Compact & Perfect for Your Satisfaction

Slides:



Advertisements
Similar presentations
1 The YL9100S HPLC All your needs for semi-preparative applications.
Advertisements

Teledyne Analytical Instruments
Think Smart Work Better
Static Transfer Switch
Nanodrop 2000c. Who is NanoDrop? Manufacture and Cell analytical laboratory equipment worldwide Used in biotechnology, pharmaceutical, and life science.
HPLC 1. Introduction 1.Introduction CHROMATOGRAPHY Chromatography basically involves the separation of mixtures due to differences in the distribution.
UV-vis. Applications Quantitative analysis Organics (if composition is simple and known) Specific binding to chromaphore Metal-ligand absorption (d-orbital.
Lecture 9 Yuri Kazakevich Seton Hall University
High Performance Liquid Chromatography. HPLC originally refered to: High Pressure Liquid Chromatography currently refers to: High Precision Liquid Chromatography.
Figure 1. Influence of sample solvent on peak shape. The sample is dissolved in buffer with (a) 0%, (b) 30%, (c) 50%, and (d) 70% acetonitrile. Sample.
HPLC Systems. Column Chromatography HPLC Modes HPLC – System Components.
High Performance Liquid Chromatography. HPLC originally refered to: High Pressure Liquid Chromatography currently refers to: High Precision Liquid Chromatography.
Lecture 21 HPLC-2 Instrumentation. Column Injector Detector Chromatograph Data Processing.
CHAPTER 29 Supercritical Fluid Chromatography The mobile phase is a supercritical fluid (a fluid above its critical T and critical pressure) Supercritical.
High Performance Liquid Chromatography
By: Thilag.k & Stephen. What is Hpcl??? Hplc or high performance liquid chromatography is the most widely used analytical separation technique. The difference.
Method conditions Excellent resolution and fast run times 2 x OligoPore, 4.6 x 250 mm columns gave excellent oligomeric resolution for the PS 580 sample.
GC Advantages 1. Very Large N (Very Long Columns) 2. No Packing Material (A=0) 3. Simple Mobile Phase (Compressed Gas) 4. Universal Detectors (FID) 5.
ProStar 210/218 Solvent Delivery Modules
Diagnostics – Quaternary Pump & Fraction Collector Analytical 920 LCSemi-Prep 940 LC.
ProStar 325 Detector Petro van Poppel – Field Support Specialist Friday, 9 October 2015.
Varian 920-LC Integrated Analytical HPLC
Using Linear Scale-up Principles and the Varian 940-LC with Scale-Up Module for the Isolation of 5-Hydroxytryptophan from Griffonia Simplicifolia Dennis.
History of Chromatography n Early LC carried out in glass columns n diameters: 1-5 cm n lengths: cm n Size of solid stationary phase n diameters:
900-LC P. van Poppel – Field Support Specialist October 2009.
Comparison of Competitors’ Evaporative Light Scattering Detectors
Varian 900-LC Series iHPLC
Gihan Gawish.Dr High Performance Liquid Chromatography.
VARIAN, INC. HPLC Products
1 Varian 940-LC Analytical to Prep HPLC. 2 Varian 940-LC Silver Bullets The 940-LC one instrument – many uses: –High performance automated Analytical.
Summary of Analytical protocols used for Dye and organic pigment analysis Maarten van Bommel.
BCWC Water-cooled water chillers with centrifugal compressor/s
The 900 series LC Analytical 920 LCSemi-Prep 940 LC.
SoSe 2006 Alexander Semmler: HPLC 1 Alexander Semmler HPLC High pressure liquid chromatography High performance -‘‘-
PL-ELS 2100 Ice. PL-ELS 2100 Ice Evaporation at Sub Ambient Temperatures The PL-ELS 2100 Ice comprises an Integrated Cooled Evaporator in combination.
HPLC Introduction & Safety P. van Poppel – Field Support SpecialistMarch 2010.
Varian Integrated HPLC Systems (iHPLC) Frankie Button HPLC Instrument Manager, Europe Region 1 November 2007.
HPLC detectors Adapted from: HPLC for Pharmaceutical Scientists
Diagnostics – Detectors Analytical 920 LCSemi-Prep 940 LC.
E q u i p m e n t and chemicals HPLC (High Pressure Liquid Chromatography): C18 column Settings: 280nm, 2.5mL/min (4000psi), isocratic conditions (10.
HPLC – High Performance Liquid Chromatography
SSI Binary Gradient Pump Modular Simplicity. Ideal Gradient Characteristics Modular design Small foot print Easy Maintenance Compatible with stand alone.
Introduction to training
212-LC Pump Technology Background August Dual Piston Pump Single piston pumps deliver then refill, forcing the use of a very large pulse damper.
ProStar 335 Detector Wednesday, 26 April 2017
Best Broken into four categories
Waters HPLC Competitive Review
Varian 920-LC Competitors. 2 Varian 920-LC Market Competitors Competitors Shimadzu Waters Agilent Dionex The 920-LC presents a significant step forward.
LC/MS Chromatography Systems 212-LC. 2 The Complete Solution Varian LC components, pumps, autosamplers and the New MS Workstation SW (V6.6) can be used.
Principles of HPLC Part 1: Overview Lab Methods Fall, 2013.
Multiple Module Vacuum Oven Productivity Enhancement System.
Comparison of the Varian 920-LC with Agilent 1200 Series HPLC.
Oil-free Vacuum Pump / Compressor Today’s Instruments Co., Ltd.
9100 HPLC Trouble shooting.
THE LASER QUALITY. ZAPHIRO, the new high range 2D laser machine by PRIMA INDUSTRIE, designed for very high productivity, quality, and flexibility. THE.
Digital Light Sources First introduced in 2001.
LIQUID CHROMATOGRAPHY
LIQUID CHROMATOGRAPHY
Micro Pump without use of check valves to achieve no pulsation flow
Micro Pump without use of check valves to achieve no pulsation flow
Varian 940-LC Analytical to Prep HPLC
FlexarTM: Advances in HPLC Sample Throughput
Plastic strapping machines
Agilent 1100 Series System Operating principles
Best Broken into four categories
HPLC detectors Pharmawiki 11/18/2018.
Diagnostics Analytical 920 LC Semi-Prep 940 LC
Gary Yanik (PDR-Separations) Leo Hsu, Xiqin Yang, Dave Thornton (GSK)
Total Solution for Flue Gas Analyzer Series
Presentation transcript:

