAL CHEMISTRY CHEM 3811 CHAPTER 22 DR. AUGUSTINE OFORI AGYEMAN Assistant professor of chemistry Department of natural sciences Clayton state university.
Chromatography Chapter 6.
Magnet Analytical Chemistry Unit 4
High Performance Liquid Chromatography (HPLC) Jeannette Comeau CHEE April 2004.
1 High Performance Liquid Chromatography (HPLC) Lecture 40.
GC Advantages 1. Very Large N (Very Long Columns) 2. No Packing Material (A=0) 3. Simple Mobile Phase (Compressed Gas) 4. Universal Detectors (FID) 5.
High Performance Liquid Chromatography Instrumentation.
P igh erformance L iquid C hromatography  HPLC is a form of liquid chromatography used to separate compounds that are dissolved in solution. HPLC instruments.
History of Chromatography n Early LC carried out in glass columns n diameters: 1-5 cm n lengths: cm n Size of solid stationary phase n diameters:
Gihan Gawish.Dr High Performance Liquid Chromatography.
High Performance Liquid Chromatography. The chromatogram is a record of detector output Vs time as the analyte passes through the chromatography.
Introduction  High-performance liquid chromatography (HPLC) is a form of liquid chromatography.liquid chromatography  The main purpose is to separate.
Chapter 23 An Introduction to Analytical Separations.
1 Gas Chromatography Lecture Liquid Stationary Phases In general, the polarity of the stationary phase should match that of the sample constituents.
1 HPLC Lecture Displacement pumps Displacement pumps, on the other hand, is composed of a one directional motor driven plunger that pushes the mobile.
Best Broken into four categories
Created with MindGenius Business 2005® Instrumentation (1) Instrumentation (1) Origins Preparative column chromatography (Glass columns) Internal diameter:
Chromatography High Performance Liquid Chromatography HPLC Chapter Dr Gihan Gawish.
HPLC.
High Performance Liquid Chromatography
Ch 21 – Principles of Chromatography and Mass Spectrometry Ch 22 – Gas and Liquid Chromatography.
HPLC.
1 High Performance Liquid Chromatography (HPLC) Lecture 40.
CHROMATOGRAPHY. Chromatography Chromatography basically involves the separation of mixtures due to differences in the distribution coefficient of sample.
Chapter 33 High-Performance Liquid Chromatography.
Ashraf M. Mahmoud, Associate professor CHROMATOGRAPHYCHROMATOGRAPHY.
Introduction to Gas Chromatography
Advantages of LC vs GC Separation of compounds that are soluble in a liquid phase. ie. biological compounds, synthetic or natural polymers and inorganic.
 Laboratory technique for the Separation of mixtures  Chroma -"color" and graphein - "to write”.  Colour bands - separation of individual compounds.
HPLC (High Performance Liquid Chromatography)
Reading assignment: section 26E(p781) Chapter 26 # 2, 3, 14, 15, 16 Chapter 27 # 7(a,d,f), 22, 23, 24, 25.
High Performance Liquid Chromatography Presented by Dr. Kamal Modi 2 nd Year Resident.
High-Performance Liquid Chromatography HPLC, when GC won’t cut it!!!
CHROMATOGRAPHY.
Chromatographic separation
Best Broken into four categories
High Performance Liquid Chromatography
BASICS OF SUPERCRITICAL FLUID CHROMATOGRAPHY
Four basic types of column chromatography
Chromatography Daheeya Alenazi.
High Performance Liquid Chromatography
High Performance Liquid Chromatography (H. P. L. C. ) dr. Sham b
High-Performance Liquid Chromatography
High-Performance Liquid Chromatography
33A-2 Pumping Systems The requirements for liquid chromatographic pumps include the generation of pressures of up to 6000 psi (lb/in2), (2) pulse-free.
GAS CHROMATOGRAPHY.
High performance liquid chromatography (HPLC)
High-Performance Liquid Chromatography
Presentation transcript:

Food Analysis Lecture 23 (4/19/2005) HPLC (2) and Gas Chromatography (1) Qingrong Huang Department of Food Science Read Material: Chapter 29, page 479 Final Exam: April 29

Components of HPLC Pump Injector Column Detector Recorder/integrator/data system

HPLC Pump Requirements Two types of pumps: constant pressure and constant volume; Flow rate ~1 mL/min; Typically stainless steel which can withstand the pressure generated and is resistant to corrosion by oxidizing agents; Sensitive to dust and particulate matter, mobile phase needs to be Filtered. Chemically inert High pressure (5,000 psi) Flow rate ( mL/min) Pulse free or damped Flow reproducibility < 1% Gradient; recycle; rapid change

