Electrical Systems.  This section discusses: –How utilities charge for electricity –How to calculate the avoided cost of electricity –How to use utility.

Slides:



Advertisements
Similar presentations
Tariff. The rate at which electrical energy is supplied to a consumer The rate at which electrical energy is supplied to a consumer Therefore tariff naturally.
Advertisements

COST EFFECTIVE SOLUTION TO REDUCING YOUR ENERGY BILL’S POWER MASTER Power Master, LLC, 2040 E. Ridge Rd, Rochester, NY, 14622,
Energy Efficient Motor Drive Systems. Motor Electricity Use  Motors consume about 75% of all the electricity used by industry.  Their popularity is.
The new INOGATE Project Electricity & Gas: AHEF 53.AM John Swinscoe, Michael Emmerton Yerevan, August 2014 BUILDING PARTNERSHIPS FOR ENERGY SECURITY
DTE/ESD Energy Conference and Exhibition Energy Efficiency Implementation Case Study Power Factor Correction Case Study -Power.
Electric Rates and Standby Charges Presented by: Cheryl Eakle – KPPC Jason Volz – Harshaw Trane August 13, 2014.
Energy Savings Through Power Factor Correction
KW Energy Solutions, LLC Increasing Energy Efficiency Increasing Energy Effectiveness.
Electrical Engineering Fundamentals for Non-EEs; © B. Rauf
IMPACTS OF LARGE DISTRIBUTED GENERATORS ON CENTERPOINT ENERGY’S DISTRIBUTION SYSTEM 1 Presented by Ed Briggs, P.E. Manager of Electric Distribution Planning.
Electrical Billing and Rates MAE406 Energy Conservation in Industry Stephen Terry.
Utility Rates Electric, Natural Gas, and Water. Electric Utility Different Utility Business Models – “IOU” – Investor Owned Utility Ultimately responsible.
Power Factor and Power Factor Correction
Power Factor: What Is It and Estimating Its Cost Presented by:Marc Tye, P.E APPA Business & Financial Conference September 21, 2004.
LOGO LINEAR CIRCUIT ANALYSISSAJID HUSSAIN QAZI MEHRAN U.E.T, KHAIRPUR CAMPUS A.C POWERS AND POWER FACTOR.
1 Training Session on Energy Equipment Electricity Presentation from the “Energy Efficiency Guide for Industry in Asia” ©
Plant Utility System (TKK-2210)
CASE STUDY ENERGY CONSERVATION OPPORTUNITIES at A Foundry at Bhiwadi (Rajasthan)
Utility Analysis. Baseline Electricity Analysis  Understanding and documenting current energy use is called developing a baseline. Developing a baseline:
ANALYZING YOUR ELECTRIC BILL Bob Walker Met-Ed November 7, 2007.
RETAIL RATE REVISIONS August 1, 2015 Presented By:
Circuits II EE221 Unit 4 Instructor: Kevin D. Donohue Complex Power, Power Conservation, Power Factor Correction, and Applications.
PowerGUARD Energy Saving for inductive loads Saving 8%-15% Protection Power Quality.
TVA Generates Power and sends it down Transmission Lines to Newport Utilities Distribution Substations TVA Newport Utilities Substations Distributes the.
Utility Savings Bill McGroarty Suburban Electric Supply Co.
POWER FACTOR CORRECTION
Chapter 11 AC Steady-State Power
Energy Audit Best Practices 3rd Annual E Source Major Accounts Training Conference and Summit May 9-11, 2007 Boston, Massachusetts Kelly Kissock Ph.D.
Electrical Energy.  Electrical energy is the energy transferred to an electrical device by moving electrical charges. The energy used at home is measured.
What is Ubiquity™? ubiquity (noun): the state of being, or seeming to be, everywhere at once Ubiquity™ is a powerful building management system that.
