SMASH 2008 Recap: Introducing Citation, Your Hard- Working Lab Assistant Dean Olson, Ph.D. Director of Customer Support Protasis Corporation.

Slides:



Advertisements
Similar presentations
Bioinformatics for Metabolomics and Fluxomics E’ ? ? ? ? ? ? A?C? E ABCD E v1v1 v2v2 v3v3 v4v4 v5v5 v6v6 v7v7 ABCD E RL 1; metabolite identification RL.
Advertisements

1 E-Seminar Protocols Press *6 to mute (listen) Press #6 to un-mute (ask a question) As a courtesy to others, please mute your phone line while listening.
© Pfizer Limited Cap and CASE: a step forward towards automatic structure elucidation Anna Codina, Ruth Boetzel, Ingrid Hamernig and Don Richards.
LC-MS Plus NMR Building And Confirming Modern Molecular Libraries Bob Albrecht Protasis Corporation.
Protein Quantitation II: Multiple Reaction Monitoring
From Genome to Proteome Juang RH (2004) BCbasics Systems Biology, Integrated Biology.
Improvements in Mass Spectrometry for Life Science Research – Does Agilent Have the Answer? Ashley Sage PhD.
Microliter-Volume NMR The Wellplate and Microvial as an Efficient Medium of Sample Transport Among Automated Methods of Analysis.
1 One-Minute NMR Adding Integrated Data Processing to Open-Access, High-Throughput NMR Automation Easy Fast Efficient Economical Controllable Flexible.
Rapid, Small-scale Dereplication of Bioactive Extracts John Blunt University of Canterbury New Zealand 1.
Routine Analysis of Five-Microliter Samples using an automated microflow NMR system Bernhard H. Geierstanger, Ph.D. Protein Sciences Department Genomics.
Bioinformatic Treatment of Human Metabolome Profile for Diagnostics Dr. Petr Lokhov & Dr. Alexander Archakov Institute of Biomedical Chemistry, RAMS.
on Metabolomics Bioinformatics for Life Scientists
Analysing the METABOLOME 1.Metabolite Extraction 2.Metabolite Separation 3.Metabolite detection (with or without separation) 4.Data analysis.
Detecting Melamine in the Food Supply Michael Parks CHEM 4101, Fall /04/09.
Microbial Profiling Facility - MPF Center for Microbial Biotechnology (CMB) Kristian Fog Nielsen Associate professor, Ph.D, Center for Microbial Biotechnology.
LC/MS WORKSHOP IOWA STATE UNIVERSITY Kamel Harrata  Instrument Description  Data Acquisition  Data Processing.
Previous Lecture: Regression and Correlation
Instant Notes Analytical Chemistry
FIGURE 5. Plot of peptide charge state ratios. Quality Control Concept Figure 6 shows a concept for the implementation of quality control as system suitability.
Proteomics Josh Leung Biology 1220 April 13 th, 2010.
1- Building up and maintaining a high-quality natural product library
1 One-Minute NMR: Precious Samples using HPLC and Capillary NMR Natural Products Analysis The Easy Way with Microplate NMR Automation Easy Fast Efficient.
Tryptic digestion Proteomics Workflow for Gel-based and LC-coupled Mass Spectrometry Protein or peptide pre-fractionation is a prerequisite for the reduction.
Building High Throughput Natural Products Libraries
Metabolomics 5/2/2014. ‘Omics Family Tree W. M. Claudino, et al., Journal of Clinical Oncology, 2007, 25(19), pp /2/2014.
Gas chromatography coupled to mass spectrometry Liquid chromatography coupled to mass spectrometry MetMAX – Data alignment COVAIN – Data integration, Statistics.
Quality-Assurance for the NMR Data Consumer Integrating NMR into Modern Laboratory Workflow Robert W. Albrecht Craig Milling PhD Dean Olson PhD Protasis.
Copyright © 2008 by Protasis Corporation, All Rights Reserved
Workflow Diagram for the Natural Product/Metabolite/Discovery Chemist LC vacuum centrifuge MS DAD/ELSD or bioactivity NMR Purification Fraction Collection.
2007 GeneSpring MS GeneSpring for Metabolite BioMarker Analysis using Mass Spectrometry data Agilent Q-TOF VIP Visit Jan 16-17, 2007 Santa Clara, CA Thon.
Mass spectrometry session. Summary Fiehn (1) Standardization important Reporting important, but has to be feasible Does not matter which MS instrument.
Sample Preparation Strategies for Routine Trace Mixture Analysis by NMR David Detlefsen, Kenneth Ray & Jeffrey Whitney.
Supplement 1 PCA analysis of metabolite data from untreated rice genotypes by LC-TOF and GC-TOF mass spectrometry. Top panel: (A) LC-TOF analysis of Xa21.
Sales Objections and FAQ’s 940-LC Analytical to Preparative Systems.
Chapter 15 New Technologies and Automation ©2002 Academic Press.
Untargeted Metabolomics: Tandem LC-MSMS. Column and Flow Rate Selection Insert Barnes table for flow rates and sensitivity gain. Reverse Phase and Normal.
Mike Rusak and Laura Fairburn CURRENT OBSTACLES ON THE APPLICATION OF AMBIENT IONIZATION MS IN FORENSICS.
Fall Conference Recap: Introducing Citation Push Button Sample Injector Dean Olson, Ph.D. Director, Customer Support.
High throughput Protein Measurement Techniques Harin Kanani.
Combining and Choosing Analytical Techniques Chapter 8.
An Ultrasensitive LC-MS+NMR Platform Utilizing Segmented-Flow Microcoil NMR, Nanospray ESI, and 4 mm LC Columns Yiqing Lin, Paul Vouros, Jimmy Orjala 1,
1 E-Seminar Protocols Press *6 to mute (listen) Press #6 to un-mute (ask a question) As a courtesy to others, please mute your phone line while listening.
LCMS-325 TQ Operation Chem 115 Paul Hrvatin Winter 2013.
Proteomics Informatics (BMSC-GA 4437) Instructor David Fenyö Contact information
Salamanca, March 16th 2010 Participants: Laboratori de Proteomica-HUVH Servicio de Proteómica-CNB-CSIC Participants: Laboratori de Proteomica-HUVH Servicio.
Metabolomics MS and Data Analysis PCB 5530 Tom Niehaus Fall 2015.
Chem. 133 – 4/26 Lecture. Announcements Return graded quiz and additional problem Lab – Lab report deadlines (2:4 – Thursday) Today’s Lecture – Mass Spectrometry.
Toxicological Screening of 80 Drugs in Urine Using the High Resolution Exactive LC/MS Orbitrap Mass Spectrometer Coupled to Online Extraction and Turbulent.
What is proteomics? Richard Mbasu and Ben Richards.
Computational Challenges in Metabolomics (Part 1)
Data independent acquisition methods for metabolomics Stephen Tate, Ron Bonner AB SCIEX, 71 Four Valley Drive, Concord, ON, L4K 4V8 Canada A high resolution.
Target Analyses in Parallel Reaction Monitoring Mode (PRM)
Metabolomics Data Analysis
Accelerating Research in Life Sciences
Agenda Welcome from the Skyline team!
Automation of Sample Preparation for Trace Analysis Haibin Wan
Systems Medicine Automated Real-Time Quality Control of LC-MS Metabolomics Data: QC4Metabolomics stanstrup.github.io.
Bioinformatics Solutions Inc.
Metabolomics: Preanalytical Variables
Discrimination and Quantification of True Biological Signals in Metabolomics Analysis Based on Liquid Chromatography-Mass Spectrometry  Lixin Duan, István.
EQS 17β-estradiol 17a-ethinyl-estradiol 0.4 ng/L 35 pg/L
Relative quantitation of phosphopeptides from conditioned media from subtype specific breast cancer cell lines. Relative quantitation of phosphopeptides.
Chromatograms, MS and MS/MS spectra obtained by LC-MS/MS (Q-TOF) of peptides from UPIII identified after Western blotting followed by on-membrane digestion.
Investice do rozvoje vzdělávání
Microbiome: Metabolomics
General schematic for MS analysis of ionized microbiological isolates and clinical material. General schematic for MS analysis of ionized microbiological.
General schematic for the identification of bacteria and yeast by MALDI-TOF MS using the intact-cell method. General schematic for the identification of.
Mass spectrometry (MS) is an analytical technique that can be used to determine the mass, elemental composition or chemical structure of molecules. Mass.
Presentation transcript:

SMASH 2008 Recap: Introducing Citation, Your Hard- Working Lab Assistant Dean Olson, Ph.D. Director of Customer Support Protasis Corporation

Citation: Push-Button Sample Loader Chromatography-grade Fluidics Easy-to-use, Web-based Software Built-in Instrument Controller Integral Degassing Field-serviceable Valves Small-footprint benchtop packaging Enjoy the reassurance of feedback control, auto-calibration, and system self-maintenance in applications where the robot is not required Completely upgradeable to full robotic automation

Chromatography grade pumps Field-serviceable valves Integrated feedback control sensors Degas, blanket, sparge On-board instrument controller Protasis One-Minute™ NMR Lite Software

The size of a plant metabolome is unknown it is estimated at a few thousand constituents Plant metabolomics LC-NMR mol LC-UV10 -9 mol GC-MS mol LC-MS mol LC-LIF mol CE-LIF mol Sumner et al. Phytochemistry 2003, 62, Rapid, Reproducible and Non-Destructive Low Sensitivity NMR Metabolomics High Sensitivity Instrumentation variability LC-MS: problem in RT repeatability MS Metabolomics

CONTROL WOUNDED PCA of total crude extract MS spectra spiked Total crude extract TOF MS spectra RANKED LIST OF INDUCED IONS Total crude extract TOF MS spectra CONTROL WOUNDED C 12 H 17 O Data Courtesty of Jean-Luc Wolfender, University of Geneva, Switzerland

UPLC-TOF-ES-MS of A. thaliana Induced by wounding m/z (+/- 10 ppm) m/z (+/- 0.5 Da) CAP-NMR Multiple collection triggered by MS Data Courtesty of Jean-Luc Wolfender, University of Geneva, Switzerland

CAP-NMR of ion m/z 209 CAP-NMR ca 1  g NT= ,2,811,5412 Standard 50  g Data Courtesty of Jean-Luc Wolfender, University of Geneva, Switzerland

Further example details can be found in… A LC-MS approach is presented for the isolation of minor key plant biomarkers, in view of their characterization by NMR at the microgram scale …using ultra-performance liquid chromatography- time-of-flight mass spectrometry (UPLC-TOF-MS) … then transferred to semi-preparative LC conditions with MS detection … and subsequent characterization by capillary NMR (CapNMR).

Hot Off the Press: Natural Products Workflow Herein we present a method of extract evaluation using HPLC profiling with biological evaluation 16 followed by capillary probe NMR spectroscopy/ESMS/UV combined with NMR database (AntiMarin) evaluation, which reduces the crude extract requirement for dereplication to submilligram quantities. 17

Full Robotic Automation Automated Push-Button Discrete Sample Loading vs. You pick