HPLC Injector Valve injectors (a)Isolated from the pump eluent Stream (LOAD position) (b)Positioned in it (INJECT position)

Solvent Properties Dissolve sample k’ of 1-10 High purity Cost, viscosity, toxicity, boiling point

HPLC Column Typically stainless steel, connected between the injector and detector; Precolumn: auxiliary column that precedes the analytical column; - guard column: used to protect the analytical column from strongly adsorbed sample components; same internal diameter as the analytical column. Analytical column:typically 10, 15, 25 cm long with internal diameter (ID) of 4.6 or 5 mm; - Generally packed with 3, 5 10  m particles, flow rate 1-2 mL/min; - Smaller diameter column is used. - Advantages: (1) decreased consumption of both mobile and stationary phase; (2) decreased peak volume; (3) increased resolution (with long column); (4) reduced equilibration time.

HPLC Column Packing Materials (1)

HPLC Column Packing Materials (2) Microbore: Column with ID mm; Microcolumn: Column with ID <0.5 mm; Functions of packing materials: - In L-L C, only support the stationary; - In adsorption, ion-exchange, and affinity C, serves as support and stationary phase. Requirements of packing materials: - Availability in a well-defined particle size with narrow size distribution; - Sufficient mechanical strength to withstand pressure generated during packing and use; - Good chemical stability.

Types of packing materials (1) Silica-based column packings: particle size and pore distribution - Bonded phase Si OH + Cl Si R  Si O Si R 3 + HCl R1R1 R2R2 R2R2 R1R1 R 1 and R 2 may be halides or methyl groups; the nature of R 3 determines normal-phase, reversed phase, or ion-exchange C; Main disadvantage: silica skeleton slowly dissolves in aqueous solutions. - Pellicular packing materials: deposit a thin layer or coating onto an inert, nonporous, microparticulate core; inorganic core: like Silica; organic core- poly(styrene-divinylbenzene).

Types of packing materials (2) Polymeric column packings: - Synthetic organic resins; - Good chemical stability, possible for chemical modofication. Microporous resins– crosslinked copolymer gel resins, apparent porosity is determined by the degree of crosslinking; swelling and contraction in mobile phases. Macroporous resins – highly crosslinked, consisting of a network of microspheric gel beads joined together to form a large bead; - large, permanent pores from nm in diameter; - Rigid, microparticulate poly(styrene-divinyl benzene) packing materials are popular; - stable from pH 1 to 14.

Detectors Measure concentration Ultraviolet - Fixed wavelength - variable wavelength - Diode array spectrophotometric detector Refractive index Electrochemical detectors UV DetectorRI Detector Good sensitivity – g Universal response Selective Poor sensitivity ~10 -6 g Gradient elution possible No gradients Variable cost Temperature sensitive Most widely used Standard for GPC Used in Prep scale work

Separation Methods Normal Phase HPLC: - Stationary phase: polar adsorbant, such as bare silica or polar nonionic functional group modified silica; - Mobile phase: nonpolar solvent like hexane + CH 3 Cl - Solvent strength: weak solvent increases the retention while strong solvent decreases the retention. - best for separation of compounds that are highly soluble in organic solvents. Reversed Phase: - Stationary phase: nonpolar, typically octadecyl (C 18 ) chain [-(CH 2 ) 17 CH 3 ] or octadecylsilyl (ODS) bonded phase. - Mobile phase: polar solvent, like water mixed with methanol, acetonitrile, or THF.

Gas Chromatography (1) First introduced in 1952, first commercial instrument: 1956; good for thermally stable volatile compounds; Sample preparation: (1) Headspace methods: one of the simplest methods, only good for volatiles in headspace at C>10 -7 g/L; - Direct headspace sampling; - Headspace concentration techniques or purge and trap methods: (2) Distillation methods: (3) Solvent extraction: preferred for the recovery of volatiles from food; use of two immiscible phases (water and an organic solvent) (4) Solid-phase microextraction (SPME): new and rapidly growing

SPME Microextraction technique which employs a thin film of sorptive polymer on a glass fiber Fiber Having varying film thickness of polymer Coatings are based on both absoption and adsorption mechanisms Convenient, solventless extraction technique Used to extract analytes from both liquid and solid matrices

SPME Device

SPME Procedure ExtractionDesorption

Sample Derivatization

Components of GC Gas supply and regulators; Injection port; Oven; Column; Detector; Electronic; Recorder/data handling system.

Diagram of GC System