Compact & Perfect for Your Satisfaction YL9300 HPLC System Compact & Perfect for Your Satisfaction

YL9300 HPLC Features Compact Design Perfect Performance Impact to competitors

YL9300 HPLC Features Compact Design Integrated LPG HPLC system : Vacuum Degasser + Quaternary Pump + UV Detector Easily upgraded parts : For wide wavelength range :190~900 nm (Standard:190~600 nm) : For wide flow rate rage : up to 10 ml/min (Standard: up to 5 ml/min ) Simple Maintenance : Pump & Vacuum Degasser modules in a sliding drawer

YL9300 HPLC Features Perfect Performance Increased mobile phase composition efficiency : Stable supply of mixed mobile phases through shock-resistant SUS tubing and low pump head volume : Pump on the bottom to strengthen suction force of pump Decreased solvent peak influence : New focus lens in a monochromator reducing mobile phase RI effect Narrow spectral bandwidth Greatly stabilized baseline with substantially minimized noise level

YL9300 HPLC Features Decreased solvent peak influence in comparison “A” HPLC Analysis Condition Mobile Phase : Water:MeOH=65:35 Wavelength : UV detector 550 nm Injection Volume : 100 ul Sample : Cyanocobalamin (Vitamin B12) Solvent Peak YL9300 HPLC

High speed data process by network (LAN) communication YL9300 HPLC Features Impact to competitors Competitive or even lower price than others High speed data process by network (LAN) communication Low maintenance cost : Integrated power board, SMPS & fan for 2 modules : Simplicated each part Modern injector bracket to install 2 manual injectors & 2 column switching valves

YL9300 HPLC Specification Vacuum Degasser Number of channel: 4 CHs Maximum flow rate: 10 ml/min per channel : 70% of Gas Removal in Methanol at > 0~2.0ml/min per channel Internal volume per channel: 925ul per channel Materials in contact with solvent: Teflon AF, PEEK and Glass-filled PTFE Safety & maintenance: Error detection

YL9300 HPLC Specification Quaternary Pump Compressibility compensation: Automatic Flow range: 0.001-5ml/min (Standard) 0.001-10ml/min (Option) Flow rate accuracy: ≤±1% at 1ml/min Flow rate precision: <0.1% RSD at 1ml/min Number of eluent lines: 4 Composition precision: <0.1% Composition accuracy : <0.5% Manual prime-purge(Standard) / Auto prime-purge(Option)

YL9300 HPLC Specification UV/VIS Detector Wavelength range: 190~600 nm (Standard) /190~900nm (Option) Data collection rate: up to 50Hz Light source: Deuterium arc lamp Tungsten lamp addible for visible range (Option) Bandwidth: 5 nm Wavelength accuracy: ±1 nm Wavelength precision: ±0.1nm Linearity: >99.5% at 2.5 AU (acetone, 254nm) Noise level: <±0.35 X 10-5 Abs/min, 254nm, dry cell Drift : <1 X 10-4 Abs/hour

YL9300 HPLC Specification System Information Communications: LAN Dimensions: 375 X 470 X 545mm (width X height X depth) Weight: 27 Kg Safety & maintenance: Leak detection, Diagnostics, Error detection Line Voltage: 100-240VAC, ±10% Line frequency: 50/60Hz, ±5% Power consumption : 150W