The Tomotherapy Experience at Advocate Good Samaritan Hospital

Slides:



Advertisements
Similar presentations
RapidArc in Bergen Britt Nygaard, Harald Valen and Ellen Wasbø
Advertisements

RapidArc plan verification using ArcCHECK™
Awareness - Information - Understanding. What is PEARL? Simply – A Virtual Linac on your desk  communicate Linac machine size and sounds to patients.
In the past few years the usage of conformal and IMRT treatments has been increasing rapidly. These treatments employ the use of tighter margins around.
10th Annual Lung Cancer Conference Radiation Oncology
Copyright ©2008 Accuray, Incorporated. All rights reserved E CyberKnife ® Robotic Radiosurgery System Radiosurgery System Comparisons.
Seeram Chapter 13: Single Slice Spiral - Helical CT
NC HPS Meeting 10/18-19/2001 Boone, NC Recent Advances in CT Technology and Issues of CT Dosimetry T. Yoshizumi 1,2, M. Sarder 1, R. Reiman 1,2, E. Paulson.
Department of Radiation Physics, Royal Derby Hospital
Varian _ Dynamic Targeting TM Image-Guided Radiation Therapy Scott Johnson, PhD Varian Medical Systems Palo Alto, California Varian _.
Para-spinal Tumors Encircling the Spinal Cord IMRT Comparison of Several Target Definitions.
The TrueBeam System ™ Clinic Name Presenter’s name Clinic location
Alamance Regional Cancer Center 2012
Arizona’s First University. Feasibility of Image-Guided SRS for Trigeminal Neuralgia with Novalis.
Real-time tumor tracking with preprogrammed dynamic MLC motion and adaptive dose-rate regulation B.Y Yi, S. Han-Oh, F. Lerma, B. Berman, C. Yu.
Lotte Verbunt Investigation of leaf positioning accuracy of two types of Siemens MLCs making use of an EPID.
Radiotherapy for Brain Tumours What do I need to know? Dr Matthew Foote Radiation Oncologist Princess Alexandra Hospital Queensland.
Saira Ahmad UOG. CAT Scans CAT Scans ( Computerized axial tomography) Topic:
Radiotherapy for Kidney cancer
Radiotherapy Treatment Planning
Results The measured-to-predicted dose ratio criteria used by the RPC to credential institutions is , however for this work, a criteria of
بسم الله الرحمن الرحيم و قل رب زدنى علماً ﴿و قل رب زدنى علماً﴾ صدق الله العظيم.
What Happens in the days before treatment ?
Patient Specific Quality Assurance for IMRT and VMAT based on Radiochromic Film Dosimetry with EBT2/EBT3 Film Sou-Tung Chiu-Tsao, PhD Quality MediPhys.
Evaluation of New Pre-Treatment In-Air Patient Specific QA Software for TomoTherapy Treatments Lydia L. Handsfield¹, Quan Chen¹, Kai Ding¹, Wendel Renner²,
RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY
Quality Control in Radiation Therapy, A New Concept: Dosimetry Check
External Beam Radiation Therapy Special Procedures
Measurement of Dose to Critical Structures Surrounding the Prostate from Intensity-Modulated Radiation Therapy (IMRT) and Three Dimensional Conformal Radiation.
The days before Treatment
Comparison of Rectal Dose Volume Histograms for Definitive Prostate Radiotherapy Among Stereotactic Radiotherapy, IMRT, and 3D-CRT Techniques Author(s):
Patient Plan Results: Table 3 shows the ratio of the Pinnacle TPS calculation to the DPM recalculation for the mean dose from selected regions of interest.
Kelly Younge, Ph.DKelly Younge, Ph.D Don Roberts, Benedick Fraass, Daniel McShan, and Martha Matuszak University of Michigan, Department of Radiation Oncology,University.
Radiation Protection in Radiotherapy
David F. Lewis 1, Andre Micke 1, Xiang Yu 1 and Maria F. Chan 2 1. Advanced Materials Group, Ashland Inc., Wayne, NJ; 2. Department of Medical Physics,
