DR-2000 Customer Benefits Security; Tamper resistant programming protects your customer and you! Low maintenance, long battery life & long squeeze tube.

Slides:



Advertisements
Similar presentations
Instructional Presentation
Advertisements

The drill press is the preferred tool for making holes in materials.
From the Box to Packing in 30 minutes Pack-in-a-Box components Remove components and assemble bracket as shown Follow the instructions to pack your first.
Selling Inoculants Module One – How are your Cows?
Sectional Assembly and Installation
CHAPTER 45 Engine Lubrication.
NORTH POWERED AIR-PURIFYING RESPITATOR (PAPR) INSTRUCTIONS FOR USE Preventive Medicine Industrial Hygiene Service.
Brio 2000 / Brio 2000-M E-Learning Service Manual Rev. 0.0.
Kenmore Front Load Washer & Dryer
HVAC523 Soldering.
LogTag Training January 2015
Optical Manufacturing Solutions 1 Probe Assembly.
Metering Pump Spare Parts Replacement. Pump Components (Metering Pump) Pumps are supplied with a 120VAC or 240VAC power cord. Use care to ensure pump.
A-dec 300 Dual Mount on 500 Installation. Agenda ► General Information ► Recommended tools ► Installation ► Follow through install guide ► Hands-on install.
Installation. Indoor Unit Installation Typical Installation.
Click on this image to open the full PDF document.
How to carry out experiments using MPMS March 2012 Takeshi NAKAGAWA.
Fluid Power Hydraulic Cylinders
TLA. Replacing The Battery On the Back of the pager press in this button while moving the door away from the pager, then lift up. On the Back of the pager.
① The output signal of a room thermostat is ON or OFF according to changes of room temperature ② The power supply to a motorized valve is ON or OFF according.
Yamaha oil pump rebuild
1 Check all equipment is included before returning. If you have an accident or the equipment is damaged or you need support please contact Blaize
Strut Jack Operation The TeleCrib® Strut Jack is a removable 8,000 lb jack which fits over the strut body and gives the rescuer a controlled means for.
Familiarization and Operation
Clean Air Box Usage & Care CABs RAMs CO Monitors.
Applied Control Systems
Power-Fill Operation Demonstration Power-Fill Operation Demonstration (See Installation and Operation Manual for detailed instructions)
Condensation Piping and Installation Drain Pans
Tank and Inline Chiller Setup. Equipment list  Bleach  Aquarium (min 10 Gal)  Chiller (there are several types)  Insulated box or some kind of tank.
Powered Air-Purifying PARTICLE Respirator (PAPR) Copyright © 2013 by The S.E.A. Group.
Unit 205: Cold water systems
Powered Air-Purifying Respirator (PAPR) Copyright © 2015 by The S.E.A. Group.
Installation. Indoor Unit Installation Typical Installation.
Step 1 Park vehicle on a level surface then engage the parking brake and turn off engine. If you cannot comfortably get under the car, raise the front.
AccuMax Multi-Point Injection Mechanics
Usage Guidelines Throughout this template you will find tip-boxes to the left of the slides. To remove this box from the final presentation, simply click.
SpectraSonde Assembly. What is the SpectraSonde? Reads temperature, pressure, and humidity data from the atmosphere. The SpectraSonde doesn’t fly like.
Hydraulics For The Long Term
Series Operational Training. 2 Water Tank Water Pump Multiple Discharges 2000 Series Line Strainer Foam Tank Electronic Direct Injection Proportioner.
Cypress-Fairbanks I.S.D. 04/04/05 PC6 Word Processor Training Assistive Technology
Outcome 3 (part 2) Heat emitters and their components Unit 208: Central heating systems.
HYDRAULICS & PNEUMATICS
Installation. Indoor Unit Installation Typical Installation.
GCS 300 System Operation Application – Level 1.
INSTALLATION & COMMISSIONING. 5WSS Installation Hanging the Unit Hanging the Unit Location Considerations Location Considerations Refrigerant Piping Refrigerant.
SIP POU cooler Installation Guide. Getting Started The SIP 2000 can be easily installed in most POU coolers in just a few minutes. The tools needed are.
Recyclable Replacement Service Pack Contents Batteries Grease pouch prefilled Waterproof cover Technolube Electromechanical Refillable Lubricators * *
AJ5808/5808A INFUSION PUMP QUICK OPERATION GUIDE.
To complete installation on electronic models run one wash cycle then click the DIP switch setting no.4 to the on position DIP switch settings.
Manual Density Business Today
Shortwave Diathermy Clinical Application. Treatment Dosages Pulse DoseSensationWidthRate (pps) NTNo warmth65 µsec100 – 200 1Mild warmth100 µsec800 2Moderate.
STEP 1 Locate the transmission cooler line connection on the vehicle. Identify the correct adapters to be used by referring to the vehicle application.
NN-CS596S Steam Microwave Oven. NN-CS596S Oven Specification.
Using a Digital Data Logger North Carolina Immunization Program (NCIP)
Build A Motor You must follow the directions step-by-step!
VIEW SERIES with Sliding Door
Quick Start Guide for Flex Flow Pump
Easy centering and setting system
Meeting In A Box Set Up Guide
Student CD for Commercial Refrigeration for A/C Technicians Chapter 12 Ice Machines.
Fuel Supply System Service
CHAPTER 45 Engine Lubrication.
G450 and G460 battery pack maintenance
Millennium touch screen Operated Profiler Series Roaster control
“Lesson – Installing Material Cartridge and Printing a File”
Fin & Countertop Sample Kit Instructions
Beginner Stander Presentation
Presentation transcript:

DR-2000 Customer Benefits Security; Tamper resistant programming protects your customer and you! Low maintenance, long battery life & long squeeze tube life; fewer service calls! Compact, Plastic, Water Resistant housing; fits in small spaces and won’t be damaged by splash or humidity. Flexible dosing; can be used to fill a variety of different needs including misting applications. Battery powered option; allows you to install even when line power is not available. Impossible to accidentally leave in program mode; eliminates mistakes! Cost Effective; even in small accounts!

What’s in the box! DR-2000 Components Battery and Line power DR-2000 pumps come with an install kit and the Installation and Operation Manual.

Changing the Batteries Installation and Set-Up Remove the 4 screws on the battery side cover, remove the cover and insert 4 D-Cell batteries into the battery holder aligning the batteries as indicated. Note: The DR-2000 can be program using only the back up battery. Clock settings and events will be retained, but events will only occur if a primary power source is connected.

Using the Mounting Bracket Installation and Set-Up The DR-2000 comes with a mounting bracket taped to the back. Use the screws in the installation kit, and a level if necessary to mount the mounting bracket. 115 VAC Mounting Bracket Battery Pack Mounting Bracket 115 VAC Mounting Bracket

Hanging the DR-2000 Installation and Set-Up Slide the DR-2000 down over the mounting bracket. If desired a screw can be put in one of the feet to secure the DR-2000 in place. The DR-2000 can also be mounted using only the 3 mounting feet. Care should be taken not to put undue pressure on the feet and cracking them. Troubles can be avoided by always mounting horizontally on a smooth surface.

Chemical uptake line connections Installation and Set-up The installation kit (part # ) comes with 25 feet of transport tubing, a metal injection fitting, a 2-part stand pipe screws and tie wraps. Cut the desired length of tubing for the chemical uptake line. Connect one end to the uptake side for the SnapHead pump (the left side).

Chemical uptake line connections Installation and Set-up The white plastic line protector is used to prevent bends and kinks in the uptake line. The stand pipe couple is used to connect the two portions of stand pipe if necessary (added to install kit Fall 2003). The uptake line entrance should be cut at a 45 o angle and snapped into place 1/2 inch above the end of the stand pipe. Attach the white plastic line protector over the uptake line on the pump side of the stand pipe. Use the stand pipe couple to unite the two pieces of stand pipe if desired.

Chemical uptake line connections Installation and Set-up Insert the stand pipe into the chemical drum. The stand pipe serves to keep the uptake line rigid so that chemical is drawn from the bottom of the drum. The 45 o angle in the uptake entrance as well as the 1/2 inch space serves to prevent the uptake line from forming a seal with the bottom or sides of the chemical drum, and assuring unobstructed chemical flow.

Chemical delivery line connections Installation and Set-up Cut the desired length of chemical deliver tube. Connect one end to the delivery side of the SnapHead cartridge (the right side). Run the tube to the point where the chemical is to be delivered. Tie wraps can be used to hold the tube in place. A metal injection fitting is provided and can be screwed into a threaded 1/4 inch hole tapped into the drain pipe if desired.