Power / Energy Management. Background  USA has 6% of worlds population - Uses 33% of energy consumed  In 1946 we used 30*10 15 BTU  In 1980 we used.
Technical Conference on Net Metering Load Research Study November 5, 2014.
Energy Management System Industrial Controls & Drives (India) Private Limited Chennai
The Importance of Load Factor Reduction and Real-Time Energy Monitoring Harnett County Schools.
Chapter 7 AC Power Analysis
Circuits II EE221 Unit 11 Instructor: Kevin D. Donohue Complex Power, Power Conservation, Power Factor Correction, and Applications.
Circuit Master Circuit Master™ uses three PROVEN technologies* – Capacitor (reduces DEMAND) – Harmonic Filter (harmful frequencies) – Surge Protection.
Capacitor Training Duck River Electric Membership Corp. Doug Simpson.
“Demand Response: Completing the Link Between Wholesale and Retail Pricing” Paul Crumrine Director, Regulatory Strategies & Services Institute for Regulatory.
Rate Design Indiana Industrial Energy Consumers, Inc. (INDIEC) Indiana Industrial Energy Consumers, Inc. (INDIEC) presented by Nick Phillips Brubaker &
The EnergyMizer Power Reduction & Conditioning System ®
Management and Organisation of Electricity Use Electrical System Optimisation Belgrade November 2003.
PFC basics EPCOS Power Quality Solutions. PFC basics FK PC PM PFC – Lukas Motta – Jan PFC Basics Ohmic loads Lighting bulbs Iron Resistive heating.
1 11/17/2015 Power Quality Correction. 2 11/17/2015 Power Quality Correction.
Rocky Mountain Power - Utah Workgroups I and II Load Research and Peak-Hour Forecasting Presented by UTAH INDUSTRIAL ENERGY CONSUMERS Salt Lake City, Utah.
How to help improve energy management without a dedicated energy manager Simple Energy Management through Utility Bills 17 th November 2015.
Talha Mehmood Chapter # 5 TARIFF. Introduction The electrical energy produced by a power station is delivered to a large number of consumers. The supply.
Presented by. What is Power Factor? Power Factor is the percentage of current delivered from the utility that is needed to perform the actual work. For.
FUNDAMENTAL OF ELECTRICAL POWER SYSTEMS (EE 270)
Program Overview Solar resource will be built by j uwi, (pronounced “you-vee”), a developer based out of Boulder, Colorado. Solar farm will be located.
2015 ElectriCities Advanced Meter School. Rate Design Goals The two primary goals of rate design are to (a)provide rates that lead to utility revenues.
Customer Concerns with Implementing Demand Rates NASUCA and NARUC Conferences Austin, Texas November 2015 David Springe Consumer Counsel Kansas Citizens’
By Fluke India.
Advanced Meter School August 18-20,2015 Time of Use and Load Profile Jeremiah Swann.
Lesson 3: Ac Power in Single Phase Circuits
Power Generation and Distribution
Power Factor Correction The Definitive power solution
Power Factor Correction The Definitive power solution
POWER FACTOR CORRECTION
Leveraging Energy Infrastructure to Drive Revenue
Houston Power Services Company
Making Cents of Energy Understanding Utility Rates
Why does power factor matter Make-up of distribution capacitor banks
Sr. Lecturer in Electrical Engg. Govt. Polytechnic,Manesar
Reducing Electrical Energy Consumption
What you Pay to Utilities?
Mike Mumper & Brian Kick Good afternoon
Fleet Electrification
Energy Management PPKSE 06/07 SAA.
Cost of Electricity & Energy Usage Energy Use Recall: Measured in Watts (W) Electrical power is the rate at which electrical energy is produced.
Presentation transcript:

Electrical Systems

 This section discusses: –How utilities charge for electricity –How to calculate the avoided cost of electricity –How to use utility billing analysis to help identify cost saving opportunities

Electric Rate Structures  Total cost of electricity in most rate structures is the sum of: –Service charge –Energy charge –Demand charge –Power factor charge

Energy Charge  Based on total energy (kWh) consumed over entire month  Charge typically uses block structure with decreasing unit cost for larger amounts –Fixed Blocks $0.05 /kWh for the first 10,000 kWh $0.04 /kWh for the next 100,000 kWh $0.03 /kW for all remaining kWh –Demand-dependent Blocks $0.05 /kWh for first 250 kWh/kW $0.04 /kWh for next 150 kWh/kW $0.03 /kWh for all additional kWh  Fuel Cost Adjustments and Taxes: –Because the cost of fuel for a utility may vary over time, utilities sometimes modify the energy costs in the rate schedule with a “fuel cost adjustment”.

Demand Charge  In addition to measuring total energy consumed over entire period, also measuring energy consumed over every 15 or 30-minute period during month. Find period with max energy use, convert to rate (kW), and charge monthly fee.  Demand charge may use block structure with decreasing unit cost for larger amounts –$15.00 /kW for the first 100 kWh –$12.00 /kW for all remaining kW  On Peak - Off Peak Rates: –‘billing demand’ is calculated as the greater of: –the actual on-peak demand, or –50% of the actual off-peak demand.  Seasonal Demand Charge: –the actual demand, or –75% of the peak monthly demand during the previous 12 months.

Power Factor Charge  In inductive loads (i.e. motors), voltage lags current making some power unusable: reactive power (kVAr)  Supplied power (kVA) must compensate for reactive (kVAr) and usable (kW) power.  Power factor is ratio of usable power (kW) to supplied power (kVA)  Most utilities charge for low power factor since supplied power (kVA) > useable power (kW)

Example Rate Structure 1  Service: –$95 /month  Energy: –$0.021 /kWh  Demand: –$13.86 /kW-month –Greatest average power during any 30-minute period –Greatest of: –100% of on-peak (weekdays: 8 am to 8 pm) –75% of off-peak (all other times) –75% of max Jun, Jul, Aug, Dec, Jan, Feb in last 11 months  Power Factor: –$0.30 /kVAr-month

Example Rate Structure 2  Service:$100 /mo  Energy:$0.026 /kWh for first 250 kWh/kVA  $0.011 /kWh for all additional kWh  Demand: $18.36 /kVA-mo for first 4,000 kVA:  $14.45 /kVA-mo for all additional kVA  Greatest average power during any 15-minute period  Power factor:Implicit in kVA

Electrical Cost Breakdown

Interpreting Electricity Billing Data

Use graphical analysis!

Electrical System Cost Saving Opportunities  Billing Errors –Reconcile billing error with utility  Meter Consolidation –Consolidate electrical meters  Purchasing Transformer –Purchase transformer and switch to primary service  Power Factor Correction –Correct power factor by downsizing over-sized motors –Correct power factor by adding capacitors  Demand Saving Potential –Reschedule operation of electrical equipment to reduce peak demand. –Use control equipment to shed loads to manage peak demand  Demand Response Program –Voluntarily reduce demand during demand emergency

Verify Billing Amounts

Meter Consolidation 2 Meters: ED = = 130 kW 1 Meter: ED = 100 kW

Purchase Transformer And Switch To Primary Service  Primary Service: customer owns and maintains the transformer  Secondary Service: utility owns and maintains the transformer  Lower electricity rates for primary service, since the customer must purchase and maintain the transformer.  Advantageous for customer to purchase transformer when demand > 1,000 kVA.

Correct Power Factor  Low PF has three adverse effects: –Utilities charge for low PF –Increased supplied power (kVA) increases line losses, line size, transformer size –May cause sensitive electrical equipment to malfunction.  Good practice to maintain PF > 90% by –Right-sizing under-loaded motors –Adding capacitors that absorb kVAr, decrease kVA and increase PF

Demand Saving Potential Low potential for 1-shift and 3-balanced shift operations

Demand Saving Potential Good potential for uneven shifts

Demand Saving Potential 20 kW potential limited by first shift demand to 10 kW

Demand Saving Potential Savings larger with “off-peak demand rates”: Savings = 500 kW for moving demand from 1 st to 2 nd shift Savings = 1,000 kW for moving demand from 1 st to 3 nd shift

Stagger Startup of Barrel Heaters Sunday barrel pre-heat would set peak if hydraulic motors on during startup.

Demand Response Programs  Many utilities and independent companies offer demand response programs  Demand response compensates customers for having ability and willingness to curtail load during critical times on the grid.  Demand response payments ~ $50 /kW-year.  No “demand emergencies” in 13-state PJM territory in last two years.  Example: agree to reduce demand by 100 kW and receive ~ $5,000 per year.