1 4D: Adaptive Radiotherapy & Tomotherapy Bhudatt Paliwal, PhD Professor Departments of Human Oncology & Medical Physics University of Wisconsin Madison.
Surface dose prediction and verification for IMRT plans using line dose profiles † Ronald E. Berg, † Michael S. Gossman and ‡ Stephen J. Klash † Erlanger.
IMRT QA Plan Site 5%/3mm3%/3mm2%/2mm 0% noise1% noise2% noise0% noise1% noise2% noise0% noise1% noise2% noise HN
Medical Accelerator F. Foppiano, M.G. Pia, M. Piergentili
1 A Comprehensive Study on the Heterogeneity Dose Calculation Accuracy in IMRT using an Anthropomorphic Thorax Phantom S Davidson 1, R Popple 2, G Ibbott.
The Answer to Your Dosimetry Needs
Principles and Practice of Radiation Therapy
Somvilai Mayurasakorn, MD. Division of Therapeutic Radiology and Oncology, Faculty of Medicine, Chiang Mai University Somvilai Mayurasakorn, MD. Division.
Introduction to Radiation Therapy
Optimization of Volumetric Modulated Arc Therapy (VMAT) Planning Strategy Using Ring-shaped ROI for Localized Prostate cancer Kentaro Ishii, Masako Hosono,
Saad El Din I, M.D *, Abd El AAl H, M.D *, Makaar W, M.D *, El Beih D, M.Sc †, Hashem W, M.Sc * *Department of Clinical Oncology and Radiotherapy, Kasr.
Reducing excess imaging dose to cancer patients receiving radiotherapy Adam Schwertner, Justin Guan, Xiaofei Ying, Darrin Pelland, Ann Morris, Ryan Flynn.
Dae-Hyun Kim Dept. of Biomedical Engineering The Catholic University of Korea Department of Biomedical Engineering Research Institute.
The Effects of Small Field Dosimetry on the Biological Models Used In Evaluating IMRT Dose Distributions Gene Cardarelli,PhD, MPH.
A virtual simulator in an multivendor radiotherapy department, an overview of the commissioning process Geert Pittomvils, Lobke Mommaerts, Frederic Crop,
Rapid Arc Treatment Verification: post evaluation on Delta-4 and proposal of a new verification protocol G. Pittomvils 1,,L. Paelinck 1, T. Boterberg 1,
E. Mezzenga 1, E. Cagni 1, A. Botti 1, M. Orlandi 1, W.D. Renner 2, M. Iori 1 1. Medical Physics Unit, ASMN-IRCCS of Reggio Emilia, Italy 2. MathResolution.
IAEA International Atomic Energy Agency RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY Part 12.1 : Shielding and X-ray room design Practical.
Computed tomography. Formation of a CT image Data acquisitionImage reconstruction Image display, manipulation Storage, communication And recording.
Treatment Chart Record of patients radiation therapy history. Must contain: History and diagnosis Rationale for treatment Treatment plan Consent Documentation.
Understanding Radiation Therapy Lecturer Radiological Science
CHAPTER 3 DOSE DETERMINATION FOR EXTERNAL BEAMS
Kasey Etreni BSc., MRT(T), RTT, CTIC
Extending intracranial treatment options with Leksell Gamma Knife® Icon™ Key Statements from Customer Perspective by University Medical Centre Mannheim.
CONCLUSION INTRODUCTION RESULTS METHODS AND MATERIALS
Image–Guided Radiation Therapy for Non–small Cell Lung Cancer
Linac Commissioning Overview
Insert tables Insert figure
Volumetric Modulated Arc Therapy (VMAT) versus Intensity Modulated Radiation Therapy (IMRT) for Anal Carcinoma Heather Ortega, BSRT(T), CMD, Kerry Hibbitts,
Resident Physics Lectures
Ch 10. A System of Dosimetric Calculations
Image–Guided Radiation Therapy for Non–small Cell Lung Cancer
Chapter 17 Intensity-Modulated Radiation Therapy
Hot and cold spots are common problems associated with planning:
GHG meeting at ESTRO36 May, 2017
Presentation transcript:

The Tomotherapy Experience at Advocate Good Samaritan Hospital Mark Pankuch

Today’s Discussion The History of Radiation at Good Samaritan Quick Overview of the Tomotherapy Unit Treatment population and Statistics of our experience Results from Shielding Comparison of plans

Advocate Good Samaritan Treated first patient on May 13, 2002 Single Linac Vault with a Seimens Primus Hand me down GE CT scanner from radiology Paper-less / Film-less department

Advocate Good Samaritan Within two years reached capacity for a single Linac department Began offering HDR treatments Strong administrative and physician support for expansion

Advocate Good Samaritan New Vault was needed Doubling current patient volumes appeared as an over estimation for potential volume Present day IGRT with OBI not commonly available

What did Tomotherapy Offer that Good Sam was missing? IGRT “Top End” IMRT

The Answer For Good Sam?

Tomotherapy

Tomotherapy MLC

MLC’s Oriented in the Sagital Plane

The Treatment Process Patient is set up on table to moveable lasers (2 min) High energy CT scan performed in the Tx Position (3 Min) New images are fused with planning CT images (3 Min) Adjustments are made for patient position (2 min) Treatment is delivered (10 Min)

Of Special Note on Hardware: No flattening filter Output ~ 900 MU / min Tx = 10,000 MU MLC’s very, very fast (us) Capable of MVCT export MVCT ~ 2-3 cGy

Planning System Single workstation for planning Cluster of 16 computers, w/ dual processors for computing. Optimizations done on “beamlets” that can be calculated overnight Very few contouring tools, need another system for contouring and fusions No planning review station, system not multitasking

What type of patients have we treated?

Tomotherapy Not optimal for all treatment sites Rotational / Helical Treatments Need the capability to give low doses to large areas of normal tissues Ability of “cave out” doses Very conformal, with good dose drop off

Simultaneous Boost

DQA Tomotherapy Supplied Phantoms Film and Point dose taken on every patient Planning system has built-in QA tools Film analysis evaluated by calculating gamma index (Low et.al., Med Phys 25, 1998) 3% Dose 3mm DTA

QA cGy / MU cGy / min Lasers coincidence Table Accuracy Field Consistency MLC accuracy

Clinical Outcomes Pelvis patients decreased side effects Prostate patients no side effects (78Gy) Brain Patients get ring shape hair loss Head / Neck patients Still have skin reactions Considerably reduces reaction in mouth Need more time for long term results

Skin Reactions

Shielding Considerations Large majority of shielding needed because of leakage Scatter Radiation Primary beam

Shielding Considerations X = W * U * T * ISF Workload: 30 Patients/day 10 min Tx time 880MU/min 66,000,000 MU/year Usage Factors = 1 Occupancy Factor as usual Occupational areas kept to 10% of limits ISF from 3 meters

Shielding Considerations, Leakage Leakage levels obtained from chart like CT scanner Leakage was measured and plotted as a function of position around the gantry and radial distance All leaves closed for measurements Leakage fraction at 3 meters was used ISF from 3 meters

Shielding Considerations, Scatter Scatter levels a function of position around gantry Greatest at opening of couch With all leaves open, can be 186% of leakage exposure Clinically, the exposure can be reduced by a factor of 16 Maximum % scatter increase = 12%, I used 15%

Shielding Considerations, Primary Unit has a built in Primary Beam Block, 13cm Pb The primary beam was 6.3% of the overall radiation at 2.5 cm from the isocenter Clinically, the exposure can be reduced by a factor similar to scatter due to closed leaves I ignored reduction factor, and increased exposure by 6.3%.

Shielding Results North Wall South Wall West Wall East Wall Ceiling Door Calculated Exposure (mR/hr) 0.163 0.042 0.017 0.009 0.058 0.278 Measured Exposure (mR/hr) 0.288 0.012 0.005 0.013 0.188 Ratio of Measured / Calculated 141% 22% 26% 117% 17% 54% Ratio of Measured / Required 58% 12% 5% 3% 38%

Plan Comparison Tomotherapy CMS XIO, Step and Shoot Varian Eclipse, Sliding Window

Which is best?? Depends …….. Many systems now have IGRT Workload Needs Patient sites Many systems now have IGRT Where is IGRT going? No Breath Gateing on Tomotherapy Where is gateing doing?

In the future for Tomotherapy Adaptive treatments Live time optimizations Conductivity with IMPAC Live time QC Breath Coaching Methods

Questions ?? Thanks for your attention! Free tour of the Cancer Center after lunch Questions ???