Entering Program Mode DR-2000 Programming Press the Program button and hold it down for 8 seconds. The screen will flash and the colon will stop blinking to indicate that you have successfully entered Program Mode. Release the program button. The screen will continue to display the current day and time.

Setting the Clock / the time of day DR-2000 Programming Use the HOURS and MINUTES buttons to set the clock. A “P” will appear to indicate PM settings. Set the current time of day. The above screen indicates the time is 4:15 PM on day 7 (Sunday).

Setting the Clock / the day of the week DR-2000 Programming From this screen you can also set the day of the week. To do so press the DAY button until the current day appears (day 1 to 7). It is suggested that you set day 1 as Monday. The above screen indicates the time is 6:45 AM on Day 1 (Monday).

Programming when an event will occur / time DR-2000 Programming Press the EVENT button once, the screen will display E:01 to indicate you are entering Event 1. There are 24 such events. Press the Event button again, the screen will display the time of day and day (s) of the week the event is programmed to occur. Use the HOURS and MINUTES buttons to set the time you want the event to start.

Programming when an event will occur / day DR-2000 Programming While programming when an event will occur you have the option to differentiate between days of the week. Use the DAY button to select which days of the week, or combination of days you want the the event to occur. Day dosing options: One day a week (selected individually 1-7) Every Day (1-7 appear together) Only Weekdays (1-5 appear together) Only Weekend days (6 & 7 appear together) The above screen indicates an event will occur at 7:30 PM day s 1-5 (Monday-Friday) The above screen indicates an event will occur at 7:30 PM day 1 (Monday) The above screen indicates an event will occur at 7:30 PM days 1-7 (everyday) The above screen indicates an event will occur at 7:30 PM days 6-7 (weekends)

Programming the duration of an event DR-2000 Programming After programming dosing time of day press the EVENT button again. The screen will display the duration of the event and MIN:SEC will appear. Use the MINUTES and SECONDS buttons to program the duration of the event. The minimum event duration is 1 second and the maximum event duration is 19 minutes and 59 seconds. Programming an event of zero seconds will assure that no event occurs. The Screen above indicates the event will have a duration of 2 minutes and 20 seconds

Programming the duration of an event / tips DR-2000 Programming As batteries age the DR-2000 will spin slower and deliver less chemical in any give time period. A set of Procell batteries will deliver about 50 L (Two 5 gallon pails) of chemical. It is recommended that you allow at least 20 minutes intervals between events. The 115 VAC line powered unit will deliver about 120 mls per minute with Viton squeeze tube. The Battery powered unit will deliver about 110 mls per minute with new batteries and Viton squeeze tube. Delivery rate will vary with the age of the squeeze tube, the viscosity of the chemical being pumped, the distance of the run and the ambient temperature.

Erasing unwanted Events DR-2000 Programming To avoid the occurrence of unwanted events it is advisable to be sure that all unused events are erased. To do this DR-2000 has a built in easy-erase feature. To use the erase feature begin on the Event Screen of the first event you wish to erase. Press and hold the HOURS and MINUTES buttons and then press the EVENT button. The DR-2000 will scroll through all higher numbered events setting each run time to 0:00. The process will stop when it reaches the Event 1 screen.

Leaving Program Mode DR-2000 Programming When you have finished programming the DR-2000 you can leave Program Mode and return to Run Mode by pressing the Program button once. When in Run Mode the colon blinks once per second and the PRIME button primes the pump. If the DR-2000 is left unattended for 2 1/2 minutes it will automatically return to Run Mode.

What do I do if…? DR-2000 Troubleshooting The pump runs backwards? –Switch the on the motor. The screen has no display? –Change the coin cell backup battery on the main PCB and check the power source. Events do not occur? –Check the power source (batteries or plug). –Check that the events are properly programmed. The DR-2000 does not deliver the amount of chemical expected? –Deliver rates can vary, check the flow rate and adjust the length of the event accordingly.

What do I do if…? DR-2000 Troubleshooting Pump spins but chemical does not move? –Check the uptake line for kinks or blockage. –Check that the uptake like is properly attached to the pump. The clock resets and events are lost when the electricity goes out? –Change the coin cell backup battery on the main PCB. For more troubleshooting tips see the Troubleshooting section of the Installation and Operation Manual of your DR-2000 Chemical Pump.