Introduction Shut Down:2001 Capacity:225 Metric Tons Per Day (100% base) Technology: C & I Girdler Documentation: Available
Detailed Report Utility & Unit Consumption Ammonia ton/ton product (100% base) Power 250 KWH/ton product Boiler feed water 980 lbs/ton product Cooling water 70° F - 85° F cubic meter per ton / (circulation) Steam (credit) export 750 lbs/ton of acid Platinum, net burnt Troy ounce/ton of acid Total catalyst weight 500 Troy ounces/charge. NOx exit extended absorption column Less than 550 PPM
Major Components Equipment Compressor Train Brown Bravery Corporation, Electrical motor driven, Gear box Ammonia Converter 36.5 inches Hex Catalyst support Heat Train Expander Re-heater Air heater W.H. Boiler and the economizer/boiler feed water pre-heater Cooler Condenser Cascade type 4” coil and 432 S.S Absorption Columns Absorption Extended absorption column (NOx column) Added in 1987 and reduced the tail gas making slight changes to the process a NOx level of less than 200 PPM can be achieved.
Major Components Compressor Train Brown Boveri Compressor Design Capacity 28,000 scfm Measured at 60° F and 30” of Hg. Suction Temperature 80° F Humidity 100% Pressure at Delivery Flange 120 psig Power Input at Coupling 5100 KW Operating Speed 5723 RPM
Major Components Three Phase Synchronous Motor Type WR 64 k Works number: B Maximum continuous rating (at power factor 1.0) 4800 kw Speed 1800 rpm Stator Voltage 4160 V Frequency 60 c/s Normal current at continuous rating and power factor 1.0 690 A Efficiency at power factor 1.0 at full load Temperature rise according to ASA-rules: Stator (measured by resistor element) 140° F60° C Rotor (resistance measurement) 176° F80° C Maximum admissible motor temperature 248° F120° C
Major Components Expander Type TA 500/8 Design Capacity (gas composition N 2, O 2, NO 2, H 2 O) 28,000 scfm Measured at 60° F and 30” of Hg. Suction Temperature 80° F Humidity 100% Pressure at Delivery Flange 120 psig Power Input at Coupling 5100 KW Operating Speed 5723 RPM
Major Components Major Spare Parts (partial list) A complete expander Re-heater tube bundle Extra inter stage cooler tubes and ferrules for air compressor Miscellaneous compressor spare bearing parts The expander unit was completely replaced in November 1986 The compressor rotor was completely replaced in 1999 The extended absorption column was added in 1978 The total weight of one4 charge of catalyst was 560 oz. Complete Re-heater tube bundle * A detailed and completed list of all equipment are available and to be provided on demand